981 resultados para IMAGE SERIES
Resumo:
Background:¦Choristomas are benign, congenital tumours composed of normal tissue in an¦abnormal location. Osseous choristomas represent the rarest form of epibulbar choristomas,¦with now 65 cases reported in the literature. We did a retrospective clinicopathological study¦of all patients with epibulbar osseous choristoma observed at our institution since 1982 and¦updated the last review of the literature.¦History and Signs:¦Three Caucasian male patients, aged between 3 months and 11 years,¦were identified. All osseous choristomas were located under the superotemporal bulbar¦conjunctiva of the right eye.¦Therapy and Outcome:¦All lesions were managed with surgical excision. Histopathology¦revealed the presence of lamellar bone in all cases, one of which was associated with a¦dermolipoma.¦Conclusions:¦We report a small rare case series of 3 epibulbar osseous choristomas and did a¦review of the literature. In one patient, the osteoma was associated with a dermolipoma,¦corresponding to the fourth reported complex choristoma of this type, in an otherwise normal¦eye, in the literature.
Resumo:
The goal of this work is to develop a method to objectively compare the performance of a digital and a screen-film mammography system in terms of image quality. The method takes into account the dynamic range of the image detector, the detection of high and low contrast structures, the visualisation of the images and the observer response. A test object, designed to represent a compressed breast, was constructed from various tissue equivalent materials ranging from purely adipose to purely glandular composition. Different areas within the test object permitted the evaluation of low and high contrast detection, spatial resolution and image noise. All the images (digital and conventional) were captured using a CCD camera to include the visualisation process in the image quality assessment. A mathematical model observer (non-prewhitening matched filter), that calculates the detectability of high and low contrast structures using spatial resolution, noise and contrast, was used to compare the two technologies. Our results show that for a given patient dose, the detection of high and low contrast structures is significantly better for the digital system than for the conventional screen-film system studied. The method of using a test object with a large tissue composition range combined with a camera to compare conventional and digital imaging modalities can be applied to other radiological imaging techniques. In particular it could be used to optimise the process of radiographic reading of soft copy images.
Resumo:
We present MBIS (Multivariate Bayesian Image Segmentation tool), a clustering tool based on the mixture of multivariate normal distributions model. MBIS supports multichannel bias field correction based on a B-spline model. A second methodological novelty is the inclusion of graph-cuts optimization for the stationary anisotropic hidden Markov random field model. Along with MBIS, we release an evaluation framework that contains three different experiments on multi-site data. We first validate the accuracy of segmentation and the estimated bias field for each channel. MBIS outperforms a widely used segmentation tool in a cross-comparison evaluation. The second experiment demonstrates the robustness of results on atlas-free segmentation of two image sets from scan-rescan protocols on 21 healthy subjects. Multivariate segmentation is more replicable than the monospectral counterpart on T1-weighted images. Finally, we provide a third experiment to illustrate how MBIS can be used in a large-scale study of tissue volume change with increasing age in 584 healthy subjects. This last result is meaningful as multivariate segmentation performs robustly without the need for prior knowledge.
Resumo:
Selostus: Tasoskannerin ja digitaalisen kuva-analyysimenetelmän kalibrointi juurten morfologian kvantifioimiseksi
Resumo:
Introduction: Diffuse large B-cell lymphomas (DLBCL) represent a heterogeneous disease with variable clinical outcome. Identifying phenotypic biomarkers of tumor cells on paraffin sections that predict different clinical outcome remain an important goal that may also help to better understand the biology of this lymphoma. Differentiating non-germinal centre B-cell-like (non-GCB) from Germinal Centre B-cell-like (GCB) DLBCL according to Hans algorithm has been considered as an important immunohistochemical biomarker with prognostic value among patients treated with R-CHOP although not reproducibly found by all groups. Gene expression studies have also shown that IgM expression might be used as a surrogate for the GCB and ABC subtypes with a strong preferential expression of IgM in ABC DLBCL subtype. ImmunoFISH index based on the differential expression of MUM-1, FOXP1 by immunohistochemistry and on the BCL6 rearrangement by FISH has been previously reported (C Copie-Bergman, J Clin Oncol. 2009;27:5573-9) as prognostic in an homogeneous series of DLBCL treated with R-CHOP. In addition, oncogenic MYC protein overexpression by immunohistochemistry may represent an easy tool to identify the consequences of MYC deregulation in DLBCL. Our aim was to analyse by immunohistochemistry the prognostic relevance of MYC, IgM, GCB/nonGCB subtype and ImmunoFISH index in a large series of de novo DLBCL treated with Rituximab (R)-chemotherapy (anthracyclin based) included in the 2003 program of the Groupe d'Etude des Lymphomes de l'Adulte (GELA) trials. Methods: The 2003 program included patients with de novo CD20+ DLBCL enrolled in 6 different LNH-03 GELA trials (LNH-03-1B, -B, -3B, 39B, -6B, 7B) stratifying patients according to age and age-adjusted IPI. Tumor samples were analyzed by immunohistochemistry using CD10, BCL6, MUM1, FOXP1 (according to Barrans threshold), MYC, IgM antibodies on tissue microarrays and by FISH using BCL6 split signal DNA probes. Considering evaluable Hans score, 670 patients were included in the study with 237 (35.4%) receiving intensive R-ACVBP regimen and 433 (64.6%) R-CHOP/R-mini-CHOP. Results: 304 (45.4%) DLBCL were classified as GCB and 366 (54.6%) as non-GCB according to Hans algorithm. 337/567 cases (59.4%) were positive for the ImmunoFISH index (i.e. two out of the three markers positive: MUM1 protein positive, FOXP1 protein Variable or Strong, BCL6 rearrangement). Immunofish index was preferentially positive in the non-GCB subtype (81.3%) compared to the GCB subtype (31.2%), (p<0.001). IgM was recorded as positive in tumor cells in 351/637 (52.4%) DLBCL cases with a preferential expression in non-GCB 195 (53.3%) vs GCB subtype 100(32.9%), p<0.001). MYC was positive in 170/577 (29.5%) cases with a 40% cut-off and in 44/577 (14.2%) cases with a cut-off of 70%. There was no preferential expression of MYC among GCB or non-GCB subtype (p>0.4) for both cut-offs. Progression-free Survival (PFS) was significantly worse among patients with high IPI score (p<0.0001), IgM positive tumor (p<0.0001), MYC positive tumor with a 40% threshold (p<0.001), ImmunoFISH positive index (p<0.002), non-GCB DLBCL subtype (p<0.0001). Overall Survival (OS) was also significantly worse among patients with high IPI score (p<0.0001), IgM positive tumor (p=0.02), MYC positive tumor with a 40% threshold (p<0.01), ImmunoFISH positive index (p=0.02), non-GCB DLBCL subtype (p<0.0001). All significant parameters were included in a multivariate analysis using Cox Model and in addition to IPI, only the GCB/non-GCB subtype according to Hans algorithm predicted significantly a worse PFS among non-GCB subgroup (HR 1.9 [1.3-2.8] p=0.002) as well as a worse OS (HR 2.0 [1.3-3.2], p=0.003). This strong prognostic value of non-GCB subtyping was confirmed considering only patients treated with R- CHOP for PFS (HR 2.1 [1.4-3.3], p=0.001) and for OS (HR 2.3 [1.3-3.8], p=0.002). Conclusion: Our study on a large series of patients included in trials confirmed the relevance of immunohistochemistry as a useful tool to identify significant prognostic biomarkers for clinical use. We show here that IgM and MYC might be useful prognostic biomarkers. In addition, we confirmed in this series the prognostic value of the ImmunoFISH index. Above all, we fully validated the strong and independent prognostic value of the Hans algorithm, daily used by the pathologists to subtype DLBCL.
Resumo:
OBJECTIVE: To evaluate the pertinence of prenatal diagnosis in cases of congenital uropathy. STUDY DESIGN: Retrospective evaluation over a period of 6.5 years. METHOD: 93 cases were involved in the comparison of prenatal ultrasonographic diagnosis with neonatal findings, autopsy results, and follow-up data. RESULTS: 33 fetuses had renal parenchymal lesions, 44 had excretory system lesions, and 6 had bladder and/or urethral lesions. Seventy-three pregnancies lead to live births. Eighteen terminations of pregnancy were performed on the parents' request for extremely severe malformations. Two intrauterine deaths were observed, and two infants died in the postnatal period. Prenatal diagnosis was obtained at an average of 27 weeks gestation. Diagnostic concordance was excellent in 82% and partial in 12% of cases with renal parenchymal lesions; the false-positive rate was 6%. For excretory system lesions, concordance was excellent in 87% and partial in 7.4% of cases, with a false-positive rate of 5.6%. Finally, concordance was excellent in 100% of cases of bladder and/or urethral lesions. The overall rate of total concordance was 86%. Partial concordance cases consisted of malformations different from those previously diagnosed, but prenatal diagnosis nevertheless lead to further investigations in the neonatal period and to proper management. The false-positive diagnoses (5.4%) never lead to termination of pregnancy. CONCLUSION: Prenatal diagnosis of congenital uropathy is effective. A third-trimester ultrasonographic examination is necessary to ensure proper neonatal management, considering that the majority of cases are diagnosed at this gestational age.
Resumo:
The metamorphism of the carbonate rocks of the SE Zanskar Tibetan zone has been studied by `'illite crystallinity'' and calcite-dolomite thermometry. The epizonal Zangla unit overlies the anchizonal Chumik unit. This discontinuous inverse zonation demonstrates a late to post-metamorphic thrust of the first unit over the second. The studied area underwent a complex tectonic history: - The tectonic units were stacked from the NE to the SW, generating recumbent folds, NE dipping thrusts and the regional metamorphism. The compressive movements were active under lower temperature conditions, resulting in late thrusts that disturbed the metamorphic zonation. The discontinuous inverse metamorphic zonation dates from this phase. - A NE vergent backfolding phase occurred at lower temperature conditions. It caused the uplift of more metamorphic levels. - A late extensional phase is revealed by the presence of NE dipping low angle normal faults, and a major high angle fault, the Sarchu fault. The low angle normal faults locally run along earlier thrusts (composite tectonic contacts). Their throw has been sufficient to reset a normal stratigraphic superposition (young layers overlying old ones), but insufficient to erase the inverse metamorphic relationship. However, the combined action of backfolding and normal faulting can locally lessen, or even cancel, the inverse metamorphic superposition. After deduction of the normal fault translation, the vertical component of the original thrust displacement through stratigraphy is 400 m, which is a value far too low to explain the temperature difference between the two units. The horizontal component of displacement is therefore far more important than the vertical one. The regional distribution of metamorphism within the Zangla unit points out to an anchizonal front and an epizonal inner part. This fact is in agreement with nappe tectonics.
Resumo:
In mammography, the image contrast and dose delivered to the patient are determined by the x-ray spectrum and the scatter to primary ratio S/P. Thus the quality of the mammographic procedure is highly dependent on the choice of anode and filter material and on the method used to reduce the amount of scattered radiation reaching the detector. Synchrotron radiation is a useful tool to study the effect of beam energy on the optimization of the mammographic process because it delivers a high flux of monochromatic photons. Moreover, because the beam is naturally flat collimated in one direction, a slot can be used instead of a grid for scatter reduction. We have measured the ratio S/P and the transmission factors for grids and slots for monoenergetic synchrotron radiation. In this way the effect of beam energy and scatter rejection method were separated, and their respective importance for image quality and dose analyzed. Our results show that conventional mammographic spectra are not far from optimum and that the use of a slot instead of a grid has an important effect on the optimization of the mammographic process. We propose a simple numerical model to quantify this effect.
Resumo:
During conventional x-ray coronary angiography, multiple projections of the coronary arteries are acquired to define coronary anatomy precisely. Due to time constraints, coronary magnetic resonance angiography (MRA) usually provides only one or two views of the major coronary vessels. A coronary MRA approach that allowed for reconstruction of arbitrary isotropic orientations might therefore be desirable. The purpose of the study was to develop a three-dimensional (3D) coronary MRA technique with isotropic image resolution in a relatively short scanning time that allows for reconstruction of arbitrary views of the coronary arteries without constraints given by anisotropic voxel size. Eight healthy adult subjects were examined using a real-time navigator-gated and corrected free-breathing interleaved echoplanar (TFE-EPI) 3D-MRA sequence. Two 3D datasets were acquired for the left and right coronary systems in each subject, one with anisotropic (1.0 x 1.5 x 3.0 mm, 10 slices) and one with "near" isotropic (1.0 x 1.5 x 1.0 mm, 30 slices) image resolution. All other imaging parameters were maintained. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and the right coronary artery (RCA) were visualized. Objective assessment of coronary vessel sharpness was similar (41% +/- 5% vs. 42% +/- 5%; P = NS) between in-plane and through-plane views with "isotropic" voxel size but differed (32% +/- 7% vs. 23% +/- 4%; P < 0.001) with nonisotropic voxel size. In reconstructed views oriented in the through-plane direction, the vessel border was 86% more defined (P < 0.01) for isotropic compared with anisotropic images. A smaller (30%; P < 0.001) improvement was seen for in-plane reconstructions. Vessel diameter measurements were view independent (2.81 +/- 0.45 mm vs. 2.66 +/- 0.52 mm; P = NS) for isotropic, but differed (2.71 +/- 0.51 mm vs. 3.30 +/- 0.38 mm; P < 0.001) between anisotropic views. Average scanning time was 2:31 +/- 0:57 minutes for anisotropic and 7:11 +/- 3:02 minutes for isotropic image resolution (P < 0.001). We present a new approach for "near" isotropic 3D coronary artery imaging, which allows for reconstruction of arbitrary views of the coronary arteries. The good delineation of the coronary arteries in all views suggests that isotropic 3D coronary MRA might be a preferred technique for the assessment of coronary disease, although at the expense of prolonged scan times. Comparative studies with conventional x-ray angiography are needed to investigate the clinical utility of the isotropic strategy.