991 resultados para IMAGE SEQUENCE
Resumo:
Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality at CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.
Resumo:
Despite the development of novel typing methods based on whole genome sequencing, most laboratories still rely on classical molecular methods for outbreak investigation or surveillance. Reference methods for Clostridium difficile include ribotyping and pulsed-field gel electrophoresis, which are band-comparing methods often difficult to establish and which require reference strain collections. Here, we present the double locus sequence typing (DLST) scheme as a tool to analyse C. difficile isolates. Using a collection of clinical C. difficile isolates recovered during a 1-year period, we evaluated the performance of DLST and compared the results to multilocus sequence typing (MLST), a sequence-based method that has been used to study the structure of bacterial populations and highlight major clones. DLST had a higher discriminatory power compared to MLST (Simpson's index of diversity of 0.979 versus 0.965) and successfully identified all isolates of the study (100 % typeability). Previous studies showed that the discriminatory power of ribotyping was comparable to that of MLST; thus, DLST might be more discriminatory than ribotyping. DLST is easy to establish and provides several advantages, including absence of DNA extraction [polymerase chain reaction (PCR) is performed on colonies], no specific instrumentation, low cost and unambiguous definition of types. Moreover, the implementation of a DLST typing scheme on an Internet database, such as that previously done for Staphylococcus aureus and Pseudomonas aeruginosa ( http://www.dlst.org ), will allow users to easily obtain the DLST type by submitting directly sequencing files and will avoid problems associated with multiple databases.
Resumo:
We present here the first genome sequence of the Aeromonas diversa type strain (CECT 4254T). This strain was isolated from the leg wound of a patient in New Orleans (Louisiana, USA) and was originally described as Enteric Group 501 and distinguished from A. schubertii by DNADNA hybridization and phenotypical characterization.
Resumo:
Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality of CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.
Resumo:
The tourism image is an element that conditions the competitiveness of tourism destinations by making them stand out in the minds of tourists. In this context, marketers of tourism destinations endeavour to create an induced image based on their identity and distinctive characteristics.A number of authors have also recognized the complexity of tourism destinations and the need for coordination and cooperation among all tourism agents, in order to supply a satisfactory tourist product and be competitive in the tourism market. Therefore, tourism agents at the destination need to develop and integrate strategic marketing plans.The aim of this paper is to determine how cities of similar cultures use their resources with the purpose of developing a distinctive induced tourism image to attract tourists and the extent of coordination and cooperation among the various tourism agents of a destination in the process of induced image creation.In order to accomplish these aims, a comparative analysis of the induced image of two cultural cities is presented, Girona (Spain) and Perpignan (France). The induced image is assessed through the content analysis of promotional brochures and the extent of cooperation with in-depth interviews of the main tourism agents of these destinations.Despite the similarities of both cities in terms of tourism resources, results show the use of different attributes to configure the induced image of each destination, as well as a different configuration of the network of tourism agents that participate in the process of induced image creation
Resumo:
Study design: A retrospective study of image guided cervical implant placement precision. Objective: To describe a simple and precise classification of cervical critical screw placement. Summary of Background Data: "Critical" screw placement is defined as implant insertion into a bone corridor which is surrounded circumferentially by neurovascular structures. While the use of image guidance has improved accuracy, there is currently no classification which provides sufficient precision to assess the navigation success of critical cervical screw placement. Methods: Based on postoperative clinical evaluation and CT imaging, the orthogonal view evaluation method (OVEM) is used to classify screw accuracy into grade I (no cortical breach), grade la (screw thread cortical breach), grade II (internal diameter cortical breach) and grade III (major cortical breach causing neural or vascular injury). Grades II and III are considered to be navigation failures, after accounting for bone corridor / screw mismatch (minimal diameter of targeted bone corridor being smaller than an outer screw diameter). Results: A total of 276 screws from 91 patients were classified into grade I (64.9%), grade la (18.1%), and grade II (17.0%). No grade III screw was observed. The overall rate of navigation failure was 13%. Multiple logistic regression indicated that navigational failure was significantly associated with the level of instrumentation and the navigation system used. Navigational failure was rare (1.6%) when the margin around the screw in the bone corridor was larger than 1.5 mm. Conclusions: OVEM evaluation appears to be a useful tool to assess the precision of critical screw placement in the cervical spine. The OVEM validity and reliability need to be addressed. Further correlation with clinical outcomes will be addressed in future studies.
Resumo:
This article analyzes the implications of worker overestimation of productivity for firms in which incentives take the form of tournaments. Each worker overestimates his productivity but is aware of the bias in his opponent's self-assessment. The manager of the firm, on the other hand, correctly assesses workers' productivities and self-beliefs when setting tournament prizes. The article shows that, under a variety of circumstances, firms can benefit from worker positive self-image. The article also shows that worker positive self-image can improve welfare in tournaments. In contrast, workers' utility declines due to their own misguided choices.
Resumo:
Objective:To evaluate the evolution of mammographic image quality in the state of Rio de Janeiro on the basis of parameters measured and analyzed during health surveillance inspections in the period from 2006 to 2011.Materials and Methods:Descriptive study analyzing parameters connected with imaging quality of 52 mammography apparatuses inspected at least twice with a one-year interval.Results:Amongst the 16 analyzed parameters, 7 presented more than 70% of conformity, namely: compression paddle pressure intensity (85.1%), films development (72.7%), film response (72.7%), low contrast fine detail (92.2%), tumor mass visualization (76.5%), absence of image artifacts (94.1%), mammography-specific developers availability (88.2%). On the other hand, relevant parameters were below 50% conformity, namely: monthly image quality control testing (28.8%) and high contrast details with respect to microcalcifications visualization (47.1%).Conclusion:The analysis revealed critical situations in terms of compliance with the health surveillance standards. Priority should be given to those mammography apparatuses that remained non-compliant at the second inspection performed within the one-year interval.
Resumo:
OBJECTIVE: The aim of this article was to apply psychometric theory to develop and validate a visual grading scale for assessing the visual perception of digital image quality anteroposterior (AP) pelvis. METHODS: Psychometric theory was used to guide scale development. Seven phantom and seven cadaver images of visually and objectively predetermined quality were used to help assess scale reliability and validity. 151 volunteers scored phantom images, and 184 volunteers scored cadaver images. Factor analysis and Cronbach's alpha were used to assess scale validity and reliability. RESULTS: A 24-item scale was produced. Aggregated mean volunteer scores for each image correlated with the rank order of the visually and objectively predetermined image qualities. Scale items had good interitem correlation (≥0.2) and high factor loadings (≥0.3). Cronbach's alpha (reliability) revealed that the scale has acceptable levels of internal reliability for both phantom and cadaver images (α = 0.8 and 0.9, respectively). Factor analysis suggested that the scale is multidimensional (assessing multiple quality themes). CONCLUSION: This study represents the first full development and validation of a visual image quality scale using psychometric theory. It is likely that this scale will have clinical, training and research applications. ADVANCES IN KNOWLEDGE: This article presents data to create and validate visual grading scales for radiographic examinations. The visual grading scale, for AP pelvis examinations, can act as a validated tool for future research, teaching and clinical evaluations of image quality.