917 resultados para Mass spectrometry imaging


Relevância:

90.00% 90.00%

Publicador:

Resumo:

A pilot experiment of mass measurement was performed at CSRe with the method of isochronous mass spectrometry. The secondary fragments produced via RIBLL2 with the primary beam of 400 MeV/u, Ar-36 delivered by CSRm were injected into CSRe. The revolution periods of the stored ions, which depend on the mass-to-charge ratios of the stored ions, were measured with a time-of-flight detector system. The results show that the mass resolution around 8 x 10(-6) for Delta m/m is achieved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Mass measurements of exotic nuclei is a fast, developing field which is essential for basic nuclear physics and a wide range of applications. The method of storage ring mass spectrometry has many advantages: (1) a large amount of nuclides can be simultaneously measured; (2) very short-lived (T-1/2 greater than or similar to 50 mu s) and very rare species (yields down to single ions) can be accessed; (3) nuclides in several atomic charge states can be investigated, (4) half-life measurements can be performed with time-resolved mass spectrometry. In this contribution we concentrate on some recent achievements and future perspectives of the storage ring mass spectrometry.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A high performance Time-of-Flight detector has been designed and constructed for isochronous mass spectrometry at the experimental Cooler Storage Ring (CSRe) The detector has been successfully used in an experiment to measure the masses of the N approximate to Z approximate to 33 nuclides near the proton drip-line Of particular interest is the mass of As-65 A maximum detection efficiency of 70% and a time resolution of 118 +/- 8 Ps (FWHM) have been achieved in the experiment The dependence of detection efficiency and signal average pulse height (APH) on atomic number Z has been studied The potential of APH for Z identification has been discussed (C) 2010 Elsevier B V All rights reserved

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Isochronous Mass Spectrometry is a high accurate mass spectrometer. A secondary electrons time detector has been developed and used for mass measurements. Secondary electrons from a thin carbon foil are accelerated by ail electric field and deflected 180 degrees by a magnetic field onto a micro-channel plate. The time detector has been tested with alpha particles and a time resolution of 197 ps (FWHM) was obtained in the laboratory. A mass resolution around 8 x 10(-6) For Delta m/m was achieved by using this time detector in a pilot mass measurement experiment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A method for calibration of an audio-frequency (AF) ion trap mass spectrometer is described. The method is proposed to surmount the obstacle that there is a lack of a proper calibrant for mass spectrometers in the mass-to-charge ratio (m/z) range of 10(6) to 10(10). To calibrate such mass spectra, we determine the point of ejection, q(eject), on the stability diagram of the ion trap operated in a mass-selective axial instability mode. This is accomplished by measuring the radial secular frequencies (and therefore, the m/z value) of a single trapped particle using a light scattering method, followed by monitoring the action of particle ejection in real time to obtain the q(eject). A delayed ejection with q(eject) = 0.949 +/- 0.004 is found at a trap driving frequency of Ohm/2pi = 200-600Hz. Theoretical analysis for the origin of the delayed ejection indicates that the delay is predominantly resulted from the existence of multipole components in the fields due to trap imperfections. Inclusion of -3% of the octopole with respect to the basic quadrupole field can satisfactorily account for our observations. An m/z accuracy approaching 0.1% is attainable after proper calibration of the AF ion trap mass spectrometer. (Int J Mass Spectrom 214 (2002) 63-73) (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In the present study, one- and two-dimensional gel electrophoresis combined with high resolution Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR MS) have been applied as powerful approaches for the proteome analysis of surfactant proteins SP-A and SP-D, including identification of structurally modified and truncation forms, in bronchoalveolar lavage fluid from patients with cystic fibrosis, chronic bronchitis and pulmonary alveolar proteinosis. Highly sensitive micro preparation techniques were developed for matrix-assisted laser desorption/ionization (MALDI) FT-ICR MS analysis which provided the identification of surfactant proteins at very low levels. Owing to the high resolution, FT-ICR MS was found to provide substantial advantages for the structural identification of surfactant proteins from complex biological matrices with high mass determination accuracy. Several protein bands corresponding to SP-A and SP-D were identified by MALDI-FT-ICR MS after electrophoretic separation by one- and two-dimensional gel electrophoresis, and provided the identification of structural modifications (hydroxy-proline) and degradation products.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Sodium dodecyl sulfate(SDS) is a powerful solubilizing detergent which is often used during the separation of highly complex protein mixtures by one- or two-dimensional (2D) gel electrophoresis. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a widely used technique for mass spectrometric analysis of some protein molecules compared to other techniques. But the presence of SDS or some salts usually leads to signal deterioration when using MALDI-MS. A method for using nitrocellulose membrane as the solid-phase carrier combined with n-octyl-beta-D-glucopyranoside in the matrix highly enhances the sensitivity of the molecular mass determination of lysozyme. This technique has the advantage that the signal-to-noise of the molecular weight profile is improved compared with the mass spectrum and the profile is relatively easy to interpret.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fragmentation pathways of aconitine-type alkaloids were investigated by electrospray ionization/ion trap multistage tandem mass spectrometry. Low-energy collision-induced dissociation of protonated aconitines follows a dominant first step, the elimination of the C-8-substituent as acetic acid or fatty acid in MS2 spectra. Successive losses of 1-4 CH3OH molecules, 1-3 H2O, CO, benzoic acid, and CH3 or C2H5 (N-substituents) are all fragmentation pathways observed in MS3 and MS4 spectra. By applying knowledge of these fragmentation pathways to the aconitines in the ethanolic extract of aconite roots, all the known aconitines were detected and also 23 unknown aconitine-type alkaloids, in which the lipo-alkaloids containing residues of 15C, 17C and 19C saturated or unsaturated fatty acids were characterized. These odd-carbon-number fatty acid substituents have not been reported previously.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Procedures that allow the realization of resonance electron capture (REC) mode on a commercial triple-quadrupole mass spectrometer, after some simple modifications, are described, REC mass spectrometry (MS) and tandem mass spectrometry (MS/MS) experiments were performed and spectra for some compounds were recorded. In particular, the charge-remote fragmentation (CRF) spectra of [M - H](-) ions of docosanoic and docosenoic acids under low-energy collisionally activated dissociation (CAD) conditions were obtained, and showed that there were no significant differences for [M - H](-) ions produced at different resonances (i,e. for [M - H](-) ions with different structures). This observation was explained on the basis of results obtained from deuterium-labeled fatty acids, which showed that different CRF ions (but with the same m/z value in the absence of labels) could be produced by different mechanisms, and all of them were obviously realized under CAD conditions that made spectra practically indistinguishable. The other example, which compared the REC-MS/MS spectrum of [M - H](-) ions and EI-MS/MS spectrum of M+. ions of daidzein, demonstrated the potential of the REC-MS/MS technique for more complex structure elucidation. Copyright (C) 2000 John Wiley & Sons, Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Rabies virus was used as the antigen to immunize laying chickens. Anti-rabies virus immunoglobulin Y(IgY) was isolated from yolks of the eggs laid by these chickens using a two-step salt precipitation and one-step gel filtration protocol. The purified IgY was reduced with dithiothreitol, and heavy chains (HC) and light chains (LC) were obtained. In addition, the purified IgY was digested with pepsin and the fragment with specific antigen binding properties (Fab) was produced. Using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOFMS), the average molecular weights of IgY, HC, LC, and Fab were determined as 167 250, 65 105, 18 660, and 45,359 Da, respectively. IgY has two structural differences compared with mammalian IgGs. First, the molecular weight of the heavy chain of IgY is larger than that of its mammalian counterpart, while the molecular weight of the light chain of IgY is smaller. Second, upon pepsin digestion, anti-rabies virus IgY is degraded into Feb, in contrast to mammalian IgG, which has been reported to be degraded into F(ab')(2) under the same conditions. Copyright (C) 2001 John Wiley & Sons, Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Electrospray ionization (ESI) combined with multiple-stage tandem mass spectrometry (MSn) was used to directly analyze the glycolipid mixture from bacteria Bacillus pumilus without preliminary separation. Full scan ESI-MS revealed the composition of picomole quantities of glycerolglycolipid species containing C-14-C-19 fatty acids, some of which were monounsaturated, Two main components were identified from their molecular masses and fragmentation pathways. The fragmentation pathway of the known compound compared with the investigated compound verified the proposed structure as 1(3)-acyl-2-pentadecanoyl-3(1)-O-[beta-D-glucopyranosyl-(1-->6)-O-beta-D-glucopyranosyl]-sn-glycerols. A comparison of the multiple tandem mass spectra of the different alkali-metal cation adducts indicates that the intensity of fragments and the dissociation pathways are dependent on the alkali-metal type, The basic structures of glycerolglycolipids were reflected clearly from the fragmentation patterns of the sodium cations, The intense fragments of the sugar residue from the precursor ions were obtained from the lithiated adduct ions. ESI-MSn spectra of [M + K](+) ions did not provide as much fragmentation as [M + Na](+) and [M + Li](+) adducts, but their spectra allow the position of glycerol acylation to be determined. On the basis of MS2 spectra of[M + K](+) ions, it was established that all components have a C-15:0 fatty acid at the sn-2 position of the glycerol backbone and C-14-C-19 acids at the sn-1 position of the glycerol backbone. Copyright (C) 1999 John Wiley & Sons, Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Three triterpenoid saponins in crude extracts from Acanthopanax senticosus Harms have been investigated by use of multi-stage mass spectrometry (MSn) combined with electrospray ionization (ESI), MSn spectra were applied to direct structure elucidation of these saponins in crude plant extracts, in positive and negative ion mode. The characteristic fragmentations of triterpenoid saponins are discussed. The method provides a means of rapid initial screening of crude plant extracts. Copyright (C) 1999 John Wiley & Sons, Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

X-ray photoelectron spectroscopy and mass spectrometry have been used to study the ten alpha-Amino Acids. The chemical shiftss of N-1s electron binding energy have been explained by means of the difference in the hydrocarbon group of amino acids. The influence of the hydrocarbon group on NH2 has been disscussed using the XPS and MS results.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was used to analyze two enzymes, phospholipase AZ and fibrinolytic enzyme isolated from Chinese Agkistrodon blomhoffii Ussurensis venom. Using sinapinic acid as the matrix, positive ion mass spectra of the enzymes were obtained, In addition to the dominant protein [M+H](+) ions, multimeric and multiply charged ions were also observed in the mass spectra, The higher the concentration of the enzymes, the more multiply charged polymer and multimeric ions were detected, Our results indicate that MALDI-TOFMS can provide a rapid and accurate method for molecular weight determination of snake venom enzymes, Mass accuracies of 0.1 and 0.3 % were achieved by analysis of highly dialyzed phospholipase A2 and fibrinolytic enzyme, and these results are much better than those obtained using sodium dodecyl sulfate-palyacrylamide gel electrophoresis. MALDI-TOFMS thus provides a reliable method to determine the purity and molecular weight of these enzymes, which are of potential use as therapeutants, Copyright (C) 1999 John Wiley & Sons, Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Mass spectra of LaxC2n (x = 1,2), well known endohedral metallofullerenes, and Lu2C2n (2n = 76-112), new members of extractable metallofullerenes, were studied. Positive-ion laser desorption/ionization (LDI) and electron impact (EI) mass spectra indicated that lutetium is a special lanthanide that prefers to form dilutetium fullerenes by the are-burning method. However, the signals for Lu2C2n become very weak in negative-ion LDI-MS, this is different from La-2@C-80, which has close relative abundances in positive- and negative-ion MS. The distinction between Lu2C2n and La-2@C-80 in the negative-ion LDI mass spectra may be due to the different structures of La- and Lu-containing fullerenes. (C) 1997 by John Wiley & Sons, Ltd.