922 resultados para Diameter of Graph
Resumo:
This study defined the main adjuvant characteristics that may influence or help to understand drift formation process in the agricultural spraying. It was evaluated 33 aqueous solutions from combinations of various adjuvants and concentrations. Then, drifting was quantified by means of wind tunnel; and variables such as percentage of droplets smaller than 50 μm (V50), 100 μm (V100), diameter of mean volume (DMV), droplet diameter composing 10% of the sprayed volume (DV0.1), viscosity, density and surface tension. Assays were performed in triplicate, using Teejet XR8003 flat fan nozzles at 200 kPa (medium size droplets). Spray solutions were stained with Brilliant Blue Dye at 0.6% (m/ v). DMV, V100, viscosity cause most influence on drift hazardous. Adjuvant characteristics and respective methods of evaluation have applicability in drift risk by agricultural spray adjuvants.
Resumo:
Kaasukaarihitsauksessa suojakaasuna käytetään yleensä argonin ja hiilidioksidin tai argonin ja heliumin seoksia. Suojakaasu vaikuttaa useisiin hitsausominaisuuksiin, jotka puolestaan vaikuttavat hitsauksen laatuun ja tuottavuuteen. Automaattisella suojakaasun tunnistuksella ja virtausmäärän mittauksella voitaisiin tehdä hitsauksesta paitsi käyttäjän kannalta yksinkertaisempaa, myös laadukkaampaa. Työn tavoite on löytää mahdollisimman edullinen ja kuitenkin mahdollisimman tarkasti kaasuseoksia tunnistava menetelmä, jota voitaisiin hyödyntää MIG/MAG-hitsauskoneeseen sisäänrakennettuna. Selvä etu on, jos menetelmällä voidaan mitata myös kaasun virtausmäärä. Äänennopeus kaasumaisessa väliaineessa on aineen atomi- ja molekyylirakenteesta ja lämpötilasta riippuva ominaisuus, joka voidaan mitata melko edullisesti. Äänennopeuden määritys perustuu ääniaallon kulkuajan mittaamiseen tunnetun pituisella matkalla. Kaasun virtausnopeus on laskettavissa myötä- ja vastavirtaan mitattujen kulkuaikojen erotuksen avulla. Rakennettu mittauslaitteisto koostuu kahdesta ultraäänimuuntimesta, joiden halkaisija on 10 mm ja jotka toimivat sekä lähettimenä että vastaanottimena. Muuntimet ovat 140 mm:n etäisyydellä toisistaan virtauskanavassa, jossa suojakaasu virtaa yhdensuuntaisesti äänen kanssa. Virtauskanava on putki, jossa on käytetty elastisia materiaaleja, jotta ääniaaltojen eteneminen kanavan runkoa pitkin minimoituisi. Kehitetty algoritmi etsii kahden lähetetyn 40 kHz:n taajuisen kanttiaaltopulssin aiheuttaman vasteen perusteella ääniaallon saapumisajanhetken. Useiden mittausten, tulosten lajittelun ja suodatuksen jälkeen tuntemattomalle kaasulle lasketaan lämpötilakompensoitu vertailuluku. Tuntematon kaasu tunnistetaan vertailemalla lukua tunnettujen kaasuseosten mitattuihin vertailulukuihin. Laitteisto tunnistaa seokset, joissa heliumin osuus argonissa on enintään 50 %. Hiilidioksidia sisältävät argonin seokset puolestaan tunnistetaan puhtaaseen hiilidioksidiin asti jopa kahden prosenttiyksikön tarkkuudella. Kaasun tilavuusvirtausmittauksen tarkkuus on noin 1,0 l/min.
Resumo:
The authors present a case of distal common bile duct injury. Ligation of the bile duct and a bypass cholecystojejunostomy were chosen as treatment. Diagnosis of blunt traumatic injury to the extrahepatic biliary ducts may be difficult due to the benign nature of initial bile peritonitis. Surgical treatment for associated abdominal injuries usually makes the diagnosis possible. One of the challenges in the treatment of these injuries relates to the small diameter of the, usually, normal common bile duct. Primary repair and T tube drainage is the best option for non-complex injuries. End-to-end anastomosis and, preferentially, biliary-enteric anastomosis are the best surgical options for more complex injuries. Severe injuries have high complication rates, especially when the distal portion of the common bile duct is affected. Early leaks and late strictures are likely to develop in these situations. Cholecistojejunostomy and ligation of the injuried common bile duct are good surgical options for complex injuries. They carry a low complication rate and consequently low morbidity.
Resumo:
Diplomityön tarkoitus oli selvittää verhopäällystyspastoille sopivia analyysimenetelmiä. Verhopäällystyksessä onnistunut päällystystapahtuma vaatii venymäviskositeetin ja pintajännityksen hyvää hallintaa. Kirjallisuusosassa käsiteltiin verhopäällystystä, verhopäällystyspastojen koostumusta, reologiaa ja pintajännitystä. Kirjallisuusosassa käsiteltiin lisäksi verhopäällystyspastojen reologian ja pintajännityksen mittaamiseen soveltuvia mittausmenetelmiä. Verhopäällystyksen luonteen vuoksi kirjallisuusosassa syvennyttiin venymäviskositeetin ja dynaamisen pintajännityksen mittaamiseen tarkoitettuihin menetelmiin. Kokeellisessa osassa tutkittiin päällystyspastasarjojen reologiaa ja pintajännitystä verhopäällystystä varten. Osaan päällystyspastoista luotiin venymäviskositeettia ja osasta laskettiin pintajännitystä. Venymäviskositeetin mittaamista varten työssä käytettiin ACAV A2 -reometriin liitettyjä teräsreikälevyjä. Dynaamisen pintajännityksen mittaamista varten työssä käytettiin KSV BPA-800P -pintajännitysmittaria. ACAV A2 -reometriin liitettyjen teräsreikälevyjen (reiän sisähalkaisija 0,5 tai 0,7 mm) avulla mitattiin venymäviskositeettia kuvaavia Eulerin lukuarvoja onnistuneesti suurilla kiintoainepitoisuuksilla (50, 60 tai 65 p %). Erikoispaksuntajan määrää lisäämällä onnistuttiin luomaan huomattavaa venymäviskositeettia. Kiintoainepitoisuuden kasvaessa kasvoi myös venymäviskositeetti. Tavanomaisille paksuntajille mitattiin hieman kohonneita venymäviskositeetteja verrattuna referenssipäällystyspastaan. Pigmenttikoostumuksella (kalsiumkarbonaatti/kaoliini) ei näyttänyt olevan vaikutusta venymäviskositeettiin, tai vaikutus oli suhteellisen pieni. Dynaamisen pintajännityksen mittaamista varten käytössä ollut KSV BPA-800P -pintajännitysmittari ei toiminut luotettavasti, vaikka näytteitä laimennettiin. Kiintoainepitoisuudessa 10 p-% olleilla laimennoksilla saavutettiin analysoinnin kannalta parhaat tulokset. Tuloksista saatiin kuitenkin viitteitä, että kyseinen mittari voisi olla potentiaalinen menetelmä dynaamisen pintajännityksen mittaamiseksi.
Resumo:
Focal Nodular Hyperplasia is a benign lesion of the liver, which usually presents with one or two localizations. We report the uncommon case of a 51-year-old female who presents with right upper quadrant pain that worsened in the previous month, without association with feeding. Four hepatic lesions were evidenced at Computerized tomography, the largest being of 8 cm in diameter, of atypical behavior. She was submitted to hepatic segmentectomy of the segment III. The pathologic diagnosis returned focal nodular hyperplasia mixed hyperplastic and adenomatous sub-type. The patient had a good postoperative evolution and is in ambulatory follow-up.
Resumo:
This paper aims to describe the uterine and ovarian ultrasonographic characteristics and Doppler velocimetric features of their arteries in bitches during the periovulatory period. Fifteen estrous cycles in 10 animals were evaluated. The ultrasonographic characteristics, resistance indices (RI) and pulsatility indices (PI) of the uterus and ovaries in each animal were recorded 5 days before and after ovulation (D0). The data were statistically analyzed, and the results were expressed as the mean ± standard error of mean (P<0.05). In results the ultrasonographic features of the uterus were the same on all of the cycles and evaluated days. The uterus had an average diameter of 0.85±0.02cm. An increase in the volume of the ovaries and the diameter of the ovarian follicles were measured. Ovaries had a volume of 0.64±0.06cm³, and the follicles cavities had a diameter of 0.46 ± 0.01 cm on the day of ovulation. After ovulation, it was observed that some follicles not collapse in some cycles. Two days prior to ovulation, the uterine blood perfusion decreased. This decrease remained unchanged until ovulation. Following ovulation, we measured a gradual increase in the uterine perfusion and in the ovarian artery. This artery directed blood flow to the ovaries and increased the intra-ovarian perfusion on the day after ovulation. In conclusion, specific features are observed in the uterus and ovarian ultrasound image and Doppler values of their arteries presented on the periovulatory days and when associated allow to estimate more accurately the date of ovulation.
Resumo:
Tässä tutkimuksessa selvitetään ilman hitsauslisäainetta tapahtuvan laser–TIG–hybridihitsausprosessin soveltuvuus 6 mm ja 8 mm paksujen päittäisliitettyjen S355 K2 ja Laser 355 MC rakenneterästen hitsaukseen. Hitsien tarkastelussa huomio kiinnitetään hitsausnopeuteen, hitsien tunkeumaan, liittämistehokkuuteen, hitsien kovuuteen ja hitsausliitoksen ulkonäköön. Muita tutkittavia asioita ovat laser-TIG-hybridihitsattujen levyjen muodonmuutokset ja suuresta hitsausnopeudesta sekä pienestä t8/5 jäähtymisajasta johtuvat mahdolliset kylmähalkeamat. Laser-TIG-hybridihitsejä verrataan robotti-MAG- ja käsin MAG-hitseihin sekä kaarihitsausstandardin SFS-EN ISO 5817 hitsiluokkien mukaisiin raja-arvoihin. Laser-TIG-hybridihitsausprosessissa TIG-valokaari mahdollistaa tasaisen ja lähes roiskeettoman hitsin ja lasersäde aikaansaa syvän tunkeuman sekä tasalaatuisen juurihitsin. Laser-TIG-hybridihitsausprosessilla 6 mm paksut S355 K2 rakenneteräslevyt on mahdollista hitsata levyn yhdeltä puolelta kerralla valmiiksi. Paksummat 8 mm levyt voidaan hitsata levyn yhdeltä tai molemmilta puolilta suoritettavalla laser-TIG-hybridihitsauksella. Laser-TIG-hybridihitsausprosessilla hitsatut hitsit ovat hyvin siistejä ja lähes roiskeettomia. Verrattaessa laser-TIG-hybridihitsausprosessia muihin hitsausprosesseihin sen voidaan todeta olevan erittäin kilpailukykyinen 6 mm paksujen päittäisliitettyjen rakenneterästen hitsaamisessa, mutta se soveltuu myös 8 mm paksujen rakenneterästen hitsaamiseen. Tutkitut hitsit täyttävät kaarihitsausstandardin SFS-EN ISO 5817 B- ja D-hitsiluokkien mukaiset raja-arvot. Vertailukokeet 6 mm paksulla S355 rakenneteräksellä osoittavat, että yhdeltä puolelta suoritettavan laser-TIG-hybridihitsauksen hitsausnopeus on robotti-MAG-hitsaukseen verrattuna yli nelinkertainen ja MAG-käsinhitsaukseen verrattuna yli viisinkertainen. Laser-TIG-hybridihitsauksessa liittämistehokkuus on noin viisinkertainen robotti-MAGhitsaukseen verrattuna. Molemmilta puolilta suoritettavalla laser-TIG-hybridihitsauksella voidaan 8 mm paksulla S355 rakenneteräksellä saavuttaa noin kolminkertainen hitsausnopeus ja liittämistehokkuus robotti-MAG-hitsaukseen verrattuna. Laser-TIG-hybridihitsauksessa TIG-kaaren tuoman lisälämmön ansiosta suurillakin hitsausnopeuksilla (1 m/min) voidaan saavuttaa edulliset kovuusarvot. Kovuusmittausten tulosten perusteella 6 mm ja 8 mm paksujen S355 K2 ja Laser 355 MC rakenneterästen hitsit eivät ylittäneet kaarihitsausstandardin määrittelemää 350 HV kovuuden enimmäisrajaa. Laser-TIG-hybridihitsauksen edullisesta lämmöntuonnista johtuen levyjen pituus- ja poikittaissuuntaiset muodonmuutokset ovat noin 80 prosenttia pienemmät kuin käsin suoritettavassa MAG-hitsauksessa. Laser-TIG-hybridihitsausprosessilla käytetään I-railoa, mutta robotti-MAG- ja käsin MAG-hitsausprosesseilla joudutaan käyttämään V-railoa, jolloin lämmöntuonti ja siitä johtuvat muodonmuutokset ovat suuremmat. Korkea liittämistehokkuus ja edullinen lämmöntuonti merkitsevät vähäisempiä muodonmuutoksia ja siten merkittäviä säästöjä työ-, materiaali- ja energiakustannuksissa. 8 mm ja sitä paksummilla S355 rakenneteräksillä levyn yhdeltä puolelta suoritettava päittäisliitoksen hitsaaminen on laser-TIG hybridihitsauksella haastavaa, koska yli 200 A:n TIG-kaarivirralla suuri metallisula aiheuttaa avaimenreiän sulkeutumisen ja avaimenreiän alaosaan muodostuu kaasukuplia. Tästä voidaan tehdä sellainen johtopäätös, että päittäisliitettävien levyjen ilmarakoa pitäisi kasvattaa niin suureksi, että avaimenreiän sulavirtaus ei pääse estymään. Yli 0,25 mm:n ilmarako edellyttää lasersäteen vaaputusta tai säteen halkaisijan kasvattamista. Ilmaraon kasvattaminen edellyttää myös lisäaineen käyttöä. Tutkimustulosten perusteella laser-TIG-hybridihitsausprosessilla voidaan saavuttaa merkittäviä etuja ja kustannussäästöjä, joten sen hyödyntämistä kannattaa harkita 8 mm ja sitä ohuempien päittäisliitettävien tuotteiden konepaja- ja tehdastuotannossa. Laser-TIGhybridihitsausprosessi soveltuu esimerkiksi seuraavien tuotteiden hitsaamiseen: päittäisliitettävät levyt, palkit, koneenosat, putket, säiliöt ja erilaiset pyörähdyskappaleet.
Resumo:
Abstract: This paper reports pythiosis in a sheep from southwestern Paraná, Brazil, confirmed by indirect ELISA (Enzime-Linked Immunosorbent Assay) and immunohistochemistry, as well as it describes the macro and microscopic injuries, in order to understand the pathogenicity. A 4-year-old ewe from a flock of 30 Santa Inês sheep, raised semi-extensively with access to a weir, showed cachexia, bilateral enlargement in nasal region, a serous and bloody secretion with a fetid odor from its nose and swollen submandibular and retropharyngeal lymph nodes. Blood collection was performed trough jugular vein puncture in order to make complete blood cell count (CBC) and to obtain serum for the subsequent serological examination. As the hematological counts were within the normal range for sheep, the animal was euthanized and submitted to necropsy. Indirect ELISA resulted positive for pythiosis. Necropsy revealed necrosis of the hard palate with a diameter of 3.5cm and extending up to the nasal cavity, forming a fistula. Submandibular and retropharyngeal lymph nodes were enlarged and edematous on section. Microscopic findings for submandibular and retropharyngeal lymph nodes consisted in moderate infiltration of eosinophils mainly in the subcapsular sinus, characterizing reactive eosinophilic lymphadenitis. The nasal cavity revealed rhinitis and oral cavity stomatitis with necro-eosinophilic and pronounced multifocal granulomatous infiltration and presence of hyphae. Hyphae found in palate and nasal cavity were positive for Pythium insidiosum by Grocott's method and immunohistochemistry, the last one considered to be confirmatory for the pathogen diagnostic. This report has an important epidemiological aspect, as it is the first case of pythiosis in sheep confirmed by serology in South Brazil and an alert of possible infection by the pathogen in floodplains.
Resumo:
Modelling of the slug structure requires a new effort on fundamental research. To clarify some aspects of the horizontal slug flow, an experimental study of the behaviour of two isolated bubbles in a single-phase liquid flow was performed. This procedure was adopted to avoid the overlap of different phenomena induced by a train of long bubbles. The experimental facility consists of a 90-m horizontal PVC pipe with internal diameter of 0,053 m. The behaviour of two single air bubbles travelling in a water flow was studied. Focus was given on the influence of the distance between the bubbles on the velocity of the second bubble. This study allows the understanding of the mechanism of overtaking that takes place right after the slug formation and that precedes the coalescence of bubbles in a slug flow. The results show that bubbles placed behind a liquid slug smaller than a critical value move faster than the leading one. Otherwise, they move slower than the leading one.
Resumo:
The interferometer for low resolution portable Fourier Transform middle infrared spectrometer was developed and studied experimentally. The final aim was a concept for a commercial prototype. Because of the portability, the interferometer should be compact sized and insensitive to the external temperature variations and mechanical vibrations. To minimise the size and manufacturing costs, Michelson interferometer based on plane mirrors and porch swing bearing was selected and no dynamic alignment system was applied. The driving motor was a linear voice coil actuator to avoid mechanical contact of the moving parts. The driving capability for low mirror driving velocities required by the photoacoustic detectors was studied. In total, four versions of such an interferometer were built and experimentally studied. The thermal stability during the external temperature variations and the alignment stability over the mirror travel were measured using the modulation depth of the wide diameter laser beam. Method for estimating the mirror tilt angle from the modulation depth was developed to take account the effect from the non-uniform intensity distribution of the laser beam. The spectrometer stability was finally studied also using the infrared radiation. The latest interferometer was assembled for the middle infrared spectrometer with spectral range from 750 cm−1 to 4500 cm−1. The interferometer size was (197 × 95 × 79) mm3 with the beam diameter of 25 mm. The alignment stability as the change of the tilt angle over the mirror travel of 3 mm was 5 μrad, which decreases the modulation depth only about 0.7 percent in infrared at 3000 cm−1. During the temperature raise, the modulation depth at 3000 cm−1 changed about 1 . . . 2 percentage units per Celsius over short term and even less than 0.2 percentage units per Celsius over the total temperature raise of 30 °C. The unapodised spectral resolution was 4 cm−1 limited by the aperture size. The best achieved signal to noise ratio was about 38 000:1 with commercially available DLaTGS detector. Although the vibration sensitivity requires still improving, the interferometer performed, as a whole, very well and could be further developed to conform all the requirements of the portable and stable spectrometer.
Resumo:
The aim of this study was to evaluate the effect of different crown diameters on the early growth of eucalyptus intercropped with Brachiaria decumbens in a silvopastoral system. The experiment was conducted in a B. decumbens established pasture, where hybrid eucalyptus urograndis (clone GG100) was planted, spaced 8 x 3 m. A randomized block design was used, with six replicates. Treatments consisted of five crown diameters (0.0, 1.0, 1.5, 2.0, and 3.0 m) surrounding the eucalyptus plants. Five weeding hoes were performed throughout the experiment, according to the different crown diameters, aiming to maintain the eucalyptus plants free from B. decumbens interference. At 90, 180, 270, and 360 DAP, the height and the diameter of the eucalyptus plants were evaluated, and at 360 DAP, surface biomass and leaf area were evaluated. At 90 DAP, it was verified that the non-weeded plants had lower growth, compared to those submitted to crowns. Crown diameters of 2.51 and 2.64 m allowed greater growth in height and diameter at ground level of eucalyptus plants, respectively, in all periods evaluated. Biomass production and leaf area per plant at 360 DAP were also influenced by the different crown diameters. It was concluded that crown diameter around 2 meters provided favorable conditions for early growth of eucalyptus and less involvement in the area occupied by forage.
Resumo:
T. absinthioides, Inuleae, Compositae, is a weedy species that is spreading in the irrigation area of the Colorado River, Argentina. This species can be found in normal and saline soils. Morphological and anatomical variables were measured with two salts, sodium chloride and sodium sulfate, with three levels of osmotic potential -0.4, -0.8 and -1.5 MPa, in hydroponic culture, using Hoagland solution as the cultivation media. The total diameter of the roots of plants growing in Na2SO4 and NaCl increased when the osmotic potential was -0.4 MPa. In plants growing in NaCl this may have resulted from the increase in the size of the cortical cells and in plants growing in Na2SO4, the diameter increased may be due to an increase in the cambial activity. The number and length of shoot internodes decreased with increasing salinity, even though this was not statistically significant. In comparison to the control, the total diameter of the shoot increased at -0.4 MPa and decreased with the reduction of the osmotic potential. In comparison to the control, the length of the leaves decreased at -0.4 MPa and the leaves width increased at the same concentration. The palisade parenchyma appeared less developed in saline conditions. In comparison to the control, the number of hairs increased at -0.4 MPa. T. absinthioides acts as a semihalophytic species, according to the salt ranks it tolerates. The mechanisms of adaptation to saline conditions are succulence in root and stunted growth if the salt in the media is NaCl, and the production of haloxeromorphic characters if the salt in the media is Na2 SO4
Resumo:
Peripheral axonal regeneration was investigated in adult male mice of the C57BL/6J (C), BALB/cJ (B) and A/J (A) strains and in their F1 descendants using a predegenerated nerve transplantation model. Four types of transplants were performed: 1) isotransplants between animals of the C, B and A strains; 2) donors of the C strain and recipients of the C x B and C x A breeding; 3) donors of the B strain and recipients of the C x B breeding, and 4) donors of the A strain and recipients of the C x A breeding. Donors had the left sciatic nerve transected and two weeks later a segment of the distal stump was transplanted into the recipient. Four weeks after transplantation the regenerated nerves were used to determine the total number of regenerated myelinated fibers (TMF), diameter of myelinated fibers (FD) and myelin thickness (MT). The highest TMF values were obtained in the groups where C57BL/6J mice were the donors (C to F1 (C x B) = 4658 ± 304; C to F1 (C x A) = 3899 ± 198). Also, A/J grafts led to a significantly higher TMF (A to F1 (C x A) = 3933 ± 565). Additionally, isotransplant experiments showed that when the nerve is previously degenerated, C57BL/6J mice display the largest number of myelinated fibers (C to C = 3136 ± 287; B to B = 2759 ± 170, and A to A = 2835 ± 239). We also observed that when C57BL/6J was the graft donor, FD was the highest and MT did not differ significantly when compared with the other groups. These morphometric results reinforce the idea that Schwann cells and the nerve environment of C57BL/6J provide enough support to the regenerative process. In this respect, the present results support the hypothesis that the non-neuronal cells, mainly Schwann cells, present in the sciatic nerve of C57BL/6J mice are not the main limiting factor responsible for low axonal regeneration.
Resumo:
Twelve female ponies were examined daily for 30 days and classified as ovulating (OV; N = 6; 197 ± 6 kg) or prepubertal (PP; N = 6; 196 ± 9 kg). Follicles were detected by ultrasound and gonadotropins quantified by radioimmunoassay. The mean diameter of the largest follicles was significantly larger in OV (38 ± 1 mm) than in PP (26 ± 2 mm) but there was no difference between groups in the size of the second largest follicle. There were more small follicles (<24 mm) in the PP than in the OV group, but PP fillies had a smaller number of follicles >29 mm than the OV fillies. Follicle-stimulating hormone (FSH) levels did not differ between groups but PP fillies had lower luteinizing hormone (LH) peak (8 ± 1 ng/ml) and basal (4 ± 0.5 ng/ml) levels, lower peak magnitude (2 ± 0.2 ng/ml) and period average (5 ± 0.6 ng/ml) than OV fillies (32 ± 4.5, 8 ± 1.2, 17.1 ± 6, and 15 ± 2.3 ng/ml, respectively). The PP group, in contrast to the OV group, showed no relationship between FSH surge and follicle wave emergence. We conclude that an LH concentration higher than 8 ng/ml is needed for follicle growth to a preovulatory size. Wave emergence and FSH secretion seem to be independent events, probably due to an inhibitory neural system in these PP animals. PP fillies may provide a physiological model for the study of follicle wave emergence which apparently does not depend on gonadotropin levels.
Resumo:
Calcineurin, a Ca2+/calmodulin-dependent phosphatase, is associated with muscle regeneration via NFATc1/GATA2-dependent pathways. However, it is not clear whether calcineurin preferentially affects the regeneration of slow- or fast-twitch muscles. We investigated the effect of a calcineurin inhibitor, cyclosporin A (CsA), on the morphology and fiber diameter of regenerating slow- and fast-twitch muscles. Adult Wistar rats (259.5 ± 9 g) maintained under standard conditions were treated with CsA (20 mg/kg body weight, ip) for 5 days, submitted to cryolesion of soleus and tibialis anterior (TA) muscles on the 6th day, and then treated with CsA for an additional 21 days. The muscles were removed, weighed, frozen, and stored in liquid nitrogen. Cryolesion did not alter the body weight gain of the animals after 21 days of regeneration (P = 0.001) and CsA significantly reduced the body weight gain (15.5%; P = 0.01) during the same period. All treated TA and soleus muscles showed decreased weights (17 and 29%, respectively, P < 0.05). CsA treatment decreased the cross-sectional area of both soleus and TA muscles of cryoinjured animals (TA: 2108 ± 930 vs 792 ± 640 µm²; soleus: 2209 ± 322 vs 764 ± 439 m²; P < 0.001). Histological sections of both muscles stained with Toluidine blue revealed similar regenerative responses after cryolesion. In addition, CsA was able to minimize these responses, i.e., centralized nuclei and split fibers, more efficiently so in TA muscle. These results indicate that calcineurin preferentially plays a role in regeneration of slow-twitch muscle.