926 resultados para FEMORAL-HEAD


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE to compare the vascular healing process between the sirolimus-eluting NEVO and the everolimus-eluting Xience stent by optical coherence tomography (OCT) at 1-year follow-up. BACKGROUND Presence of durable polymer on a drug-eluting metallic stent may be the basis of an inflammatory reaction with abnormal healing response. The NEVO stent, having a bioresorbable polymer eluted by reservoir technology, may overcome this problem. METHODS All consecutive patients, who received NEVO or Xience stent implantation between September 2010 and October 2010 in our institution, were included. Vascular healing was assessed at 1-year as percentage of uncovered struts, neointimal thickness (NIT), in-stent/stent area obstruction and pattern of neointima. RESULTS A total 47 patients (2:1 randomization, n = 32 NEVO, n = 15 Xience) were included. Eighteen patients underwent angiographic follow-up (eight patients with nine lesions for NEVO vs. 10 patients with 11 lesions for Xience). The angiographic late loss was numerically higher but not statistically different in NEVO compared with Xience treated lesions (0.38 ± 0.47 mm vs. 0.18 ± 0.27 mm; P = 0.171). OCT analysis of 4,912 struts demonstrated similar rates of uncovered struts (0.5 vs. 0.7%, P = 0.462), higher mean NIT (177.76 ± 87.76 µm vs. 132.22 ± 30.91 µm; P = 0.170) and in stent/stent area obstruction (23.02 ± 14.74% vs. 14.17 ± 5.94%, P = 0.120) in the NEVO as compared with Xience. CONCLUSION The NEVO stent with a reservoir technology seems to exhibit more neointimal proliferation as compared to Xience stent. The findings of our study, which currently represent the unique data existing on this reservoir technology, would need to be confirmed in a large population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Only limited data exists in terms of the incidence of intracranial bleeding (ICB) in patients with mild traumatic brain injury (MTBI). METHODS We retrospectively identified 3088 patients (mean age 41 range (7-99) years) presenting with isolated MTBI and GCS 14-15 at our Emergency Department who had undergone cranial CT (CCT) between 2002 and 2011. Indication for CCT was according to the "Canadian CT head rules." Patients with ICB were either submitted for neurosurgical treatment or kept under surveillance for at least 24 hours. Pearson's correlation coefficient was used to correlate the incidence of ICB with age, gender, or intake of coumarins, platelet aggregation inhibitors, or heparins. RESULTS 149 patients (4.8%) had ICB on CCT. No patient with ICB died or deteriorated neurologically. The incidence of ICB increased with age and intake of anticoagulants without clinically relevant correlation (R = 0.11; P < 0.001; R = -0.06; P < 0.001). CONCLUSION Our data show an incidence of 4.8% for ICB after MTBI. However, neurological deterioration after MTBI seems to be rare, and the need for neurosurgical intervention is only required in selected cases. The general need for CCT in patients after MTBI is therefore questionable, and clinical surveillance may be sufficient when CCT is not available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. METHODS Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). RESULTS In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. CONCLUSIONS Early results for PF-LCP osteosynthesis show major complications in 7 of 19 patients requiring reosteosynthesis or prosthesis implantation due to secondary loss of reduction or hardware removal. Further studies are required to evaluate the limitations of this device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IMPORTANCE This study addresses the value of patients' reported symptoms as markers of tumor recurrence after definitive therapy for head and neck squamous cell carcinoma. OBJECTIVE To evaluate the correlation between patients' symptoms and objective findings in the diagnosis of local and/or regional recurrences of head and neck squamous cell carcinomas in the first 2 years of follow-up. DESIGN Retrospective single-institution study of a prospectively collected database. SETTING Regional hospital. PARTICIPANTS We reviewed the clinical records of patients treated for oral cavity, oropharyngeal, laryngeal, and hypopharyngeal carcinomas between January 1, 2008, and December 31, 2009, with a minimum follow-up of 2 years. MAIN OUTCOMES AND MEASURES Correlation between symptoms and oncologic status (recurrence vs remission) in the posttreatment period. RESULTS Of the 101 patients included, 30 had recurrences. Pain, odynophagia, and dysphonia were independently correlated with recurrence (odds ratios, 16.07, 11.20, and 5.90, respectively; P < .001). New-onset symptoms had the best correlation with recurrences. Correlation was better between 6 to 12 and 18 to 21 months after therapy and in patients initially treated unimodally (P < .05). Primary stage and tumor site had no effect. CONCLUSIONS AND RELEVANCE The correlation between symptoms and oncologic status is low during substantial periods within the first 2 years of follow-up. New-onset symptoms, especially pain, odynophagia, or dysphonia, better correlate with tumor recurrence, especially in patients treated unimodally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS AND BACKGROUND Tumor progression due to seeding of tumor cells after definitive treatment for squamous cell carcinomas of the head and neck is an uncommon condition that can considerably worsen the outcome of patients with head and neck cancer. METHODS AND STUDY DESIGN We report two cases of recurrence due to neoplastic seeding from oropharyngeal and oral cancer, respectively. We performed a literature review with MEDLINE as the main search engine. RESULTS Seeding was found to occur most often in tracheotomy scars and gastrostomy sites. The oral cavity, hypopharynx and oropharynx were the primary sites in most cases, and advanced tumor stage seemed to be a risk factor for seeding. Treatment options include salvage surgery, which requires thorough resections, radiotherapy when possible, and palliative management. The prognosis of such events is poor. CONCLUSION Although neoplastic seeding is a well-known phenomenon in cancer surgery, many questions remain unanswered, especially regarding preventive measures and management strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To assess the clinical profile and prognostic factors in patients with adenosquamous carcinoma (ASC) of the head and neck treated by surgery and/or radiation therapy with or without chemotherapy. METHODS Data from 20 patients with stage I-II (n = 4), III (n = 5), or IVA (n = 11) head and neck ASC, treated between 1989 and 2010 were collected in a retrospective multicenter Rare Cancer Network study. Surgery was performed in 16 patients. Seventeen patients received combined modality treatment. RESULTS After a median follow-up of 15.5 months, 12 patients recurred. The 3-year and median overall survival, disease-free survival (DFS), and loco-regional control were 52% and 39 months, 32% and 12 months, and 47% and 33 months respectively. In multivariate analysis, DFS was negatively influenced by the presence of extracapsular extension and advanced stage. CONCLUSION Overall prognosis of locoregionally advanced ASC remains poor. However, early stage ASC patients managed with combined modality treatment may have prolonged DFS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the Burgdorf Museum of Ethnology, a mummy rests in a coffin. According to the inventory book, it was purchased from the Cairo Egyptian museum in 1926. The coffin was now examined by Egyptologists and the mummy was radiocarbon dated and examined by Anthropologists. The aim of the study was to compare the results and to check whether mummy and coffin actually belong together. The skull was examined morphological-anthropologically and by CT as a “blank sample”. Coffin and skull imply that the individual was female. The coffin dates to the Ptolemaic period. Only skull bones are preserved, the ethmoid is damaged. CT images Show resinous substances, bone fragments and brain remnants inside the skull. The ethmoid bone was probably foraminated during the mummification process and thus ended up inside the skull. The individual was mummified between the New Kingdom and the Ptolemaic period. Due to its style, it is most probable that the coffin comes from the Gamhud necropolis. The Burgdorf museum of ethnology inventory book chronicles were largely falsified by the examinations. There is a time gap between coffin and the mummy, there are two possible interpretations: the body was mummified with older linen, or the mummy and the coffin do not belong together. The authors strongly advise further investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the ability of dual energy X-rays absorptiometry (DXA) areal bone mineral density (aBMD) measured in different regions of the proximal part of the human femur for predicting the mechanical properties of matched proximal femora tested in two different loading configurations. 36 pairs of fresh frozen femora were DXA scanned and tested until failure in two loading configurations: a fall on the side or a one-legged standing. The ability of the DXA output from four different regions of the proximal femur in predicting the femoral mechanical properties was measured and compared for the two loading scenarios. The femoral neck DXA BMD was best correlated to the femoral ultimate force for both configurations and predicted significantly better femoral failure load (R2=0.80 vs. R2=0.66, P<0.05) when simulating a side than when simulating a standing configuration. Conversely, the work to failure was predicted similarly for both loading configurations (R2=0.54 vs. R2=0.53, P>0.05). Therefore, neck BMD should be considered as one of the key factors for discriminating femoral fracture risk in vivo. Moreover, the better predictive ability of neck BMD for femoral strength if tested in a fall compared to a one-legged stance configuration suggests that DXA's clinical relevance may not be as high for spontaneous femoral fractures than for fractures associated to a fall.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One Arabian and 5 Hungarian half-bred horses were used to study the macroscopic and microscopic survival of autologous osteochondral grafts in the weight-bearing surface of the medial femoral condyle (MFC). Grafts were harvested from the cranial surface of the medial femoral trochlea (MFT) under arthroscopic control. Three of them were transplanted into the weight-bearing surface of the contralateral MFC using an arthrotomy approach. Three months later this transplantation procedure was repeated on the opposite stifle joints in the same animals, but at that time transplantation was performed arthroscopically. Follow-up arthroscopy was carried out 12 months after the first operations, and biopsies were taken from both the recipient and the donor sites for histological examination. During follow-up arthroscopy, the transplanted areas looked congruent and smooth. Microscopically, the characteristics of hyaline cartilage were present in 5 out of the 10 biopsies examined; however, in the other half of biopsies glycosaminoglycan (GAG) loss and change in the architecture of the transplanted cartilage was observed. In a 16-year-old horse, all grafts broke during harvesting, and thus transplantation was not performed. No radiological signs of osteoarthritic changes were detected 9 to 12 months after the operations in the donor and recipient joints. Clinically, no lameness or effusion was present three months after the transplantations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Discrepancies in finite-element model predictions of bone strength may be attributed to the simplified modeling of bone as an isotropic structure due to the resolution limitations of clinical-level Computed Tomography (CT) data. The aim of this study is to calculate the preferential orientations of bone (the principal directions) and the extent to which bone is deposited more in one direction compared to another (degree of anisotropy). Using 100 femoral trabecular samples, the principal directions and degree of anisotropy were calculated with a Gradient Structure Tensor (GST) and a Sobel Structure Tensor (SST) using clinical-level CT. The results were compared against those calculated with the gold standard Mean-Intercept-Length (MIL) fabric tensor using micro-CT. There was no significant difference between the GST and SST in the calculation of the main principal direction (median error=28°), and the error was inversely correlated to the degree of transverse isotropy (r=−0.34, p<0.01). The degree of anisotropy measured using the structure tensors was weakly correlated with the MIL-based measurements (r=0.2, p<0.001). Combining the principal directions with the degree of anisotropy resulted in a significant increase in the correlation of the tensor distributions (r=0.79, p<0.001). Both structure tensors were robust against simulated noise, kernel sizes, and bone volume fraction. We recommend the use of the GST because of its computational efficiency and ease of implementation. This methodology has the promise to predict the structural anisotropy of bone in areas with a high degree of anisotropy, and may improve the in vivo characterization of bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sheep is a popular animal model for human biomechanical research involving invasive surgery on the hind limb. These painful procedures can only be ethically justified with the application of adequate analgesia protocols. Regional anaesthesia as an adjunct to general anaesthesia may markedly improve well-being of these experimental animals during the postoperative period due to a higher analgesic efficacy when compared with systemic drugs, and may therefore reduce stress and consequently the severity of such studies. As a first step 14 sheep cadavers were used to establish a new technique for the peripheral blockade of the sciatic and the femoral nerves under sonographic guidance and to evaluate the success rate by determination of the colorization of both nerves after an injection of 0.5 mL of a 0.1% methylene blue solution. First, both nerves were visualized sonographically. Then, methylene blue solution was injected and subsequently the length of colorization was measured by gross anatomical dissection of the target nerves. Twenty-four sciatic nerves were identified sonographically in 12 out of 13 cadavers. In one animal, the nerve could not be ascertained unequivocally and, consequently, nerve colorization failed. Twenty femoral nerves were located by ultrasound in 10 out of 13 cadavers. In three cadavers, signs of autolysis impeded the scan. This study provides a detailed anatomical description of the localization of the sciatic and the femoral nerves and presents an effective and safe yet simple and rapid technique for performing peripheral nerve blocks with a high success rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This prospective nonrandomized study compared the safety and efficacy of a novel arterial closure device (ACD) in common femoral artery procedures to that of the FDA submitted historical manual pressure control group, who underwent either a diagnostic angiogram (DA) or a percutaneous coronary intervention (PCI) procedure. Methods and Results A total of 55 patients were enrolled in this study of the novel ACD. Of the 55 patients, 39 were enrolled in the DA group and 16 were enrolled in the PCI group. Six patients were excluded. A device was deployed in 49 patients. Time to hemostasis (TTH), time to ambulation (TTA), device function, and device-related vascular complications were measured. In the device group, the TTH for the combined DA and PCI patients was 32 seconds (0.54 ± 0.93 minutes), significantly lower when compared with 16.0 ± 12.2 minutes (P < 0.0001) for the control group. Overall major vascular complication rate did not differ significantly, device group (1/49) and the historical control group (1/217). TTA in the combined PCI and DA device group was 226.4 ± 231.9 at the German site (site ambulation policy). In the Irish site, the average TTA in the PCI group was 187 minutes (n = 8) and 85 minutes (n = 14) in the DA group. Conclusion The Celt ACD® device is safe, effective, and significantly decreases the TTH compared to manual pressure and has a low vascular complications rate. The device may be effective in early ambulation and discharge of patients postcoronary intervention procedures.