946 resultados para Mean square analysis
Resumo:
Molecular dynamics simulations of the oligonucleotide duplex d(CGCGCG)2 in aqueous solution are used to investigate the glass transition phenomenon. The simulations were performed at temperatures in the 20 K to 340 K range. The mean square atomic fluctuations showed that the behavior of the oligonucleotide duplex was harmonic at low temperatures. A glass transition temperature at 223 K to 234 K was inferred for the oligonucleotide duplex, which is in agreement with experimental observations. The largest number of hydrogen bounds between the polar atoms of the oligonucleotide duplex and the water molecules was obtained at the glass transition temperature. With increasing temperature we observed a decrease in the average lifetime of the hydrogen bonds to water molecules.
Resumo:
To characterize the functionally important anharmonic motions of proteins, simulations of carboxymyoglobin (MbCO) dynamics have been performed during which dihedral transitions were prohibited. Comparison of torsionally restrained and unrestrained protein dynamics simulated at three levels of hydration and at temperatures ranging from 100 to 400 K suggests that hydration "catalyzes" protein mobility by facilitating collective anharmonic motions that do not require dihedral transitions. When dihedral transitions were prohibited, dehydrated MbCO, to a good approximation, exhibited only harmonic fluctuations, whereas hydrated MbCO exhibited both harmonic and anharmonic motions. The fluctuation of helix centers of mass also remained highly anharmonic in the torsionally restrained hydrated system. Atomic mean-square fluctuation at 300 K was reduced upon prohibition of dihedral transitions by only 28% and 10% for MbCO hydrated by 350 and 3830 water molecules, respectively.
Resumo:
Progress in homology modeling and protein design has generated considerable interest in methods for predicting side-chain packing in the hydrophobic cores of proteins. Present techniques are not practically useful, however, because they are unable to model protein main-chain flexibility. Parameterization of backbone motions may represent a general and efficient method to incorporate backbone relaxation into such fixed main-chain models. To test this notion, we introduce a method for treating explicitly the backbone motions of alpha-helical bundles based on an algebraic parameterization proposed by Francis Crick in 1953 [Crick, F. H. C. (1953) Acta Crystallogr. 6, 685-689]. Given only the core amino acid sequence, a simple calculation can rapidly reproduce the crystallographic main-chain and core side-chain structures of three coiled coils (one dimer, one trimer, and one tetramer) to within 0.6-A root-mean-square deviations. The speed of the predictive method [approximately 3 min per rotamer choice on a Silicon Graphics (Mountain View, CA) 4D/35 computer] permits it to be used as a design tool.
Resumo:
Current research on the collaborative behaviors of conventional and alternative health care providers for the treatment of anxiety is lacking. While there are multiple studies looking at alternative health care integration into primary care, none of them look at anxiety specifically. The purpose of this paper is to provide a preliminary exploration of possible barriers to collaboration between conventional and alternative health care providers for the treatment of anxiety. Quantitative data on collaboration behavior patterns were obtained with an anonymous survey. Data from the surveys were analyzed using a chi-square analysis. Along with these numerical data narrative data from the survey and interviews were collected in order to assess beliefs about the barriers to collaboration from different health care providers. The results indicate that conventional providers collaborate the least with alternative providers and alternative providers collaborate the least with conventional providers. The descriptive results regarding the barriers to collaboration from the study illustrated a common theme, specifically, the lack of education of conventional providers on alternative health care practices on anxiety. This is an exploratory study: therefore it would be beneficial for future researchers to look deeper into the beliefs of health care providers on the barriers to collaboration, possibly identifying the specific barriers to collaboration for each type of healthcare provider.
Resumo:
La temperatura superficial del mar (SST) estimada a partir de los productos 11 μm diurnos y nocturnos y 4 μm nocturnos del sensor MODIS (Moderate Resolution Imaging Spectroradiometer) a bordo de la plataforma Aqua, han sido comparados con datos medidos in situ a tres profundidades diferentes (15, 50 y 100 cm) en una zona costera del Mediterráneo Occidental. Esta comparación ha permitido analizar la incertidumbre que existe en la estimación de este parámetro en aguas someras y próximas a la costa mediante imágenes de satélite de baja resolución espacial. Los resultados obtenidos demuestran que el producto diurno SST_11 μm, obtiene los estadísticos RMSE (error cuadrático medio) y r2 (coeficiente de correlación de Pearson) más ajustados con valores de 1°C y 0,96, respectivamente, para la profundidad 50 cm.
Resumo:
Purpose To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. Methods Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. Results Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = −0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = −0.551, p = 0.04), but not with higher order RMS (r = −0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. Conclusions Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.
Reverse Geometry Hybrid Contact Lens Fitting in a Case of Donor-Host Misalignment after Keratoplasty
Resumo:
Purpose: To report the successful outcome obtained after fitting a new hybrid contact lens in a cornea with an area of donor-host misalignment and significant levels of irregular astigmatism after penetrating keratoplasty (PKP). Materials and methods: A 41-year-old female with bilateral asymmetric keratoconus underwent PKP in her left eye due to the advanced status of the disease. One year after surgery, the patient referred a poor visual acuity and quality in this eye. The fitting of different types of rigid gas permeable contact lenses was performed, but with an unsuccessful outcome due to contact lens stability problems and uncomfortable wear. Scheimpflug imaging evaluation revealed that a donor-host misalignment was present at the nasal area. Contact lens fitting with a reverse geometry hybrid contact lens (Clearkone, SynergEyes Carlsbad) was then fitted. Visual, refractive, and ocular aberrometric outcomes were evaluated during a 1-year period after the fitting. Results: Uncorrected distance visual acuity improved from a prefitting value of 20/200 to a best corrected postfitting value of 20/20. Prefitting manifest refraction was +5.00 sphere and -5.50 cylinder at 75°, with a corrected distance visual acuity of 20/30. Higher order root mean square (RMS) for a 5 mm pupil changed from a prefitting value of 6.83 µm to a postfitting value of 1.57 µm (5 mm pupil). The contact lens wearing was referred as comfortable, with no anterior segment alterations. Conclusion: The SynergEyes Clearkone contact lens seems to be another potentially useful option for the visual rehabilitation after PKP, especially in cases of donor-host misalignment.
Resumo:
Purpose: To report a very successful outcome obtained with the fitting of a new-generation hybrid contact lens of reverse geometry in a thin cornea with extreme irregularity due to the presence of a central island after unsuccessful myopic excimer laser refractive surgery. Methods: A 32-year-old man attended to our clinic complaining of very poor vision in his right eye after bilateral laser in situ keratomileusis (treatment or surgery) for myopia correction and some additional retreatments afterward. After a comprehensive ocular evaluation, contact lens fitting with a reverse geometry hybrid contact lens (SynergEyes PS, SynergEyes, Carlsbad, CA) was proposed as a solution for this case. Visual, refractive, and ocular aberrometric outcomes with the contact lens were evaluated. Results: Distance visual acuity improved from a prefitting uncorrected value of 20/200 to a postfitting corrected value of 20/16. Prefitting manifest refraction was +6.00 sphere and −3.00 cylinder at 70°, with a corrected distance visual acuity of 20/40. Higher order root mean square for a 5-mm pupil changed from a prefitting value of 1.45 to 0.34 µm with the contact lens. The contact lens wearing was reported as comfortable, and the patient was very satisfied with this solution. Conclusions: The SynergEyes PS contact lens seems to be an excellent option for the visual rehabilitation of corneas with extreme irregularity after myopic excimer laser surgery, minimizing the level of higher order aberrations and providing an excellent visual outcome.
Resumo:
This paper deals with the estimation of a time-invariant channel spectrum from its own nonuniform samples, assuming there is a bound on the channel’s delay spread. Except for this last assumption, this is the basic estimation problem in systems providing channel spectral samples. However, as shown in the paper, the delay spread bound leads us to view the spectrum as a band-limited signal, rather than the Fourier transform of a tapped delay line (TDL). Using this alternative model, a linear estimator is presented that approximately minimizes the expected root-mean-square (RMS) error for a deterministic channel. Its main advantage over the TDL is that it takes into account the spectrum’s smoothness (time width), thus providing a performance improvement. The proposed estimator is compared numerically with the maximum likelihood (ML) estimator based on a TDL model in pilot-assisted channel estimation (PACE) for OFDM.
Resumo:
LIDAR (LIght Detection And Ranging) first return elevation data of the Boston, Massachusetts region from MassGIS at 1-meter resolution. This LIDAR data was captured in Spring 2002. LIDAR first return data (which shows the highest ground features, e.g. tree canopy, buildings etc.) can be used to produce a digital terrain model of the Earth's surface. This dataset consists of 74 First Return DEM tiles. The tiles are 4km by 4km areas corresponding with the MassGIS orthoimage index. This data set was collected using 3Di's Digital Airborne Topographic Imaging System II (DATIS II). The area of coverage corresponds to the following MassGIS orthophoto quads covering the Boston region (MassGIS orthophoto quad ID: 229890, 229894, 229898, 229902, 233886, 233890, 233894, 233898, 233902, 233906, 233910, 237890, 237894, 237898, 237902, 237906, 237910, 241890, 241894, 241898, 241902, 245898, 245902). The geographic extent of this dataset is the same as that of the MassGIS dataset: Boston, Massachusetts Region 1:5,000 Color Ortho Imagery (1/2-meter Resolution), 2001 and was used to produce the MassGIS dataset: Boston, Massachusetts, 2-Dimensional Building Footprints with Roof Height Data (from LIDAR data), 2002 [see cross references].
Resumo:
This dataset consists of 2D footprints of the buildings in the metropolitan Boston area, based on tiles in the orthoimage index (orthophoto quad ID: 229890, 229894, 229898, 229902, 233886, 233890, 233894, 233898, 233902, 237890, 237894, 237898, 237902, 241890, 241894, 241898, 241902, 245898, 245902). This data set was collected using 3Di's Digital Airborne Topographic Imaging System II (DATIS II). Roof height and footprint elevation attributes (derived from 1-meter resolution LIDAR (LIght Detection And Ranging) data) are included as part of each building feature. This data can be combined with other datasets to create 3D representations of buildings and the surrounding environment.
Resumo:
Le traumatisme craniocérébral léger (TCCL) a des effets complexes sur plusieurs fonctions cérébrales, dont l’évaluation et le suivi peuvent être difficiles. Les problèmes visuels et les troubles de l’équilibre font partie des plaintes fréquemment rencontrées après un TCCL. En outre, ces problèmes peuvent continuer à affecter les personnes ayant eu un TCCL longtemps après la phase aiguë du traumatisme. Cependant, les évaluations cliniques conventionnelles de la vision et de l’équilibre ne permettent pas, la plupart du temps, d’objectiver ces symptômes, surtout lorsqu’ils s’installent durablement. De plus, il n’existe pas, à notre connaissance, d’étude longitudinale ayant étudié les déficits visuels perceptifs, en tant que tels, ni les troubles de l’équilibre secondaires à un TCCL, chez l’adulte. L’objectif de ce projet était donc de déterminer la nature et la durée des effets d’un tel traumatisme sur la perception visuelle et sur la stabilité posturale, en évaluant des adultes TCCL et contrôles sur une période d’un an. Les mêmes sujets, exactement, ont participé aux deux expériences, qui ont été menées les mêmes jours pour chacun des sujets. L’impact du TCCL sur la perception visuelle de réseaux sinusoïdaux définis par des attributs de premier et de second ordre a d’abord été étudié. Quinze adultes diagnostiqués TCCL ont été évalués 15 jours, 3 mois et 12 mois après leur traumatisme. Quinze adultes contrôles appariés ont été évalués à des périodes identiques. Des temps de réaction (TR) de détection de clignotement et de discrimination de direction de mouvement ont été mesurés. Les niveaux de contraste des stimuli de premier et de second ordre ont été ajustés pour qu’ils aient une visibilité comparable, et les moyennes, médianes, écarts-types (ET) et écarts interquartiles (EIQ) des TR correspondant aux bonnes réponses ont été calculés. Le niveau de symptômes a également été évalué pour le comparer aux données de TR. De façon générale, les TR des TCCL étaient plus longs et plus variables (plus grands ET et EIQ) que ceux des contrôles. De plus, les TR des TCCL étaient plus courts pour les stimuli de premier ordre que pour ceux de second ordre, et plus variables pour les stimuli de premier ordre que pour ceux de second ordre, dans la condition de discrimination de mouvement. Ces observations se sont répétées au cours des trois sessions. Le niveau de symptômes des TCCL était supérieur à celui des participants contrôles, et malgré une amélioration, cet écart est resté significatif sur la période d’un an qui a suivi le traumatisme. La seconde expérience, elle, était destinée à évaluer l’impact du TCCL sur le contrôle postural. Pour cela, nous avons mesuré l’amplitude d’oscillation posturale dans l’axe antéropostérieur et l’instabilité posturale (au moyen de la vitesse quadratique moyenne (VQM) des oscillations posturales) en position debout, les pieds joints, sur une surface ferme, dans cinq conditions différentes : les yeux fermés, et dans un tunnel virtuel tridimensionnel soit statique, soit oscillant de façon sinusoïdale dans la direction antéropostérieure à trois vitesses différentes. Des mesures d’équilibre dérivées de tests cliniques, le Bruininks-Oseretsky Test of Motor Proficiency 2nd edition (BOT-2) et le Balance Error Scoring System (BESS) ont également été utilisées. Les participants diagnostiqués TCCL présentaient une plus grande instabilité posturale (une plus grande VQM des oscillations posturales) que les participants contrôles 2 semaines et 3 mois après le traumatisme, toutes conditions confondues. Ces troubles de l’équilibre secondaires au TCCL n’étaient plus présents un an après le traumatisme. Ces résultats suggèrent également que les déficits affectant les processus d’intégration visuelle mis en évidence dans la première expérience ont pu contribuer aux troubles de l’équilibre secondaires au TCCL. L’amplitude d’oscillation posturale dans l’axe antéropostérieur de même que les mesures dérivées des tests cliniques d’évaluation de l’équilibre (BOT-2 et BESS) ne se sont pas révélées être des mesures sensibles pour quantifier le déficit postural chez les sujets TCCL. L’association des mesures de TR à la perception des propriétés spécifiques des stimuli s’est révélée être à la fois une méthode de mesure particulièrement sensible aux anomalies visuomotrices secondaires à un TCCL, et un outil précis d’investigation des mécanismes sous-jacents à ces anomalies qui surviennent lorsque le cerveau est exposé à un traumatisme léger. De la même façon, les mesures d’instabilité posturale se sont révélées suffisamment sensibles pour permettre de mesurer les troubles de l’équilibre secondaires à un TCCL. Ainsi, le développement de tests de dépistage basés sur ces résultats et destinés à l’évaluation du TCCL dès ses premières étapes apparaît particulièrement intéressant. Il semble également primordial d’examiner les relations entre de tels déficits et la réalisation d’activités de la vie quotidienne, telles que les activités scolaires, professionnelles ou sportives, pour déterminer les impacts fonctionnels que peuvent avoir ces troubles des fonctions visuomotrice et du contrôle de l’équilibre.
Resumo:
Marine organic matter (OM) sinks from surface waters to the seafloor via the biological pump. Benthic communities, which use this sedimented OM as energy and carbon source, produce dissolved organic matter (DOM) in the process of remineralization, enriching the sediment porewater with fresh DOM compounds. We hypothesized that in the oligotrophic deep Arctic basin the molecular signal of freshly deposited primary produced OM is restricted to the surface sediment pore waters which should differ from bottom water and deeper sediment pore water in DOM composition. This study focused on: 1) the molecular composition of the DOM in sediment pore waters of the deep Eurasian Arctic basins, 2) whether the signal of marine vs. terrigenous DOM is represented by different compounds preserved in the sediment pore waters and 3) whether there is any relation between Arctic Ocean ice cover and DOM composition. Molecular data, obtained via 15 Tesla Fourier transform ion cyclotron resonance mass spectrometer, were correlated with environmental parameters by partial least square analysis. The fresher marine detrital OM signal from surface waters was limited to pore waters from < 5 cm sediment depth. The productive ice margin stations showed higher abundances of peptides, unsaturated aliphatics and saturated fatty acids formulae, indicative of fresh OM/pigments deposition, compared to northernmost stations which had stronger aromatic signals. This study contributes to the understanding of the coupling between the Arctic Ocean productivity and its depositional regime, and how it will be altered in response to sea ice retreat and increasing river runoff.
Resumo:
During Leg 138, we measured reflectance spectra in the visible and near-infrared bands (455-945 nm) every few centimeters on split core surfaces from eastern tropical Pacific Ocean sediments. Here, we evaluate predictions of the content of biogenic calcite, biogenic opal, and nonbiogenic sediments from the reflectance spectra. For Sites 844 through 847, which contain a significant nonbiogenic component, reflectance spectra yielded a useful proxy for the percentages of CaCO3 over a wide range of values from nearly 0% to 100%, with root-mean-square (RMS) errors of about 9%. Direct estimates of "nonbiogenic" sediment percentages, approximated by 100 - (CaCO3 + opal), were reasonably successful (RMS error of 10%), however, were incorrect in some intervals. This suggests that mineralogy of the nonbiogenic material changes through time and that further subdivision of this component will be needed for useful estimation from reflectance. For percentages of biogenic opal, calibration equations appear to work well (RMS error of 6%) at concentrations of less than 30%, but for higher opal concentrations, reflectance equations often underestimate the true contents of opal. Improvements in multiparameter lithologic estimates from reflectance spectra may come from (1) expanding the wavelengths measured to better capture unique mineral reflectance bands, and (2) adding the ability to measure diffuse, rather than directional, reflectance to minimize the effects of surface roughness.
Resumo:
Structure from Motion (SfM) is a new form of photogrammetry that automates the rendering of georeferenced 3D models of objects using digital photographs and independently surveyed Ground Control Points (GCPs). This project seeks to quantify the error found in Digital Elevation Models (DEMs) produced using SfM. I modeled a rockslide found at the Cadman Quarry (Monroe, Washington) because the surface is vegetation-free, which is ideal for SfM and Terrestrial LiDAR Scanner (TLS) surveys. By using SfM, TLS, and GPS positioning at the same time, I attempted to find the deviation in the SfM model from the TLS model and GPS points. Using the deviation, I found the Root-Mean-Square Error (RMSE) between the SfM DEM and GPS positions. The RMSE of the SfM model when compared to surveyed GPS points is 17cm. I propagated the uncertainty of the GPS points with the RMSE of the SfM model to find the uncertainty of the SfM model compared to the NAD 1984 datum. The uncertainty of the SfM model compared to the NAD 1984 is 27cm. This study did not produce a model from the TLS that had sufficient resolution on horizontal surfaces to compare to surveyed GPS points.