961 resultados para Irradiated seafood
Resumo:
The aim of the present study was to determine the action of AsGA laser irradiation on bone repair in the tibia of osteopenic rats. The animals were randomly divided into eight experimental groups according to the presence of ovarian hormone (sham group) or the absence of the hormone (OVX group), as well as being irradiated or non-irradiated. Low-level 904-nm laser (50 mJ/cm(2)) accelerated the repair process of osteopenic fractures, especially in the initial phase of bone regeneration.Introduction The development of new techniques to speed the process of bone repair has provided significant advances in the treatment of fractures. Some attention recently focused on the effects of biostimulation on bone.Methods Forty-eight adult rats were randomly divided into eight experimental groups (six animals in each group) according to the presence of ovarian hormone (sham group) or absence of the hormone (ovariectomized (OVX) group) as well as being irradiated or non-irradiated. For the application of low-level laser therapy, the animals were anesthetized with one third of the dose sufficient to immobilize the animal and irradiated with AsGa laser (904 nm, 50 mJ/cm(2) for 2s, point form and in contact). The control animals received the same type of manipulation as the irradiated animals, but with the laser turned off. Half of the animals were killed 7 days following the confection of the bone defect, and the other half were killed 21 days after the surgery. After complete demineralization, the tibias were cut cross-sectionally in the central region of the bone defect and embedded in paraffin blocks. The blocks were then cut in semi-seriated slices and stained with hematoxylin and eosin.Results There was new bone formation in the animals in the OVX group with laser treatment killed after 7 days (p<0.001). The lowest percentage of bone formation was observed in the OVX without laser killed after 7 days (p>0.05). All animals killed after 21 days exhibited linear closure of the lesion.Conclusion Low-level 904-nm laser (50 mJ/cm(2)) accelerated the repair process of osteopenic fractures, especially in the initial phase of bone regeneration.
Resumo:
Objectives. This study aimed to assess the apical surface morphology of maxillary central incisors resected 3.0 mm from the tooth apex using Zekrya burs or Er:YAG laser, with or without subsequent direct Nd:YAG laser irradiation (apical and buccal surfaces) and indirect irradiation (palatal surface).Study design. Forty maxillary central incisors were instrumented and obturated. The roots were divided into 4 groups according to the root resection method (Zekrya bur or Er: YAG laser -1.8 W, 450 mJ, 4 Hz, 113 J/cm(2)) and further surface treatment (none or Nd: YAG laser -2.0 W, 100 mJ, 20 Hz, 124 J/cm(2)). The teeth were prepared for SEM analysis. Scores ranging from 1 to 4 were attributed to cut quality and morphological changes. The data were analyzed by the Kruskal-Wallis test and by Dunn's test.Results. SEM images showed irregular surfaces on the apical portions resected with Zekrya burs, with smear layer and grooves in the resected dentine and slight gutta-percha displacement and plasticization. on the other hand, apicectomies carried out with Er: YAG laser showed morphological changes compatible with ablated dentine, with rough surfaces and craters. In spite of the presence of plasticized gutta-percha, with the presence of bubbles, an irregular adaptation of the filling material to the root walls was also observed. Direct Nd: YAG laser irradiation of the apical and buccal surfaces of the resected roots resulted in areas of resolidification and fusion in the dentine and cementum, with a vitrified aspect; indirect Nd: YAG laser irradiation of the palatal surfaces yielded a lower number of changes in the cementum, with irregular resolidification areas.Conclusions. There were no differences in terms of cut quality between the use of burs and Er: YAG laser or between the 2 surfaces (apical and buccal) treated with Nd: YAG laser with direct irradiation. However, morphological changes were significantly less frequent on surfaces submitted to indirect irradiation (palatal) when compared with those directly irradiated. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e77-e82)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Antibody fluorescent tests were carried out with serum and blood eluates from mice inoculated with different doses of irradiated (90 krad) and non irradiated T. cruzi culture forms. Non irradiated culture forms were more efficient immunogens than the irradiated ones. About 75% of the animals inoculated with non irradiated forms showed titers equal or higher than 1/16, the highest one reaching 1/64.
Resumo:
Two wafers of the NIST (formerly NBS) glass standard SRM 612 recently irradiated have been compared to the pre-irradiated wafers RT3 and RT4 of glass SRM 962-7, stored for 9 years at 5°C, and SRM 962, stored for 20 years at room temperature. Track area densities on internal surfaces of the glass as well as track size measurements suggest that (1) the old SRM 962 and the more recent SRM 962a calibrations are consistent and (2) annealing of the fission tracks in the pre-irradiated wafers is negligible. This last experimental result enables a direct comparison of contemporary and previous fission track age calibrations. © 1995.
Resumo:
Thin uranium films built on muscovite mica basis and obsidian samples having known ages were irradiated with thermal neutrons at the IPEN/CNEN reactor, São Paulo. Comparing thin film performance with the obsidian one, it was observed that the latter feel a greater neutron fluence. Nominal fluences at the used facility are in agreement with the results obtained analysing the obsidian samples. A probable hypothesis to explain this disagreement, namely, the uranium loss from the thin films, was ruled out. © 1995.
Resumo:
Thin films of chemically synthesized polyaniline and poly(o-methoxyaniline) were exposed to ionizing X-ray radiation and characterized by radiation induced conductivity measurements, ultraviolet-visible spectroscopy, electron paramagnetic resonance, electrical conductivity and solubility measurements. Samples irradiated in vacuum or dry Oxygen atmosphere did not have their electronic spectra changed. However, under humid atmosphere the energy of the excitonic transition was decreased and accompanied by a great conductivity increase. The results indicate that doping of polyaniline can be induced by X-ray radiation which might be of great interest for applications on lithography and microelectronics.
Resumo:
Non-linear absorption is observed in Er3+-doped fluoroindate glass (in mol% 37InF2:20ZnF2:20SrF2:16BaF2:2GdF2: 2NaF:1GaF3:2ErF3) when the sample is irradiated with a CW laser emitting at 650 nm. An intensity dependence of the optical transmittance is detected. Saturation and sequential absorption of two photons are responsible for the decrease of 50% in the transmittance. The results are explained by simple models which are solved based on rate-equations for the populations of energy levels.
Resumo:
Ice used for human consumption or to refrigerate foods can be contaminated with pathogenic microorganisms and may become a vehicle for human infection. To evaluate the microbiological content of commercial ice and ice used to refrigerate fish and seafood, 60 ice samples collected at six different retail points in the city of Araraquara, SP, Brazil, were studied. The following parameters were determined: total plate counts (37° C and 4° C), most probable number (MPN) for total coliforms, fecal coliforms and Escherichia coli, presence of Salmonella spp., Shigella spp., Yersinia spp., E. coli, Vibrio cholerae and Aeromonas spp.. Results suggested poor hygienic conditions of ice production due to the presence of indicator micro-organisms. Fifty strains of E. coli of different serotypes, as well as one Y. enterocolitica biotype 1, serogroup 0:5, 27 and phage type Xz (Ye 1/05,27/Xz) and one Salmonella Enteritidis phage type 1 (PT1) were isolated. Aeromonas spp., Shigella spp. and V. cholerae were not detected. The presence of high numbers of coliforms, heterotrophic indicator micro-organisms and pathogenic strains suggested that commercial ice and ice used to refrigerate fish and seafood may rep resent a potential hazard to the consumer in our community. © 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Surface morphology changes induced by argon laser irradiation (514 nm) on disperse red 13 (DR13) films prepared by physical vapor deposition (PVD) were investigated. Atomic force microscopy was used to characterize the irradiated sample for different periods of irradiation. Needle-shape structures are observed which are attributed to the symmetry of DR13 molecules. The film becomes increasingly closely packed with the irradiation, with lower root mean square roughness for long exposure times. This is due to photoisomerization of DR13 molecules and probably heating of the sample, which can provide the required mobility for the molecular rearrangement. The rearrangement is such that voids in the film are filled in upon irradiating the sample, thus decreasing the film roughness and increasing the packing.
Resumo:
Tissue repair is an integration of dynamic interactive processes that involves soluble mediators, blood components, production of extra-cellular matrix and mesenchymal cells. Many studies involving the use of LLLT shows that the healing process is favored by such therapy. The aim of this work was to evaluate, through histological analysis, the tissue effects of cutaneous wounds submitted to different intensities and a same irradiation dose with lasers in λ670 or λ685nm. Eighteen animals were divided in two experimental groups according to wavelength used (λ670 or λ685nm). Each one of these groups was divided still in three subgroups of three animals each, related to the intensity of applied irradiation (2, 15 or 25mW). Twelve animals acted as untreated controls and were not irradiated. The irradiation was carried out during seven days. The animals were sacrificed eight days after surgery. The specimens were removed, kept in 4% formaldehyde for 24 hours, routinely prepared to wax, stained with H&E and analyzed under light microscopy. The histological characteristics observed, so much in the irradiated animals, as in the control, they are indicative of a substitution repair process, however, the LLLT modulatory positive effect was observed, in the healing process, mainly associate to the use of the shorter wavelength and low power. The results of the present study indicate that LLLT improves cutaneous wound repair and best results are achieved when higher potencies associated to short wavelengths or lower potencies associated to higher wavelengths are used.
Resumo:
Objective: The aim of this study was to evaluate the effectiveness of the clinical use of the gallium-aluminum-arsenium (GaAlAs) laser at the maximum and minimum energies recommended by the manufacturer for the treatment of dentine hypersensitivity. Background Data: Dentine hypersensitivity (DH) is a response to a stimulus that would not usually cause pain in a healthy tooth. It is characterized by sharp pain of short duration from the denuded dentin. Its etiology is unknown. The dentin only begins to show sensitivity when exposed to the buccal environment. This exposure can result after removal of the enamel and/or dental cement, or after root denudation. Different treatments are proposed for this disorder. Materials and Methods: In this study, 25 patients, with a total number of 106 cases of DH, were treated with GaAlAs low-level laser therapy (LLLT). 65% of the teeth were premolars; 14% were incisors and molars; 6.6% were canines. The teeth were irradiated with 3 and 5 J/cm 2 for up to six sessions, with an interval of 72 h between each application, and they were evaluated initially, after each application, and at 15 and 60 days follow-up post-treatment. Results: The treatment was effective in 86.53% and 88.88% of the irradiated teeth, respectively, with the minimum and maximum energy recommended by the manufacturer. There was a statistically significant difference between DH and after a follow-up of 60 days for both groups. The difference among the energy maximum and minimum was not significant. Conclusion: The GaAlAs low-level laser was effective in reducing initial DH. A significant difference was found between initial values of hypersensitivity and after 60 days follow-up post-treatment. No significant difference was found between minimum (3 J/cm 2) and maximum (5 J/cm 2) applied energy.
Resumo:
Purpose: The aim of this study was to evaluate the effectiveness of microwave irradiation sterilization on hard chairside reline resins. Materials and Methods: Specimens of three reline resins (Kooliner, Tokuso Rebase, and Ufi Gel Hard) were fabricated and subjected to ethylene oxide sterilization. The specimens were then individually inoculated (107 cfu/mL) with Tryptic Soy Broth media containing one of the tested microorganisms (C albicans, S aureus, B subtilis, and P aeruginosa). After 48 hours at 37°C, the samples were vortexed for 1 minute and allowed to stand for 9 minutes, followed by a short vortex to resuspend any organisms present. After inoculation, 40 specimens of each material were immersed in 200 mL of water and subjected to microwave irradiation at 650 W for 6 minutes. Forty non-irradiated specimens were used as positive controls. Replicate specimens (25 μL) of suspension were plated at dilutions of 10-3 to 10-6 on plates of selective media appropriate for each organism. All plates were incubated at 37°C for 48 hours. After incubation, colonies were counted, and the data were statistically analyzed by the Kruskal-Wallis test. Twelve specimens of each material were prepared for SEM. Results: All immersed specimens showed consistent sterilization of all the individual organisms after microwave irradiation. SEM examination indicated an alteration in cell morphology after microwave irradiation. Conclusion: Microwave sterilization for 6 minutes at 650 W proved to be effective for the sterilization of hard chairside reline resins.
Resumo:
The influence of He-Ne laser radiation on the formation of new blood vessels in the bone marrow compartment of a regenerating area of the mid-cortical diaphysis of the tibiae of young adult rats was studied. A small hole was surgically made with a dentistry burr in the tibia and the injured area received a daily laser therapy over 7 or 14 days transcutaneously starting 24 h from surgery. Incident energy density dosages of 31.5 and 94.5 Jcm-2 were applied during the period of the tibia wound healing investigated. Light microscopic examination of histological sections of the injured area and quantification of the newly-formed blood vessels were undertaken. Low-level energy treatment accelerated the deposition of bone matrix and histological characteristics compatible with an active recovery of the injured tissue. He-Ne laser therapy significantly increased the number of blood vessels after 7 days irradiation at an energy density of 94.5 Jcm-2, but significantly decreased the number of vessels in the 14-day irradiated tibiae, independent of the dosage. These effects were attributed to laser treatment, since no significant increase in blood vessel number was detected between 8 and 15 non-irradiated control tibiae. Molecular mechanisms involved in low-level laser therapy of angiogenesis in post-traumatic bone regeneration needs further investigation.