973 resultados para ELECTROMAGNETIC TORQUE RIPPLE


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Control of chaotic instability in a simplified model of a spinning spacecraft with dissipation is achieved using an algorithm derived using Lyapunov's second method. The control method is implemented on a realistic spacecraft parameter configuration which has been found to exhibit chaotic instability for a range of forcing amplitudes and frequencies when a sinusoidally varying torque is applied to the spacecraft. Such a torque, may arise in practice from an unbalanced rotor or from vibrations in appendages. Numerical simulations are performed and the results are studied by means of time history, phase space, Poincare map, Lyapunov characteristic exponents and bifurcation diagrams. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study describes a preliminary examination of the viability and suitability of the physiologic technique electromagnetic articulography (EMA) in investigating lingual fatigue in myasthenia gravis (MG). A 52.9-year-old female diagnosed with MG at the age of 18 years, but who was in remission, participated in the study with a matched control subject. Changes in the duration, speed, and range of tongue-tip and tongue-back movements during repetition of /taka/ over two minutes were investigated. Results revealed that the MG subject did not exhibit significant changes in duration, maximum velocity, maximum acceleration, or the distance travelled by her tongue as measured by EMA over the task. The kinematic results were, in part, expected since the MG subject was in remission. The results, therefore, may not be representative of the majority of individuals with active MG. The examination of the current case did highlight, however, the potential advantages of EMA in providing detailed, objective information regarding lingual kinematics for future investigations of individuals with MG. It also showed that EMA may be sensitive in detecting subclinical kinematic features of fatigue in individuals who are in remission from MG. Finally, EMA led to the identification of possible physiologic factors underlying the CV transform effect, which was evident for the MG subject's syllable productions. In the past, the effect had been assumed to be a purely perceptual-based phenomenon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine the effects of 7 weeks of high- and low-velocity resistance training on strength and sprint running performance in nine male elite junior sprint runners (age 19.0 +/- 1.4 years, best 100 m times 10.89 +/- 0.21 s; mean +/- s). The athletes continued their sprint training throughout the study, but their resistance training programme was replaced by one in which the movement velocities of hip extension and flexion, knee extension and flexion and squat exercises varied according to the loads lifted (i.e. 30-50% and 70-90% of 1-RM in the high- and low-velocity training groups, respectively). There were no between-group differences in hip flexion or extension torque produced at 1.05, 4.74 or 8.42 rad . s(-1), 20 m acceleration or 20 m 'flying' running times, or 1-RM squat lift strength either before or after training. This was despite significant improvements in 20 m acceleration time (P < 0.01), squat strength (P< 0.05), isokinetic hip flexion torque at 4.74 rad . s(-1) and hip extension torque at 1.05 and 4.74 rad . s(-1) for the athletes as a whole over the training period. Although velocity-specific strength adaptations have been shown to occur rapidly in untrained and non-concurrently training individuals, the present results suggest a lack of velocity-specific performance changes in elite concurrently training sprint runners performing a combination of traditional and semi-specific resistance training exercises.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It has long been supposed that the interference observed in certain patterns of coordination is mediated, at least in part, by peripheral afference from the moving limbs. We manipulated the level of afferent input, arising from movement of the opposite limb, during the acquisition of a complex coordination task. Participants learned to generate flexion and extension movements of the right wrist, of 75degrees amplitude, that were a quarter cycle out of phase with a 1-Hz sinusoidal visual reference signal. On separate trials, the left wrist either was at rest, or was moved passively by a torque motor through 50degrees, 75degrees or 100degrees, in synchrony with the reference signal. Five acquisition sessions were conducted on successive days. A retention session was conducted I week later. Performance was initially superior when the opposite limb was moved passively than when it was static. The amplitude and frequency of active movement were lower in the static condition than in the driven conditions and the variation in the relative phase relation across trials was greater than in the driven conditions. In addition, the variability of amplitude, frequency and the relative phase relation during each trial was greater when the opposite limb was static than when driven. Similar effects were expressed in electromyograms. The most marked and consistent differences in the accuracy and consistency of performance (defined in terms of relative phase) were between the static condition and the condition in which the left wrist was moved through 50degrees. These outcomes were exhibited most prominently during initial exposure to the task. Increases in task performance during the acquisition period, as assessed by a number of kinematic variables, were generally well described by power functions. In addition, the recruitment of extensor carpi radialis (ECR), and the degree of co-contraction of flexor carpi radialis and ECR, decreased during acquisition. Our results indicate that, in an appropriate task context, afferent feedback from the opposite limb, even when out of phase with the focal movement, may have a positive influence upon the stability of coordination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Numerical modeling of the eddy currents induced in the human body by the pulsed field gradients in MRI presents a difficult computational problem. It requires an efficient and accurate computational method for high spatial resolution analyses with a relatively low input frequency. In this article, a new technique is described which allows the finite difference time domain (FDTD) method to be efficiently applied over a very large frequency range, including low frequencies. This is not the case in conventional FDTD-based methods. A method of implementing streamline gradients in FDTD is presented, as well as comparative analyses which show that the correct source injection in the FDTD simulation plays a crucial rule in obtaining accurate solutions. In particular, making use of the derivative of the input source waveform is shown to provide distinct benefits in accuracy over direct source injection. In the method, no alterations to the properties of either the source or the transmission media are required. The method is essentially frequency independent and the source injection method has been verified against examples with analytical solutions. Results are presented showing the spatial distribution of gradient-induced electric fields and eddy currents in a complete body model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aims of the present study were to examine electromyographic (EMG) activity of six bilateral trunk muscles during maximal contraction in three cardinal planes, and to determine the direction of contraction that gives maximal activation for each muscle. both for healthy subjects and back-pain patients. Methods: Twenty-eight healthy subjects and 15 back-pain patients performed maximum voluntary contractions in three cardinal planes, Surface EMG signals were recorded from rectus abdominis, external oblique, internal oblique, latissimus dorsi, iliocostalis lumborum, and multifidus bilaterally. Root mean square values of the EMG data were calculated to quantify I the amplitude of EMG signals. Results: For both healthy subjects and back-pain patients. one single direction of contraction was found to give the maximum EMG signals for most muscles. Rectus abdominis demonstrated maximal activity in trunk flexion, external oblique in lateral flexion. internal oblique in axial rotation, and multifidus in extension. For the latissimus dorsi and iliocostalis lumborum. maximal activity was demonstrated in more than one cardinal plane. Conclusion: This study has implications for future research involving normalization of muscle activity to maximal levels required in many trunk EMG studies. As the latissimus dorsi and iliocostalis lumborum demonstrate individual differences in the plane that gives maximal activity, these muscles may require testing in more than one plane.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[1] In this paper a detailed design, development and performances of a 5 GHz microstrip Yagi antenna, which uses a two-dimensional (2-D) electromagnetic band gap (EBG) structure in the ground plane, are presented. The results indicate that the use of the EBG structure improves the radiation pattern of the antenna. The cross polarization is suppressed by properly choosing the period and dimensions of EBGs. Also, the broadside gain is improved in comparison with the analogous antenna without the EBGs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An equivalent unit cell waveguide approach (WGA) to designing 4 multilayer microstrip reflectarray of variable size patches is presented. In this approach, a normal incidence of a plane wave on an infinite periodic array of radiating elements is considered to obtain reflection coefficient phase curves for the reflectarray's elements. It is shown that this problem is equivalent to the problem of reflection of the dominant TEM mode in a waveguide with patches interleaved by layers of dielectric. This waveguide problem is solved using a field matching technique and a method of moments (MoM). Based on this solution, a fast computer algorithm is developed to generate reflection coefficient phase curves for a multilayer microstrip patch reflectarray. The validity of the developed algorithm is tested against alternative approaches and Agilent High Frequency Structure Simulator (HFSS). Having confirmed the validity of the WGA approach, a small offset feed two-layer microstrip patch array is designed and developed. This reflectarray is tested experimentally and shows good performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electromagnetic articulography (EMA) was used to investigate how tongue movement characteristics (i.e., velocity, acceleration, duration, distance) change with. or indeed affect, increased rates of speech. Eight young adult males repeated /ta/ and /ka/ syllables first at a moderate rate that had been modelled at three syllables per second, and then 'as fast as possible'. Distance travelled by the tongue appeared to be the principal lingual kinematic feature manipulated by the group of speakers in producing increased syllable repetition rates, with velocity found to increase, decrease or remain unchanged. Acceleration remained unchanged, except in the case of increased velocity. One participant formed an exception in terms of manipulating distance by exhibiting marginally increased lingual velocities rather than distance changes. This preliminary study serves to direct future EMA-based studies of speech rate control as to the speech tasks that should be employed and the possible underlying anatomical and acoustic bases or constraints that could possibly influence the kinematic strategies employed to increase speech rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Primary objective : To investigate the speed and accuracy of tongue movements exhibited by a sample of children with dysarthria following severe traumatic brain injury (TBI) during speech using electromagnetic articulography (EMA). Methods and procedures : Four children, aged between 12.75-17.17 years with dysarthria following TBI, were assessed using the AG-100 electromagnetic articulography system (Carstens Medizinelektronik). The movement trajectories of receiver coils affixed to each child's tongue were examined during consonant productions, together with a range of quantitative kinematic parameters. The children's results were individually compared against the mean values obtained by a group of eight control children (mean age of 14.67 years, SD 1.60). Main outcomes and results : All four TBI children were perceived to exhibit reduced rates of speech and increased word durations. Objective EMA analysis revealed that two of the TBI children exhibited significantly longer consonant durations compared to the control group, resulting from different underlying mechanisms relating to speed generation capabilities and distances travelled. The other two TBI children did not exhibit increased initial consonant movement durations, suggesting that the vowels and/or final consonants may have been contributing to the increased word durations. Conclusions and clinical implications : The finding of different underlying articulatory kinematic profiles has important implications for the treatment of speech rate disturbances in children with dysarthria following TBI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of near-bed sorting processes on heavy mineral content in suspension is discussed. Sediment concentrations above a rippled bed of mixed quartz and heavy mineral sand were measured under regular nonbreaking waves in the laboratory. Using the traditional gradient diffusion process, settling velocity would be expected to strongly affect sediment distribution. This was not observed during present trials. In fact, the vertical gradients of time-averaged suspension concentrations were found to be similar for the light and heavy minerals, despite their different settling velocities. This behavior implies a convective rather than diffusive distribution mechanism. Between the nonmoving bed and the lowest suspension sampling point, fight and heavy mineral concentration differs by two orders of magnitude. This discrimination against the heavy minerals in the pickup process is due largely to selective entrainment at the ripple face. Bed-form dynamics and the nature of quartz suspension profiles are found to be little affected by the trialed proportion of overall heavy minerals in the bed (3.8-22.1%).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Color model representation allows characterizing in a quantitative manner, any defined color spectrum of visible light, i.e. with a wavelength between 400nm and 700nm. To accomplish that, each model, or color space, is associated with a function that allows mapping the spectral power distribution of the visible electromagnetic radiation, in a space defined by a set of discrete values that quantify the color components composing the model. Some color spaces are sensitive to changes in lighting conditions. Others assure the preservation of certain chromatic features, remaining immune to these changes. Therefore, it becomes necessary to identify the strengths and weaknesses of each model in order to justify the adoption of color spaces in image processing and analysis techniques. This chapter will address the topic of digital imaging, main standards and formats. Next we will set the mathematical model of the image acquisition sensor response, which enables assessment of the various color spaces, with the aim of determining their invariance to illumination changes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques.