922 resultados para Efficient error correction
Resumo:
In order to induce a therapeutic T lymphocyte response, recombinant viral vaccines are designed to target professional antigen-presenting cells (APC) such as dendritic cells (DC). A key requirement for their use in humans is safe and efficient gene delivery. The present study assesses third-generation lentivectors with respect to their ability to transduce human and mouse DC and to induce antigen-specific CD8+ T-cell responses. We demonstrate that third-generation lentivectors transduce DC with a superior efficiency compared to adenovectors. The transfer of DC transduced with a recombinant lentivector encoding an antigenic epitope resulted in a strong specific CD8+ T-cell response in mice. The occurrence of lower proportions of nonspecifically activated CD8+ cells suggests a lower antivector immunity of lentivector compared to adenovector. Thus, lentivectors, in addition to their promise for gene therapy of brain disorders might also be suitable for immunotherapy.
Resumo:
The present study evaluates the potential of third-generation lentivirus vectors with respect to their use as in vivo-administered T cell vaccines. We demonstrate that lentivector injection into the footpad of mice transduces DCs that appear in the draining lymph node and in the spleen. In addition, a lentivector vaccine bearing a T cell antigen induced very strong systemic antigen-specific cytotoxic T lymphocyte (CTL) responses in mice. Comparative vaccination performed in two different antigen models demonstrated that in vivo administration of lentivector was superior to transfer of transduced DCs or peptide/adjuvant vaccination in terms of both amplitude and longevity of the CTL response. Our data suggest that a decisive factor for efficient T cell priming by lentivector might be the targeting of DCs in situ and their subsequent migration to secondary lymphoid organs. The combination of performance, ease of application, and absence of pre-existing immunity in humans make lentivector-based vaccines an attractive candidate for cancer immunotherapy.
Resumo:
The value of earmarks as an efficient means of personal identification is still subject to debate. It has been argued that the field is lacking a firm systematic and structured data basis to help practitioners to form their conclusions. Typically, there is a paucity of research guiding as to the selectivity of the features used in the comparison process between an earmark and reference earprints taken from an individual. This study proposes a system for the automatic comparison of earprints and earmarks, operating without any manual extraction of key-points or manual annotations. For each donor, a model is created using multiple reference prints, hence capturing the donor within source variability. For each comparison between a mark and a model, images are automatically aligned and a proximity score, based on a normalized 2D correlation coefficient, is calculated. Appropriate use of this score allows deriving a likelihood ratio that can be explored under known state of affairs (both in cases where it is known that the mark has been left by the donor that gave the model and conversely in cases when it is established that the mark originates from a different source). To assess the system performance, a first dataset containing 1229 donors elaborated during the FearID research project was used. Based on these data, for mark-to-print comparisons, the system performed with an equal error rate (EER) of 2.3% and about 88% of marks are found in the first 3 positions of a hitlist. When performing print-to-print transactions, results show an equal error rate of 0.5%. The system was then tested using real-case data obtained from police forces.
Resumo:
Recombinant human TNF (rhTNF) has a selective effect on endothelial cells in tumour angiogenic vessels. Its clinical use has been limited because of its property to induce vascular collapsus. TNF administration through isolated limb perfusion (ILP) for regionally advanced melanomas and soft tissue sarcomas of the limbs was shown to be safe and efficient. When combined to the alkylating agent melphalan, a single ILP produces a very high objective response rate. ILP with TNF and melphalan provided the proof of concept that a vasculotoxic strategy combined to chemotherapy may produce a strong anti-tumour effect. The registered indication of TNF-based ILP is a regional therapy for regionally spread tumours. In soft tissue sarcomas, it is a limb sparing neoadjuvant treatment and, in melanoma in-transit metastases, a curative treatment. Despite its demonstrated regional efficiency TNF-based ILP is unlikely to have any impact on survival. High TNF dosages induce endothelial cells apoptosis, leading to vascular destruction. However, lower TNF dosage produces a very strong effect that is to increase the drug penetration into the tumour, presumably by decreasing the intratumoural hypertension resulting in better tumour uptake. TNF-ILP allowed the identification of the role of alphaVbeta3 integrin deactivation as an important mechanism of antiangiogenesis. Several recent studies have shown that TNF targeting is possible, paving the way to a new opportunity to administer TNF systemically for improving cancer drug penetration. TNF was the first agent registered for the treatment of cancer that improves drug penetration in tumours and selectively destroys angiogenic vessels.
Resumo:
Rapid amplification of cDNA ends (RACE) is a widely used approach for transcript identification. Random clone selection from the RACE mixture, however, is an ineffective sampling strategy if the dynamic range of transcript abundances is large. To improve sampling efficiency of human transcripts, we hybridized the products of the RACE reaction onto tiling arrays and used the detected exons to delineate a series of reverse-transcriptase (RT)-PCRs, through which the original RACE transcript population was segregated into simpler transcript populations. We independently cloned the products and sequenced randomly selected clones. This approach, RACEarray, is superior to direct cloning and sequencing of RACE products because it specifically targets new transcripts and often results in overall normalization of transcript abundance. We show theoretically and experimentally that this strategy leads indeed to efficient sampling of new transcripts, and we investigated multiplexing the strategy by pooling RACE reactions from multiple interrogated loci before hybridization.
Resumo:
Markets, in the real world, are not efficient zero-sum games where hypotheses of the CAPM are fulfilled. Then, it is easy to conclude the market portfolio is not located on Markowitz"s efficient frontier, and passive investments (and indexing) are not optimal but biased. In this paper, we define and analyze biases suffered by passive investors: the sample, construction, efficiency and active biases and tracking error are presented. We propose Minimum Risk Indices (MRI) as an alternative to deal with to market index biases, and to provide investors with portfolios closer to the efficient frontier, that is, more optimal investment possibilities. MRI (using a Parametric Value-at-Risk Minimization approach) are calculated for three stock markets achieving interesting results. Our indices are less risky and more profitable than current Market Indices in the Argentinean and Spanish markets, facing that way the Efficient Market Hypothesis. Two innovations must be outlined: an error dimension has been included in the backtesting and the Sharpe"s Ratio has been used to select the"best" MRI
Resumo:
Global positioning systems (GPS) offer a cost-effective and efficient method to input and update transportation data. The spatial location of objects provided by GPS is easily integrated into geographic information systems (GIS). The storage, manipulation, and analysis of spatial data are also relatively simple in a GIS. However, many data storage and reporting methods at transportation agencies rely on linear referencing methods (LRMs); consequently, GPS data must be able to link with linear referencing. Unfortunately, the two systems are fundamentally incompatible in the way data are collected, integrated, and manipulated. In order for the spatial data collected using GPS to be integrated into a linear referencing system or shared among LRMs, a number of issues need to be addressed. This report documents and evaluates several of those issues and offers recommendations. In order to evaluate the issues associated with integrating GPS data with a LRM, a pilot study was created. To perform the pilot study, point features, a linear datum, and a spatial representation of a LRM were created for six test roadway segments that were located within the boundaries of the pilot study conducted by the Iowa Department of Transportation linear referencing system project team. Various issues in integrating point features with a LRM or between LRMs are discussed and recommendations provided. The accuracy of the GPS is discussed, including issues such as point features mapping to the wrong segment. Another topic is the loss of spatial information that occurs when a three-dimensional or two-dimensional spatial point feature is converted to a one-dimensional representation on a LRM. Recommendations such as storing point features as spatial objects if necessary or preserving information such as coordinates and elevation are suggested. The lack of spatial accuracy characteristic of most cartography, on which LRM are often based, is another topic discussed. The associated issues include linear and horizontal offset error. The final topic discussed is some of the issues in transferring point feature data between LRMs.
Resumo:
OBJECTIVES: To test the validity of a simple, rapid, field-adapted, portable hand-held impedancemeter (HHI) for the estimation of lean body mass (LBM) and percentage body fat (%BF) in African women, and to develop specific predictive equations. DESIGN: Cross-sectional observational study. SETTINGS: Dakar, the capital city of Senegal, West Africa. SUBJECTS: A total sample of 146 women volunteered. Their mean age was of 31.0 y (s.d. 9.1), weight 60.9 kg (s.d. 13.1) and BMI 22.6 kg/m(2) (s.d. 4.5). METHODS: Body composition values estimated by HHI were compared to those measured by whole body densitometry performed by air displacement plethysmography (ADP). The specific density of LBM in black subjects was taken into account for the calculation of %BF from body density. RESULTS: : Estimations from HHI showed a large bias (mean difference) of 5.6 kg LBM (P<10(-4)) and -8.8 %BF (P<10(-4)) and errors (s.d. of the bias) of 2.6 kg LBM and 3.7 %BF. In order to correct for the bias, specific predictive equations were developed. With the HHI result as a single predictor, error values were of 1.9 kg LBM and 3.7 %BF in the prediction group (n=100), and of 2.2 kg LBM and 3.6 %BF in the cross-validation group (n=46). Addition of anthropometrical predictors was not necessary. CONCLUSIONS: The HHI analyser significantly overestimated LBM and underestimated %BF in African women. After correction for the bias, the body compartments could easily be estimated in African women by using the HHI result in an appropriate prediction equation with a good precision. It remains to be seen whether a combination of arm and leg impedancemetry in order to take into account lower limbs would further improve the prediction of body composition in Africans.
Resumo:
Recent experiments have established that information can be encoded in the spike times of neurons relative to the phase of a background oscillation in the local field potential—a phenomenon referred to as “phase-of-firing coding” (PoFC). These firing phase preferences could result from combining an oscillation in the input current with a stimulus-dependent static component that would produce the variations in preferred phase, but it remains unclear whether these phases are an epiphenomenon or really affect neuronal interactions—only then could they have a functional role. Here we show that PoFC has a major impact on downstream learning and decoding with the now well established spike timing-dependent plasticity (STDP). To be precise, we demonstrate with simulations how a single neuron equipped with STDP robustly detects a pattern of input currents automatically encoded in the phases of a subset of its afferents, and repeating at random intervals. Remarkably, learning is possible even when only a small fraction of the afferents (~10%) exhibits PoFC. The ability of STDP to detect repeating patterns had been noted before in continuous activity, but it turns out that oscillations greatly facilitate learning. A benchmark with more conventional rate-based codes demonstrates the superiority of oscillations and PoFC for both STDP-based learning and the speed of decoding: the oscillation partially formats the input spike times, so that they mainly depend on the current input currents, and can be efficiently learned by STDP and then recognized in just one oscillation cycle. This suggests a major functional role for oscillatory brain activity that has been widely reported experimentally.
Resumo:
The objective of this work was to assess the potential of interspecific hybridization of Vitis labruscana and Muscadinia rotundifolia by using artificial cross-pollinations. Microsatellite markers were used to confirm interspecific hybridizations and the identity of the parental genotypes. In crosses in which M. rotundifolia was used as the female parent, no true hybrids were obtained. In the reciprocal crosses, 114 seedlings were identified as true V. labruscana x M. rotundifolia hybrids. Self pollination occurred in direct and in reciprocal crosses. The crossings between 'Bordo' x 'Carlos', 'Magnolia', 'Regale' and' Roanoke', and between' Isabel' x 'Bountiful', 'Carlos', 'Magnolia', 'Regale' and 'Roanoke' were confirmed. The 15 markers evaluated showed that two M. rotundifolia parental genotypes had the same fingerprint profile, indicating a like lyplanting error. The success of hybridization depends mainly on the species and on the cultivar used as the female parent. Microsatellite markers are efficient to confirm the paternity of interspecific F1 hybrids and to determine the correct identity of M. rotundifolia cultivars.
Resumo:
La survie actuelle après correction chirurgicale de la Tétralogie de Fallot (TDF) est de 97% à 12 ans. Les principaux risques à long terme sont une régurgitation pulmonaire ou une sténose récidivante de la sortie droite du coeur, une tachycardie ventriculaire pouvant entrainer une mort subite. Le but de cette étude rétrospective est de comparer la correction chirurgicale de la TDF avec patch pulmonaire versus un conduit valvé xénogreffe. Le collectif se compose de 127 patients entre 2 mois et 16 ans, opérés pour une TDF entre l'année 2000 et 2010. La correction chirurgicale était soit avec un patch, soit avec un conduit valvé à la sortie droite. Cette étude montre d'une part qu'il n'y a pas de différence de survie à un mois entre les deux méthodes opératoires. De plus, elle montre que, lors de la pose d'un patch, il y a plus de sept fois plus d'insuffisances valvulaires modérées à sévères après un mois que lors de la pose d'un conduit valvé. D'autre part, elle démontre que la différence de gradient résiduel à la sortie droite entre la correction avec patch ou conduit n'est pas significative et que la valeur du gradient résiduel à la sortie droite en postopératoire n'est pas représentative du gradient résiduel à un mois. De plus, cette étude prouve que les coronaires aberrantes ainsi qu'un shunt palliatif de Blalock-Taussig sont des facteurs de risque indépendants pour une correction avec un conduit valvé.
Resumo:
In this paper the problem of intensity inhomogeneity athigh magnetic field on magnetic resonance images isaddressed. Specifically, rat brain images at 9.4Tacquired with a surface coil are bias corrected. Wepropose a low- pass frequency model that takes intoaccount not only background-object contours but alsoother important contours inside the image. Twopre-processing filters are proposed: first, to create avolume of interest without contours, and second, toextrapolate the image values of such masked area to thewhole image. Results are assessed quantitatively andvisually in comparison to standard low pass filterapproach, and they show as expected better accuracy inenhancing image intensity.
Resumo:
The study reports a set of forty proteinogenic histidine-containing dipeptides as potential carbonyl quenchers. The peptides were chosen to cover as exhaustively as possible the accessible chemical space, and their quenching activities toward 4-hydroxy-2-nonenal (HNE) and pyridoxal were evaluated by HPLC analyses. The peptides were capped at the C-terminus as methyl esters or amides to favor their resistance to proteolysis and diastereoisomeric pairs were considered to reveal the influence of configuration on quenching. On average, the examined dipeptides are less active than the parent compound carnosine (βAla + His) thus emphasizing the unfavorable effect of the shortening of the βAla residue as confirmed by the control dipeptide Gly-His. Nevertheless, some peptides show promising activities toward HNE combined with a remarkable selectivity. The results emphasize the beneficial role of aromatic and positively charged residues, while negatively charged and H-bonding side chains show a detrimental effect on quenching. As a trend, ester derivatives are slightly more active than amides while heterochiral peptides are more active than their homochiral diastereoisomer. Overall, the results reveal that quenching activity strongly depends on conformational effects and vicinal residues (as evidenced by the reported QSAR analysis), offering insightful clues for the design of improved carbonyl quenchers and to rationalize the specific reactivity of histidine residues within proteins.
Resumo:
Real time glycemia is a cornerstone for metabolic research, particularly when performing oral glucose tolerance tests (OGTT) or glucose clamps. From 1965 to 2009, the gold standard device for real time plasma glucose assessment was the Beckman glucose analyzer 2 (Beckman Instruments, Fullerton, CA), which technology couples glucose oxidase enzymatic assay with oxygen sensors. Since its discontinuation in 2009, today's researchers are left with few choices that utilize glucose oxidase technology. The first one is the YSI 2300 (Yellow Springs Instruments Corp., Yellow Springs, OH), known to be as accurate as the Beckman(1). The YSI has been used extensively for clinical research studies and is used to validate other glucose monitoring devices(2). The major drawback of the YSI is that it is relatively slow and requires high maintenance. The Analox GM9 (Analox instruments, London), more recent and faster, is increasingly used in clinical research(3) as well as in basic sciences(4) (e.g. 23 papers in Diabetes or 21 in Diabetologia). This article is protected by copyright. All rights reserved.