920 resultados para Invasive Candidiasis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oropharyngeal candidiasis is a common clinical problem encountered in patients with defects in innate or cell-mediated immunity. We have previously shown that recovery from chronic oropharyngeal candidiasis is dependent on CD4+ T-cell augmentation of neutrophil and macrophage candidacidal activity, and that the immune response is characterised by the production of cytokines such as IL-12 and IFN-gamma by cells in the local draining lymph nodes, and by the expression of TNF-alpha in the oral tissues. Objective: The purpose of this study was to elaborate on the role of these cytokines in recovery from oropharyngeal candidiasis, by using cytokine-specific gene-knockout mice. Methods: These mice are created by targeted gene mutation (tm1) of embryonic stem (ES) cells microinjected into host embryos. IL-4, IL-10, IL-12, IFN-gamma and TNF-alpha knockout mice, and appropriate controls, were infected orally with 108 viable C. albicans yeasts. The infection was quantified by swabbing the oral cavity and plating on Sabouraud's agar. Results: Tnftm1mice developed an acute severe infection characterized by an increased fungal load in the early stages of infection, but cleared the yeast within the same time frame as control mice (21 days). On the other hand, Il12btm1 mice developed a chronic oropharyngeal infection (120 days) similar to that seen in T-cell deficient (Foxn1nu/Foxn1nu) mutant mice. There was no significant difference between Il4tm1, Il10tm1, and Ifngtm1 mice and their respective controls. Conclusions: Tnftm1 mice may be rendered more susceptible through impaired recruitment of phagocytic cells, and/or impaired killing of C. albicans, whereas Il12btm1 mice may not be capable of activating naïve T-cells or inducing an appropriate cellular immune response. Supported by NHMRC and ADRF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a non-invasive phakometric method for determining corneal axis rotation relative to the visual axis (β) together with crystalline lens axis tilt (α) and decentration (d) relative to the corneal axis. This does not require corneal contact A-scan ultrasonography for the measurement of intraocular surface separations. Theoretical inherent errors of the method, evaluated by ray tracing through schematic eyes incorporating the full range of human ocular component variations, were found to be larger than the measurement errors (β < 0.67°, α < 0.72° and d < 0.08 mm) observed in nine human eyes with known ocular component dimensions. Intersubject variations (mean ± S.D.: β = 6.2 ± 3.4° temporal, α = 0.2 ± 1.8° temporal and d = 0.1 ± 0.1 mm temporal) and repeatability (1.96 × S.D. of difference between repeat readings: β ± 2.0°, α ± 1.8° and d ± 0.2 mm) were studied by measuring the left eyes of 45 subjects (aged 18-42 years, 29 females and 16 males, 15 Caucasians, 29 Indian Asians, one African, refractive error range -7.25 to +1.25 D mean spherical equivalent) on two occasions. © 2005 The College of Optometrists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose-To develop a non-invasive method for quantification of blood and pigment distributions across the posterior pole of the fundus from multispectral images using a computer-generated reflectance model of the fundus. Methods - A computer model was developed to simulate light interaction with the fundus at different wavelengths. The distribution of macular pigment (MP) and retinal haemoglobins in the fundus was obtained by comparing the model predictions with multispectral image data at each pixel. Fundus images were acquired from 16 healthy subjects from various ethnic backgrounds and parametric maps showing the distribution of MP and of retinal haemoglobins throughout the posterior pole were computed. Results - The relative distributions of MP and retinal haemoglobins in the subjects were successfully derived from multispectral images acquired at wavelengths 507, 525, 552, 585, 596, and 611?nm, providing certain conditions were met and eye movement between exposures was minimal. Recovery of other fundus pigments was not feasible and further development of the imaging technique and refinement of the software are necessary to understand the full potential of multispectral retinal image analysis. Conclusion - The distributions of MP and retinal haemoglobins obtained in this preliminary investigation are in good agreement with published data on normal subjects. The ongoing development of the imaging system should allow for absolute parameter values to be computed. A further study will investigate subjects with known pathologies to determine the effectiveness of the method as a screening and diagnostic tool.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The devising of a general engineering theory of multifunctional diagnostic systems for non-invasive medical spectrophotometry is an important and promising direction of modern biomedical engineering. We aim in this study to formalize in scientific engineering terms objectives for multifunctional laser non-invasive diagnostic system (MLNDS). The structure-functional model as well as a task-function of generalized MLNDS was formulated and developed. The key role of the system software for MLNDS general architecture at steps of ideological-technical designing has been proved. The basic principles of block-modules composition of MLNDS hardware are suggested as well. © 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In non-invasive ventilation, continuous monitoring of respiratory volumes is essential. Here, we present a method for the measurement of respiratory volumes by a single fiber-grating sensor of bending and provide the proof-of-principle by applying a calibration-test measurement procedure on a set of 18 healthy volunteers. Results establish a linear correlation between a change in lung volume and the corresponding change in a local thorax curvature. They also show good sensor accuracy in measurements of tidal and minute respiratory volumes for different types of breathing. The proposed technique does not rely on the air flow through an oronasal mask or the observation of chest movement by a clinician, which distinguishes it from the current clinical practice. © 2014 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An important field of application of lasers is biomedical optics. Here, they offer great utility for diagnosis, therapy and surgery. For the development of novel methods of laser-based biomedical diagnostics careful study of light propagation in biological tissues is necessary to enhance our understanding of the optical measurements undertaken, increase research and development capacity and the diagnostic reliability of optical technologies. Ultimately, fulfilling these requirements will increase uptake in clinical applications of laser based diagnostics and therapeutics. To address these challenges informative biomarkers relevant to the biological and physiological function or disease state of the organism must be selected. These indicators are the results of the analysis of tissues and cells, such as blood. For non-invasive diagnostics peripheral blood, cells and tissue can potentially provide comprehensive information on the condition of the human organism. A detailed study of the light scattering and absorption characteristics can quickly detect physiological and morphological changes in the cells due to thermal, chemical, antibiotic treatments, etc [1-5]. The selection of a laser source to study the structure of biological particles also benefits from the fact that gross pathological changes are not induced and diagnostics make effective use of the monochromatic directional coherence properties of laser radiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Muscle invasive urinary bladder cancer is one of the most lethal cancers and its detection at the time of transurethral resection remains limited and diagnostic methods are urgently needed. We have developed a muscle invasive transitional cell carcinoma (TCC) model of the bladder using porcine bladder scaffold and the human bladder cancer cell line 5637. The progression of implanted cancer cells to muscle invasion can be monitored by measuring changes in the spectrum of endogenous fluorophores such as reduced nicotinamide dinucleotide (NADH) and flavins. We believe this could act as a useful tool for the study of fluorescence dynamics of developing muscle invasive bladder cancer in patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-invasive ventilation performed through an oronasal mask is a standard in clinical and homecare mechanical ventilation. Besides all its advantages, inevitable leaks through the mask cause errors in the feedback information provided by the airflow sensor and, hence, patient-ventilator asynchrony with multiple negative consequences. Here we investigate a new way to provide a trigger to the ventilator. The method is based on the measurement of rib cage movement at the onset of inspiration and during breathing by fibre-optic sensors. In a series of simultaneous measurements by a long-period fibre grating sensor and pneumotachograph we provide the statistical evidence of the 200 ms lag of the pneumo with respect the fibre-optic signal. The lag is registered consistently across three independent delay metrics. Further, we discuss exceptions from this trend and identify the needed improvements to the proposed fibre-sensing scheme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a comprehensive ecological indicator for invasive exotic plants, a human-influenced component of the Everglades that could threaten the success of the restoration initiative. Following development of a conceptual ecological model for invasive exotic species, presented as a companion paper in this special issue, we developed criteria to evaluate existing invasive exotic monitoring programs for use in developing invasive exotic performance measures. We then used data from the selected monitoring programs to define specific performance measures, using species presence and abundance as the basis of the indicator for invasive exotic plants. We then developed a series of questions used to evaluate region and/or individual species status with respect to invasion. Finally, we used an expert panel who had answered the questions for invasive exotic plants in the Everglades Lake Okeechobee model to develop a stoplight restoration report card to communicate invasive exotic plant status. The report card system provides a way to effectively evaluate and present indicator data to managers, policy makers, and the public using a uniform format among indicators. Collectively, the model, monitoring assessment, performance measures, and report card enable us to evaluate how invasive plants are impacting the restoration program and how effectively that impact is being managed. Applied through time, our approach also allows us to follow the progress of management actions to control the spread and reduce the impacts of invasive species and can be easily applied and adapted to other large-scale ecosystem projects.