950 resultados para Magnetoacoustic emission


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Left ventricular (LV) volumes have important prognostic implications in patients with chronic ischemic heart disease. We sought to examine the accuracy and reproducibility of real-time 3D echo (RT-3DE) compared to TI-201 single photon emission computed tomography (SPECT) and cardiac magnetic resonance imaging (MRI). Thirty (n = 30) patients (age 62±9 years, 23 men) with chronic ischemic heart disease underwent LV volume assessment with RT-3DE, SPECT, and MRI. Ano vel semi-automated border detection algorithmwas used by RT-3DE. End diastolic volumes (EDV) and end systolic volumes (ESV) measured by RT3DE and SPECT were compared to MRI as the standard of reference. RT-3DE and SPECT volumes showed excellent correlation with MRI (Table). Both RT- 3DE and SPECT underestimated LV volumes compared to MRI (ESV, SPECT 74±58 ml versus RT-3DE 95±48 ml versus MRI 96±54 ml); (EDV, SPECT 121±61 ml versus RT-3DE 169±61 ml versus MRI 179±56 ml). The degree of ESV underestimation with RT-3DE was not significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was decided to investigate field emission from cadmium sulphide because many workers have found that the agreement between theory and experiment for this material, and other semiconductors, is poor. An electron energy analyser, similar to those used in most of the previously reported experiments, was, therefore, built. The performance of the analyser was thoroughly investigated both theoretically and practically and the results of these investigations were used in conjunction with a tungsten emitter. Excellent agreement was obtained between the usually accepted total energy distribution for tungsten and the corresponding .distribution measured with the present analyser. A method of obtaining reliable cadmium sulphide emitter was developed. These emitters were then used in the analyser and it was found that the agreement between theory and experiment was poor. Previous explanations of the lack of agreement are considered and are found to be doubtful. The theory of field emission from semiconductors is reviewed and possible reasons for the discrepancy between theory and experiment are proposed. Finally, further experiments are described which should prove or disprove the conclusions arrived at in this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In an attempt to clarify the behaviour of semi-conductor field emitters the properties of a narrow band gap material were investigated. A retarding potential analyser was built and tested using a tungsten emitter. The energy distribution of electrons emitted from single crystals of lead telluride (band gap 0.3 eV) and gallium phosphide (band gap 2.26 eV) were measured. The halfwidths of the distributions are discussed with respect to the relevant parameters for the materials. Methods of tip preparation had to be developed. The halfwidth of the energy distribution of electrons field emitted from carbon fibres was measured to be 0.21 ± 0.01 eV. A mechanism explaining the long lifetime of the emitters in poor vacuua is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detailed investigation has been undertaken into a field-induced electron emission (FIEE) mechanism that occurs at microscopically localised `sites' on uncoated, dielectric-coated and composite-coated metallic cathodes. An optical imaging technique has been used to observe and characterize the spatial and temporal behaviour of the populations of emission sites on these cathodes under various experimental conditions, e.g. pulsed-fields, gas environment etc. This study has shown that, for applied fields of 20MVm^-1, thin dielectric (750AA) and composite metal-insulator (MI) overlayers result in a dramatic increase in the total number of emission sites (typically 30cm^-2), and hence emission current. The emission process has been further investigated by a complementary electron spectroscopy technique which has revealed that the localised emission sites on these cathodes display field-dependent spectral shifts and half-widths, i.e. indicative of a `non-metallic' emission mechanism. Details are also given of a comprehensive investigation into the effects of the residual gas environment on the FIEE process from uncoated Cu-cathodes. This latter study has revealed that the well-known Gas Conditioning process can be performed with a wide range of gas species (e.g. O_2, N_2 etc), and furthermore, the degree of conditioning is influenced by both a `Voltage' and `Temperature' effect. These experimental findings have been shown to be particularly important to the technology of high-voltage vacuum-insulation and cold-cathode electron sources. The FIEE mechanism has been interpreted in terms of a hot-electron process that is associated with `electroformed' conducting channels in MI, MIM and MIMI surface microstructures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work describes the development of a proton induced X-ray emission (PIXE) analysis system, especially designed and builtfor routine quantitative multi-elemental analysis of a large number of samples. The historical and general developments of the analytical technique and the physical processes involved are discussed. The philosophy, design, constructional details and evaluation of a versatile vacuum chamber, an automatic multi-sample changer, an on-demand beam pulsing system and ion beam current monitoring facility are described.The system calibration using thin standard foils of Si, P, S,Cl, K, Ca, Ti, V, Fe, Cu, Ga, Ge, Rb, Y and Mo was undertaken at proton beam energies of 1 to 3 MeV in steps of 0.5 MeV energy and compared with theoretical calculations. An independent calibration check using bovine liver Standard Reference Material was performed.  The minimum detectable limits have been experimentally determined at detector positions of 90° and 135° with respect to the incident beam for the above range of proton energies as a function of atomic number Z. The system has detection limits of typically 10- 7 to 10- 9 g for elements 14