985 resultados para Incompressible fluid
Resumo:
The importance of the frying oil as a heat-transfer medium and as a source of flavor precursors for the formation of potato chip flavor was investigated. Potato slices were fried in palmolein or silicone fluid, and the volatile flavor compounds of the resulting chips were isolated onto Tenax and analyzed by gas chromatography-mass spectrometry. Although the heat-transfer coefficients of the oils did not differ significantly, their temperature profiles during frying were different, probably due to greater turbulence on placing potato slices in palmolein, leading to more efficient heat transfer. Levels of Strecker aldehydes and sulfides in chips fried in the two media were not significantly different, but levels of pyrazines were significantly higher in palmolein-fried chips. Amounts of 2,4-decadienal were also significantly higher in palmolein-fried chips, but there was no significant difference in hexanal levels between the samples.
Resumo:
Comparisons of 2D fluid simulations with experimental measurements of Ar/Cl-2 plasmas in a low-pressure inductively coupled reactor are reported. Simulations show that the wall recombination coefficient of Cl atom (gamma) is a crucial parameter of the model and that neutral densities are very sensitive to its variations. The best agreement between model and experiment is obtained for gamma = 0.02, which is much lower than the value predicted for stainless steel walls (gamma = 0.6). This is consistent with reactor wall contaminations classically observed in such discharges. The electron density, negative ion fraction and Cl atom density have been investigated under various conditions of chlorine and argon concentrations, gas pressure and applied rf input power. The plasma electronegativity decreases with rf power and increases with chlorine concentration. At high pressure, the power absorption and distribution of charged particles become more localized below the quartz window. Although the experimental trends are well reproduced by the simulations, the calculated charged particle densities are systematically overestimated by a factor of 3-5. The reasons for this discrepancy are discussed in the paper.
Resumo:
Synovial fluid is a potential source of novel biomarkers for many arthritic disorders involving joint inflammation, including juvenile idiopathic arthritis. We first compared the distinctive protein ‘fingerprints’ of local inflammation in synovial fluid with systemic profiles within matched plasma samples. The synovial fluid proteome at the time of joint inflammation was then evaluated across clinical subgroups to identify early disease associated proteins. We measured the synovial fluid and plasma proteomes using the two-dimensional fluorescence difference gel electrophoresis approach. Image analysis software was used to highlight the expression levels of joint and subgroup associated proteins across the study cohort (n = 32). A defined subset of 30 proteins had statistically significant differences (p < 0.05) between sample types such that synovial fluid could be differentiated from plasma. Furthermore distinctive synovial proteome expression patterns segregate patient subgroups. Protein expression patterns localized in the chronically inflamed joint therefore have the potential to identify patients more likely to suffer disease which will spread from a single joint to multiple joints. The proteins identified could act as criteria to prevent disease extension by more aggressive therapeutic intervention directed at an earlier stage than is currently possible.
Resumo:
This review aims to summarise our knowledge to date on the protein complement of the synovial fluid (S F). The tissues, structure and pathophysiology of the synovial joint are briefly described. The salient features of the S F proteome, how it is composed and the influence of arthritic disease are highlighted and discussed. The concentrations of proteins that have been detected and quantified in SF are drawn together from the literature on osteoarthritis, rheumatoid arthritis and juvenile idiopathic arthritis. The measurements are plotted to give a perspective on the dynamic range of protein levels within the SF. Approaches to proteomic analysis of SF to date are discussed along with their findings. From the recent literature reviewed within, it is becoming increasingly clear that analysis of the SF proteome as a whole, could deliver the most valuable differential diagnostic fingerprints of a number of arthritic disorders. Further development of proteomic platforms could characterise prognostic profiles to improve the cliniciads ability to resolve unremitting disease by existing and novel therapeutics.
Resumo:
Background: Open abdominal aortic aneurysm (AAA) repair is associated with a significant morbidity (primarily respiratory and cardiac complications) and an overall mortality rate of 4% to 10%. We tested the hypothesis that perioperative fluid restriction would reduce complications and improve outcome after elective open AAA repair.
Resumo:
BACKGROUND—Multiple sensory neuropeptides are present in human airways and may contribute to diseases such as asthma. This study quantified and characterised substance P (SP), neurokinin A (NKA), and calcitonin gene related peptide (CGRP) immunoreactivity in bronchoalveolar lavage fluid in asthmatic and normal subjects.
METHODS—Using specific radioimmunoassay (RIA), SP, NKA and CGRP were measured in bronchoalveolar lavage fluid from asthmatic subjects (n = 5), normal subjects (n = 5), atopic non-asthmatic subjects (n = 6), and asthmatic subjects four hours after allergen challenge (n = 12). Peptide immunoreactivity was characterised using high performance liquid chromatography (HPLC) and RIA.
RESULTS—No SP or CGRP immunoreactivity was detected in any of the fractions from samples after extraction, HPLC, and RIA. Non-specific binding resulted in spurious SP immunoreactivity being detected in bronchoalveolar lavage fluid when no extraction process was employed. NKA was detected in significant amounts in asthmatic (median 550, range 425-625 pg/ml) and normal subjects (median 725, range 350-1425 pg/ml). The level of NKA was significantly higher in the asthmatic subjects after allergen challenge (median 750, range 350-1250 pg/ml) than in unchallenged asthmatic subjects (median 600, range 425-600 pg/ml, p<0.01).
CONCLUSIONS—Extraction and characterisation of peptides from bronchoalveolar lavage fluid must be performed to ensure that the measured immunoreactivity represents target peptide. NKA is present in bronchoalveolar lavage fluid in high concentrations and is the predominant tachykinin. The concentrations of NKA are similar in normal subjects and subjects with mild asthma.
Resumo:
Cell counting of bronchoalveolar lavage (BAL) fluid is performed manually in routine practice. This has both methodological and inherent errors; however, the accuracy and suitability of automated counting devices have been questioned. In this study, a Coulter(R) Counter D Industrial model was calibrated and then used to measure the total cell count in unprocessed bronchoalveolar lavage fluid, and compared to a standard manual method.
Resumo:
Most single-reed woodwind instrument models rely on a quasistationary approximation to describe the relationship between the volume flow and. the pressure difference across the reed channel. Semiempirical models based on the quasistationary approximation are very useful in explaining the fundamental characteristics of this family of instruments such as self-sustained oscillations and threshold of blowing pressure. However, they fail at explaining more complex phenomena associated with the fluid-structure interaction during dynamic flow regimes, such as the transient and steady-state behavior of the system as a function. of the mouthpiece geometry. Previous studies have discussed the accuracy of the quasistationary approximation but the amount of literature on the subject is sparse, mainly due to the difficulties involved in the measurement of dynamic flows in channels with an oscillating reed. In this paper, a numerical technique based on the lattice Boltzmann method and a finite difference scheme is proposed in order to investigate the characteristics of fully coupled fluid-structure interaction in single-reed mouthpieces with different channel configurations. Results obtained for a stationary simulation with a static reed agree very well with those predicted by the literature based on the quasistationary approximation. However, simulations carried out for a dynamic regime with dn oscillating reed show that the phenomenon associated with flow detachment and reattachment diverges considerably frorn the theoretical assumptions. Furthermore, in the case of long reed channels, the results obtained for the vena contracta factor are in significant disagreement with those predicted by theory. For short channels, the assumption of constant vena contracta was found to be valid for only 40% of the duty cycle. (c) 2007 Acoustical Society of America.