957 resultados para Covalent anchorage


Relevância:

10.00% 10.00%

Publicador:

Resumo:

As an innovative transitory anchorage device, the mini-implants deserve to be described with details regarding its use and action during orthodontic treatment. Therefore, this paper intents to present some biomechanic criteria adopted to for a better use of mini-implants as anchorage in anterior retraction (space closure), molar distalization, mesial movement of the molars, intrusion of molars and as support to provisional implant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The need for development of new materials is a natural process in the companies’ technological point of view, seeking improvements in materials and processes. Specifically, among the materials, ceramic exhibit valuable properties, especially the covalent ceramics which have excellent properties for applications which requires the abrasion resistance, hardness, high temperatures, resistence, etc. being a material that has applications in several areas. Most studies are related to improvement of properties, specially fracture toughness that allows the expansion of its application. Among the most promising ceramic materials are silicon nitride (Si3N4) which has excellent properties. The goal of this work was the development and caracterization of Si3N4-based ceramics, doped with yttrium oxide (Y2O3), rar earth concentrate (CTR2O3) and cerium oxide (CeO2) in the same proportion for the evaluation of properties. The powders' mixtures were homogenized, dried and compressed under pressure uniaxial and isostatic. Sintering was carried out in 1850 ⁰C under pressure of 0,1MPa N2 for 1 h with a heating rate of 25 ⁰C / min and cooling in the furnace inertia. The characterizations were performed using Archimedes principle to relative density, weight loss by measuring before and after sintering, phase analysis by X-ray diffraction, microstructure by scanning electron microscope (SEM), hardness and fracture toughness by the method Vickers indentation. The results obtained showed relative density of 97-98%, Vickers hardness 17 to 19 GPa, fracture toughness 5.6 to 6.8 MPa.m1/2, with phases varying from α-SiAlON and β-Si3N4 depending the types of additives used. The results are promising for tribological applications and can be defined according to the types of additives to be used

Relevância:

10.00% 10.00%

Publicador:

Resumo:

National Council for Scientific and Technological Development (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new selective sensor based on molecularly imprinted polymers (MIPs) was developed for the determination of hexazinone (HXZ) in environmental samples. MIPs were synthesized using a non-covalent approach, and selection of the monomers employed in the polymerization reaction was carried out by molecular modeling. Three functional monomers with high (2-vinylpyridine (MP17)) and intermediate (methacrylic acid (MP12) and acrylamide (MP5)) energies of binding to the template (HXZ) were selected for preparation of the MIPs, in order to conduct comparative studies and validate the theoretical data. For sensor construction, carbon pastes were modified with each MIP or NIP (non-imprinted polymer), and HXZ determination was performed using differential pulse adsorptive cathodic stripping voltammetry (DPAdCSV). All parameters affecting the sensor response were optimized. In HCl at pH 2.5, the sensor prepared with MP17 (5% w/w in the paste) showed a dynamic linear range between 1.9 × 10−11 and 1.1 × 10−10 mol L−1, and a detection limit of 2.6 × 10−12 mol L−1, under the following conditions: accumulation time of 200 s at a potential of −0.5V, scan rate of 50 mVs−1, pulse amplitude of 60 mV, and pulse width of 50 ms. The sensor was selective in the presence of other similar compounds, and was successfully applied to the analysis of HXZ in river water samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Covalent “click” cycloaddition was used to functionalize silica substrates with pH-sensitive nanoparticles, thus producing uniform and highly luminescent analytical devices usable in both commercial fluorimeters and fluorescence microscopes. Quantitative and spatially-resolved extracellular pH measurements were successfully achieved on live cardiac fibroblasts with these novel ion-sensitive surfaces.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the efficacy of peroxidase immobilized on corncob powder for the discoloration of dye. Peroxidase was extracted from soybean seed coat, followed by amination of the surface of the tertiary structure. The aminated peroxidase was immobilized on highly activated corncob powder and employed for the discoloration of bromophenol blue. Amination was performed with 10 or 50 mmol.L-1 carbodiimide and 1 mol.L-1 ethylenediamine. The amount of protein in the extract was 0.235 ± 0.011 mg.mL-1 and specific peroxidase activity was 86.06 ± 1.52 µmol min-1 . mg-1, using 1 mmol.L-1 ABTS as substrate. Ten mmol.L-1 and 50 mmol.L-1 aminated peroxidase retained 88 and 100% of the initial activity. Following covalent immobilization on a corncob powder-glyoxyl support, 10 and 50 mmol.L-1 aminated peroxidase retained 74 and 86% of activity, respectively. Derivatives were used for the discoloration of 0.02 mmol.L-1 bromophenol blue solution. After 30 min, 93 and 89% discoloration was achieved with the 10 mmol.L-1 and 50 mmol.L-1 derivatives, respectively. Moreover, these derivatives retained 60% of the catalytic properties when used three times. Peroxidase extracted from soybean seed coat immobilized on a low-cost corncob powder support exhibited improved thermal stability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Permanent teeth impaction is highly prevalent among brazilian people. Its etiology is related to local and general factors association. Permanent teeth retention compromises dental occlusion and when anterior teeth are involved, it also brings esthetics impairments which lead to psychological disturbance. Early diagnosis and adequate treatment are extremely important to solve not only occlusal problems but also psychological aspects. Orthodontic traction of impacted teeth can be conducted by using fixed or removable appliances. Although it depends on patient compliance the use of removable appliances provides an anchorage based on the teeth and the palate reducing undesirable side effects. This paper describes the case of a fourteen years old female patient whose right maxillary central incisor was adequately tractioned with a removable orthodontic appliance. Removable orthodontic devices were used at first to reposition teeth in maxillary anterior area what provided adequate space to allow the placement of the impacted incisor and after were also used to traction and position this tooth. The procedure described seemed to be effective, non expensive and a viable treatment to be performed even on the scope of public health services, extending orthodontic treatment to a higher number of patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to use the finite element method to evaluate the distribution of stresses and strains on the local bone tissue adjacent to the miniplate used for anchorage of orthodontic forces. Methods: A 3-dimensional model composed of a hemimandible and teeth was constructed using dental computed tomographic images, in which we assembled a miniplate with fixation screws. The uprighting and mesial movements of the mandibular second molar that was anchored with the miniplate were simulated. The miniplate was loaded with horizontal forces of 2, 5, and 15 N. A moment of 11.77 N.mm was also applied. The stress and strain distributions were analyzed, and their correlations with the bone remodeling criteria and miniplate stability were assessed. Results: When orthodontic loads were applied, peak bone strain remained within the range of bone homeostasis (100-1500 mu m strain) with a balance between bone formation and resorption. The maximum deformation was found to be 1035 mu m strain with a force of 5 N. At a force of 15 N, bone resorption was observed in the region of the screws. Conclusions: We observed more stress concentration around the screws than in the cancellous bone. The levels of stress and strain increased when the force was increased but remained within physiologic levels. The anchorage system of miniplate and screws could withstand the orthodontic forces, which did not affect the stability of the miniplate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The polemical discussion between orthodontic therapeutic and surgical approaches with relation to borderline cases receives a new impulse with the emergence of temporary anchorage devices. This branch of Orthodontics has brought new treatment perspectives, but it has still been applied empirically, while the various factors involved in determining and conducting the treatment planning are neglected. The objective of the present study is to identify the several factors to be considered in both forms of treatment in order to provide the orthodontist with information that may contribute for the correct decision.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diagnosis and planning stages are critical to the success of orthodontic treatment, in which the orthodontist should have many elements that contribute to the most appropriate decision-making. The orthodontic set-up is an important resource in the planning of corrective orthodontics therapy. It consists of the repositioning of the teeth previously removed from the study dental casts and reassembled on its remaining basis. When properly made, the set-up allows a three-dimensional preview of problems and limitations of the case, assisting in decision-making regarding tooth extractions in cases with problems of space, amount of anchorage loss extent and type of tooth movement, discrepancy of dental arch perimeter, discrepancy of inter-arch tooth volume, among others, indicating the best option for treatment. This paper outlines the most important steps for its confection, an evaluation system and its application in the preparation of orthodontic treatment planning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diagnosis and planning stages are critical to the success of orthodontic treatment, in which the orthodontist should have many elements that contribute to the most appropriate decision-making. The orthodontic set-up is an important resource in the planning of corrective orthodontics therapy. It consists of the repositioning of the teeth previously removed from the study dental casts and reassembled on its remaining basis. When properly made, the set-up allows a three-dimensional preview of problems and limitations of the case, assisting in decision-making regarding tooth extractions in cases with problems of space, amount of anchorage loss extent and type of tooth movement, discrepancy of dental arch perimeter, discrepancy of inter-arch tooth volume, among others, indicating the best option for treatment. This paper outlines the most important steps for its confection, an evaluation system and its application in the preparation of orthodontic treatment planning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contemporary orthodontics has sought, beyond the esthetic, occlusal and functional goals, treatments even faster and with less visits to the orthodontist — especially in patients that require dental extractions in which the generated space becomes a nuisance. The segmented arch technic (SAT), by the use of a "T" loop spring, has provided such results within these requirements. Therefore, this study aimed to appraise and demonstrate the confection, activation and biomechanical control of "T" loop spring, in the group with high anchorage necessity (group A), for retraction of anterior teeth; as well as to present a case report, with high anterior retraction necessity, treated with "T" loop spring.