927 resultados para Hip fracture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two manganese steels were investigated: Fe-19.7%Mn (VM339A) and Fe-19.7%Mn stabilized with 0.056%C, 0.19%Ti and 0.083%Al (VM339B). The toughness of VM339A was higher than VM339B, but VM339B had higher hardness. Tempering does not affect the toughness of the alloys. SEM images of the fracture surface for both the alloys revealed ductile fractures. A further alloy with a lower manganese content, Fe-8.46%Mn-0.24%Nb-0.038%C, and thus even lower cost than the conventional 3.5Ni cryogenic steel, was tested for its impact toughness after heat treatment at 600°C, giving promising results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mounting accuracy of satellite payload and
ADCS (attitude determination and control subsystem) seats
is one of the requirements to achieve the satellite mission
with satisfactory performance. Deviation of the position of
the mounting seat for Multi-Band-Earth-Imager (MBEI) is
caused by cracks in the plate of the basis unit and bracket
for attachment of MBEI. These cracks were detected during
inspection of the satellite strength mock-up after vibration
testing for air transportation phase. Most probable reason of
the cracking is fatigue damage as strength mock-up
structure was subjected to prolonged vibration loading
during various loading cases. Total vibration duration
during testing is about 56 hours. In order to study the
cracking reasons, finite element modeling of the structural
parts of the basis unit including MBEI bracket and
instrument MBEI is subjected to harmonic response to
simulate vibration loading for the case of air transportation.
Numerical results are compared with the experimental ones,
and mechanical design of the basis-plate unit is modified

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The formulation of a 3D composite element and its use in a mixed-mode fracture mechanics example is presented. This element, like a conventional 3D finite element, has three degrees of freedom per node although, like a plate element, the strains are defined in the local directions of the mid-plane surface. The stress-strain property matrix of this element was modified to decouple the stresses in the local mid-plane and the strains normal to this plane thus preventing the element from being too stiff in bending. A main advantage of this formulation is the ability to model a laminate with a single 3D element. The motivation behind this work was to improve the computational efficiency associated with the calculation of strain energy release rates in laminated structures. A comparison of mixed-mode results using different elements of an in-house finite element package are presented. Good agreement was achieved between the results obtained using the new element and coventional higher-order elements

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This special-topic volume reports on new progress made in the analysis and understanding of fracture and damage mechanics. The Finite Element Method is a well-established analytical tool for theoretical fracture analysis. The development of interface elements which combine aspects of both fracture and damage mechanics has permitted the prediction of both crack initiation and propagation. A number of the papers presented here deal with their use and further development.Substantial progress has also been made in the use of the Boundary Element Method for treating crack problems. The inherent mathematical complexity of this method has resulted in somewhat slower progress than that enjoyed by the Finite Element Method and is still the focus of much research. The volume also presents a number of contributions arising from this field. A topic which is closely related to the study of fracture is structural repair. Although repairs are usually effected after fracture occurs, the structural analyst must still ensure that the repair itself is not prone to cracking or other forms of damage. Two approaches to the study of damage in a repaired structure are described in this special volume. These three aspects, taken together, ensure that even the expert will learn something new from this book.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel approach for introducing aligned carbon nanotubes (CNTs) at the crack interface of pre-impregnated (prepreg) carbon fibre composite plies, creating a hierarchical (three-phase) composite structure. The aim of this approach is to improve the interlaminar fracture toughness. The developed method for transplanting the aligned CNTs from the silicon wafer onto the pre-preg material is described. Scanning electron microscopy (SEM) was used to analyse the effects of the transplantation method. Double Cantilever Beam (DCB) specimens were prepared, according to ASTM standard D5528- 01R07E03 [1] and aligned multi-walled carbon nanotubes (MWCNTs) were introduced at the crack-tip. Mode I fracture tests for pristine (control) specimens and CNT-enhanced specimens were conducted and an average increase in the critical strain energy release rate (GIc) of approximately 50 % was achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to examine the potential of incorporating bovine fibres as a means of reinforcing a typically brittle apatite calcium phosphate cement for vertebroplasty. Type I collagen derived from bovine Achilles tendon was ground cryogenically to produce an average fibre length of 0.96 ± 0.55 mm and manually mixed into the powder phase of an apatite-based cement at 1, 3 or 5 wt.%. Fibre addition of up to 5 wt.% had a significant effect (P = 0.001) on the fracture toughness, which was increased by 172%. Adding =1 wt.% bovine collagen fibres did not compromise the compressive properties significantly, however, a decrease of 39-53% was demonstrated at =3 wt.% fibre loading. Adding bovine collagen to the calcium phosphate cement reduced the initial and final setting times to satisfy the clinical requirements stated for vertebroplasty. The cement viscosity increased in a linear manner (R = 0.975) with increased loading of collagen fibres, such that the injectability was found to be reduced by 83% at 5 wt.% collagen loading. This study suggests for the first time the potential application of a collagen-reinforced calcium phosphate cement as a viable option in the treatment of vertebral fractures, however, issues surrounding efficacious cement delivery need to be addressed. © 2012 Acta Materialia Inc.