869 resultados para Discrete components


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel time domain approach for Structural Health Monitoring (SHM) systems based on Electromechanical Impedance (EMI) principle and Principal Component Coefficients (PCC), also known as loadings. Differently of typical applications of EMI applied to SHM, which are based on computing the Frequency Response Function (FRF), in this work the procedure is based on the EMI principle but all analysis is conducted directly in time-domain. For this, the PCC are computed from the time response of PZT (Lead Zirconate Titanate) transducers bonded to the monitored structure, which act as actuator and sensor at the same time. The procedure is carried out exciting the PZT transducers using a wide band chirp signal and getting their time responses. The PCC are obtained in both healthy and damaged conditions and used to compute statistics indexes. Tests were carried out on an aircraft aluminum plate and the results have demonstrated the effectiveness of the proposed method making it an excellent approach for SHM applications. Finally, the results using EMI signals in both frequency and time responses are obtained and compared. © The Society for Experimental Mechanics 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Information Paper, No 26

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article applies the stochastic-frontier model to examine total factor productivity (tfp) and its components in Latin America between 1960 and 2010. The likelihood-ratio test shows that, for a selection of Latin American countries over the 50 years analysed, the macroeconomic variables of technical inefficiency included in the model generally have a significant effect; and they allow for a better understanding of technical inefficiency throughout the region. The key variables explaining technical inefficiency in the selected countries are public expenditure and the inflation rate; and there is also an inverse relation between technical inefficiency and the extent to which local prices diverge from purchasing power parity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyses three aspects of the share market operated by the Lima Stock Exchange: (i) the short-term relationship between the pricing, direction and volume of order flows; (ii) the components of the spread and the equilibrium point of the limit order book per share, and (iii) the pricing, order direction and trading volume dynamic resulting from shocks in the same variables when lagged. The econometric results for intraday data from 2012 show that the short-run dynamic of the most and least liquid shares in the General Index of the Lima Stock Exchange is explained by the direction of order flow, whose price impact is temporary in both cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho são apresentados o desenvolvimento e a implementação de estratégias de controle digital para regulação automática de tensão e para o amortecimento de oscilações eletromecânicas em um sistema de potência em escala reduzida de 10kVA, localizado no Laboratório de Controle de Sistemas de Potência (LACSPOT), da Universidade Federal do Pará (UFPA). O projeto dos dois controladores é baseado na técnica de alocação polinomial de polos. Para o projeto do Regulador Automático de Tensão (RAT) foi adotado um modelo simplificado, de primeira ordem, da máquina síncrona, cujos parâmetros foram levantados experimentalmente. Para o controlador amortecedor, por sua vez, também chamado de Estabilizador de Sistemas de Potência (ESP), foi utilizado um modelo discreto, do tipo auto regressivo com entrada exógena (ARX). Este modelo foi estimado por meio de técnicas de identificação paramétrica, considerando para tal, o conjunto motor-gerador interligado a um sistema de maior porte (concessionária de energia elétrica). As leis de controle foram embarcadas em um microcontrolador de alto desempenho e, para a medição dos sinais utilizados nos controladores, foi desenvolvida uma instrumentação eletrônica baseada em amplificadores operacionais para o condicionamento dos sinais dos sensores. O sinal de controle é baseado na técnica de modulação por largura de pulso (PWM) e comanda o valor médio da tensão de um conversor CC-CC, o qual é utilizado como circuito de excitação que energiza o enrolamento de campo do gerador. Além disso, o acionamento elétrico das máquinas que compõem o grupo gerador de 10kVA foi projetado e automatizado somando segurança aos operadores e ao componentes deste sistema de geração. Os resultados experimentais demonstraram o bom desempenho obtido pela estratégia proposta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare contrast sensitivity estimated from transient visual evoked potentials (VEPs) elicited by achromatic pattern-reversal and pattern-onset/offset modes. The stimuli were 2-cpd, achromatic horizontal gratings presented either as a 1 Hz pattern reversal or a 300 ms onset/700 ms offset stimulus. Contrast thresholds were estimated by linear regression to amplitudes of VEP components vs. the logarithm of the stimulus contrasts, and these regressions were extrapolated to the zero amplitude level. Contrast sensitivity was defined as the inverse of contrast threshold. For pattern reversal, the relation between the P100 amplitude and log of the stimulus contrast was best described by two separate linear regressions. For the N135 component, a single straight line was sufficient. In the case of pattern onset/offset for both the C1 and C2 components, single straight lines described their amplitude vs. log contrast relations in the medium-to-low contrast range. Some saturation was observed for C2 components. The contrast sensitivity estimated from the low-contrast limb of the P100, from the N135, and from the C2 were all similar but higher than those obtained from the high-contrast limb of the P100 and C1 data, which were also similar to each other. With 2 cpd stimuli, a mechanism possibly driven by the M pathway appeared to contribute to the P100 component at medium-to-low contrasts and to the N135 and C2 components at all contrast levels, whereas another mechanism, possibly driven by the P and M pathways, appeared to contribute to the P100 component at high contrast and C1 component at all contrast levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to isolate and investigate subcortical and cortical lateral interactions involved in flicker perception. We quantified the perceived flicker strength (PFS) in the center of a test stimulus which was simultaneously modulated with a surround stimulus (50% Michelson contrast in both stimuli). Subjects were requested to adjust the modulation depth of a separate matching stimulus that was physically identical to the center of the test stimulus but without the surround. Using LCD goggles, synchronized to the frame rate of a CRT screen, the center and surround could be presented monoptically or dichoptically. In the monoptic condition, center-surround interactions can have both subcortical and cortical origins. In the dichoptic condition, center-surround interactions cannot occur in the retina and the LGN, therefore isolating a cortical mechanism. Results revealed both a strong monoptic (subcortical plus cortical) lateral interaction and a weaker dichoptic (cortical) lateral interaction. Subtraction of the dichoptic from the monoptic data revealed a subcortical mechanism of the lateral interaction. While the modulation of the cortical PFS component showed a low-pass temporal-frequency tuning, the modulation of the subcortical PFS component was maximal at 6 Hz. These findings are consistent with two separate temporal channels influencing the monoptic PFS, each with distinct lateral interactions strength and frequency tuning characteristics. We conclude that both subcortical and cortical lateral interactions modulate flicker perception.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A interferência eletromagnética causada pela linha de energia elétrica afeta negativamente os sinais de instrumentos eletrônicos, especialmente aqueles com baixos níveis de amplitude. Este tipo de interferência é conhecida como interferência de modo comum. Existem muitos métodos e arquiteturas utilizadas para minimizar a influência deste fenômeno de interferência em instrumentos eletrônicos, o mais comum dos quais é a utilização de filtros rejeita banda. Este trabalho apresenta: a análise, desenvolvimento, protótipo e teste de uma nova arquitetura de filtro com característica reconfigurável para instrumentos biomédicos e medição de dados de fluxo em fluido de alta complexidade, com objetivo de reduzir a interferência de modo comum e preservar as componentes do sinal útil na mesma faixa de frequência do ruído, utilizando a técnica de equilíbrio dinâmico de impedância. Além disso, este trabalho pode ser usado em qualquer sistema de medição que também sofra interferência na frequência da linha de alimentação (50/60 Hz, no Brasil e na França, 60 Hz nos Estados Unidos da América). Os blocos de circuitos foram modelados matematicamente e a função de transferência global do circuito fechado foi gerada. Em seguida, o projeto foi descrito e simulado na língua VHDL_AMS e também em um software de simulação eletrônica, usando blocos de componentes discretos, com e sem realimentação. Após análise teórica dos resultados da simulação, um circuito protótipo foi construído e testado usando como entrada um sinal obtido a partir de eletrodos de ECG e Eletrodos Eletroresistivos. Os resultados experimentais do circuito condizem com os da simulação: uma redução de ruído de 98,7% foi obtida em simulações utilizando um sinal sinusoidal, e uma redução de 92% foi realizada utilizando eletrodos de ECG em testes experimentais. Os mesmos testes em eletrodos Eletroresistivos, obtendo o maior valor de 80,3% de redução (durante análise de 3 casos). Em ambos os casos, o sinal útil foi preservado. O método e a sua arquitetura pode ser aplicado para atenuar as interferências que ocorrem na mesma banda de frequência das componentes do sinal útil, preservando ao mesmo tempo estes sinais.