899 resultados para Fit quantification


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Flexible video bronchoscopes, in particular the Olympus BF Type 3C160, are commonly used in pediatric respiratory medicine. There is no data on the magnification and distortion effects of these bronchoscopes yet important clinical decisions are made from the images. The aim of this study was to systematically describe the magnification and distortion of flexible bronchoscope images taken at various distances from the object. Methods: Using images of known objects and processing these by digital video and computer programs both magnification and distortion scales were derived. Results: Magnification changes as a linear function between 100 mm ( x 1) and 10 mm ( x 9.55) and then as an exponential function between 10 mm and 3 mm ( x 40) from the object. Magnification depends on the axis of orientation of the object to the optic axis or geometrical axis of the bronchoscope. Magnification also varies across the field of view with the central magnification being 39% greater than at the periphery of the field of view at 15 mm from the object. However, in the paediatric situation the diameter of the orifices is usually less than 10 mm and thus this limits the exposure to these peripheral limits of magnification reduction. Intraclass correlations for measurements and repeatability studies between instruments are very high, r = 0.96. Distortion occurs as both barrel and geometric types but both types are heterogeneous across the field of view. Distortion of geometric type ranges up to 30% at 3 mm from the object but may be as low as 5% depending on the position of the object in relation to the optic axis. Conclusion: We conclude that the optimal working distance range is between 40 and 10 mm from the object. However the clinician should be cognisant of both variations in magnification and distortion in clinical judgements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/aims: Chronic infections such as those caused by Chlamydia pneumoniae and periodontopathic bacteria such as Porphyromonas gingivalis have been associated with atherosclerosis, possibly due to cross-reactivity of the immune response to bacterial GroEL with human heat shock protein (hHSP) 60. Methods: We examined the cross-reactivity of anti-GroEL and anti-P. gingivalis antibodies with hHSP60 in atherosclerosis patients and quantified a panel of six pathogens in atheromas. Results: After absorption of plasma samples with hHSP60, there were variable reductions in the levels of anti-GroEL and anti-P. gingivalis antibodies, suggesting that these antibodies cross-reacted with hHSP60. All of the artery specimens were positive for P. gingivalis. Fusobacterium nucleatum, Tannerella forsythia, C. pneumoniae, Helicobacter pylori, and Haemophilus influenzae were found in 84%, 48%, 28%, 4%, and 4% of arteries, respectively. The prevalence of the three periodontopathic microorganisms, P. gingivalis, F. nucleatum and T. forsythia, was significantly higher than that of the remaining three microorganisms. Conclusions: These results support the hypothesis that in some patients, cross-reactivity of the immune response to bacterial HSPs including those of periodontal pathogens, with arterial endothelial cells expressing hHSP60 may be a possible mechanism for the association between atherosclerosis and periodontal infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid method has been developed for the quantification of the prototypic cyclotide kalata B I in water and plasma utilizing matrix-assisted laser desorption ionisation time-of-flight (MALDI-TOF) mass spectrometry. The unusual structure of the cyclotides means that they do not ionise as readily as linear peptides and as a result of their low ionisation efficiency, traditional LC/MS analyses were not able to reach the levels of detection required for the quantification of cyclotides in plasma for pharmacokinetic studies. MALDI-TOF-MS analysis showed linearity (R-2 > 0.99) in the concentration range 0.05-10 mu g/mL with a limit of detection of 0.05 mu g/mL (9 fmol) in plasma. This paper highlights the applicability of MALDI-TOF mass spectrometry for the rapid and sensitive quantification of peptides in biological samples without the need for extensive extraction procedures. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Geospatio-temporal conceptual models provide a mechanism to explicitly represent geospatial and temporal aspects of applications. Such models, which focus on both what and when/where, need to be more expressive than conventional conceptual models (e.g., the ER model), which primarily focus on what is important for a given application. In this study, we view conceptual schema comprehension of geospatio-temporal data semantics in terms of matching the external problem representation (that is, the conceptual schema) to the problem-solving task (that is, syntactic and semantic comprehension tasks), an argument based on the theory of cognitive fit. Our theory suggests that an external problem representation that matches the problem solver's internal task representation will enhance performance, for example, in comprehending such schemas. To assess performance on geospatio-temporal schema comprehension tasks, we conducted a laboratory experiment using two semantically identical conceptual schemas, one of which mapped closely to the internal task representation while the other did not. As expected, we found that the geospatio-temporal conceptual schema that corresponded to the internal representation of the task enhanced the accuracy of schema comprehension; comprehension time was equivalent for both. Cognitive fit between the internal representation of the task and conceptual schemas with geospatio-temporal annotations was, therefore, manifested in accuracy of schema comprehension and not in time for problem solution. Our findings suggest that the annotated schemas facilitate understanding of data semantics represented on the schema.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Lean bodyweight (LBW) has been recommended for scaling drug doses. However, the current methods for predicting LBW are inconsistent at extremes of size and could be misleading with respect to interpreting weight-based regimens. Objective: The objective of the present study was to develop a semi-mechanistic model to predict fat-free mass (FFM) from subject characteristics in a population that includes extremes of size. FFM is considered to closely approximate LBW. There are several reference methods for assessing FFM, whereas there are no reference standards for LBW. Patients and methods: A total of 373 patients (168 male, 205 female) were included in the study. These data arose from two populations. Population A (index dataset) contained anthropometric characteristics, FFM estimated by dual-energy x-ray absorptiometry (DXA - a reference method) and bioelectrical impedance analysis (BIA) data. Population B (test dataset) contained the same anthropometric measures and FFM data as population A, but excluded BIA data. The patients in population A had a wide range of age (18-82 years), bodyweight (40.7-216.5kg) and BMI values (17.1-69.9 kg/m(2)). Patients in population B had BMI values of 18.7-38.4 kg/m(2). A two-stage semi-mechanistic model to predict FFM was developed from the demographics from population A. For stage 1 a model was developed to predict impedance and for stage 2 a model that incorporated predicted impedance was used to predict FFM. These two models were combined to provide an overall model to predict FFM from patient characteristics. The developed model for FFM was externally evaluated by predicting into population B. Results: The semi-mechanistic model to predict impedance incorporated sex, height and bodyweight. The developed model provides a good predictor of impedance for both males and females (r(2) = 0.78, mean error [ME] = 2.30 x 10(-3), root mean square error [RMSE] = 51.56 [approximately 10% of mean]). The final model for FFM incorporated sex, height and bodyweight. The developed model for FFM provided good predictive performance for both males and females (r(2) = 0.93, ME = -0.77, RMSE = 3.33 [approximately 6% of mean]). In addition, the model accurately predicted the FFM of subjects in population B (r(2) = 0.85, ME -0.04, RMSE = 4.39 [approximately 7% of mean]). Conclusions: A semi-mechanistic model has been developed to predict FFM (and therefore LBW) from easily accessible patient characteristics. This model has been prospectively evaluated and shown to have good predictive performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of lifetime prevalence of depression in cross-sectional surveys is biased by recall problems. We estimated it indirectly for two countries using modelling, and quantified the underestimation in the empirical estimate for one. A microsimulation model was used to generate population-based epidemiological measures of depression. We fitted the model to 1-and 12-month prevalence data from the Netherlands Mental Health Survey and Incidence Study (NEMESIS) and the Australian Adult Mental Health and Wellbeing Survey. The lowest proportion of cases ever having an episode in their life is 30% of men and 40% of women, for both countries. This corresponds to a lifetime prevalence of 20 and 30%, respectively, in a cross-sectional setting (aged 15-65). The NEMESIS data were 38% lower than these estimates. We conclude that modelling enabled us to estimate lifetime prevalence of depression indirectly. This method is useful in the absence of direct measurement, but also showed that direct estimates are underestimated by recall bias and by the cross-sectional setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reliable, comparable information about the main causes of disease and injury in populations, and how these are changing, is a critical input for debates about priorities in the health sector. Traditional sources of information about the descriptive epidemiology of diseases, injuries and risk factors are generally incomplete, fragmented and of uncertain reliability and comparability. Lack of a standardized measurement framework to permit comparisons across diseases and injuries, as well as risk factors, and failure to systematically evaluate data quality have impeded comparative analyses of the true public health importance of various conditions and risk factors. As a consequence the impact of major conditions and hazards on population health has been poorly appreciated, often leading to a lack of public health investment. Global disease and risk factor quantification improved dramatically in the early 1990s with the completion of the first Global Burden of Disease Study. For the first time, the comparative importance of over 100 diseases and injuries, and ten major risk factors, for global and regional health status could be assessed using a common metric (Disability-Adjusted Life Years) which simultaneously accounted for both premature mortality and the prevalence, duration and severity of the non-fatal consequences of disease and injury. As a consequence, mental health conditions and injuries, for which non-fatal outcomes are of particular significance, were identified as being among the leading causes of disease/injury burden worldwide, with clear implications for policy, particularly prevention. A major achievement of the Study was the complete global descriptive epidemiology, including incidence, prevalence and mortality, by age, sex and Region, of over 100 diseases and injuries. National applications, further methodological research and an increase in data availability have led to improved national, regional and global estimates for 2000, but substantial uncertainty around the disease burden caused by major conditions, including, HIV, remains. The rapid implementation of cost-effective data collection systems in developing countries is a key priority if global public policy to promote health is to be more effectively informed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this in vitro study was to evaluate the fracture load and marginal accuracy of crowns made from a shrinkage-free ZrSiO4 ceramic cemented with glass-ionomer or composite cement after chewing simulation. Thirty-two human mandibular molars were randomly divided into two groups. All teeth were prepared for and restored with shrinkage-free ZrSiO4 ceramic crowns (Everest HPC (R), KaVo). The crowns of group A (N = 16) were luted to the teeth using KetacCem (R) and group B (N = 16) were adhesively cemented using Panavia (R) 21EX. Measurements of the marginal accuracy before and after cementation were made using replicas and an image analysis system. All specimens were exposed to 1.2 million cycles of thermo-mechanical fatigue in a chewing simulator. Surviving specimens were subsequently loaded until fracture in a static testing device. Fracture loads (N) were recorded. All specimens survived chewing simulation. The mean fracture loads (+/- s.d.) were Group A, 1622 N (+/- 433); group B, 1957 N (+/- 806). There was no significant difference between the two groups (P > 0.05). The marginal gap values before cementation were (mean +/- s.d.): Group A, 32.7 mu m (+/- 6.8); group B, 33.0 mu m (+/- 6.7).The mean marginal gap values after cementation were (+/- s.d.): Group A, 44.6 mu m (+/- 6.7); group B, 46.6 mu m (+/- 7.7). The marginal openings were significantly higher after cementation for both groups (P < 0.05). All test groups demonstrated fracture load and marginal accuracy values within the range of clinical acceptability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Passion represents a strong inclination toward an activity that is important, liked, and in which significant time is invested. Although a harmonious passion is well integrated in one’s identity and is emitted willingly, obsessive passion is not well integrated and is emitted out of internal pressure. This study tested for the presence of a Passion × Environment fit interaction with respect to psychological adjustment. Elite hockey players (N = 233) who tried out for a team in a highly competitive league participated in this short-term longitudinal study. As hypothesized, being selected by the highly competitive leagues led to higher psychological adjustment than not being selected by such leagues. Two months later, an interaction revealed that among athletes who were playing in highly competitive leagues, obsessively passionate athletes reported higher psychological adjustment than did harmonious athletes. Conversely, among athletes playing in less competitive leagues, harmonious athletes reported higher psychological adjustment than did obsessive athletes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We drew on Foucault's notion of 'practices of the self' to examine how young people take up, negotiate, and resist the imperatives of a public health discourse concerned with the relationships between health, fitness, and the body. We did this through a discussion of the ways young women and men talk about their own and others' bodies, in the context of a number of in-depth interviews conducted for the Life Activity Project, a study of the place and meaning of physical activity in young people's lives, funded by an Australian Research Council Grant. We found that the young women and men in the study engaged the health/fitness discourse very differently: for the young men, health conflated with fitness as an embodied capacity to do physical work; and for the young women, health was a much more difficult and complex project associated with managing and monitoring practices associated with eating and exercise to maintain an 'appropriate' body shape.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A direct quadrupole ICP-MS technique has been developed for the analysis of the rare earth elements and yttrium in natural waters. The method has been validated by comparison of the results obtained for the river water reference material SLRS-4 with literature values. The detection limit of the technique was investigated by analysis of serial dilutions of SLRS-4 and revealed that single elements can be quantified at single-digit fg/g concentrations. A coherent normalised rare earth pattern was retained at concentrations two orders of magnitude below natural concentrations for SLRS-4, demonstrating the excellent inter-element accuracy and precision of the method. The technique was applied to the analysis of a diluted mid-salinity estuarine sample, which also displayed a coherent normalised rare earth element pattern, yielding the expected distinctive marine characteristics. (c) 2006 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To rapidly quantify hepatitis B virus (HBV) DNA by real-time PCR using efficient TaqMan probe and extraction methods of virus DNA. Methods: Three standards were prepared by cloning PCR products which targeted S, C and X region of HBV genome into pGEM-T vector respectively. A pair of primers and matched TaqMan probe were selected by comparing the copy number and the Ct values of HBV serum samples derived from the three different standard curves using certain serum DNA. Then the efficiency of six HBV DNA extraction methods including guanidinium isothiocyanate, proteinase K, NaI, NaOH lysis, alkaline lysis and simple boiling was analyzed in sample A, B and C by real-time PCR. Meanwhile, 8 clinical HBV serum samples were quantified. Results: The copy number of the same HBV serum sample originated from the standard curve of S, C and X regions was 5.7 × 104/ mL, 6.3 × 102/mL and 1.6 × 103/mL respectively. The relative Ct value was 26.6, 31.8 and 29.5 respectively. Therefore, primers and matched probe from S region were chosen for further optimization of six extraction methods. The copy number of HBV serum samples A, B and C was 3.49 × 109/mL, 2.08 × 106/mL and 4.40 × 107/mL respectively, the relative Ct value was 19.9, 30 and 26.2 in the method of NaOH lysis, which was the efficientest among six methods. Simple boiling showed a slightly lower efficiency than NaOH lysis. Guanidinium isothiocyanate, proteinase K and NaI displayed that the copy number of HBV serum sample A, B and C was around 105/ mL, meanwhile the Ct value was about 30. Alkaline failed to quantify the copy number of three HBV serum samples, Standard deviation (SD) and coefficient variation (CV) were very low in all 8 clinical HBV serum samples, showing that quantification of HBV DNA in triplicate was reliable and accurate. Conclusion: Real-time PCR based on optimized primers and TaqMan probe from S region in combination with NaOH lysis is a simple, rapid and accurate method for quantification of HBV serum DNA. © 2006 The WJG Press. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The visual technique of fashion photography is examined which taught Australian women to look modern. Especially fashion photography intervenes ambivalently into the story of Australian modernism and modernity. During 1920s and 1930s within the fashion press there were synergies and differences between commercial fashion photography, celebrity and cinematic portraiture, and social set endorsement. However, modernism was widely acknowledged in Australia during the 1920s through women's spaces, their fashions and culture of department stores.