968 resultados para Dental Implants. Stomatitis. Periimplantitis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Expenditure on dental and oral health services in Australia is $3.4 billion AUD annually. This is the sixth highest health cost and accounts for 7 % of total national health expenditure. Approximately 49 % of Australian children aged 6 years have caries experience in their deciduous teeth and this is rising. The aetiology of dental caries involves a complex interplay of individual, behavioural, social, economic, political and environmental conditions, and there is increasing interest in genetic predisposition and epigenetic modification. Methods The Oral Health Sub-study; a cross sectional study of a birth cohort began in November 2012 by examining mothers and their children who were six years old by the time of initiation of the study, which is ongoing. Data from detailed questionnaires of families from birth onwards and data on mothers’ knowledge, attitudes and practices towards oral health collected at the time of clinical examination are used. Subjects’ height, weight and mid-waist circumference are taken and Body Mass Index (BMI) computed, using an electronic Bio-Impedance balance. Dental caries experience is scored using the International Caries Detection and Assessment System (ICDAS). Saliva is collected for physiological measures. Salivary Deoxyribose Nucleic Acid (DNA) is extracted for genetic studies including epigenetics using the SeqCap Epi Enrichment Kit. Targets of interest are being confirmed by pyrosequencing to identify potential epigenetic markers of caries risk. Discussion This study will examine a wide range of potential determinants for childhood dental caries and evaluate inter-relationships amongst them. The findings will provide an evidence base to plan and implement improved preventive strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic radiology represents the largest man-made contribution to population radiation doses in Europe. To be able to keep the diagnostic benefit versus radiation risk ratio as high as possible, it is important to understand the quantitative relationship between the patient radiation dose and the various factors which affect the dose, such as the scan parameters, scan mode, and patient size. Paediatric patients have a higher probability for late radiation effects, since longer life expectancy is combined with the higher radiation sensitivity of the developing organs. The experience with particular paediatric examinations may be very limited and paediatric acquisition protocols may not be optimised. The purpose of this thesis was to enhance and compare different dosimetric protocols, to promote the establishment of the paediatric diagnostic reference levels (DRLs), and to provide new data on patient doses for optimisation purposes in computed tomography (with new applications for dental imaging) and in paediatric radiography. Large variations in radiation exposure in paediatric skull, sinus, chest, pelvic and abdominal radiography examinations were discovered in patient dose surveys. There were variations between different hospitals and examination rooms, between different sized patients, and between imaging techniques; emphasising the need for harmonisation of the examination protocols. For computed tomography, a correction coefficient, which takes individual patient size into account in patient dosimetry, was created. The presented patient size correction method can be used for both adult and paediatric purposes. Dental cone beam CT scanners provided adequate image quality for dentomaxillofacial examinations while delivering considerably smaller effective doses to patient compared to the multi slice CT. However, large dose differences between cone beam CT scanners were not explained by differences in image quality, which indicated the lack of optimisation. For paediatric radiography, a graphical method was created for setting the diagnostic reference levels in chest examinations, and the DRLs were given as a function of patient projection thickness. Paediatric DRLs were also given for sinus radiography. The detailed information about the patient data, exposure parameters and procedures provided tools for reducing the patient doses in paediatric radiography. The mean tissue doses presented for paediatric radiography enabled future risk assessments to be done. The calculated effective doses can be used for comparing different diagnostic procedures, as well as for comparing the use of similar technologies and procedures in different hospitals and countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis comprises four intercomplementary parts that introduce new approaches to brittle reaction layers and mechanical compatibility of metalloceramic joints created when fusing dental ceramics to titanium. Several different methods including atomic layer deposition (ALD), sessile drop contact angle measurements, scanning acoustic microscopy (SAM), three-point bending (TPB, DIN 13 927 / ISO 9693), cross-section microscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS) were employed. The first part investigates the effects of TiO2 layer structure and thickness on the joint strength of the titanium-metalloceramic system. Samples with all tested TiO2 thicknesses displayed good ceramics adhesion to Ti, and uniform TPB results. The fracture mode was independent of oxide layer thickness and structure. Cracking occurred deeper inside titanium, in the oxygen-rich Ti[O]x solid solution surface layer. During dental ceramics firing TiO2 layers dissociate and joints become brittle with increased dissolution of oxygen into metallic Ti and consequent reduction in the metal plasticity. To accomplish an ideal metalloceramic joint this needs to be resolved. The second part introduces photoinduced superhydrophilicity of TiO2. Test samples with ALD deposited anatase TiO2 films were produced. Samples were irradiated with UV light to induce superhydrophilicity of the surfaces through a cascade leading to increased amount of surface hydroxyl groups. Superhydrophilicity (contact angle ~0˚) was achieved within 2 minutes of UV radiation. Partial recovery of the contact angle was observed during the first 10 minutes after UV exposure. Total recovery was not observed within 24h storage. Photoinduced ultrahydrophilicity can be used to enhance wettability of titanium surfaces, an important factor in dental ceramics veneering processes. The third part addresses interlayers designed to restrain oxygen dissolution into Ti during dental ceramics fusing. The main requirements for an ideal interlayer material are proposed. Based on these criteria and systematic exclusion of possible interlayer materials silver (Ag) interlayers were chosen. TPB results were significantly better in when 5 μm Ag interlayers were used compared to only Al2O3-blasted samples. In samples with these Ag interlayers multiple cracks occurred inside dental ceramics, none inside Ti structure. Ag interlayers of 5 μm on Al2O3-blasted samples can be efficiently used to retard formation of the brittle oxygen-rich Ti[O]x layer, thus enhancing metalloceramic joint integrity. The most brittle component in metalloceramic joints with 5 μm Ag interlayers was bulk dental ceramics instead of Ti[O]x. The fourth part investigates the importance of mechanical interlocking. According to the results, the significance of mechanical interlocking achieved by conventional surface treatments can be questioned as long as the formation of the brittle layers (mainly oxygen-rich Ti[O]x) cannot be sufficiently controlled. In summary in contrast to former impressions of thick titanium oxide layers this thesis clearly demonstrates diffusion of oxygen from sintering atmosphere and SiO2 to Ti structures during dental ceramics firing and the following formation of brittle Ti[O]x solid solution as the most important factors predisposing joints between Ti and SiO2-based dental ceramics to low strength. This among other predisposing factors such as residual stresses created by the coefficient of thermal expansion mismatch between dental ceramics and Ti frameworks can be avoided with Ag interlayers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Bakhshandeh, Soheila. Periodontal and dental health and oral self-care among adults with diabetes mellitus. Department of Oral Public Health, Institute of Dentistry, Faculty of Medicine, University of Helsinki, Helsinki, Finland. 2011. 49 pp. ISBN 978-952-10-7193-5(paperback). The aim of the present study was to assess oral health and treatment needs among Iranian adults with diabetes according to socio-demographic status, oral hygiene, diabetes related factors, and to investigate the relation between these determinants and oral health. Moreover, the effect of an educational oral health promotion intervention on their oral health and periodontal treatment needs was studied. The target population comprised adults with diabetes in Tehran, Iran. 299 dentate patients with diabetes, who were regular attendants to a diabetic clinic, were selected as the study subjects. Data collection was performed through a clinical dental examination and self-administered structured questionnaire. The questionnaire covered information of the subject s social background, medical history, oral health behaviour and smoking. The clinical dental examinations covered the registration of caries experience (DMFT), community periodontal index (CPI) and plaque index (PI). The intervention provided the adults with diabetes dental health education through a booklet. Reduction in periodontal treatment needs one year after the baseline examination was used as the main outcome. A high prevalence of periodontal pockets among the study population was found; 52% of the participants had periodontal pockets with a pocket depth of 4 to 5 mm and 35% had periodontal pockets with pocket depth of 6 mm or more. The mean of the DMFT index was 12.9 (SD=6.1), being dominated by filled teeth (mean 6.5) and missing teeth (mean 5.0). Oral self-care among adults with diabetes was inadequate and poor oral hygiene was observed in more than 80% of the subjects. The educational oral health promotion decreased periodontal treatment needs more in the study groups than in the control group. The poor periodontal health, poor oral hygiene and insufficient oral self-care observed in this study call for oral health promotion among adult with diabetes. An educational intervention showed that it is possible to promote oral health behaviour and to reduce periodontal treatment needs among adults with diabetes. The simplicity of the model used in this study allows it to be integrated to diabetes programmes in particular in countries with a developing health care system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tsunami waves of the Sumatra-Andaman earthquake on 26 December 2004 claimed approximately 230 000 lives and started the biggest identification operation in Interpol's history. The aim of this study was to resolve methods of the identification and results received. The viewpoint is mainly that of forensic odontology, but also includes other means of identification and results of the medico-legal examination performed in Finland. Of the 5395 victims in Thailand, approximately 2 400 were foreigners from 36 nations including 177 Finnish nationals. Additionally, a Finnish woman perished in Sri Lanka and a severely injured man after the evacuation in a hospital. The final numbers of missing persons and dead bodies registered in the Information Management Centre in Phuket,Thailand, were 3 574 ante-mortem (AM) and 3 681 post-mortem (PM) files. The number of identifications by December 2006 was 3 271 or 89% of the victims registered. Of Finnish victims, 172 have been identified in Thailand and 163 repatriated to Finland. One adult and four children are still missing. For AM data, a list of Finnish missing persons including 178 names was published on 30 December 2004. By February 2005 all useful dental AM data were available. Five persons on the list living in Finland lacked records. Based on the AM database, for the children under age 18 years (n=60) dental identification could be established for 12 (20%). The estimated number for adults (n=112) was 96 (86%). The final identification rate, based on PM examinations in Finland, was 14 (25%) for children (n= 56) and 98 (90%) for adults (n= 109). The number of Finnish victims identified by dental methods, 112 (68%), was high compared to all examined in Thailand (43%). DNA was applied for 26 Finnish children and for 6 adults, fingerprints for 24 and 7, respectively. In 12 cases two methods were applied. Every victim (n=165) underwent in Finland a medico-legal investigation including an autopsy with sampling specimens for DNA, the toxicological and histological investigation. Digital radiographs and computed tomography were taken of the whole body to verify autopsy findings and bring out changes caused by trauma, autolysis, and sampling for DNA in Thailand. Data for identification purposes were also noted. Submersion was the cause of death for 101 of 109 adults (92.7%), and trauma for 8 (7.3%). Injuries were 33 times contributing factors for submersion and 3 times for trauma-based death. Submersion was the cause of death for 51 (92.7%) children and trauma for 4 (7.3%). Injuries were in 3 cases contributing factors in submersion and once in trauma-based death. The success of the dental identification of Finnish victims is mainly based on careful registration of dental records, and on an education program from 1999 in forensic odontology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mg and its alloys become natural biomaterials as the elemental Mg is found in the human body in abundance and their mechanical properties being akin to the natural bone as well as due to their inherent bioabsorbable/bioresorbable property. This paper discusses the development of new Mg alloys and their corrosion characteristics in detail. The latest advancements in coating of Mg alloys to control their degradation rate are also reviewed along with the future challenges that need to be addressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present work is to study the effect of electrical process Parameters (duty cycle and frequency) on morphological, structural, and in-vitro corrosion characteristics of oxide films formed on zirconium by plasma electrolytic oxidation in an electrolyte system consisting of 5 g/L of trisodium orthophosphate. The oxide films fabricated on zirconium by systematically varying the duty cycle and frequency are characterized for its phase composition, surface morphology, chemical composition, roughness, wettability, surface energy, scratch resistance, corrosion resistance, apatite forming ability and osteoblast cell adhesion. X-ray diffraction pattern of all the oxide films showed the predominance of m-ZrO2 phase. Dense and uniform films with thickness varying from 9 to 15 mu m and roughness in the range of 0.62 to 1.03 mu m are formed. Porosity of oxide films is found to be increased with an increase infrequency. The water contact angle results demonstrated that the oxide films exhibited similar hydrophilicity to zirconium substrate. All oxide films showed improved corrosion resistance, as indicated by far lower corrosion current density and passive corrosion potential compared to the zirconium substrate in simulated body fluid environment, and among the four different combinations of duty cycle and frequency employed in the present study, the oxide film formed at 95% duty cycle and 50 Hz frequency (HDLF film) showed superior pitting corrosion resistance, which can be attributed to its pore free morpholOgy. Scratch test results showed that the HDLF oxide film adhered firmly to the substrate by developing a notable scratch resistance at 19.5 +/- 1.2.N. Besides the best corrosion resistance and scratch retistance, the HDLF film also showed good apatite forming ability and osteo sarcoma cell adhesion on its surface. The HDLF oxide film on zirconium with superior surface characteristics is believed to be useful for various types of implants in the dental and orthopedic fields. (C) 2015 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paralysis is a debilitating condition afflicting millions of people across the globe, and is particularly deleterious to quality of life when motor function of the legs is severely impaired or completely absent. Fortunately, spinal cord stimulation has shown great potential for improving motor function after spinal cord injury and other pathological conditions. Many animal studies have shown stimulation of the neural networks in the spinal cord can improve motor ability so dramatically that the animals can even stand and step after a complete spinal cord transaction.

This thesis presents work to successfully provide a chronically implantable device for rats that greatly enhances the ability to control the site of spinal cord stimulation. This is achieved through the use of a parylene-C based microelectrode array, which enables a density of stimulation sites unattainable with conventional wire electrodes. While many microelectrode devices have been proposed in the past, the spinal cord is a particularly challenging environment due to the bending and movement it undergoes in a live animal. The developed microelectrode array is the first to have been implanted in vivo while retaining functionality for over a month. In doing so, different neural pathways can be selectively activated to facilitate standing and stepping in spinalized rats using various electrode combinations, and important differences in responses are observed.

An engineering challenge for the usability of any high density electrode array is connecting the numerous electrodes to a stimulation source. This thesis develops several technologies to address this challenge, beginning with a fully passive implant that uses one wire per electrode to connect to an external stimulation source. The number of wires passing through the body and the skin proved to be a hazard for the health of the animal, so a multiplexed implant was devised in which active electronics reduce the number of wires. Finally, a fully wireless implant was developed. As these implants are tested in vivo, encapsulation is of critical importance to retain functionality in a chronic experiment, especially for the active implants, and it was achieved without the use of costly ceramic or metallic hermetic packaging. Active implants were built that retained functionality 8 weeks after implantation, and achieved stepping in spinalized rats after just 8-10 days, which is far sooner than wire-based electrical stimulation has achieved in prior work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi comparar in vitro o desgaste dental de pré-molares (PM) e molares (M) e sua relação com o valor de dureza Vickers dos materiais utilizados como antagonistas em uma máquina de abrasão simulada para provocar o desgaste nos dentes testados. Os materiais antagonistas utilizados foram VeraBond II (liga de Ni-Cr), Solidex (resina composta) e IPS Empress 2 (cerâmica). Para cada ensaio de dureza, foram preparados seis corpos-de-prova de cada material, os quais foram polidos sob refrigeração, com ciclo de 20 min para cada granulação. Num microdurômetro (HMV-2), foram realizadas três mossas por quadrante, cada uma sob carga de 19,614 N por 30 s, totalizando 12 mossas de base quadrada com ângulo de 136 entre os planos. O teste de abrasão foi realizado numa máquina simuladora de abrasão, freqüência de 265 ciclos/min e 4,4 Hz, com um percurso do antagonista de 10 mm à velocidade de 88 mm/s. Cada dente foi testado em oposição a um antagonista (foram 6 pares dente/material para cada grupo), em água deionizada, sob carga de 5 N, por 150 min, num total de 39.750 ciclos. Foram utilizados dezenove dentes 1 pré-molares, dezenove 3 molares e confeccionados doze antagonistas em cada material em forma de pastilha. Cada grupo de seis dentes foi testado em oposição a seis antagonistas do mesmo material. Ademais, um dente 1 pré-molar (PM) e um dente 3 molar (M) foram testados em oposição ao Plexiglass. Com relação ao desgaste do esmalte dentário (PM+M) segundo o material antagonista, o teste de Kruskal-Wallis evidenciou diferença significativa com p-valor < 0,001 e o teste de Mann-Whitney evidenciou diferença significativa nas comparações PM+M/resina X PM+M/metal (p-valor < 0,001), PM+M/resina X PM+M/cerâmica (p-valor < 0,001) e PM+M/metal X PM+M/cerâmica (p-valor = 0,002). A análise isolada, considerando pré-molares e molares separadamente, encontrou diferença significativa em relação ao desgaste do esmalte dentário no teste de Kruskall-Wallis, porém não detectou diferença significativa no teste de comparação múltipla Mann-Whitney quando comparou o desgaste sofrido pelo PM/metal em relação ao PM/cerâmica. Em relação à dureza Vickers detectou-se diferença significativa da dureza dos materiais no teste de Kruskall-Wallis (p-valor < 0,001) e também no teste de Mann-Whitney nas comparações múltiplas com p-valor = 0,002. Comparando-se a dureza com a perfilometria, observou-se uma correlação estatisticamente significativa (p ≤ 0,05) na correlação negativa (ρ= -0,829) entre a dureza do metal como material antagonista e o desgaste do esmalte dentário do dente molar. Os resultados sugeriram que todo material restaurador indireto estudado causou desgaste ao esmalte dentário quando submetido a forças de simulação de abrasão com carga. Embora tenha sido observada correlação entre dureza e resistência à abrasão, essa correlação foi pouco significativa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo in vitro foi avaliar por meio da fluorescência de Raios X, oefeito remineralizante de dois diferentes princípios bioativos contidos no Desensibilize Nano P (nanopartículas de hidroxiapatita de cálcio) e no GC Tooth Mousse (CPP-ACP,fosfopeptídios de caseína e fosfato de cálcio amorfo) assim como da saliva artificial e do fluoreto de sódio gel neutro no esmalte dental bovino submetido a desafio erosivo. Foram utilizados 20 incisivos bovinos, seccionados na linha amelo-cementária, fixados em resina epóxi e padronizados pela planificação da superfície. Foram obtidos 20 corpos de prova (CP) que foram divididos aleatoriamente em 4 grupos. Todos os dentes foram avaliadosinicialmente para a obtenção da contagem dos elementos fósforo (P), cálcio (Ca) e estrôncio (Sr) interpretados a partir de um espectro de Fluorescência de Raios X obtidos pelo Artax 800. Após uma semana da medição inicial, cada grupo de amostras foi imerso em uma solução de 10 ml de ácido cítrico a 2% (pH 2,6) por 90 minutos. Imediatamente após obtenção dos espectros dos dentes submetidos ao desafio erosivo, cada grupo recebeu seus tratamentos correspondentes. Grupo 1 (Saliva) - saliva; Grupo 2 (Flúor) - Flúor; Grupo 3 (Nano P) - Desensibilize Nano P; Grupo 4 (Recaldent) - GC Tooth Mousse. A leitura e os tratamentos eram realizados a cada sete dias sendo repetidos por de 3 semanas. Foi utilizado inicialmente o teste de Bonferroni para comparação das médias de P, Ca e Sr dentro de cada grupo, com um nível de significância de 0,05 (p=0,05), que demonstrou remineralização efetiva na terceira semana de tratamento no grupo Nano P. Posteriormente foi utilizado o teste T-Student para comparação das médias de P, Ca e Sr entre os diferentes grupos, também com um nível de significância de 0,05 (p=0,05). O grupo Nano P foi mais efetivo do que todos os outros grupos e o grupo Saliva menos efetivo que Fluor e Recaldent após três semanas de tratamento. Nestas condições expirimentais in vitro a pasta Desensibilize Nano P foi eficaz noprocesso de remineralização dental desde a primeira semana de tratamento e estável após 3 semanas de tratamento do que os tratamentos com Saliva, Flúor e GC Tooth Mousse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EU]Hortzetako protesi osoek edentulismo partzial edo osoa jasaten duten pertsonentzat soluzio alternatibo bat suposatzen dute hortz bakarreko inplanteen aurrean, goialdeko edo behealdeko hortz guztiak (edo batzuk) pieza bakarrarekin ordezkatuz [11]. Protesi sistema hauen pieza bakoitzaren fabrikazioak zehaztasun handia eskatzen du eta aztertu beharreko hainbat faktore daude, amaiera produktuaren funtzionamendua egokia izatea nahi bada. Hauetako aspektu asko aurretik gauzatuak izan diren lanetan jorratu dira jadanik, tolerantzia gap-a eta torlojutze sekuentzia bezalako aldagaiei buruz hainbat ikerkuntza eginez [1]. Lan honen bidez, bi faktore hauez gain hezur erlaxazioaren eragina kontuan hartu nahi da, All On Four sistema batean edukiko duen irismena neurtzeko. Horrela, protesiaren fabrikazio edota ezarpenerako baldintza onargarri minimoak ezagutzea espero da, erabiltzailearentzat protesia egokia suerta dadin.