955 resultados para Endurecedores de superfícies
Resumo:
The rehabilitation of edentulous areas with osseointegrated dental implants is a well-documented, predictable procedure in the literature, with high success rates. However, the lack of bone at the recipient bed or proximity to anatomic structures limits the rehabilitation procedure especially at the posterior mandible. Thus, short implants are an alternative treatment for such cases of severe bone resorption. The purpose of this study was to review the success rate of short implants, especially those based in the posterior mandible and to show a clinical case. A literature review was made on electronic databases PubMed and Bireme with articles published between the years 2005 to 2012, using the keywords "short dental implants". It was concluded that the success rates of short implants are similar to those presented by conventional implants but still related to their geometry and surface treatment. Also, short implants can be considered as a viable alternative for the rehabilitation of severely resorbed jaws. However, many authors consider that more research is necessary when a short implant is compared to a long dental implant.
Resumo:
Lasers are widely used tools in many therapeutic modalities in medical lasers and can be divided into low and high intensity. For the treatment of periodontal disease, lowintensity lasers are related to reduce the number of bacteria and to induce inflammatory and analgesic properties. The high intensity lasers can be used in surgical procedures, improving hemostasis, promoting more accurate cuts, removal of dental calculus as well as thermomechanical and photochemical interactions with tissue. The high-intensity laser Erbium impregnated with chromium: YSGG laser has shown satisfactory results when applied in endodontic, restorative denstistry, surgical procedures and non-surgical periodontal treatment. The purpose of this review is to evaluate the studies that investigated the effects of Er, Cr: YSGG laser on the morphology and biocompatibility of titanium and root surfaces irradiated with these lasers, even beyond the effect on the treatment of periodontitis and periimplantitis.
Resumo:
Destruction of bone and periodontal ligament as a result of periodontal disease can lead to anatomical defects in the furcation area. Treatment of these lesions is a major challenge to the clinician. Periodontal instruments have limited access to this area and plaque and calculus removal from root surfaces are extremely difficult. For proper treatment planning a number of factors must be taken into consideration to achieve immediate and long term success. Surgical therapy associated with bone grafts may be a viable option in the treatment of class II furcation defects, aiming to restore lost tissues. The aim of this paper is to report a clinical case where a simplified surgical approach with the use of autogenous graft was used to treat a class II furcation defect Twelve months after the surgery, an increase in clinical attachment level and pocket depth reduction resulted in a complete closure of the furcation lesion.
Resumo:
The aim of this study was to evaluate and compare the roughness and superficial morphology of enamel and a composite restorative resin after different bleaching techniques application. Material and Methods: Bovine incisors were selected and standardized cavities were prepared on the buccal surface, which were restored with composite resin. The teeth were distributed according to the following treatments: G1- bleaching with 10% carbamide peroxide (CP); G2 - bleaching with 38% hydrogen peroxide (HP); and G3 - bleaching with 38% of HP associated to light irradiation. For G1, the bleaching gel was applied for 8 hours daily during 21 days. For G2 and G3, 3 sessions were performed, consisting of 3 applications of 15 minutes each, with 7 days of intervals between the sessions. For G3, the LED (470nm) light was used to activate the bleaching agent for 6 minutes. The surface of enamel and composite resin were evaluated before and after the bleaching procedures using a roughness tester and an atomic force microscope. Results: The results showed significant differences in surface roughness of enamel after bleaching only for G1 (Wilcoxon, p<0.05). For composite resin, neither group showed a statistical difference compared to control (Mann-Whitney, p>0.05). Conclusion: It was concluded that the increase in the roughness of enamel occurred only after bleaching therapy using a gel with 10% of CP. The bleaching procedures evaluated in this investigation did not increase the roughness or cause changes in the superficial morphology of the composite resin.
Resumo:
Coordenação de Aperfeicoamento de Pessoal de Nivel Superior (CAPES)
Resumo:
The success achieved by the use of composite resins in anterior teeth precipitately leads their use in posterior teeth. However, the indiscriminate application of these materials in cavities with several diverse sizes rapidly pointed out their lack of resistance to oclusal and proximal wear. OBJECTIVE: To evaluate the surface roughness of composite resin in relation to finishing and polishing technique. MATERIAL AND METHODS: Eight experimental groups (n = 15) were divided according to finishing and polishing technique: G1 – Z250TM composite resin without surface finishing and polishing; G2 – Z250TM composite resin plus surface finishing and polishing; G3 – P60TM composite resin without surface finishing and polishing; G4 – P60TM composite resin plus surface finishing and polishing; G5 – Prodigy CondensableTM composite resin without surface finishing and polishing; G6 – Prodigy CondensableTM composite resin plus surface finishing and polishing; G7 – SurefillTM composite resin without surface finishing and polishing; G8 – SurefillTM composite resin plus surface finishing and polishing. Three packable and one microhybrid (control group) composite resin was used. The surface roughness was measured using a profilometer at three points in each sample. The results were evaluated by ANOVA and Tukey test (p < 0.05). RESULTS: Prodigy CondensableTM composite resin showed the lowest surface roughness, while SurefillTM showed the highest surface roughness. Comparing the resins used, only between P60TM and SurefillTM there were no statistically significant differences (p > 0,05). CONCLUSION: Surface roughness was lower in all types of resin composites surfaces in contact with Mylar matrix strip than in areas submitted to finishing and polishing procedure.
Resumo:
The knowledge of risk of carried during pregnant is essential for an appropriate treatment using educational and preventives actions to mother for a good care of their oral health and that of children. The main objective of present retrospective study was to identify the risk of caries of pregnants (aged 15-44, mean= 25 years) came to clinic of Preventive Odontology of Araraquara-UNSEP from 1999 to 2007, using 166 medical records obtained by the third pregraduate year students, following the pre-established guidelines. The information collected includes: classification of caries risk diagnosis, pregnancy trimester, carbohydrates ingestion (between or during foods), dental plaques (O'Leary's plaque control registry) and the number of teeth with caries. The statistical analysis used the Chi2 and ANOVA tests. Most of patients showed a 25 % or more of teeth surfaces with dental plaques (92.1 %) and carbohydrates consumption among foods (89.2 %). The mean (SD) of carried and restores teeth was of 7.9 (5.1) and 4.0 (3.4), respectively and the posterior teeth were the more involved by caries/restorations. As regards the diagnosis of caries risk, classification of high risk was observed in the 38.5 % of pregnants, moderate in the 47.6 %) and low in the 13.9 %. There was a statistically significant association (p= 0.001) between the carbohydrates consumption and the diagnosis of caries risk. The plaque's rate was similar in the different trimesters of pregnancy (f= 0.223; p= 0.803). The caries risk of most pregnant women was high or moderate and it was associated with the consumption of carbohydrates.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Pós-graduação em Química - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to evaluate the macroscopy and microstructure of a double setting alpha-tricalcium phosphate bone cement sphere provided with interconnection channels (alpha-TCP-i), as well as the integration of the implant with the rabbits' orbital tissue, through macroscopic analysis and histopathology. The external and internal surfaces of the alpha-TCP-i were evaluated macroscopically and by electron microscopy. Twelve New Zealand rabbits received 12mm implants of alpha-TCP-i following enucleation of the left eye. The clinical assessment was undertaken daily during the first 15 days, followed by fortnightly assessment until the end of the study period. For the morphological analysis, exenteration was performed in 3 animals per experimental period (15, 45, 90 and 180 days). The external and internal surfaces of the implant appeared solid, smooth and compact, with six channels which interconnected centrally. The micro-architecture was characterized by the formation of columns of hexagonal crystals. No signs of infection, exposure, dehiscence of sutures or extrusion of the implant were noted in any of the animals during the entire period of the study. The morphological evaluation demonstrated the presence of a thin capsule around the implant, from whence appeared fibro-vascular projections, which penetrated it through the interconnecting channels. In the first days after the insertion of the implant, an intense inflammatory reaction was noted. At 180 days, however, there were no signs of inflammation. The alpha-tricalcium phosphate cement implant was well tolerated in this rabbit model and appeared to be relatively inert with some fibrovascular ingrowth through the large channels.