927 resultados para Distributed energy resources
Resumo:
With the objective to establish the best metabolizable energy (ME) intake for layers, and the best dietary vegetable oil addition level to optimize egg production, an experiment was carried out with 432 30-week-old Hisex Brown layers. Birds were distributed into nine treatments with six replicates of eight birds each according to a 3 × 3 factorial arrangement, consisting of three daily metabolizable energy intake (280, 300 or 320 kcal/bird/day) and three oil levels (0.00; 0.75 and 1.50 g/bird/day). Daily feed intake was limited to 115, 110 and 105 g/bird in order to obtain the desired energy and oil intake in each treatment. The following parameters were evaluated: initial weight, final weight, body weight change, egg production, egg mass, feed conversion ratio per dozen eggs and per egg mass and energy conversion. There was no influence of the treatments on egg production (%) or egg mass (g/bird/day). Final weight and body weight change were significantly affected by increasing energy intake. Feed conversion ratio per egg mass, feed conversion ratio per dozen eggs and energy conversion significantly worsened as a function of the increase in daily energy intake. An energy intake of 280 kcal/bird/day with no addition of dietary oil does not affect layer performance.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objetivou-se, com este trabalho, estudar as características de carcaça e qualidade da carne do peito depois da inclusão de fitase em dietas para frangos de corte, com diferentes níveis de energia metabolizável aparente corrigida para nitrogênio (EMAn) e proteína bruta (PB) reduzida, suplementadas com aminoácidos essenciais seguindo o conceito de proteína ideal. Foram utilizados 1.500 frangos machos Cobb dos 22 aos 42 dias de idade com peso inicial de 833 ± 7 g e final de 2741 ± 48 g distribuídos em delineamento inteiramente casualizado em esquema fatorial 3x3+1 (três níveis de EMAn - 2950, 3100 e 3250 kcal/kg - e três de PB - 14, 16 e 18% - e um tratamento adicional - controle, sem fitase, com 3100 kcal/kg EMAn, 19,2% de PB e 0,4% de fósforo disponível) em seis repetições com 25 aves cada. Ao final do experimento, duas aves de cada parcela foram sacrificadas para a mensuração do rendimento de carcaça e de cortes e determinação da composição química da carne do peito. Os níveis de energia e proteína em rações com fitase influenciaram (P<0,05) os rendimentos de carcaça, peito e gordura abdominal a porcentagem de umidade, proteína e lipídios no músculo pectoralis major das aves, sendo os níveis de 3100 kcal EMAn/kg e 18% de PB os que proporcionaram maiores rendimentos de carcaça e de peito e menor deposição de gordura abdominal, mas em maior teor de lipídios na carne do peito. Conclui-se que a manipulação da energia em rações com reduzido teor de proteína e suplementadas com aminoácidos e fitase influencia o rendimento de cortes e a qualidade da carne do peito de frangos aos 42 dias.
Resumo:
The metal-insulator or metal-amorphous semiconductor blocking contact is still not well understood. Here, we discuss the steady state characteristics of a non-intimate metal-insulator Schottky barrier. We consider an exponential distribution (in energy) of impurity states in addition to impurity states at a single energy level within the depletion region. We present analytical expressions for the electrical potential, field, thickness of depletion region, capacitance, and charge accumulated in the depletion region. We also discuss ln I versus V(ap) data. Finally, we compare the characteristics in three cases: (i) impurity states at only a single energy level; (ii) uniform energy distribution of impurity states; and (iii) exponential energy distribution of impurity states.In general, the electrical characteristics of Schottky barriers and metal-insulator-metal structures with Schottky barriers depend strongly on the energy distribution of impurity states.
Resumo:
The metal-insulator (or amorphous semiconductor) blocking contact is still not well understood. In the present paper, we discuss the non steady state characteristics of Metal-lnsulator-Metal Structure with non-intimate blocking contacts (i.e. Metal-Oxide-Insulator-Metal Structure). We consider a uniform distribution (in energy) of impurity states in addition to impurity states at a single energy level within the depletion region. We discuss thermal as well as isothermal characteristics and present expressions for the temperature of maximum current (T-m) and a method to calculate the density of uniformly distributed impurity states. The variation of mobility with electrical field has also been considered. Finally we plot the theoretical curves under different conditions. The present results are closing into available experimental results.
Resumo:
The DO experiment at Fermilab's Tevatron will record several petabytes of data over the next five years in pursuing the goals of understanding nature and searching for the origin of mass. Computing resources required to analyze these data far exceed capabilities of any one institution. Moreover, the widely scattered geographical distribution of DO collaborators poses further serious difficulties for optimal use of human and computing resources. These difficulties will exacerbate in future high energy physics experiments, like the LHC. The computing grid has long been recognized as a solution to these problems. This technology is being made a more immediate reality to end users in DO by developing a grid in the DO Southern Analysis Region (DOSAR), DOSAR-Grid, using a available resources within it and a home-grown local task manager, McFarm. We will present the architecture in which the DOSAR-Grid is implemented, the use of technology and the functionality of the grid, and the experience from operating the grid in simulation, reprocessing and data analyses for a currently running HEP experiment.
Resumo:
In the last decade, distributed generation, with its various technologies, has increased its presence in the energy mix presenting distribution networks with challenges in terms of evaluating the technical impacts that require a wide range of network operational effects to be qualified and quantified. The inherent time-varying behavior of demand and distributed generation (particularly when renewable sources are used), need to be taken into account since considering critical scenarios of loading and generation may mask the impacts. One means of dealing with such complexity is through the use of indices that indicate the benefit or otherwise of connections at a given location and for a given horizon. This paper presents a multiobjective performance index for distribution networks with time-varying distributed generation which consider a number of technical issues. The approach has been applied to a medium voltage distribution network considering hourly demand and wind speeds. Results show that this proposal has a better response to the natural behavior of loads and generation than solely considering a single operation scenario.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This paper presents a comparison of reactive power support in distribution networks provided by switched Capacitor Banks (CBs) and Distributed Generators (DGs). Regarding switched CBs, a Tabu Search metaheuristic algorithm is developed to determine their optimal operation with the objective of reducing the power losses in the lines on the system, while meeting network constraints. on the other hand, the optimal operation of DGs is analyzed through an evolutionary Multi-Objective (MO) programming approach. The objectives of such approach are the minimization of power losses and operation cost of the DGs. The comparison of the reactive power support provided by switched CBs and DGs is carried out using a modified IEEE 34 bus distribution test system.
Resumo:
We discuss non-steady state electrical characteristics of a metal-insulator-metal structure. We consider an exponential distribution (in energy) of impurity states in addition to impurity states at a single energy level within the depletion region. We discuss thermal as well as isothermal characteristics and present an expression for the temperature of maximum current (Tm) and a method to calculate the density of exponentially distributed impurity states. We plot the theoretical curves for various sets of parameters and the variation of Tm, and Im (maximum current) with applied potential for various impurity distributions. The present model can explain the available experimental results. Finally we compare the non-steady state characteristics in three cases: (i) impurity states only at a single energy level, (ii) uniform energetic distribution of impurity states, and (iii) exponential energetic distribution of impurity states.
Resumo:
Most of architectures proposed for developing Distributed Virtual Environment (DVE) allow limited number of users. To support the development of applications using the internet infrastructure, with hundred or, perhaps, thousands users logged simultaneously on DVE, several techniques for managing resources, such as bandwidth and capability of processing, must be implemented. The strategy presented in this paper combines methods to attain the scalability required, In special the multicast protocol at application level.
Resumo:
This paper explains why the reliability assessment of energy limited systems requires more detailed models for primary generating resources availability, internal and external generating dispatch and customer demand than the ones commonly used for large power systems and presents a methodology based on the full sequential Montecarlo simulation technique with AC power flow for their long term reliability assessment which can properly include these detailed models. By means of a real example, it is shown how the simplified modeling traditionally used for large power systems leads to pessimistic predictions if it is applied to an energy limited system and also that it cannot predict all the load point adequacy problems. © 2006 IEEE.
Resumo:
Purpose - This paper seeks to address the issue of persistent and widespread drought conditions during 2000 and 2001, which were the apparent cause of the decline of water levels in the reservoirs of Brazilian hydroelectric power plants. Design/methodology/approach - This issue is addressed here through a case study of the hydroclimatology of the Paraíba river basin, in Southeast Brazil, home to four large multi-purpose operational reservoirs. Findings - The data analysis shows that neither changes in the frequency nor magnitude of extreme hydrological events (droughts and floods) nor in annual rainfall amounts can be detected from the existing climate record. The explanation is consistent with the fact that the terrestrial water and energy cycles are tightly, and non-linearly, coupled through evapotranspiration. Research limitations/implications - Therefore small change in the seasonality of rainfall can have a significant impact on the basin's overall hydrologic regime, and thus on the availability of water resources. Originality/value - Often, adaptation and resilience to climate variability are discussed in the context of catastrophic events such as floods and droughts. This study suggests that a different type of impacts, those associated with subtle, yet persistent changes of seasonality in the terrestrial water cycle, cannot be ignored in studies of long-term sustainability of water resources. © Emerald Group Publishing Limited.