994 resultados para Low-emission windows
Resumo:
The prevalence of TT virus (TTV) infection was investigated by Polymerase Chain Reaction (PCR) in low- (blood donors and healthy children/adolescents) and high-risk (hemophiliacs) groups from São Paulo, Brazil. Primers based on the untranslated region (UTR) of the viral genome proved to be much more ubiquitous, leading to much higher frequencies for both groups ( > or = 81%) than the earlier N22-PCR directed to the open reading frame 1 (blood donors, 5.5%, and hemophiliacs, 42.3%). The UTR-PCR also revealed an interesting profile for healthy children/adolescents: very high prevalence at the early years and significant decrease in male teenagers. The N22-PCR, in turn, demonstrated higher frequency in hemophiliacs treated with fresh blood products (58%), than in those treated with virus-inactivated clotting factors (9.4%) and blood donors (5.5%).
Resumo:
Ergonomic interventions such as increased scheduled breaks or job rotation have been proposed to reduce upper limb muscle fatigue in repetitive low-load work. This review was performed to summarize and analyze the studies investigating the effect of job rotation and work-rest schemes, as well as, work pace, cycle time and duty cycle, on upper limb muscle fatigue. The effects of these work organization factors on subjective fatigue or discomfort were also analyzed. This review was based on relevant articles published in PubMed, Scopus and Web of Science. The studies included in this review were performed in humans and assessed muscle fatigue in upper limbs. 14 articles were included in the systematic review. Few studies were performed in a real work environment and the most common methods used to assess muscle fatigue were surface electromyography (EMG). No consistent results were found related to the effects of job rotation on muscle activity and subjective measurements of fatigue. Rest breaks had some positive effects, particularly in perceived discomfort. The increase in work pace reveals a higher muscular load in specific muscles. The duration of experiments and characteristics of participants appear to be the factors that most have influenced the results. Future research should be focused on the improvement of the experimental protocols and instrumentation, in order to the outcomes represent adequately the actual working conditions. Relevance to industry: Introducing more physical workload variation in low-load repetitive work is considered an effective ergonomic intervention against muscle fatigue and musculoskeletal disorders in industry. Results will be useful to identify the need of future research, which will eventually lead to the adoption of best industrial work practices according to the workers capabilities.
Resumo:
Radio link quality estimation is essential for protocols and mechanisms such as routing, mobility management and localization, particularly for low-power wireless networks such as wireless sensor networks. Commodity Link Quality Estimators (LQEs), e.g. PRR, RNP, ETX, four-bit and RSSI, can only provide a partial characterization of links as they ignore several link properties such as channel quality and stability. In this paper, we propose F-LQE (Fuzzy Link Quality Estimator, a holistic metric that estimates link quality on the basis of four link quality properties—packet delivery, asymmetry, stability, and channel quality—that are expressed and combined using Fuzzy Logic. We demonstrate through an extensive experimental analysis that F-LQE is more reliable than existing estimators (e.g., PRR, WMEWMA, ETX, RNP, and four-bit) as it provides a finer grain link classification. It is also more stable as it has lower coefficient of variation of link estimates. Importantly, we evaluate the impact of F-LQE on the performance of tree routing, specifically the CTP (Collection Tree Protocol). For this purpose, we adapted F-LQE to build a new routing metric for CTP, which we dubbed as F-LQE/RM. Extensive experimental results obtained with state-of-the-art widely used test-beds show that F-LQE/RM improves significantly CTP routing performance over four-bit (the default LQE of CTP) and ETX (another popular LQE). F-LQE/RM improves the end-to-end packet delivery by up to 16%, reduces the number of packet retransmissions by up to 32%, reduces the Hop count by up to 4%, and improves the topology stability by up to 47%.
Resumo:
The wide use of antibiotics in aquaculture has led to the emergence of resistant microbial species. It should be avoided/minimized by controlling the amount of drug employed in fish farming. For this purpose, the present work proposes test-strip papers aiming at the detection/semi-quantitative determination of organic drugs by visual comparison of color changes, in a similar analytical procedure to that of pH monitoring by universal pH paper. This is done by establishing suitable chemical changes upon cellulose, attributing the paper the ability to react with the organic drug and to produce a color change. Quantitative data is also enabled by taking a picture and applying a suitable mathematical treatment to the color coordinates given by the HSL system used by windows. As proof of concept, this approach was applied to oxytetracycline (OXY), one of the antibiotics frequently used in aquaculture. A bottom-up modification of paper was established, starting by the reaction of the glucose moieties on the paper with 3-triethoxysilylpropylamine (APTES). The so-formed amine layer allowed binding to a metal ion by coordination chemistry, while the metal ion reacted after with the drug to produce a colored compound. The most suitable metals to carry out such modification were selected by bulk studies, and the several stages of the paper modification were optimized to produce an intense color change against the concentration of the drug. The paper strips were applied to the analysis of spiked environmental water, allowing a quantitative determination for OXY concentrations as low as 30 ng/mL. In general, this work provided a simple, method to screen and discriminate tetracycline drugs, in aquaculture, being a promising tool for local, quick and cheap monitoring of drugs.
Resumo:
Increased levels of plasma oxLDL, which is the oxidized fraction of Low Density Lipoprotein (LDL), are associated with atherosclerosis, an inflammatory disease, and the subsequent development of severe cardiovascular diseases that are today a major cause of death in modern countries. It is therefore important to find a reliable and fast assay to determine oxLDL in serum. A new immunosensor employing three monoclonal antibodies (mAbs) against oxLDL is proposed in this work as a quick and effective way to monitor oxLDL. The oxLDL was first employed to produce anti-oxLDL monoclonal antibodies by hybridoma cells that were previously obtained. The immunosensor was set-up by selfassembling cysteamine (Cyst) on a gold (Au) layer (4 mm diameter) of a disposable screen-printed electrode. Three mAbs were allowed to react with N-hydroxysuccinimide (NHS) and ethyl(dimethylaminopropyl)carbodiimide (EDAC), and subsequently incubated in the Au/Cys. Albumin from bovine serum (BSA) was immobilized further to ensure that other molecules apart from oxLDL could not bind to the electrode surface. All steps were followed by various characterization techniques such as electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The analytical operation of the immunosensor was obtained by incubating the sensing layer of the device in oxLDL for 15 minutes, prior to EIS and SWV. This was done by using standard oxLDL solutions prepared in foetal calf serum, in order to simulate patient's plasma with circulating oxLDL. A sensitive response was observed from 0.5 to 18.0 mg mL 1 . The device was successfully applied to determine the oxLDL fraction in real serum, without prior dilution or necessary chemical treatment. The use of multiple monoclonal antibodies on a biosensing platform seemed to be a successful approach to produce a specific response towards a complex multi-analyte target, correlating well with the level of oxLDL within atherosclerosis disease, in a simple, fast and cheap way.
Resumo:
Sulfadimethoxine (SDM) is one of the drugs, often used in the aquaculture sector to prevent the spread of disease in freshwater fish aquaculture. Its spread through the soil and surface water can contribute to an increase in bacterial resistance. It is therefore important to control this product in the environment. This work proposes a simple and low-cost potentiometric device to monitor the levels of SDM in aquaculture waters, thus avoiding its unnecessary release throughout the environment. The device combines a micropipette tip with a PVC membrane selective to SDM, prepared from an appropriate cocktail, and an inner reference solution. The membrane includes 1% of a porphyrin derivative acting as ionophore and a small amount of a lipophilic cationic additive (corresponding to 0.2% in molar ratio). The composition of the inner solution was optimized with regard to the kind and/or concentration of primary ion, chelating agent and/or a specific interfering charged species, in different concentration ranges. Electrodes constructed with inner reference solutions of 1 × 10−8 mol/L SDM and 1 × 10−4 mol/L chromate ion showed the best analytical features. Near-Nernstian response was obtained with slopes of −54.1 mV/decade, an extraordinary detection limit of 7.5 ng/mL (2.4 × 10−8 mol/L) when compared with other electrodes of the same type. The reproducibility, stability and response time are good and even better than those obtained by liquid contact ISEs. Recovery values of 98.9% were obtained from the analysis of aquaculture water samples.
Resumo:
12th European Conference on Wireless Sensor Networks (EWSN 2015). 9 to 11, Feb, 2015. Porto, Portugal
Resumo:
Currently, due to the widespread use of computers and the internet, students are trading libraries for the World Wide Web and laboratories with simulation programs. In most courses, simulators are made available to students and can be used to proof theoretical results or to test a developing hardware/product. Although this is an interesting solution: low cost, easy and fast way to perform some courses work, it has indeed major disadvantages. As everything is currently being done with/in a computer, the students are loosing the “feel” of the real values of the magnitudes. For instance in engineering studies, and mainly in the first years, students need to learn electronics, algorithmic, mathematics and physics. All of these areas can use numerical analysis software, simulation software or spreadsheets and in the majority of the cases data used is either simulated or random numbers, but real data could be used instead. For example, if a course uses numerical analysis software and needs a dataset, the students can learn to manipulate arrays. Also, when using the spreadsheets to build graphics, instead of using a random table, students could use a real dataset based, for instance, in the room temperature and its variation across the day. In this work we present a framework which uses a simple interface allowing it to be used by different courses where the computers are the teaching/learning process in order to give a more realistic feeling to students by using real data. A framework is proposed based on a set of low cost sensors for different physical magnitudes, e.g. temperature, light, wind speed, which are connected to a central server, that the students have access with an Ethernet protocol or are connected directly to the student computer/laptop. These sensors use the communication ports available such as: serial ports, parallel ports, Ethernet or Universal Serial Bus (USB). Since a central server is used, the students are encouraged to use sensor values results in their different courses and consequently in different types of software such as: numerical analysis tools, spreadsheets or simply inside any programming language when a dataset is needed. In order to do this, small pieces of hardware were developed containing at least one sensor using different types of computer communication. As long as the sensors are attached in a server connected to the internet, these tools can also be shared between different schools. This allows sensors that aren't available in a determined school to be used by getting the values from other places that are sharing them. Another remark is that students in the more advanced years and (theoretically) more know how, can use the courses that have some affinities with electronic development to build new sensor pieces and expand the framework further. The final solution provided is very interesting, low cost, simple to develop, allowing flexibility of resources by using the same materials in several courses bringing real world data into the students computer works.
Resumo:
This paper reports the design of a new remotely operated underwater vehicle (ROV), which has been developed at the Underwater Systems and Technology Laboratory (USTL) - University of Porto. This design is contextualized on the KOS project (Kits for underwater operations). The main issues addressed here concern directional drag minimization, symmetry, optimized thruster positioning, stability and layout of ROV components. This design is aimed at optimizing ROV performance for a set of different operational scenarios. This is achieved through modular configurations which are optimized for each different scenario.
Resumo:
The pathogenesis of the renal lesion upon envenomation by snakebite has been related to myolysis, hemolysis, hypotension and/or direct venom nephrotoxicity caused by the venom. Both primary and continuous cell culture systems provide an in vitro alternative for quantitative evaluation of the toxicity of snake venoms. Crude Crotalus vegrandis venom was fractionated by molecular exclusion chromatography. The toxicity of C. vegrandis crude venom, hemorrhagic, and neurotoxic fractions were evaluated on mouse primary renal cells and a continuous cell line of Vero cells maintained in vitro. Cells were isolated from murine renal cortex and were grown in 96 well plates with Dulbecco's Modified Essential Medium (DMEM) and challenged with crude and venom fractions. The murine renal cortex cells exhibited epithelial morphology and the majority showed smooth muscle actin determined by immune-staining. The cytotoxicity was evaluated by the tetrazolium colorimetric method. Cell viability was less for crude venom, followed by the hemorrhagic and neurotoxic fractions with a CT50 of 4.93, 18.41 and 50.22 µg/mL, respectively. The Vero cell cultures seemed to be more sensitive with a CT50 of 2.9 and 1.4 µg/mL for crude venom and the hemorrhagic peak, respectively. The results of this study show the potential of using cell culture system to evaluate venom toxicity.
Resumo:
The aim of the present study was to investigate variations in oxidized LDL (oxLDL) at the onset of acute myocardial infarction (AMI) and over the recovery period, exploring their relationship with coronary disease severity. A follow-up of 50 AMI patients was evaluated against 25 healthy volunteers (reference group). The AMI patients were evaluated at three time points: at admission before the administration of IIb/IIIa inhibitors and angioplasty, and two and 40 days after intervention. Plasma oxLDL concentrations were measured by ELISA. oxLDL was found to be significantly higher in AMI patients in the acute phase relative to reference levels, decreasing progressively over the recovery period. The results also demonstrated that oxLDL levels were decreased in patients with the left circumflex artery (LCX) as culprit vessel compared to the left anterior descending coronary (LAD) or right coronary artery (RCA). The results highlight a significant increase in oxLDL concentration related to coronary artery disease severity, as conditions such as LCX lesions are usually associated with a favorable prognosis, contrasting with LAD-associated conditions that can compromise large areas of myocardium. The results thus suggest that oxLDL may constitute a promising marker in assessment of AMI evolution.
Resumo:
This work presents a low cost RTK-GPS system for localization of unmanned surface vehicles. The system is based on the use of standard low cost L1 band receivers and in the RTKlib open source software library. Mission scenarios with multiple robotic vehicles are addressed as the ones envisioned in the ICARUS search and rescue case where the possibility of having a moving RTK base on a large USV and multiple smaller vehicles acting as rovers in a local communication network allows for local relative localization with high quality. The approach is validated in operational conditions with results presented for moving base scenario. The system was implemented in the SWIFT USV with the ROAZ autonomous surface vehicle acting as a moving base. This setup allows for the performing of a missions in a wider range of environments and applications such as precise 3D environment modeling in contained areas and multiple robot operations.
Resumo:
Toxoplasmosis is one of the most common zoonoses worldwide. The seroprevalence for T. gondii in human population from Brazil might range from 40 to 80%. The aim of this paper was to study the seroprevalence of T. gondii infection in children from age one to 15 living in a low socioeconomic community, named community of Jardim São Remo in the year of 2002. The community is located in the West area of São Paulo municipality, São Paulo State, Brazil. Antibodies to T. gondii were found in 110 (32.4%, CI 95%: 27.5 - 37.7) of the 339 children tested with indirect immunofluorescent antibody test. The titration of the samples revealed 29 children with serum titer equal to 16, 14 children with 32, 18 children with 64, 21 children with 128, 20 children with 256 and eight children with serum titer > 512. The age dependence of the prevalence of T. gondii infection and the association between seroprevalence for T. gondii and seroprevalence for T. canis suggest that the infection is chiefly postnatal. Seroconversion in infant population of community Jardim São Remo occurs in children as young as two years old, earlier than in the children attended at health centers of São Paulo city. The seroprevalence of T. gondii in children from Jardim São Remo was compared to the prevalence in children from other urban centers of Brazil.
Resumo:
Um dos objetivos desta dissertação de mestrado foi avaliar o impacto ambiental do processo de tingimento usado na indústria de curtumes, em termos de volume de efluente produzido e sua carga poluente. Pretendeu-se também encontrar alternativas ao nível do processo de tingimento que levem a uma melhoria na qualidade do efluente produzido. Outro objetivo deste trabalho foi avaliar o funcionamento da ETAR existente na empresa JR Fontes, no que diz respeito aos parâmetros em estudo (carência química de oxigénio - CQO, pH, crómio e teor de sólidos suspensos totais - SST), propondo alterações que permitam respeitar os valores de emissão exigidos na licença de descarga da empresa. Verificou-se que o processo de tingimento aplicado pela empresa JR Fontes é muito poluente, em termos de carga orgânica e matéria em suspensão. Este facto é comprovado pelos resultados obtidos para os três processos estudados: Montana, Galáctico e Navak. Todos os processos apresentam um efluente com pH ácido (aproximado a 3) e valores de CQO superiores a 3550 mg O2/L, sendo o processo Navak aquele que apresenta o valor mais alto para o banho composto, 8362 mg O2/L. Relativamente ao teor de crómio, o banho de recurtume com concentração mais elevada de crómio total é o banho 1 do processo Navak, com 2297 mg/L, sendo que a concentração destes banhos é sempre elevada, igual ou superior a 746 mg/L. No que diz respeito à matéria em suspensão, o processo Navak é novamente o mais poluente, com um valor de 3842 mg SST/L, não sendo obtidos nos outros processos, valores inferiores a 1205 mg SST/L. Na realização de um processo alternativo de tingimento verificou-se que é possível diminuir a carga orgânica do efluente originado. A aplicação de recurtumes sintéticos deu origem a efluentes menos poluentes. O melhor valor obtido para a CQO foi de 1113 mg O2/L, sendo obtidos valores não superiores a 7185 mg O2/L para processos de características semelhantes aos aplicados nesta indústria. Relativamente à ETAR, apesar das restrições ao funcionamento que esta apresenta, no geral pode ser considerada eficiente, embora não consiga atingir o objetivo pretendido de remoção para a CQO, ou seja o valor de 1100 mg O2/L. Nos restantes parâmetros é cumprido o limite de emissão (350 mg SST/L, pH entre 6 e 9 e 2 mg Cr/L para o crómio total): os SST apresentam o valor de 98 mg SST/L, o crómio total de 1,2 mg Cr/L e o pH encontra-se entre 8 e 9. São aqui feitas duas abordagens para solucionar os problemas existentes na ETAR. A primeira considera um ajuste no tratamento e equipamentos existentes, através da reconstrução do tanque de equalização, da substituição do coagulante por sulfato ferroso e da reconstrução do sedimentador, assim como a substituição das tubagens por umas de maior diâmetro, solucionando assim problemas de manutenção de toda a instalação e do incumprimento da legislação. A outra abordagem implica a substituição do sistema de afinação existente, os filtros de areia e carvão ativados, por um sistema de membranas de ultrafiltração ou por dois filtros de carvão ativado. Para tratar um efluente com um valor de CQO de 3000 mg O2/L com o carvão estudado, seriam necessários 132 kg de carvão por coluna, aproveitando-se os equipamentos existentes. No caso das membranas filtrantes, estas são eficazes, reduzindo a CQO em cerca de 70%. Ao contrário do carvão, a aplicação deste sistema implicaria a aquisição de novos equipamentos. Futuramente propõe-se a avaliação dos vários tipos de reagentes usados no tingimento de couro de forma a aplicar no tratamento aqueles que produzam as características desejadas no produto final e a que apresentem um menor resultado de CQO. Propõe-se também o estudo de viabilidade da remoção de crómio dos banhos de recurtume e consequente avaliação da aplicabilidade de um tratamento biológico em substituição ou como complemento do tratamento existente.
Resumo:
An open trial to evaluate the azithromycin efficacy in cutaneous leishmaniasis patients was carried out in Manaus (AM), where Leishmania (Viannia) guyanensis is the main etiologic agent. Forty-one patients with skin lesions of less than 12 weeks duration, without specific treatment for the last three months and a positive imprint to Leishmania sp. were included. From these, 31 (75.6%) were male with median age of 30.2. All of them received a daily-single oral dose of 500 mg of azithromycin for ten days. At 25th day, 16 (39%) presented therapeutic failure and received intramuscular pentavalent antimonial, four were considered lost, 21, that had improved or were inaltered received another ten-day series of azithromycin and were monthly followed, but nine (21.9%) of them presented a poor clinical response and switched to intramuscular pentavalent antimonial on day 55. Of the 12 remaining cases evaluated on day 55, despite of clinical improvement, three asked for antimony therapy and 9 (21.9%) continued the follow-up but, only three were cured on 55th, 85th and 115th days, and six did not come back for final evaluation. The intention-treatment overall response rate was 22% and whole cure was seen in three (7.3%) of cases. Thus, azithromycin showed a low efficacy to treat cutaneous leishmaniasis in Manaus.