932 resultados para Explosive actuated devices
Resumo:
A solvent-vapour thermoplastic bonding process is reported which provides high strength bonding of PMMA over a large area for multi-channel and multi-layer microfluidic devices with shallow high resolution channel features. The bond process utilises a low temperature vacuum thermal fusion step with prior exposure of the substrate to chloroform (CHCl3) vapour to reduce bond temperature to below the PMMA glass transition temperature. Peak tensile and shear bond strengths greater than 3 MPa were achieved for a typical channel depth reduction of 25 µm. The device-equivalent bond performance was evaluated for multiple layers and high resolution channel features using double-side and single-side exposure of the bonding pieces. A single-sided exposure process was achieved which is suited to multi-layer bonding with channel alignment at the expense of greater depth loss and a reduction in peak bond strength. However, leak and burst tests demonstrate bond integrity up to at least 10 bar channel pressure over the full substrate area of 100 mm x 100 mm. The inclusion of metal tracks within the bond resulted in no loss of performance. The vertical wall integrity between channels was found to be compromised by solvent permeation for wall thicknesses of 100 µm which has implications for high resolution serpentine structures. Bond strength is reduced considerably for multi-layer patterned substrates where features on each layer are not aligned, despite the presence of an intermediate blank substrate. Overall a high performance bond process has been developed that has the potential to meet the stringent specifications for lab-on-chip deployment in harsh environmental conditions for applications such as deep ocean profiling.
Resumo:
Measurements of explosive nucleosynthesis yields in core-collapse supernovae provide tests for explosion models. We investigate constraints on explosive conditions derivable from measured amounts of nickel and iron after radioactive decays using nucleosynthesis networks with parameterized thermodynamic trajectories. The Ni/Fe ratio is for most regimes dominated by the production ratio of Ni-58/(Fe-54 + Ni-56), which tends to grow with higher neutron excess and with higher entropy. For SN 2012ec, a supernova (SN) that produced a Ni/Fe ratio of 3.4 +/- 1.2 times solar, we find that burning of a fuel with neutron excess eta approximate to 6 x 10(-3) is required. Unless the progenitor metallicity is over five times solar, the only layer in the progenitor with such a neutron excess is the silicon shell. SNe producing large amounts of stable nickel thus suggest that this deep-lying layer can be, at least partially, ejected in the explosion. We find that common spherically symmetric models of M-ZAMS less than or similar to 13 M-circle dot stars exploding with a delay time of less than one second (M-cut < 1.5 M-circle dot) are able to achieve such silicon-shell ejection. SNe that produce solar or subsolar Ni/Fe ratios, such as SN 1987A, must instead have burnt and ejected only oxygen-shell material, which allows a lower limit to the mass cut to be set. Finally, we find that the extreme Ni/Fe value of 60-75 times solar derived for the Crab cannot be reproduced by any realistic entropy burning outside the iron core, and neutrino-neutronization obtained in electron capture models remains the only viable explanation.
Resumo:
The existence of loose particles left inside the sealed electronic devices is one of the main factors affecting the reliability of the whole system. It is important to identify the particle material for analyzing their source. The conventional material identification algorithms mainly rely on time, frequency and wavelet domain features. However, these features are usually overlapped and redundant, resulting in unsatisfactory material identification accuracy. The main objective of this paper is to improve the accuracy of material identification. First, the principal component analysis (PCA) is employed to reselect the nine features extracted from time and frequency domains, leading to six less correlated principal components. And then the reselected principal components are used for material identification using a support vector machine (SVM). Finally, the experimental results show that this new method can effectively distinguish the type of materials including wire, aluminum and tin particles.
Resumo:
This study proposes an approach to optimally allocate multiple types of flexible AC transmission system (FACTS) devices in market-based power systems with wind generation. The main objective is to maximise profit by minimising device investment cost, and the system's operating cost considering both normal conditions and possible contingencies. The proposed method accurately evaluates the long-term costs and benefits gained by FACTS devices (FDs) installation to solve a large-scale optimisation problem. The objective implies maximising social welfare as well as minimising compensations paid for generation re-scheduling and load shedding. Many technical operation constraints and uncertainties are included in problem formulation. The overall problem is solved using both particle swarm optimisations for attaining optimal FDs allocation as main problem and optimal power flow as sub-optimisation problem. The effectiveness of the proposed approach is demonstrated on modified IEEE 14-bus test system and IEEE 118-bus test system.
Resumo:
Temperament tests are widely accepted as instruments for profiling behavioral variability in dogs, and they are applied in numerous areas of investigation (e.g. suitability for adoption or for breeding). During testing, to elicit a dog's reaction toward novel stimuli and predict its behavior in everyday life, model devices such as a child-like doll, or a fake dog, are often employed. However, the reliability of these devices to accurately stimulate dogs' reactions to children or dogs, is unknown and perhaps overestimated. This may be a particular concern in the case of aggressive behavior toward humans, a significant public health issue. The aim of this study was to: (1) evaluate the correlation between dogs' reactions to these devices, and owners' reports of their dog's aggression history (using the C-BARQ ??); (2) compare reactions toward the devices of dogs with and without histories of aggression. Subjects were selected among those visiting for behavioral consultation at the Veterinary Hospital of the University of Pennsylvania, and previously categorized as aggressive toward unfamiliar children, conspecifics, or as non-aggressive dogs (control). The test consisted of different components: an unfamiliar female tester approaching the dog; the presentation of a child-like doll, an ambiguous object, and a fake plastic dog. All tests were videotaped and durations of behaviors were later analyzed on the basis of a specified ethogram. Dogs' reactions were compared to C-BARQ scores, and interesting correlations emerged for 'dog-directed aggression/fear' (R = 0.48, P = 0.004), and 'stranger-directed aggression' (R = 0.58, P <0.001) factors. Dogs differed in their reactions toward the devices: the child-like doll and the fake dog elicited more social behaviors than the ambiguous object used as a control stimulus. Issues concerning the reliability of these tools to assess canine temperament are discussed. ?? 2012 Elsevier B.V. All rights reserved.
Resumo:
Wearable devices performing advanced bio-signal analysis algorithms are aimed to foster a revolution in healthcare provision of chronic cardiac diseases. In this context, energy efficiency is of paramount importance, as long-term monitoring must be ensured while relying on a tiny power source. Operating at a scaled supply voltage, just above the threshold voltage, effectively helps in saving substantial energy, but it makes circuits, and especially memories, more prone to errors, threatening the correct execution of algorithms. The use of error detection and correction codes may help to protect the entire memory content, however it incurs in large area and energy overheads which may not be compatible with the tight energy budgets of wearable systems. To cope with this challenge, in this paper we propose to limit the overhead of traditional schemes by selectively detecting and correcting errors only in data highly impacting the end-to-end quality of service of ultra-low power wearable electrocardiogram (ECG) devices. This partition adopts the protection of either significant words or significant bits of each data element, according to the application characteristics (statistical properties of the data in the application buffers), and its impact in determining the output. The proposed heterogeneous error protection scheme in real ECG signals allows substantial energy savings (11% in wearable devices) compared to state-of-the-art approaches, like ECC, in which the whole memory is protected against errors. At the same time, it also results in negligible output quality degradation in the evaluated power spectrum analysis application of ECG signals.
Resumo:
The idea of proxying network connectivity has been proposed as an efficient mechanism to maintain network presence on behalf of idle devices, so that they can “sleep”. The concept has been around for many years; alternative architectural solutions have been proposed to implement it, which lead to different considerations about capability, effectiveness and energy efficiency. However, there is neither a clear understanding of the potential for energy saving nor a detailed performance comparison among the different proxy architectures. In this paper, we estimate the potential energy saving achievable by different architectural solutions for proxying network connectivity. Our work considers the trade-off between the saving achievable by putting idle devices to sleep and the additional power consumption to run the proxy. Our analysis encompasses a broad range of alternatives, taking into consideration both implementations already available in the market and prototypes built for research purposes. We remark that the main value of our work is the estimation under realistic conditions, taking into consideration power measurements, usage profiles and proxying capabilities.
Resumo:
Este trabalho surge do interesse em substituir os nós de rede óptica baseados maioritariamente em electrónica por nós de rede baseados em tecnologia óptica. Espera-se que a tecnologia óptica permita maiores débitos binários na rede, maior transparência e maior eficiência através de novos paradigmas de comutação. Segundo esta visão, utilizou-se o MZI-SOA, um dispositivo semicondutor integrado hibridamente, para realizar funcionalidades de processamento óptico de sinal necessárias em nós de redes ópticas de nova geração. Nas novas redes ópticas são utilizados formatos de modulação avançados, com gestão da fase, pelo que foi estudado experimentalmente e por simulação o impacto da utilização destes formatos no desempenho do MZI-SOA na conversão de comprimento de onda e formato, em várias condições de operação. Foram derivadas regras de utilização para funcionamento óptimo. Foi também estudado o impacto da forma dos pulsos do sinal no desempenho do dispositivo. De seguida, o MZI-SOA foi utilizado para realizar funcionalidades temporais ao nível do bit e do pacote. Foi investigada a operação de um conversor de multiplexagem por divisão no comprimento de onda para multiplexagem por divisão temporal óptica, experimentalmente e por simulação, e de um compressor e descompressor de pacotes, por simulação. Para este último, foi investigada a operação com o MZI-SOA baseado em amplificadores ópticos de semicondutor com geometria de poço quântico e ponto quântico. Foi também realizado experimentalmente um ermutador de intervalos temporais que explora o MZI-SOA como conversor de comprimento de onda e usa um banco de linhas de atraso ópticas para introduzir no sinal um atraso seleccionável. Por fim, foi estudado analiticamente, experimentalmente e por simulação o impacto de diafonia em redes ópticas em diversas situações. Extendeu-se um modelo analítico de cálculo de desempenho para contemplar sinais distorcidos e afectados por diafonia. Estudou-se o caso de sinais muito filtrados e afectados por diafonia e mostrou-se que, para determinar correctamente as penalidades que ocorrem, ambos os efeitos devem ser considerados simultaneamente e não em separado. Foi estudada a escalabilidade limitada por diafonia de um comutador de intervalos temporais baseado em MZI-SOA a operar como comutador espacial. Mostrou-se também que sinais afectados fortemente por não-linearidades podem causar penalidades de diafonia mais elevadas do que sinais não afectados por não-linearidades. Neste trabalho foi demonstrado que o MZI-SOA permite construir vários e pertinentes circuitos ópticos, funcionando como bloco fundamental de construção, tendo sido o seu desempenho analisado, desde o nível de componente até ao nível de sistema. Tendo em conta as vantagens e desvantagens do MZI-SOA e os desenvolvimentos recentes de outras tecnologias, foram sugeridos tópicos de investigação com o intuito de evoluir para as redes ópticas de nova geração.
Resumo:
O presente trabalho tem por objectivo o estudo de novos dispositivos fotónicos aplicados a sistemas de comunicações por fibra óptica e a sistemas de processamento de sinais RF. Os dispositivos apresentados baseiam-se em processamento de sinal linear e não linear. Dispositivos lineares ópticos tais como o interferómetro de Mach-Zehnder permitem adicionar sinais ópticos com pesos fixos ou sintonizáveis. Desta forma, este dispositivo pode ser usado respectivamente como um filtro óptico em amplitude com duas saídas complementares, ou, como um filtro óptico de resposta de fase sintonizável. O primeiro princípio de operação serve como base para um novo sistema fotónico de medição em tempo real da frequência de um sinal RF. O segundo princípio de operação é explorado num novo sistema fotónico de direccionamento do campo eléctrico radiado por um agregado de antenas, e também num novo compensador sintonizável de dispersão cromática. O processamento de sinal é não linear quando sinais ópticos são atrasados e posteriormente misturados entre si, em vez de serem linearmente adicionados. Este princípio de operação está por detrás da mistura de um sinal eléctrico com um sinal óptico, que por sua vez é a base de um novo sistema fotónico de medição em tempo real da frequência de um sinal RF. A mistura de sinais ópticos em meios não lineares permite uma operação eficiente numa grande largura espectral. Tal operação é usada para realizar conversão de comprimento de onda sintonizável. Um sinal óptico com multiplexagem no domínio temporal de elevada largura de banda é misturado com duas bombas ópticas não moduladas com base em processos não lineares paramétricos num guia de ondas de niobato de lítio com inversão periódica da polarização dos domínios ferroeléctricos. Noutro trabalho, uma bomba pulsada em que cada pulso tem um comprimento de onda sintonizável serve como base a um novo conversor de sinal óptico com multiplexagem no domínio temporal para um sinal óptico com multiplexagem no comprimento de onda. A bomba é misturada com o sinal óptico de entrada através de um processo não linear paramétrico numa fibra óptica com parâmetro não linear elevado. Todos os dispositivos fotónicos de processamento de sinal linear ou não linear propostos são experimentalmente validados. São também modelados teoricamente ou através de simulação, com a excepção dos que envolvem mistura de sinais ópticos. Uma análise qualitativa é suficiente nestes últimos dispositivos.
Resumo:
Este trabalho descreve o desenvolvimento e aplicação de sistemas baseados em detetores gasosos microestruturados, para imagiologia de fluorescência de raios-X por dispersão em energia (EDXRF). A técnica de imagiologia por fluorescência de raios-X assume-se como uma técnica poderosa, não-destrutiva, em análises da distribuição espacial de elementos em materiais. Os sistemas para imagiologia de EDXRF desenvolvidos são constituídos por: um tubo de raios-X, usado para excitar os elementos da amostra; um detetor gasoso microestruturado; e uma lente pinhole que foca a radiação de fluorescência no plano do detetor formando assim a imagem e permitindo a sua ampliação. Por outro lado é estudada a influência do diâmetro da abertura do pinhole bem como do fator de ampliação obtido para a imagem, na resolução em posição do sistema. Foram usados dois conceitos diferentes de detetores gasosos microestruturados. O primeiro, baseado na microestrutura designada por 2D-Micro-Hole & Strip Plate (2D-MHSP) com uma área ativa de 3 3 cm2, enquanto que o segundo, baseado na estrutura 2D-Thick-COBRA (2D-THCOBRA) apresenta uma área ativa de deteção de 10 10 cm2. Estes detetores de raios-X de baixo custo têm a particularidade de funcionar em regime de fotão único permitindo a determinação da energia e posição de interação de cada fotão que chega ao detetor. Deste modo permitem detetar a energia dos fotões X de fluorescência, bem como obter imagens 2D da distribuição desses fotões X para o intervalo de energias desejado. São por isso adequados a aplicações de imagiologia de EDXRF. Os detetores desenvolvidos mostraram resoluções em energia de 17% e 22% para fotões incidentes com uma energia de 5.9 keV, respectivamente para o detetor 2D-MHSP e 2D-THCOBRA e resoluções em posição adequadas para um vasto número de aplicações. Ao longo deste trabalho é detalhado o desenvolvimento, o estudo das características e do desempenho de cada um dos detetores, e sua influência na performance final de cada sistema proposto. Numa fase mais avançada apresentam-se os resultados correspondentes à aplicação dos dois sistemas a diversas amostras, incluindo algumas do nosso património cultural e também uma amostra biológica.