955 resultados para Maxillary sinus lifting


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and objective: Stress during pregnancy may alter offspring susceptibility to diseases during adulthood. In the present study, female Lewis rats were subjected to chronic stress during the gestational period, and the effect of this stress was evaluated histometrically on the progression of ligature-induced bone loss in their adult offspring.Material and methods: After confirming pregnancy, half of the pregnant rats were randomly designated as control animals (no stress regimen was imposed), and the other half was submitted to a chronic stress model (immobilization at cold temperature) between the 7th and the 18th gestational day. After birth, 12 male rats delivered by stressed mothers - Group 1 (G1) - and 12 male rats delivered by non-stressed mothers - Group 2 (G2) - were selected. When birthed rats reached 250 g of body weight, a silk ligature was placed around their maxillary right second molar in order to induce bone loss. The non-ligated left side served as a control. Sixty days later, these animals were sacrificed by anaesthetic overdose. After routine laboratorial processing, images of the histological sections were digitized and submitted for histometric measurement using two parameters: histological attachment loss and bone loss.Results: on the ligated side, G1 presented with greater histological attachment and bone loss than G2 (p < 0.05). on the non-ligated control side, neither of the groups presented with alterations in these parameters (p > 0.05).Conclusion: The chronic stress regimen imposed on pregnant rats produced a greater progression of ligature-induced bone loss in their adult offspring. (C) 0 2011 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to present the clinical features and treatment of a case of maxillary ameloblastic carcinoma. A meloblastic carcinoma is a rare malignant odontogenic carcinoma that has metastatic potential. Due to its rare incidence, there are few studies focusing on its radiological characteristics. When ameloblastic carcinoma demonstrates an aggressive appearance, it may be diagnosed as a malignant tumor; however, in cases showing a non-aggressive appearance, it is difficult to distinguish ameloblastic carcinoma from ameloblastoma. We report a case of ameloblastic carcinoma of the maxilla in a 59-year-old male patient, including the clinical signs, radiological images and pathological features. A partial area was surgically excised under local anesthesia and the material was sent to the Laboratory of Oral Pathology. The histological sections revealed a fragmented odontogenic tumor of epithelial origin, consisting of solid parenchyma and also revealed basal cells resembling ameloblasts, occasionally arranged in palisades. Certain parts of the architecture resembled that of an ameloblastoma; however, the cytology of other areas confirmed the diagnosis of ameloblastic carcinoma of the maxilla. The patient was scheduled for definitive surgery, including a right maxillectomy and radiotherapy. The patient was followed up every 3 months. After 2 years follow-up, there were no clinical or radiological signs of recurrence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of unilateral angular misfit of 100 Km on stress distribution of implant-supported single crowns with ceramic veneering and gold framework by three-dimensional finite element analysis. Two three-dimensional models representing a maxillary section of premolar region were constructed: group 1 (control)-crown completely adapted to the implant and group 2-crown with unilateral angular misfit of 100 Km. A vertical force of 100 N was applied on 2 centric points of the crown. The von Mises stress was used as an analysis criterion. The stress values and distribution in the main maps (204.4 MPa for group 1 and 205.0 MPa for group 2) and in the other structures (aesthetic veneering, framework, retention screw, implant, and bone tissue) were similar for both groups. The highest stress values were observed between the first and second threads of the retention screw. Considering the bone tissue, the highest stress values were exhibited in the peri-implant cortical bone. The unilateral angular misfit of 100 Km did not influence the stress distribution on the implant-supported prosthesis under static loading.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Obturators and facial prostheses are important not only in rehabilitation and aesthetics, but also in patient re-socialisation. The level of reintegration is directly related to the degree of satisfaction with rehabilitation. So, the maxillofacial prosthetics must provide patient satisfaction during treatment. This study aimed to search information in database and conduct a literature review on patient satisfaction with maxillofacial prosthesis. The problems experienced by these patients may decrease when specialists keep the patient on regular inspection. Rehabilitation through alloplasty or prosthetic restoration provides satisfactory conditions in aesthetics and well-being and reinstates individuals in familial and social environment. (C) 2008 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective:This study investigated the efficacy of different techniques for the union of fragments of a denture before repair and on the accuracy of the reposition.Materials and methods:For this study, 20 maxillary dentures made with Lucitone 550 heat-cured resin were used. Points were determined with a scanner on the cusp of the teeth, as a measurement of the segments. After digitisation, each model was exported to the AUTOCAD R 14 program and two-dimensional measurements of the distances between the marked points were made. After the initial analysis, the dentures were fractured into two segments using an impact test machine. For the repair, maxillary dentures were divided into two groups; in the first, the repair was carried out using Kerr's sticky wax and in the second group, Super Bonder was used to join the fragments, with subsequent inclusion of DENTSPLY((R)) Repair Material resin. After the repair, the points of the maxillary dentures were measured again. The numerical values obtained were tabulated to compare the measurements before fracture and after the repair. For statistical analysis, analysis of variance was employed, using a single factor and double factor, followed by the Tukey test with a reliability of 95%.Results:The results demonstrated a statistically significant difference between the materials used to join the dentures for repair, where the dentures were joined with sticky wax presented a larger variation in the distances between the points.Conclusion:The variation in distances between the points is influenced by the agent of repair.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Considering that an increasing number of patients are victims of mutilator surgical resections, these studies are important for treatment success of rehabilitation of patients presenting oronasal communication.Purpose: The aim of this study was to assess the stress distribution through photoelasticity in palatal obturator prostheses with different attachment systems for implants.Methods: Two photoelastic models were obtained from an experimental maxillary model presenting an oronasal communication. One model was fabricated without implant, and the other with 2 implants 10 mm in length inserted in the left crest. Four colorless palatal obturator prostheses were fabricated. One prosthesis presented no attachment system, whereas the remaining prostheses were adapted to 3 attachment systems. The assembly was positioned in a circular polariscope for application of axial load.Results: The results were based on photographic records of stress in the photoelastic model submitted to loading. The records revealed higher stress concentration on the bar-clip system followed by the O'ring/bar-clip and O'ring systems, respectively. A homogeneous stress distribution was observed on the photoelastic model with the mucous-supported prosthesis.Conclusions: The attachment systems generated different characteristics of stress distribution that was concentrated surrounding the implants. The bar-clip system exhibited the highest stress concentration on the alveolar crest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the frequency of removable partial dentures (RPD) at the Aracatuba Dental School.Methods: The study was conducted by analysing 412 clinical history of patients attended at the RPD clinics in the period from 2000 to 2007.Results: 412 charts were analysed: 148 (35.9%) men and 264 (64.1%) women. The mean age was 53.8 years (men) and 52.4 years (women). A total of 556 dentures were made; of these, 233 (41.90%) were maxillary and 323 (58.09%) were mandibular dentures. The most frequent Kennedy classification found was Class III (maxilla) and Class I (mandible). In the maxilla, 55% (126) of the major connectors were of the anterior-posterior palatal bar, while in the mandible, 64% (202) were the lingual bar. As regards the claps, 401 were circumferential and 318 were bar claps.Conclusion: The mean age of the patients was 52.9 years with higher prevalence of female patients; the most frequent Kennedy's classification was Class I in mandible and Class III in maxilla; the most common major connector was anterior-posterior palatal bar for maxilla and lingual bar for mandible; the circumferential clasps were the most common retainer used in both jaws.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The extent of separation between the maxillary and mandibular teeth in the fabrication of interocclusal splints designed to achieve efficiency and muscle relaxation is controversial and undefined in the literature. Based on this premise, the aim of this study was to evaluate the effect of interocclusal splint thicknesses of 3 and 6 millimeters on the electrical activity of the anterior temporal and masseter muscles during rest and dental clenching. Twenty asymptomatic individuals (10 males and 10 females) were selected using the Research Diagnostic Criteria (RDC). Electromyography (EMG) was performed both with and without the 3- and 6-mm splints using the Bio EMG software package, which recorded values given in microvolts (mu V). The results, which were assessed using analysis of variance (ANOVA) to a 5% significance level (p < 0.05), showed increased electrical activity of the masticatory muscles during dental clenching compared with at rest, with greater activity in the masseter muscle. The electrical activity did not differ according to the thickness of the splints or between males and females. We can conclude that both splint thicknesses are effective in treating muscle hyperactivity given their similar clinical behavior for asymptomatic individuals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although tumors of minor salivary glands are rare, the pleomorphic adenoma is the most common pathology among the benign neoplasm and can be found with high prevalence in the junction between hard palate and soft palate. The treatment of choice for most of maxillary tumors is surgical through either a total or partial maxillectomy. However, surgical defects caused by such type of treatment lead to both clinical and psychologic disorders for the patient. The immediate oral rehabilitation using interim palate obturator after maxillectomy provides optimization on the healing process, recovers the stomatognathic functions after surgery, and avoids psychosocial sequelae for the patients. This clinical report aimed to present the rehabilitation with immediate palate obturator of a patient who underwent a partial maxillectomy due to a hard palate pleomorphic adenoma of minor salivary glands. We report the clinical importance of the prosthetic rehabilitation and the improvements on both quality of life and stomatognathic functions of this patient. It can be concluded that the immediate rehabilitation of the patient after partial maxillectomy by using an interim palate obturator was a great option and provided clinical benefits in the immediate postoperative period, improving the patient's quality of life, allowing the patient's reinsertion into society, and reducing the surgical treatment sequelae.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to compare the artificial tooth positional changes following the flasking and polymerization of complete dentures by a combination of two flasking methods and two polymerization techniques using computer graphic measurements.Materials and Methods: Four groups of waxed complete dentures (n = 10) were invested and polymerized using the following techniques: (1) adding a second investment layer of gypsum and conventional water bath polymerization (Control), (2) adding a second investment layer of gypsum and polymerization with microwave energy (Gyp-micro), (3) adding a second investment layer of silicone (Zetalabor) and conventional polymerization (Silwater), and (4) adding a second investment layer of silicone and polymerization with microwave energy (Silmicro). For each specimen, six segments of interdental distances (A to F) were measured to determine the artificial tooth positions in the waxed and polymerized stages using software program AutoCad R14. The mean values of the changes were statistically compared by univariate ANOVA with Tukey post-hoc test at 5% significance.Results: There were no significant differences among the four groups, except for segment D of the Silmicro group (-0.004 +/- 0.032 cm) in relation to the Gypwater group (0.044 +/- 0.031 cm) (p < 0.05), which presented, repectively, expansion and shrinkage after polymerization.Conclusions: Within the limitations of this study, it was concluded that although the differences were not statistically significant, the use of a silicone investment layer when flasking complete dentures resulted in the least positional changes of the artificial teeth regardless of the polymerization technique.