991 resultados para Medical protocols.
Resumo:
Data registration refers to a series of techniques for matching or bringing similar objects or datasets together into alignment. These techniques enjoy widespread use in a diverse variety of applications, such as video coding, tracking, object and face detection and recognition, surveillance and satellite imaging, medical image analysis and structure from motion. Registration methods are as numerous as their manifold uses, from pixel level and block or feature based methods to Fourier domain methods. This book is focused on providing algorithms and image and video techniques for registration and quality performance metrics. The authors provide various assessment metrics for measuring registration quality alongside analyses of registration techniques, introducing and explaining both familiar and state–of–the–art registration methodologies used in a variety of targeted applications.
Resumo:
Wireless Sensor Networks (WSNs) have been attracting increasing interests for developing a new generation of embedded systems with great potential for many applications such as surveillance, environment monitoring, emergency medical response and home automation. However, the communication paradigms in WSNs differ from the ones attributed to traditional wireless networks, triggering the need for new communication protocols. In this context, the recently standardised IEEE 802.15.4 protocol presents some potentially interesting features for deployment in wireless sensor network applications, such as power-efficiency, timeliness guarantees and scalability. Nevertheless, when addressing WSN applications with (soft/hard) timing requirements some inherent paradoxes emerge, such as power-efficiency versus timeliness, triggering the need of engineering solutions for an efficient deployment of IEEE 802.15.4 in WSNs. In this technical report, we will explore the most relevant characteristics of the IEEE 802.15.4 protocol for wireless sensor networks and present the most important challenges regarding time-sensitive WSN applications. We also provide some timing performance and analysis of the IEEE 802.15.4 that unveil some directions for resolving the previously mentioned paradoxes.
Resumo:
A metrologia na saúde tem um elevado grau de importância no quotidiano hospitalar dado que muitas decisões são tomadas com base em medições. Além disso, a constante evolução tecnológica na área da saúde e o número crescente de parâmetros fisiológicos dos equipamentos médicos exige a constante preocupação com o controlo metrológico. Assim, o funcionamento eficiente destes poderá contribuir para a segurança, uma melhor e mais rápida recuperação do doente e, consequentemente, um aumento do tempo de vida do equipamento, o que por sua vez se reflete numa maior economia de custos. A otimização de protocolos de metrologia em saúde, a elaboração de planos de controlo para validação de equipamentos médicos-hospitalares, a sensibilização de profissionais de saúde para o controlo metrológico, assim como o conhecimento das aplicações informáticas da organização são essenciais para uma eficaz gestão da manutenção hospitalar. O Serviço de Instalações e Equipamentos do Centro Hospitalar do Tâmega e Sousa, trabalha no sentido de assegurar uma resposta rápida, otimizada e eficiente para satisfazer as necessidades hospitalares através da aplicação de metodologias e ferramentas da qualidade destinadas à metrologia em saúde. Assim, o objetivo principal deste trabalho é apresentar metodologias e ferramentas aplicadas no controlo de parâmetros de equipamentos médico-hospitalares tais como, dispositivos de infusão, monitores de sinais vitais, eletrocardiógrafos, cardiotocógrafos, desfibrilhadores, incubadoras, aparelhos de fototerapia, bem como, o processo de gestão da manutenção aplicado pelo Serviço de Instalações e Equipamentos. Neste sentido foi possível demonstrar que o controlo metrológico é de extrema importância para uma instituição hospitalar.
Resumo:
IEEE International Conference on Communications (IEEE ICC 2015). 8 to 12, Jun, 2015, IEEE ICC 2015 - Communications QoS, Reliability and Modeling, London, United Kingdom.
Resumo:
Soft-tissue and bone necrosis, although rare in childhood, occasionally occur in the course of infectious diseases, either viral or bacterial, and seem to be the result of hypoperfusion on a background of disseminated intravascular coagulation. Treatment consists in correction of septic shock and control of necrosis. Necrosis, once started, shows extraordinarily rapid evolution, leading to soft-tissue and bone destruction and resulting in anatomic, functional, psychological, and social handicaps. Ten mutilated children were treated from January 1986 to January 1999 in Hospital de Dona Estefaˆ nia, Lisbon, Portugal. One was recovering from hemolytic-uremic syndrome with a severe combined immunodeficiency, another malnourished, anemic child had malaria, and three had chicken pox (in one case complicated by meningococcal septicemia). There were three cases of meningococcal and two of pyocyanic septicemia (one in a burned child and one in a patient with infectious mononucleosis). The lower limbs (knee,leg, foot) were involved in five cases, the face (ear, nose, lip) in four, the perineum in three, the pelvis (inguinal region, iliac crest) in two, the axilla in one, and the upper limb (radius, hand) in two. Primary prevention is based on early recognition of risk factors and timely correction. Secondary prevention consists of immediate etiologic and thrombolytic treatment to restrict the area of necrosis. Tertiary prevention relies on adequate rehabilitation with physiotherapy and secondary operations to obtain the best possible functional and esthetic result.
Resumo:
Wireless body area networks (WBANs) are expected to play a significant role in smart healthcare systems. One of the most important attributes of WBANs is to increase network lifetime by introducing novel and low-power techniques on the energy-constrained sensor nodes. Medium access control (MAC) protocols play a significant role in determining the energy consumption in WBANs. Existing MAC protocols are unable to accommodate communication requirements in WBANs. There is a need to develop novel, scalable and reliable MAC protocols that must be able to address all these requirements in a reliable manner. In this special issue, we attracted high quality research and review papers on the recent advances in MAC protocols for WBANs.
Resumo:
A Masters Thesis, presented as part of the requirements for the award of a Research Masters Degree in Economics from NOVA – School of Business and Economics
Resumo:
The work presented in this thesis was developed in collaboration with a Portuguese company, BeyonDevices, devoted to pharmaceutical packaging, medical technology and device industry. Specifically, the composition impact and surface modification of two polymeric medical devices from the company were studied: inhalers and vaginal applicators. The polyethylene-based vaginal applicator was modified using supercritical fluid technology to acquire self-cleaning properties and prevent the transport of bacteria and yeasts to vaginal flora. For that, in-situ polymerization of 2-substituted oxazolines was performed within the polyethylene matrix using supercritical carbon dioxide. The cationic ring-opening polymerization process was followed by end-capping with N,N-dimethyldodecylamine. Furthermore, for the same propose, the polyethylene matrix was impregnated with lavender oil in supercritical medium. The obtained materials were characterized physical and morphologically and the antimicrobial activity against bacteria and yeasts was accessed. Materials modified using 2-substituted oxazolines showed an effective killing ability for all the tested microorganisms, while the materials modified with lavender oil did not show antimicrobial activity. Only materials modified with oligo(2-ethyl-2-oxazoline) maintain the activity during the long term stability. Furthermore, the cytotoxicity of the materials was tested, confirming their biocompatibilty. Regarding the inhaler, its surface was modified in order to improve powder flowability and consequently, to reduce powder retention in the inhaler´s nozzle. New dry powder inhalers (DPIs), with different needle’s diameters, were evaluated in terms of internal resistance and uniformity of the emitted dose. It was observed that they present a mean resistance of 0.06 cmH2O0.5/(L/min) and the maximum emitted dose obtained was 68.9% for the inhaler with higher needle´s diameter (2 mm). Thus, this inhaler was used as a test and modified by the coating with a commonly-used force control agent, magnesium stearate, dried with supercritical carbon dioxide (scCO2) and the uniformity of delivered dose tests were repeated. The modified inhaler showed an increase in emitted dose from 68.9% to 71.3% for lactose and from 30.0% to 33.7% for Foradil.
Resumo:
The purpose of this work project is to evaluate Cascais’ potential of becoming a reference in Health Care and Medical Tourism in the near future. It is done a careful research about the industry, followed by a thorough analysis of the region. It is concluded that it holds many key characteristics and conditions for the development of this kind of clusters, even though it lacks consumers’ perception regarding this product. Some guidelines are suggested in order to position Cascais as a competitive player in this field.
Resumo:
ABSTRACT - Objectives: We attempted to show how the implementation of the key elements of the World Health Organization Patient Safety Curriculum Guide Multi-professional Edition in an undergraduate curriculum affected the knowledge, skills, and attitudes towards patient safety in a graduate entry Portuguese Medical School. Methods: After receiving formal recognition by the WHO as a Complementary Test Site and approval of the organizational ethics committee , the validated pre-course questionnaires measuring the knowledge, skills, and attitudes to patient safety were administered to the 2nd and3rd year students pursuing a four-year course (N = 46). The key modules of the curriculum were implemented over the academic year by employing a variety of learning strategies including expert lecturers, small group problem-based teaching sessions, and Simulation Laboratory sessions. The identical questionnaires were then administered and the impact was measured. The Curriculum Guide was evaluated as a health education tool in this context. Results: A significant number of the respondents, 47 % (n = 22), reported having received some form of prior patient safety training. The effect on Patient Safety Knowledge was assessed by using the percentage of correct pre- and post-course answers to construct 2 × 2 contingency tables and by applying Fishers’ test (two-tailed). No significant differences were detected (p < 0.05). To assess the effect of the intervention on Patient Safety skills and attitudes, the mean and standard deviation were calculated for the pre and post-course responses, and independent samples were subjected to Mann-Whitney’s test. The attitudinal survey indicated a very high baseline incidence of desirable attitudes and skills toward patient safety. Significant changes were detected (p < 0.05) regarding what should happen if an error is made (p = 0.016), the role of healthcare organizations in error reporting (p = 0.006), and the extent of medical error (p = 0.005). Conclusions: The implementation of selected modules of the WHO Patient Safety Curriculum was associated with a number of positive changes regarding patient safety skills and attitudes, with a baseline incidence of highly desirable patient safety attitudes, but no measureable change on the patient safety knowledge, at the University of Algarve Medical School. The significance of these results is discussed along with implications and suggestions for future research.
Resumo:
Equity research report