996 resultados para HETEROGENEOUS SURFACES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design, fabrication, and characterization of single-screen perturbed frequency-selective surfaces (FSS) at infrared frequencies for single and multiband applications are reported. Single-band FSS based on parallel strips have been perturbed by decreasing the length of every second strip within the array in order to achieve dual band-stop responses. The same principle has been extended to design FSS exhibiting tri- and quadreflection bands. In addition, strip FSSs have been perturbed by replacing every second strip for a metallic ring, resulting in dual-band filters with different polarization responses of the bands. These designs have been fabricated on large thin polyimide membranes using sacrificial silicon wafers. An oxide interlayer between the sacrificial silicon wafer and the polyimide membrane is employed to stop the silicon etching and is wet etched subsequently by a solution of ammonium fluoride and acetic acid that does not attack either the polyimide membrane or the aluminium FSS elements. Fourier transform infrared spectroscopy measurements are presented to validate the predicted responses of the fabricated prototypes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface plasmon resonance (SPR) based biosensor technology has been widely used in life science research for many applications. While the advantages of speed, ruggedness, versatility, sensitivity and reproducibility are often quoted, many researchers have experienced severe problem of non-specific binding (NSB) to chip surfaces when performing analysis of biological samples Such as bovine serum. Using the direct measurement of the bovine protein leptin, present in bovine serum samples as a model, a unique buffering system has been developed and optimised which was able to significantly reduce the non-specific interactions of bovine serum components with the carboxymethyl dextran chip (CM5) surface on a Biacore SPR The developed NSB buffering system comprised of HBS-EP buffer, containing 0.5 M NaCl, 0.005% CM-dextran pH 9.0. An average NSB reduction (n = 20) of 85.9% and 87.3% was found on an unmodified CM5 surface and a CM5 with bovine leptin immobilised on the chip surface, respectively. A reduction in NSB of up to 94% was observed on both surfaces. The concentration of the constitutive components and pH of the buffer were crucial in achieving this outcome. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND:
The genetic heterogeneity of many Mendelian disorders, such as retinitis pigmentosa which results from mutations in over 40 genes, is a major obstacle to obtaining a molecular diagnosis in clinical practice. Targeted high-throughput DNA sequencing offers a potential solution and was used to develop a molecular diagnostic screen for patients with retinitis pigmentosa.
METHODS:
A custom sequence capture array was designed to target the coding regions of all known retinitis pigmentosa genes and used to enrich these sequences from DNA samples of five patients. Enriched DNA was subjected to high-throughput sequencing singly or in pools, and sequence variants were identified by alignment of up to 10 million reads per sample to the normal reference sequence. Potential pathogenicity was assessed by functional predictions and frequency in controls.
RESULTS AND CONCLUSIONS:
Known homozygous PDE6B and compound heterozygous CRB1 mutations were detected in two patients. A novel homozygous missense mutation (c.2957A?T; p.N986I) in the cyclic nucleotide gated channel ß1 (CNGB1) gene predicted to have a deleterious effect and absent in 720 control chromosomes was detected in one case in which conventional genetic screening had failed to detect mutations. The detection of known and novel retinitis pigmentosa mutations in this study establishes high-throughput DNA sequencing with DNA pooling as an effective diagnostic tool for heterogeneous genetic diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiresonant high impedance surfaces (HIS) without grounding vias that perform as artificial magnetic conductors (AMC) in multiple frequency bands and furthermore exhibit electromagnetic band gaps (EBG) in the same bands are presented. This is achieved by introducing perturbed frequency selective surface (FSS) arrays printed on grounded dielectric substrates. Arrays of linear dipoles are employed as an example. Perturbations are introduced by means of reducing the length of every other array element. Starting from the characteristics of a perturbed free-standing FSS, the authors present the effect of the perturbation on the excited currents and on the reflection properties of a corresponding AMC. Conclusions about the performance limitations are derived. Subsequently, a parametric study on practical HIS is presented and an optimised design with dual-band AMC and EBG response is demonstrated. Method of moments-based software has been developed and utilised for the fast and accurate analysis of such arrays. Experimental results validate the performance of the optimised structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents a cascaded arrangement comprising a double-layer frequency selective surface circularly polarizing (CPFSS) and a second screen that can be switched between artificial magnetic conduction (AMC) or perfect electric conducting. (PEC) states. The CPFSS consists of two stacked aluminium sheets patterned with periodic split ring structures While the AMC is a PCB sheet patterned with metallic squares interconnected by links By either open or short circuiting these links it is shown that the cascade of screens can be made to twist, or not to twist, an incident 45 degrees linearly polirized signal through 90 degrees upon reflection from the assembly The system was designed and optimized using CST software and predictions were validated experimentally and measured monostatic reflection loss results (C) 2010 Wiley Periodicals, Inc Microwave Opt Technol Lett 52 577-580, 2010. Published online in Wiley InterScience (www.interscience.wiley.com) DOI 10.1002/mop.24979

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new design method that greatly enhances the reflectivity bandwidth and angular stability beyond what is possible with a simple Salisbury screen is described. The performance improvement is obtained from a frequency selective surface (FSS) which is sandwiched between the outermost 377 Ω/square resistive sheet and the ground plane. This is designed to generate additional reflection nulls at two predetermined frequencies by selecting the size of the two unequal length printed dipoles in each unit cell. A multiband Salisbury screen is realised by adjusting the reflection phase of the FSS to position one null above and the other below the inherent absorption band of the structure. Alternatively by incorporating resistive elements midway on the dipoles, it is shown that the three absorption bands can be merged to create a structure with a −10 dB reflectivity bandwidth which is 52% larger and relatively insensitive to incident angle compared to a classical Salisbury screen having the same thickness. CST Microwave Studio was used to optimise the reflectivity performance and simulate the radar backscatter from the structure. The numerical results are shown to be in close agreement with bistatic measurements for incident angles up to 40° over the frequency range 5.4−18 GHz.