INTRODUCTION Aim of this multicentric study:to compare the short-and mid-term results of bare metal stents(BMS)and covered stents(CS)in the Kissing Stent(KS)technique. METHODS Patients undertaking a KS with BMS or CS between January 2017-August 2021 included. Morphological features of plaques were classified as per the extension of calcifications and thrombosis. Every endpoint and outcome was compared in relation to BMS or CS. All patients included received dual anti-platelets DAPT)for at least one month. RESULTS Thirty-four patients enrolled,17 treated with BMS and 17 with CS. Average age 66 years. The 80% of patients were part of TASC C-D categories. DAPT was administered to 82.4%(28/34)of patients with a mean duration of 4.4±1.6 months. Mean follow-up 32.1±17.8 months. Technical Success was 100%. Immediate Clinical Success was reached in 29 cases(85.3%). Immediate and 30-day Clinical Success was higher in CS(64.7% vs 100%, p=.01). Overall Clinical Success at 1-year follow-up was 91.2%,and resulted significantly higher in CS(82.4% vs 100%,p .04). Overall Primary Patency,Assisted Patency,and Secondary Patency at 30 days were 97.1%,97.1%,and 100%,without differences between BMS and CS(94.1% vs 100%,94.1% vs 100%,and 100% vs 100%;p =.7). Two cases(5.9%)of thrombosis were registered,and both occurred within 3 months after the procedure and both in the BMS,without statistical differences with the CS group(11.8% vs 0%,p .48). Both cases of thrombosis occurred in patients who were not treated with dual antiplatelet therapy(33.3% vs 0%,p .027). Survival statistically differed only at the mean follow-up in favour of CS(70.6% and 100%,p .04). CONCLUSIONS The endovascular approach is currently safe and effective in the treatment of AIOD,and KS offers excellent results in particular if performed with CS; however,no statistically significant differences emerged between the two types of stents in terms of patency,reintervention,and complications. DAPT seems to warrant the best results in terms of patency,although there is still no consensus about the ideal duration of administration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The frozen elephant trunk(FET) technique is one of the last evolution in the treatment of complex pathologies of the aortic arch and the descending thoracic aorta.Materials and methods: Between January 2007 and March 2021, a total of 396 patients underwent total aortic arch replacements with the FET technique in our centre.The main indications were thoracic aortic aneurysm(n=104,28.2%), chronic aortic dissection(n=224,53.4%) and acute aortic dissection(n=68, 18.4%). We divided the population in two groups according the position of the distal anastomosis (zone 2 vs zone 3) and the length of the stent graft (< 150 mm vs > 150 mm): conservative group (Zone 2 anastomosis + stent length < 150mm, n. 140 pts) and aggressive group (zone 3 anastomosis + stent length > 150mm, n. 141). Results: The overall 30-day mortality rate was 13%(48/369); the risk factor analysis showed that an aggressive approach was neither a risk factor for major complication (permanent dialysis, tracheostomy, bowel malperfusion and permanent paraplegia) neither for 30-day mortality. The survival rate at 1, 5,10 and 15 years was 87.7%,75%,61.3% and 58.4% respectively. During the follow up, an aortic reintervention was performed in 122 patients (38%), 5 patients received a non-aortic cardiac surgery. Freedom from aortic reintervention at 1-,5- and 10-year was 77%,54% and 44% respectively. The freedom from aortic reintervention was higher in the ‘aggressive’ group (62.5%vs40.0% at 5 years, log-rank=0.056). An aggressive approach was not protective for aortic reintervention at follow up and for death at follow up. Conclusions: The FET technique represents a feasible and efficient option in the treatment of complex thoracic aortic pathologies. An aortic reintervention after FET is very common and the decision-making approach should consider and balance the higher risk of an aggressive approach in terms of post-operative complication versus the higher risk of a second aortic reintervention at follow-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To investigate the use of intravascular optical coherence tomography (IVOCT) for carotid artery stenting (CAS) procedures in patients with atherosclerotic stenosis. Examine possible markers that might identify the onset of new cerebral ischemic lesions on MRI. Specifically, attention was drawn to the morphological features of the used dual layer stent, which could be underestimated during traditional CAS procedures. Secondary goals are to compare the safety and efficacy of different CAS techniques and the accuracy of the vessel analysis software’s on pre-operative CTA examination used to quantify ICA stenosis with the gold standard IVOCT. Material and Methods: Ten patients underwent CAS procedure with flow-arrest technique and IVOCT evaluations prior to and following stent deployment, while five matched patients underwent CAS procedure with distal embolic protection device (EPD) technique. All patients underwent 24-hours 3T MRI examination to check for ischemic lesions; all patients were treated with the same dual-layer stent. Results: Patients with new ischemic lesions demonstrated peculiar stent configuration in the distal end, and a strong Spearman’s rank order correlation was found among the volume of new DWI lesions and the stent configuration in its distal end (Rs: 0.81; p <0.001). No statistically significant differences were observed in the total burden of new ischemic lesions for each technique. The vessel analysis software's on CTA comparison demonstrated a higher diagnostic accuracy in the degree of ICA stenosis compared to the gold standard of IVOCT of the specialized software (ROC curve = 0.63; p = 0.06) compared to the general software (ROC curve = 0.57, p = 0.31). Conclusions: Study’s results support the use of IVOCT to allow recognition of potential features that can predict the onset of new cerebral ischemic lesions. Additionally, IVOCT made it possible to evaluate specialized software's increased accuracy in the pre-operative evaluation of ICA atherosclerotic stenosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abdominal aortic aneurysm is the pathological dilation of the abdominal tract of the aorta and, if left untreated, could undergo rupture with a mortality rate of up to 90%. EVAR is the most common method for AAA treatment consisting in the internal coverage of the aorta with a metallic stent to isolate the aneurysmatic segment from the systemic circulation. Although EVAR technical success rate is high, reinterventions are common. Among the causes of reinterventions typeII endoleaks are the most frequent and consist in retrograde blood flow into the aneurysmal sac from collateral aortic branches. Continued perfusion of the aneurysm sac may lead to aneurysm rupture, therefore AAA sac embolization is performed using metallic coils. However, the presence of artifacts caused by the presence of metallic coils is a limitation because they are radiopaque and can hamper the endoleak during imaging follow-up. This study is aimed at developing a biocompatible hydrogel that could be injected into the aneurysmal sac and may allow a selective intraprocedural sac embolization to reduce post procedural typeII endoleak and eventual AAA rupture. P(BT75BSI25) was synthesized by polycondensation and its biocompatibility tested to assess whether the polymers had no toxic effects. HUVEC cell line was used to mimic the environment in which the polymer would be in contact with, PBS was used as a positive control and MTT assay was performed to evaluate cellular viability after being in contact with the hydrogel. MTT assay showed no significant difference between PBS and P(BT75BSI25), thus the polymer is biocompatible, as confirmed by the analysis of apoptosis by flow cytometry. An aromatic copolymer was obtained via polycondensation and was found to be biocompatible in contact with endothelial cells. This suggests that the hydrogel could be potentially used in the clinical setting for the treatment of type II endoleak after EVAR.