984 resultados para Hydro power reliability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Pulmonary Embolism Severity Index (PESI) is a validated clinical prognostic model for patients with acute pulmonary embolism (PE). Our goal was to assess the PESI's inter-rater reliability in patients diagnosed with PE. We prospectively identified consecutive patients diagnosed with PE in the emergency department of a Swiss teaching hospital. For all patients, resident and attending physician raters independently collected the 11 PESI variables. The raters then calculated the PESI total point score and classified patients into one of five PESI risk classes (I-V) and as low (risk classes I/II) versus higher-risk (risk classes III-V). We examined the inter-rater reliability for each of the 11 PESI variables, the PESI total point score, assignment to each of the five PESI risk classes, and classification of patients as low versus higher-risk using kappa (κ) and intra-class correlation coefficients (ICC). Among 48 consecutive patients with an objective diagnosis of PE, reliability coefficients between resident and attending physician raters were > 0.60 for 10 of the 11 variables comprising the PESI. The inter-rater reliability for the PESI total point score (ICC: 0.89, 95% CI: 0.81-0.94), PESI risk class assignment (κ: 0.81, 95% CI: 0.66-0.94), and the classification of patients as low versus higher-risk (κ: 0.92, 95% CI: 0.72-0.98) was near perfect. Our results demonstrate the high reproducibility of the PESI, supporting the use of the PESI for risk stratification of patients with PE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Self-administered, general health risk screening questionnaires that are administered while patients wait in the doctor's office may be a reasonable and timesaving approach to address the requirements of preventive medicine in a typical 10-min medical visit. The psychometric characteristics of the Alcohol Use Disorders Identification Test (AUDIT) incorporated within a health questionnaire (H-AUDIT) have not been examined. METHODS: The reliability and validity of the self-administered AUDIT were compared between the H-AUDIT and the AUDIT used as a single scale (S-AUDIT) in 332 primary care patients. RESULTS: No major demographic or alcohol use characteristics were found between the 166 subjects who completed the H-AUDIT and the 166 individuals who completed the S-AUDIT. The test-retest reliability of the 166 subjects who completed the H-AUDIT [estimated by Spearman correlation coefficient at a 6-week interval (0.88), internal consistency (total correlation coefficients for all items ranged from 0.38 to 0.69; Cronbach alpha index 0.85), and the sensitivity and specificity of the H-AUDIT were used to identify at-risk drinkers' areas under receiver operating characteristic (0.77) and alcohol-dependent subjects' areas under receiver operating characteristic (0.89)] was similar to the same measurements obtained with the 166 individuals who completed the S-AUDIT. CONCLUSIONS: The AUDIT incorporated in a health risk screening questionnaire is a reliable and valid self-administered instrument to identify at-risk drinkers and alcohol-dependent individuals in primary care settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to assess the validity of two common methods used to assess energy intake. A 3-day weighed dietary record and a dietary history were collected and compared with the total daily energy expenditure (TEE) assessed by the heart rate method in a group of 12 obese and 12 nonobese prepubertal children (mean age 9.3 +/- 1.1 years vs 9.3 +/- 0.4 years). The TEE value was higher in obese than in nonobese children (9.89 +/- 1.08 vs 8.13 +/- 1.39 MJ/day; p < 0.01). Energy intake assessed by the dietary record was significantly lower than TEE in the obese children (7.06 +/- 0.98 MJ/day; p < 0.001) but comparable to TEE in the nonobese children (8.03 +/- 0.99 MJ/day; p = not significant). Energy intake assessed by diet history was lower than TEE in the obese children (8.37 +/- 1.35 MJ/day, p < 0.05) but close to TEE in the nonobese children (8.64 +/- 1.54 MJ/day, p = not significant). These results suggest that obese children underreport food intake and that the dietary record and the diet history are not valid means of assessing energy intake in obese prepubertal children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the factor structure and the reliability of the French versions of the Identity Style Inventory (ISI-3) and the Utrecht-Management of Identity Commitments Scale (U-MICS) in a sample of college students (N = 457, 18 to 25 years old). Confirmatory factor analyses confirmed the hypothesized three-factor solution of the ISI-3 identity styles (i.e. informational, normative, and diffuse-avoidant styles), the one-factor solution of the ISI-3 identity commitment, and the three-factor structure of the U-MICS (i.e. commitment, in-depth exploration, and reconsideration of commitment). Additionally, theoretically consistent and meaningful associations among the ISI-3, U-MICS, and Ego Identity Process Questionnaire (EIPQ) confirmed convergent validity. Overall, the results of the present study indicate that the French versions of the ISI-3 and UMICS are useful instruments for assessing identity styles and processes, and provide additional support to the cross-cultural validity of these tools.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Program for Schistosomiasis Control within the Unified Health System (PCE-SUS) was implemented by 1999 in the Rainforest Zone or "Zona da Mata" of Pernambuco (ZMP) aiming to carry out biennial stool surveys of whole populations through municipal health organs followed by treatment of the positives through the local units of the Family Health Program (PSF). Yearly reports from the Health Department of Pernambuco State (SES/PE) from 2002 to 2004 on the PCE-SUS surveys were assessed to evaluate whether the current estimates of prevalence in the municipalities of the ZMP are based on reliable samples so as to allow considerations on the real situation of schistosomiasis in that area. The surveys carried out in that period did not follow the major principles underlying sampling design, thus posing problems in both precision and validity of the estimates. Only 12 out of 43 municipalities had minimally reliable estimates: five with moderate prevalence (10-50%) and seven with low prevalence (< 10%). Surveys with appropriate sampling procedures aimed either at representative target groups (school-aged children) or communities are recommended for the ZMP and other endemic areas not only to provide reliable information on the current situation of schistosomiasis but also to plan adequate control strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stable carbon and oxygen isotope analyses were conducted on pedogenic needle fibre calcite (NFC) from seven sites in areas with roughly similar temperate climates in Western Europe, including the Swiss Jura Mountains, eastern and southern France, northern Wales, and north-eastern Spain. The δ(13)C values (-12.5 to-6.8 0/00 Vienna Pee Dee Belemnite (VPDB)) record the predominant C(3) vegetation cover at the sites. A good correlation was found between mean monthly climatic parameters (air temperature, number of frost days, humidity, and precipitation) and δ(18)O values (-7.8 to-3.40/00 VPDB) of all the NFC. Similar seasonal variations of δ(18)O values for monthly NFC samples from the Swiss sites and those of mean monthly δ(18)O values of local precipitation and meteorological data point out precipitation and preferential growth/or recrystallisation of the pedogenic needle calcite during dry seasons. These covariations indicate the potential of stable isotope compositions of preserved NFC in fossil soil horizons as a promising tool for palaeoenvironmental reconstructions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Anterior shoulder stabilization surgery with the arthroscopic Bankart procedure can have a high recurrence rate in certain patients. Identifying these patients to modify outcomes has become a focal point of research. PURPOSE: The Instability Shoulder Index Score (ISIS) was developed to predict the success of arthroscopic Bankart repair. Scores range from 0 to 10, with higher scores predicting a higher risk of recurrence after stabilization. The interobserver reliability of the score is not known. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: This is a prospective multicenter (North America and Europe) study of patients suffering from shoulder instability and waiting for stabilization surgery. Five pairs of independent evaluators were asked to score patient instability severity with the ISIS. Patients also completed functional scores (Western Ontario Shoulder Instability Index [WOSI], Disabilities of the Arm, Shoulder and Hand-short version [QuickDASH], and Walch-Duplay test). Data on age, sex, number of dislocations, and type of surgery were collected. The test-retest method and intraclass correlation coefficient (ICC: >0.75 = good, >0.85 = very good, and >0.9 = excellent) were used for analysis. RESULTS: A total of 114 patients with anterior shoulder instability were included, of whom 89 (78%) were men. The mean age was 28 years. The ISIS was very reliable, with an ICC of 0.933. The mean number of dislocations per patient was higher in patients who had an ISIS of ≥6 (25 vs 14; P = .05). Patients who underwent more complex arthroscopic procedures such as Hill-Sachs remplissage or open Latarjet had higher preoperative ISIS outcomes, with a mean score of 4.8 versus 3.4, respectively (P = .002). There was no correlation between the ISIS and the quality-of-life questionnaires, with Pearson correlations all >0.05 (WOSI = 0.39; QuickDASH = 0.97; Walch-Duplay = 0.08). CONCLUSION: Our results show that the ISIS is reliable when used in a multicenter study with anterior traumatic instability populations. There was no correlation between the ISIS and the quality-of-life questionnaires, but surgical decisions reflected its increased use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our purpose in this article is to define a network structure which is based on two egos instead of the egocentered (one ego) or the complete network (n egos). We describe the characteristics and properties for this kind of network which we call “nosduocentered network”, comparing it with complete and egocentered networks. The key point for this kind of network is that relations exist between the two main egos and all alters, but relations among others are not observed. After that, we use new social network measures adapted to the nosduocentered network, some of which are based on measures for complete networks such as degree, betweenness, closeness centrality or density, while some others are tailormade for nosduocentered networks. We specify three regression models to predict research performance of PhD students based on these social network measures for different networks such as advice, collaboration, emotional support and trust. Data used are from Slovenian PhD students and their s

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND This study assesses the validity and reliability of the Spanish version of DN4 questionnaire as a tool for differential diagnosis of pain syndromes associated to a neuropathic (NP) or somatic component (non-neuropathic pain, NNP). METHODS A study was conducted consisting of two phases: cultural adaptation into the Spanish language by means of conceptual equivalence, including forward and backward translations in duplicate and cognitive debriefing, and testing of psychometric properties in patients with NP (peripheral, central and mixed) and NNP. The analysis of psychometric properties included reliability (internal consistency, inter-rater agreement and test-retest reliability) and validity (ROC curve analysis, agreement with the reference diagnosis and determination of sensitivity, specificity, and positive and negative predictive values in different subsamples according to type of NP). RESULTS A sample of 164 subjects (99 women, 60.4%; age: 60.4 +/- 16.0 years), 94 (57.3%) with NP (36 with peripheral, 32 with central, and 26 with mixed pain) and 70 with NNP was enrolled. The questionnaire was reliable [Cronbach's alpha coefficient: 0.71, inter-rater agreement coefficient: 0.80 (0.71-0.89), and test-retest intra-class correlation coefficient: 0.95 (0.92-0.97)] and valid for a cut-off value > or = 4 points, which was the best value to discriminate between NP and NNP subjects. DISCUSSION This study, representing the first validation of the DN4 questionnaire into another language different than the original, not only supported its high discriminatory value for identification of neuropathic pain, but also provided supplemental psychometric validation (i.e. test-retest reliability, influence of educational level and pain intensity) and showed its validity in mixed pain syndromes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fault location has been studied deeply for transmission lines due to its importance in power systems. Nowadays the problem of fault location on distribution systems is receiving special attention mainly because of the power quality regulations. In this context, this paper presents an application software developed in Matlabtrade that automatically calculates the location of a fault in a distribution power system, starting from voltages and currents measured at the line terminal and the model of the distribution power system data. The application is based on a N-ary tree structure, which is suitable to be used in this application due to the highly branched and the non- homogeneity nature of the distribution systems, and has been developed for single-phase, two-phase, two-phase-to-ground, and three-phase faults. The implemented application is tested by using fault data in a real electrical distribution power system