981 resultados para Loosely packed array
Resumo:
Multiparametric Magnetic Resonance Imaging has been increasingly used for detection, localization and staging of prostate cancer over the last years. It combines high-resolution T2 Weighted-Imaging and at least two functional techniques, which include Dynamic Contrast–Enhanced Magnetic Resonance Imaging, Diffusion-Weighted Imaging, and Magnetic Resonance Imaging Spectroscopy. Although the combined use of a pelvic phased-array and an Endorectal Coil is considered the state-of-the-art for Magnetic Resonance Imaging evaluation of prostate cancer, Endorectal Coil is only absolute mandatory for Magnetic Resonance Imaging Spectroscopy at 1.5 T. Sensitivity and specificity levels in cancer detection and localization have been improving with functional technique implementation, compared to T2 Weighted-Imaging alone. It has been particularly useful to evaluate patients with abnormal PSA and negative biopsy. Moreover, the information added by the functional techniques may correlate to cancer aggressiveness and therefore be useful to select patients for focal radiotherapy, prostate sparing surgery, focal ablative therapy and active surveillance. However, more studies are needed to compare the functional techniques and understand the advantages and disadvantages of each one. This article reviews the basic principles of prostatic mp-Magnetic Resonance Imaging, emphasizing its role on detection, staging and active surveillance of prostate cancer.
Resumo:
Dissertação para obtenção do Grau de Doutor em Engenharia Química e Bioquímica
Resumo:
The development of integrated measures which involve sterile mate release to supplement the conventional insecticidal techniques used in controlagainst insects of medical importance, raised the question, whether the vectors of Chagas'disease possess the natural mechanisms by manipulation of which they may be controlled. Results of earlier expenments, that had been published previously, were restricted to fragmentary information that raised various questions, the answer to which became available in the study herein described. Interspecific hybrids were produced from reciprocal crosses between T. pseudomaculata and T. sórdida and from unilateral crosses between female T. pseudomaculata and male. T. infestans. These females mated with males, laid less than the normal complement of eggs, but offspring was relatively abundant. When T. pseudomaculata females were paired with T. brasiliensis males, hybridization was more difficult because few of the females mated and those that did had a strongly reduced fertility. Adults emerged from ali crosses but exhibited sex disproportion, females predominating in all populations but one. The two Rhodnius species tested were also found to cross, but only when female R. prolixus were paired with male R. neglectus. These females laid a relatively high complement o f eggs, had a strongly reduced fertility, but 50% of the fertile eggs developed into vigorous adults, males predominating females. Neither type of hybrid male elicited fertilized eggs from either parental type of female, through their vesicula seminal is were found to be packed with spermatozoa, some normal looking and moving, others underdeveloped and motionless. Although, no artificial insemination was performed, the sperm in itself did not appear to be the prime inducer of sterility. Females paired with these hybrids did mate, sperm was transfered, as evidenced by the discharged spermatophores smeared with sperm, but did notcontain spermatozoa in their spermatecae. The failure of the sperm to migrate to the spermatecae indicate prezygotic pos-copulation incompatibility, thus the hybrid male can't be used to suppress populations. The female hybrids mated with parent males of either species had reduced fertility and ther sons were sterile as were those of their fertile daughters. However, continous backcrossing of the hybrid females and their female progeny to parental males partially restored fertility of the males and increased fertility of females, as scored by egg hatchability. Fertility of hybrid females, measured by the yield of adults capable to reproduce, indicated that the reproductive perfomance decreased when hybrid females and their daughters were backcrossed additional generations to parental males. It is tentatively suggested that hybrid females could be used for suppression if they compete efficiently with wild females.
Resumo:
Leber Congenital Amaurosis (LCA), the most severe inherited retinal dystrophy, is genetically heterogeneous, with 14 genes accounting for 70% of patients. Here, 91 LCA probands underwent LCA chip analysis and subsequent sequencing of 6 genes (CEP290, CRB1, RPE65, GUCY2D, AIPL1and CRX), revealing mutations in 69% of the cohort, with major involvement of CEP290 (30%). In addition, 11 patients with early-onset retinal dystrophy (EORD) and 13 patients with Senior-Loken syndrome (SLS), LCA-Joubert syndrome (LCA-JS) or cerebello-oculo-renal syndrome (CORS) were included. Exhaustive re-inspection of the overall phenotypes in our LCA cohort revealed novel insights mainly regarding the CEP290-related phenotype. The AHI1 gene was screened as a candidate modifier gene in three patients with the same CEP290 genotype but different neurological involvement. Interestingly, a heterozygous novel AHI1 mutation, p.Asn811Lys, was found in the most severely affected patient. Moreover, AHI1 screening in five other patients with CEP290-related disease and neurological involvement revealed a second novel missense variant, p.His758Pro, in one LCA patient with mild mental retardation and autism. These two AHI1 mutations might thus represent neurological modifiers of CEP290-related disease.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
With the purpose of standardization of an hemoculture technique presenting a higher positive rate in the parasitological diagnosis of chronic Chagas' disease in patients with reactive serology (IFT, HA, CFT) the following schedule was used. Thirty ml of venous blood was collected with heparin and the plasma was separated by centrifugation (2.000 rpm/30'). The packed cells were washed with LIT medium or PBS which was then removed by centrifugation (2.000 rpm/15'). This material was sampled in 6 screw-tubes 18x200 with 6 ml of LIT medium and incubated at 28°C. These incubated cultures at 28°C were examined after 15, 30, 45 and 60 days. When the hemoculture was not immediately processed after blood collection, the plasma was removed and the sediment enriched with LIT medium and preserved at 4°C. The Xenodiagnosis was performed according to Schenones method used here as a reference technique. Among the various groups of patients examined by both techniques the best results obtained were: 55.08% ofpositivity for hemocultures against 27.5% forxenodiagnosis (X² = 4.54, p = 0.05), with a tubepositivity of 26.6%. Recommendation for screening trials of drug assays is the repetition of method on a same patient 2 or more times in different occasions, as used in xenodiagnosis.
Resumo:
Dissertação para obtenção do Grau de Doutor em Química Sustentável
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
White cell (WBC)-reduction filters have been shown to be effective in removing infectious agents from infected blood products. In this study, the mechanisms of Trypanosoma cruzi (T. cruzi) retention by WBC-reduction filters were assessed. Human packed red blood cell (PRBC) and platelet concentrate (PC) samples were contaminated with T. cruzi organisms (Y strain; 3.4 x 10(6)/ml), and then filtered using WBC-reduction experimental filters that provided about 3 log10 WBC removal. Transmission electron microscopy sections showed that T. cruzi parasites were removed from contaminated PRBC and PC samples primarily by mechanical mechanism without interacting with filter fibbers or blood cells. In addition, we found that T. cruzi parasites were also removed by a direct fibber adhesion. These data indicate that T. cruzi parasites are removed from infected blood not only by mechanical mechanism but also by biological mechanism probably mediated by parasite surface proteins.
Resumo:
Hydrogen sulphide is one of the most toxic and corrosive compound present in swine-derived biogas streams.In this study, afield scale biotrickling filter for the removal of hydrogen sulfide was investigated.A Biofilter packed with supporting biofilm materials was fed continuously with a proprietary nutrient solution and operatedfor over 73days. The system has been operating with a H2S inlet concentrations ranging from 1,000to 3,000 ppm.Significant removal efficiencies >95% was demonstrated. pH of the stock feeding solution decreased from 6.2 to as low as 3.5within couple days.The resulting drop in pH provided circumstantial evidence to support biological H2 Soxidation to sulphuric acid by sulfide-oxidizers. Sulfur precipitation was also observed to occur. The results suggested that H2S removal from biogas stream can be efficiently achieved using portable, low cost and maintenance free biotrickling filters.
Resumo:
Dissertation presented to obtain the Ph.D degree in Biochemistry, Structural Biochemistry
Resumo:
Dissertação para obtenção de Grau de Mestre em Microbiologia Médica pela Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Informática
Resumo:
Nowadays, existing 3D scanning cameras and microscopes in the market use digital or discrete sensors, such as CCDs or CMOS for object detection applications. However, these combined systems are not fast enough for some application scenarios since they require large data processing resources and can be cumbersome. Thereby, there is a clear interest in exploring the possibilities and performances of analogue sensors such as arrays of position sensitive detectors with the final goal of integrating them in 3D scanning cameras or microscopes for object detection purposes. The work performed in this thesis deals with the implementation of prototype systems in order to explore the application of object detection using amorphous silicon position sensors of 32 and 128 lines which were produced in the clean room at CENIMAT-CEMOP. During the first phase of this work, the fabrication and the study of the static and dynamic specifications of the sensors as well as their conditioning in relation to the existing scientific and technological knowledge became a starting point. Subsequently, relevant data acquisition and suitable signal processing electronics were assembled. Various prototypes were developed for the 32 and 128 array PSD sensors. Appropriate optical solutions were integrated to work together with the constructed prototypes, allowing the required experiments to be carried out and allowing the achievement of the results presented in this thesis. All control, data acquisition and 3D rendering platform software was implemented for the existing systems. All these components were combined together to form several integrated systems for the 32 and 128 line PSD 3D sensors. The performance of the 32 PSD array sensor and system was evaluated for machine vision applications such as for example 3D object rendering as well as for microscopy applications such as for example micro object movement detection. Trials were also performed involving the 128 array PSD sensor systems. Sensor channel non-linearities of approximately 4 to 7% were obtained. Overall results obtained show the possibility of using a linear array of 32/128 1D line sensors based on the amorphous silicon technology to render 3D profiles of objects. The system and setup presented allows 3D rendering at high speeds and at high frame rates. The minimum detail or gap that can be detected by the sensor system is approximately 350 μm when using this current setup. It is also possible to render an object in 3D within a scanning angle range of 15º to 85º and identify its real height as a function of the scanning angle and the image displacement distance on the sensor. Simple and not so simple objects, such as a rubber and a plastic fork, can be rendered in 3D properly and accurately also at high resolution, using this sensor and system platform. The nip structure sensor system can detect primary and even derived colors of objects by a proper adjustment of the integration time of the system and by combining white, red, green and blue (RGB) light sources. A mean colorimetric error of 25.7 was obtained. It is also possible to detect the movement of micrometer objects using the 32 PSD sensor system. This kind of setup offers the possibility to detect if a micro object is moving, what are its dimensions and what is its position in two dimensions, even at high speeds. Results show a non-linearity of about 3% and a spatial resolution of < 2µm.