937 resultados para Crystal X-ray


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A basic prerequisite for in vivo X-ray imaging of the lung is the exact determination of radiation dose. Achieving resolutions of the order of micrometres may become particularly challenging owing to increased dose, which in the worst case can be lethal for the imaged animal model. A framework for linking image quality to radiation dose in order to optimize experimental parameters with respect to dose reduction is presented. The approach may find application for current and future in vivo studies to facilitate proper experiment planning and radiation risk assessment on the one hand and exploit imaging capabilities on the other.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The small trees of gas-exchanging pulmonary airways which are fed by the most distal purely conducting airways are called acini and represent the functional gas-exchanging units. The three-dimensional architecture of the acini has a strong influence on ventilation and particle deposition. Due to the difficulty to identify individual acini on microscopic lung sections the knowledge about the number of acini and their biological parameters like volume, surface area, and number of alveoli per acinus are limited. We developed a method to extract individual acini from lungs imaged by high-resolution synchrotron radiation based X-ray tomographic microscopy and estimated their volume, surface area and number of alveoli. Rat acini were isolated by semiautomatically closing the airways at the transition from conducting to gas-exchanging airways. We estimated a mean internal acinar volume of 1.148mm(3), a mean acinar surface area of 73.9mm(2), and a mean of 8470 alveoli per acinus. Assuming that the acini are similarly sized throughout different regions of the lung, we calculated that a rat lung contains 5470±833 acini. We conclude that our novel approach is well suited for the fast and reliable characterization of a large number of individual acini in healthy, diseased, or transgenic lungs of different species including humans.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study of natural magnetic sands is instrumental to investigate the geological aspects of their formation and of the origin of their territory. In particular, Mössbauer spectroscopy provides unique information on their iron content and on the oxidation state of iron in their mineral composition. The Italian coast on the Mediterranean Sea near Rome is known for the presence of highly magnetic black sands of volcanic origin. A study of the room temperature Mössbauer spec- trum, powder X-ray diffraction, energy dispersive X-ray spectroscopy, and magnetic measurements of a sample of black magnetic sand collected on the seashore of the town of Ladispoli is performed. This study reveals magnetite as main constituent with iron in both tetrahedral and octahedral sites. Minor constituents are the iron minerals hematite and ilmenite, the iron containing minerals diopsite, gossular, and allanite, as well as ubiquitous sanidine, quartz, and calcite.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three samples of the skarn mineral rustumite Ca10(Si2O7)2(SiO4)(OH)2Cl2, space group C2/c, a ≈7.6, b ≈ 18.5, c ≈ 15.5 Å, β ≈ 104°, with variable OH, Cl, F content were investigated by electron microprobe, single-crystal X-ray structure refinements, and Raman spectroscopy. “Rust1LCl” is a low chlorine rustumite Ca10(Si2O7)2(SiO4)(OH1.88F0.12)(Cl1.28,OH0.72) from skarns associated with the Rize batholith near Ikizedere, Turkey. “Rust2F” is a F-bearing rustumite Ca10(Si2O7)2(SiO4)(OH1.13F0.87) (Cl1 96OH0.04) from xenoliths in ignimbrites of the Upper Chegem Caldera, Northern Caucasus, Russia. “Rust3LClF” represents a low-Cl, F-bearing rustumite Ca10(Si2O7)2(SiO4)0.87(H4O4)0.13(OH1.01F0.99) (Cl1.00 OH1.00) from altered merwinite skarns of the Birkhin massif, Baikal Lake area, Eastern Siberia, Russia. Rustumite from Birkhin massif is characterized by a significant hydrogarnet-like or fluorine substitution at the apices of the orthosilicate group, leading to specific atomic displacements. The crystal structures including hydrogen positions have been refined from single-crystal X-ray data to R1 = 0.0205 (Rust1_LCl), R1 = 0.0295 (Rust2_F), and R1 = 0.0243 (Rust3_LCl_F), respectively. Depletion in Cl and replacement by OH is associated with smaller unit-cell dimensions. The substitution of OH by F leads to shorter hydrogen bonds O-H⋯F instead of O-H⋯OH. Raman spectra for all samples have been measured and confirm slight strengthening of the hydrogen bonds with uptake of F.This study discusses the complex crystal chemistry of the skarn mineral rustumite and may provide a wider understanding of the chemical reactions related to contact metamorphism of limestones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a new method for fully-automatic landmark detection and shape segmentation in X-ray images. Our algorithm works by estimating the displacements from image patches to the (unknown) landmark positions and then integrating them via voting. The fundamental contribution is that, we jointly estimate the displacements from all patches to multiple landmarks together, by considering not only the training data but also geometric constraints on the test image. The various constraints constitute a convex objective function that can be solved efficiently. Validated on three challenging datasets, our method achieves high accuracy in landmark detection, and, combined with statistical shape model, gives a better performance in shape segmentation compared to the state-of-the-art methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reconstruction of shape and intensity from 2D x-ray images has drawn more and more attentions. Previously introduced work suffers from the long computing time due to its iterative optimization characteristics and the requirement of generating digitally reconstructed radiographs within each iteration. In this paper, we propose a novel method which uses a patient-specific 3D surface model reconstructed from 2D x-ray images as a surrogate to get a patient-specific volumetric intensity reconstruction via partial least squares regression. No DRR generation is needed. The method was validated on 20 cadaveric proximal femurs by performing a leave-one-out study. Qualitative and quantitative results demonstrated the efficacy of the present method. Compared to the existing work, the present method has the advantage of much shorter computing time and can be applied to both DXA images as well as conventional x-ray images, which may hold the potentials to be applied to clinical routine task such as total hip arthroplasty (THA).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we propose a fully automatic, robust approach for segmenting proximal femur in conventional X-ray images. Our method is based on hierarchical landmark detection by random forest regression, where the detection results of 22 global landmarks are used to do the spatial normalization, and the detection results of the 59 local landmarks serve as the image cue for instantiation of a statistical shape model of the proximal femur. To detect landmarks in both levels, we use multi-resolution HoG (Histogram of Oriented Gradients) as features which can achieve better accuracy and robustness. The efficacy of the present method is demonstrated by experiments conducted on 150 clinical x-ray images. It was found that the present method could achieve an average point-to-curve error of 2.0 mm and that the present method was robust to low image contrast, noise and occlusions caused by implants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since approximately two thirds of epileptic patients are non-eligible for surgery, local axonal fiber transections might be of particular interest for them. Micrometer to millimeter wide synchrotron-generated X-ray beamlets produced by spatial fractionation of the main beam could generate such fiber disruptions non-invasively. The aim of this work was to optimize irradiation parameters for the induction of fiber transections in the rat brain white matter by exposure to such beamlets. For this purpose, we irradiated cortex and external capsule of normal rats in the antero-posterior direction with a 4 mm×4 mm array of 25 to 1000 µm wide beamlets and entrance doses of 150 Gy to 500 Gy. Axonal fiber responses were assessed with diffusion tensor imaging and fiber tractography; myelin fibers were examined histopathologically. Our study suggests that high radiation doses (500 Gy) are required to interrupt axons and myelin sheaths. However, a radiation dose of 500 Gy delivered by wide minibeams (1000 µm) induced macroscopic brain damage, depicted by a massive loss of matter in fiber tractography maps. With the same radiation dose, the damage induced by thinner microbeams (50 to 100 µm) was limited to their paths. No macroscopic necrosis was observed in the irradiated target while overt transections of myelin were detected histopathologically. Diffusivity values were found to be significantly reduced. A radiation dose ≤ 500 Gy associated with a beamlet size of < 50 µm did not cause visible transections, neither on diffusion maps nor on sections stained for myelin. We conclude that a peak dose of 500 Gy combined with a microbeam width of 100 µm optimally induced axonal transections in the white matter of the brain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The combination of scaled analogue experiments, material mechanics, X-ray computed tomography (XRCT) and Digital Volume Correlation techniques (DVC) is a powerful new tool not only to examine the 3 dimensional structure and kinematic evolution of complex deformation structures in scaled analogue experiments, but also to fully quantify their spatial strain distribution and complete strain history. Digital image correlation (DIC) is an important advance in quantitative physical modelling and helps to understand non-linear deformation processes. Optical non-intrusive (DIC) techniques enable the quantification of localised and distributed deformation in analogue experiments based either on images taken through transparent sidewalls (2D DIC) or on surface views (3D DIC). X-ray computed tomography (XRCT) analysis permits the non-destructive visualisation of the internal structure and kinematic evolution of scaled analogue experiments simulating tectonic evolution of complex geological structures. The combination of XRCT sectional image data of analogue experiments with 2D DIC only allows quantification of 2D displacement and strain components in section direction. This completely omits the potential of CT experiments for full 3D strain analysis of complex, non-cylindrical deformation structures. In this study, we apply digital volume correlation (DVC) techniques on XRCT scan data of “solid” analogue experiments to fully quantify the internal displacement and strain in 3 dimensions over time. Our first results indicate that the application of DVC techniques on XRCT volume data can successfully be used to quantify the 3D spatial and temporal strain patterns inside analogue experiments. We demonstrate the potential of combining DVC techniques and XRCT volume imaging for 3D strain analysis of a contractional experiment simulating the development of a non-cylindrical pop-up structure. Furthermore, we discuss various options for optimisation of granular materials, pattern generation, and data acquisition for increased resolution and accuracy of the strain results. Three-dimensional strain analysis of analogue models is of particular interest for geological and seismic interpretations of complex, non-cylindrical geological structures. The volume strain data enable the analysis of the large-scale and small-scale strain history of geological structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Holtite, approximately (Al,Ta,square)Al(6)(BO(3))(Si,Sb(3+),As(3+))(Sigma 3)O(12)(O,OH,square)(Sigma 3), is a member of the dumortierite group that has been found in pegmatite, or alluvial deposits derived from pegmatite, at three localities: Greenbushes, Western Australia; Voron'i Tundry, Kola Peninsula, Russia; and Szklary, Lower Silesia, Poland. Holtite can contain >30 wt.% Sb(2)O(3), As(2)O(3), Ta(2)O(5), Nb(2)O(5), and TiO(2) (taken together), but none of these constituents is dominant at a crystallographic site, which raises the question whether this mineral is distinct from dumortierite. The crystal structures of four samples from the three localities have been refined to R(1) = 0.02-0.05. The results show dominantly: Al, Ta, and vacancies at the Al(1) position; Al and vacancies at the Al(2), (3) and (4) sites; Si and vacancies at the Si positions; and Sb, As and vacancies at the Sb sites for both Sb-poor (holtite I) and Sb-rich (holtite II) specimens. Although charge-balance calculations based on our single-crystal structure refinements suggest that essentially no water is present, Fourier transform infrared spectra confirm that some OH is present in the three samples that could be measured. By analogy with dumortierite, the largest peak at 3505-3490 cm(-1) is identified with OH at the O(2) and O(7) positions. The single-crystal X-ray refinements and FTIR results suggest the following general formula for holtite: Al(7-[5x+y+z]/3)(Ta,Nb)(x)square([2x+y+z]/3)BSi(3-y)(Sb,As)(y)O(18-y-z)(OH)(z), where x is the total number of pentavalent cations, y is the total amount of Sb + As, and z <= y is the total amount of OH. Comparison with the electron microprobe compositions suggests the following approximate general formulae Al(5.83)(Ta,Nb)(0.50)square(0.67)BSi(2.50)(Sb,As)(0.50)O(17.00)(OH)(0.50) and Al(5.92)(Ta,Nb)(0.25)square(0.83)BSi(2.00)(Sb,As)(1.00) O(16.00)(OH)(1.00) for holtite I and holtite II respectively. However, the crystal structure refinements do not indicate a fundamental difference in cation ordering that might serve as a criterion for recognizing the two holtites as distinct species, and anion compositions are also not sufficiently different. Moreover, available analyses suggest the possibility of a continuum in the Si/(Sb + As) ratio between holtite I and dumortierite, and at least a partial continuum between holtite I and holtite II. We recommend that use of the terms holtite I and holtite II be discontinued.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Refractive losses in laser-produced plasmas used as gain media are caused by electron density gradients, and limit the energy transport range. The pump pulse is thus deflected from the high-gain region and the short wavelength laser signal also steers away, causing loss of collimation. A Hohlraum used as a target makes the plasma homogeneous and can mitigate refractive losses by means of wave-guiding. A computational study combining a hydrodynamics code and an atomic physics code is presented, which includes a ray-tracing modeling based on the eikonal theory of the trajectory equation. This study presents gain calculations based on population inversion produced by free-electron collisions exciting bound electrons into metastable levels in the 3d94d1(J = 0) → 3d94p1(J = 1) transition of Ni-like Sn. Further, the Hohlraum suggests a dramatic enhancement of the conversion efficiency of collisionally excited x-ray lasing for Ni-like Sn.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High brightness electron sources are of great importance for the operation of the hard X-ray free electron lasers. Field emission cathodes based on the double-gate metallic field emitter arrays (FEAs) can potentially offer higher brightness than the currently used ones. We report on the successful application of electron beam lithography for fabrication of the large-scale single-gate as well as double-gate FEAs. We demonstrate operational high-density single-gate FEAs with sub-micron pitch and total number of tips up to 106 as well as large-scale double-gate FEAs with large collimation gate apertures. The details of design, fabrication procedure and successful measurements of the emission current from the single- and double-gate cathodes are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

X-ray imaging is one of the most commonly used medical imaging modality. Albeit X-ray radiographs provide important clinical information for diagnosis, planning and post-operative follow-up, the challenging interpretation due to its 2D projection characteristics and the unknown magnification factor constrain the full benefit of X-ray imaging. In order to overcome these drawbacks, we proposed here an easy-to-use X-ray calibration object and developed an optimization method to robustly find correspondences between the 3D fiducials of the calibration object and their 2D projections. In this work we present all the details of this outlined concept. Moreover, we demonstrate the potential of using such a method to precisely extract information from calibrated X-ray radiographs for two different orthopedic applications: post-operative acetabular cup implant orientation measurement and 3D vertebral body displacement measurement during preoperative traction tests. In the first application, we have achieved a clinically acceptable accuracy of below 1° for both anteversion and inclination angles, where in the second application an average displacement of 8.06±3.71 mm was measured. The results of both applications indicate the importance of using X-ray calibration in the clinical routine.