986 resultados para Coronary angiography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: Plasma levels of C-reactive protein (CRP) are independently associated with risk of coronary heart disease, but whether CRP is causally associated with coronary heart disease or merely a marker of underlying atherosclerosis is uncertain. OBJECTIVE: To investigate association of genetic loci with CRP levels and risk of coronary heart disease. DESIGN, SETTING, AND PARTICIPANTS: We first carried out a genome-wide association (n = 17,967) and replication study (n = 13,615) to identify genetic loci associated with plasma CRP concentrations. Data collection took place between 1989 and 2008 and genotyping between 2003 and 2008. We carried out a mendelian randomization study of the most closely associated single-nucleotide polymorphism (SNP) in the CRP locus and published data on other CRP variants involving a total of 28,112 cases and 100,823 controls, to investigate the association of CRP variants with coronary heart disease. We compared our finding with that predicted from meta-analysis of observational studies of CRP levels and risk of coronary heart disease. For the other loci associated with CRP levels, we selected the most closely associated SNP for testing against coronary heart disease among 14,365 cases and 32,069 controls. MAIN OUTCOME MEASURE: Risk of coronary heart disease. RESULTS: Polymorphisms in 5 genetic loci were strongly associated with CRP levels (% difference per minor allele): SNP rs6700896 in LEPR (-14.8%; 95% confidence interval [CI], -17.6% to -12.0%; P = 6.2 x 10(-22)), rs4537545 in IL6R (-11.5%; 95% CI, -14.4% to -8.5%; P = 1.3 x 10(-12)), rs7553007 in the CRP locus (-20.7%; 95% CI, -23.4% to -17.9%; P = 1.3 x 10(-38)), rs1183910 in HNF1A (-13.8%; 95% CI, -16.6% to -10.9%; P = 1.9 x 10(-18)), and rs4420638 in APOE-CI-CII (-21.8%; 95% CI, -25.3% to -18.1%; P = 8.1 x 10(-26)). Association of SNP rs7553007 in the CRP locus with coronary heart disease gave an odds ratio (OR) of 0.98 (95% CI, 0.94 to 1.01) per 20% lower CRP level. Our mendelian randomization study of variants in the CRP locus showed no association with coronary heart disease: OR, 1.00; 95% CI, 0.97 to 1.02; per 20% lower CRP level, compared with OR, 0.94; 95% CI, 0.94 to 0.95; predicted from meta-analysis of the observational studies of CRP levels and coronary heart disease (z score, -3.45; P < .001). SNPs rs6700896 in LEPR (OR, 1.06; 95% CI, 1.02 to 1.09; per minor allele), rs4537545 in IL6R (OR, 0.94; 95% CI, 0.91 to 0.97), and rs4420638 in the APOE-CI-CII cluster (OR, 1.16; 95% CI, 1.12 to 1.21) were all associated with risk of coronary heart disease. CONCLUSION: The lack of concordance between the effect on coronary heart disease risk of CRP genotypes and CRP levels argues against a causal association of CRP with coronary heart disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Objective To explore potential associations between nursing workload and professional satisfaction among nursing personnel (NP) in Greek Coronary Care Units (CCUs). Method A cross-sectional study was performed involving 66 members of the NP employed in 6 randomly selected Greek CCUs. Job satisfaction was assessed by the IWS and nursing workload by NAS, CNIS and TISS-28. Results The response rate was 77.6%. The reliability of the IWS was α=0.78 and the mean score 10.7 (±2.1, scale range: 0.5-39.7). The most highly valued component of satisfaction was “Pay”, followed by “Task requirements”, “Interaction”, “Professional status”, “Organizational policies” and “Autonomy”. NAS, CNIS and TISS-28 were negatively correlated (p≤0.04) with the following work components: “Autonomy”, “Professional status”, “Interaction” and “Task requirements”. Night shift work independently predicted the score of IWS. Conclusion The findings show low levels of job satisfaction, which are related with nursing workload and influenced by rotating shifts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To compare the use of guideline-recommended medical and interventional therapies in older and younger patients with acute coronary syndromes (ACSs). DESIGN: Prospective cohort study. SETTING: Fifty-five hospitals in Switzerland. PARTICIPANTS: Eleven thousand nine hundred thirty-two patients with ACS enrolled between March 1, 2001, and June 30, 2006. ACS definition included ST-segment elevation myocardial infarction (STEMI), non-ST-segment elevation myocardial infarction (NSTEMI), and unstable angina pectoris (UA). MEASUREMENTS: Use of medical and interventional therapies was determined after exclusion of patients with contraindications and after adjustment for comorbidities. Multivariate logistic regression models were used to calculate odds ratios (ORs) per year increase in age. RESULTS: Elderly patients were less likely to receive acetylsalicylic acid (OR=0.976, 95% confidence interval (CI)=0.969-0.980) or beta-blockers (OR=0.985, 95% CI=0.981-0.989). No age-dependent difference was found for heparin use. Elderly patients with STEMI were less likely to receive percutaneous coronary intervention (PCI) or thrombolysis (OR=0.955, 95% CI=0.949-0.961). Elderly patients with NSTEMI or UA less often underwent PCI (OR=0.943, 95% CI=0.937-0.949). CONCLUSION: Elderly patients across the whole spectrum of ACS were less likely to receive guideline-recommended therapies, even after adequate adjustment for comorbidities. Prognosis of elderly patients with ACS may be improved by increasing adherence to guideline-recommended medical and interventional therapies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of self-calibrating techniques in parallel magnetic resonance imaging eliminates the need for coil sensitivity calibration scans and avoids potential mismatches between calibration scans and subsequent accelerated acquisitions (e.g., as a result of patient motion). Most examples of self-calibrating Cartesian parallel imaging techniques have required the use of modified k-space trajectories that are densely sampled at the center and more sparsely sampled in the periphery. However, spiral and radial trajectories offer inherent self-calibrating characteristics because of their densely sampled center. At no additional cost in acquisition time and with no modification in scanning protocols, in vivo coil sensitivity maps may be extracted from the densely sampled central region of k-space. This work demonstrates the feasibility of self-calibrated spiral and radial parallel imaging using a previously described iterative non-Cartesian sensitivity encoding algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME : Actuellement la brachythérapie endovasculaire reste le seul traitement efficace pour la resténose intrastent. Malgré ceci, la limitation majeure de cette technique est la resténose aux extrémités du stent (effet de bord) due à une couverture incomplète par la source radioactive (geographical miss). Le ballon coupant et qui ne glisse pas pourrait limiter le barotraumatisme engendré par la dilatation et qui avec la diminution de la radiation aux extrémités de la source radioactive, est à la base du geographical miss. Cette étude prospective a pour but d'examiner l'efficacité du traitement de la resténose intrastent par la combinaison d'angioplastie avec cutting ballon et β - irradiation. Le registre « Radiation in Europe NOvoste » (RENO) inclut tous les patients traités par β - irradiation coronaire avec le système Beta-CathTM System (Novoste Corporation, Brussels, Belgium) n'ayant pas été inclus dans une autre étude randomisée. Un premier sous-groupe de ces patients (groupe 1, n=166), représente les patients traités par cutting ballon et β - irradiation intra coronaire. Ce groupe a été défini d'une manière prospective et les résultats cliniques à 6 mois ont été comparés par rapport aux autres patients qui ont reçu un traitement par dilatation coronaire conventionnelle et β - irradiation (groupe 2, n=712). A 6 mois de suivi, on a retrouvé une différence significative entre les 2 groupes par rapport à la nécessité d'une nouvelle revascularisation du vaisseau préalablement traité (10,2% de récidive dans le groupe 1 contre 16,6 % dans le groupe 2 , p=0,04). Le nombre d'événements cardiaques majeurs (mortalité, infarctus du myocarde et revascularisation) a également été diminué de manière significative (10,8% contre 19,2% ; />=0,01). Cette observation a été confirmée par une analyse multivariée qui indique un risque diminué pour les événements cardiaques majeurs à 6 mois, (rapport de côtes : 0,49 ; intervalle de confiance 0,27-0,88 ; p=0,02). Comparé à l'angioplastie coronarienne avec ballon conventionnel, l'utilisation de cutting ballon avant la β - irradiation dans le traitement de la resténose intrastent démontre une meilleure évolution clinique à 6 mois. ABSTRACT: At present, vascular brachytherapy is the only efficient therapy for in-stent restenosis. Nevertheless edge restenosis often relat¬ed to geographical miss has been identified as a major limitation of the technique. The non-slippery cutting balloon has the potential to limit vascular barotraumas which, together with low-dose irradiation at both ends of the radioactive source, are the prerequisite for geographical miss. This prospective study aimed to examine the efficacy of combining cut¬ting balloon angioplasty and brachytherapy for in-stent restenosis. The Radiation in Europe NOvoste (RENO) registry prospectively tracked all patients who had been treated by coronary β-radiation with the Beta-CathTM System (Novoste Corporation. Brussels, Belgium) but were not included in a randomized radiation trial, A subgroup of patients with in-stent restenosis treated by cutting balloon angioplasty and coronary β-radiation (group 1, n = 166) was prospectively defined, and clinical outcomes of patients at 6 months were compared with those of patients treated by conventional angioplasty and coronary β -radiation (group 2, n = 712). At 6-month follow-up, there was a significant difference between groups 1 and 2 in- target vessel revascularization (10.2% versus 16.6% respectively; p = 0.04) and in the incidence of major adverse clinical events (MACE) including, death, myocardial infarction, and revascularization (10.8% versus 19.2%; p= 0.01). This observation was confirmed by a multivariate analysis indicating a. lower risk for MACE at 6 months (odds ratio: 0.49; confidence intervals: 0.27-0.88; p = 0.02). Compared to conventional angioplasty, cutting balloon angio¬plasty prior to coronary beta-radiation with the Beta-CathTM System seems to improve the 6-month clinical outcome in patients with in-stent restenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The relevance of the SYNTAX score for the particular case of patients with acute ST- segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PPCI)  has previously only been studied in the setting of post hoc analysis of large prospective randomized clinical trials. A "real-life" population approach has never been explored before. The aim of this study was to evaluate the impact of the SYNTAX score for the prediction of the myocardial infarction size, estimated by the creatin-kinase (CK) peak value, using the SYNTAX score in patients treated with primary coronary intervention for acute ST-segment elevation myocardial infarction. Methods The primary endpoint of the study was myocardial infarction size as measured by the CK peak value. The SYNTAX score was calculated retrospectively in 253 consecutive patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PPCI) in a large tertiary referral center in Switzerland, between January 2009 and June 2010. Linear regression analysis was performed to compare myocardial infarction size with the SYNTAX score. This same endpoint was then stratified according to SYNTAX score tertiles: low <22 (n=178), intermediate [22-32] (n=60), and high >=33 (n=15). Results There were no significant differences in terms of clinical characteristics between the three groups. When stratified according to the SYNTAX score tertiles, average CK peak values of 1985 (low<22), 3336 (intermediate [22-32]) and 3684 (high>=33) were obtained with a p-value <0.0001. Bartlett's test for equal variances between the three groups was 9.999 (p-value <0.0067). A moderate Pearson product-moment correlation coefficient (r=0.4074) with a high statistical significance level (p-value <0.0001) was found. The coefficient of determination (R^2=0.1660) showed that approximately 17% of the variation of CK peak value (myocardial infarction size) could be explained by the SYNTAX score, i.e. by the coronary disease complexity. Conclusion In an all-comers population, the SYNTAX score is an additional tool in predicting myocardial infarction size in patients treated with primary percutaneous coronary intervention (PPCI). The stratification of patients in different risk groups according to SYNTAX enables to identify a high-risk population that may warrant particular patient care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rupture of unstable plaques may lead to myocardial infarction or stroke and is the leading cause of morbidity and mortality in western countries. Thus, there is a clear need for identifying these vulnerable plaques before the rupture occurs. Atherosclerotic plaques are a challenging imaging target as they are small and move rapidly, especially in the coronary tree. Many of the currently available imaging tools for clinical use still provide minimal information about the biological characteristics of plaques, because they are limited with respect to spatial and temporal resolution. Moreover, many of these imaging tools are invasive. The new generation of imaging modalities such as magnetic resonance imaging, nuclear imaging such as positron emission tomography and single photon emission computed tomography, computed tomography, fluorescence imaging, intravascular ultrasound, and optical coherence tomography offer opportunities to overcome some of these limitations. This review discusses the potential of these techniques for imaging the unstable plaque.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Interventional catheterization is being increasingly used for relief of residual lesions in congenital heart disease. Exact anatomical imaging is crucial in the planning of an intervention. This can be provided non-invasively and without radiation by contrast-enhanced MR angiography (CEMRA). Aim: To evaluate the accuracy of the measurements of the vessels obtained by CEMRA in comparison to those obtained by conventional X-ray angiography (CXA). Methods: Retrospective blinded measurement of the diameters of aorta and pulmonary arteries on the CEMRA and CXA images, in the same locations. Comparison of the results by Pearson correlation and by calculating the limits of agreement. Results: Twenty-one children with congenital heart disease, mean age 5.6 +- 5.2 years, weight 21.1 +- 18.4 kg, underwent CEMRA and catheterization for assessment or treatment of a residual lesion. The time interval between the CEMRA and the CXA examination was 2.6 +- 2.3 months. A total of 98 measurements, 37 of the aorta and 61 of the pulmonary arteries were performed on the images obtained by each technique. The correlation between CEMRA and CXA measurements was excellent, r = 0.97, p < 0.0001. The mean difference between the two techniques was 0.018 +- 1.1mm; the limits of agreement were -2.14 and +2.18mm. Similar agreement was found for measures of the aorta (r +- 0.97, mean difference 0.20 = 1.08 mm) and of the pulmonary arteries (r +- 0.97, mean difference 0.048 = 0.89 mm). Conclusions: CEMRA provide accurate quantitative anatomical information, which highly agrees with CXA data, and can therefore be used for planning interventional catheterization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although both inflammatory and atherosclerosis markers have been associated with coronary heart disease (CHD) risk, data directly comparing their predictive value are limited. The authors compared the value of 2 atherosclerosis markers (ankle-arm index (AAI) and aortic pulse wave velocity (aPWV)) and 3 inflammatory markers (C-reactive protein (CRP), interleukin-6 (IL-6), and tumor necrosis factor-alpha (TNF-alpha)) in predicting CHD events. Among 2,191 adults aged 70-79 years at baseline (1997-1998) from the Health, Aging, and Body Composition Study cohort, the authors examined adjudicated incident myocardial infarction or CHD death ("hard" events) and "hard" events plus hospitalization for angina or coronary revascularization (total CHD events). During 8 years of follow-up between 1997-1998 and June 2007, 351 participants developed total CHD events (197 "hard" events). IL-6 (highest quartile vs. lowest: hazard ratio = 1.82, 95% confidence interval: 1.33, 2.49; P-trend < 0.001) and AAI (AAI </= 0.9 vs. AAI 1.01-1.30: hazard ratio = 1.57, 95% confidence interval: 1.14, 2.18) predicted CHD events above traditional risk factors and modestly improved global measures of predictive accuracy. CRP, TNF-alpha, and aPWV had weaker associations. IL-6 and AAI accurately reclassified 6.6% and 3.3% of participants, respectively (P's </= 0.05). Results were similar for "hard" CHD, with higher reclassification rates for AAI. IL-6 and AAI are associated with future CHD events beyond traditional risk factors and modestly improve risk prediction in older adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study evaluates sealing characteristics of two designs of endovascular grafts by angiographic demonstration of exclusion of porcine lumbar arteries. METHODS: 6 endovascular grafts (3 self-expandable with integrated polyurethane wall versus 3 nitinol structures covered with polyester fabric) were implanted in 6 porcine aortae. Perfusion of lumbar arteries was assessed by angiography after implantation and by angiography and dissection at graft explantation after 4 +/- 2 months. Tissue healing was evaluated by light and scanning electron microscopy. RESULTS: Immediate exclusion of the lumbar arteries was achieved in 14/31 vessels (12 by polyurethane grafts and 2 by polyester grafts, p < 0.001). Follow-up angiography and dissection at explantation revealed perfusion of 30/31 lumbar arteries with a collateral network in most cases. Another reason for reperfusion of initially excluded branches was distention of the polyurethane grafts with resulting shortening allowing reperfusion of 8 of the 31 originally covered branches. Histological examination revealed a complete neointimal lining and a tight contact between endovascular grafts and aorta. CONCLUSIONS: The immediate angiographic demonstration of exclusion of lumbar arteries predicts sealing characteristics of endovascular grafts. Later angiographic reappearance is due to development of a collateral network and possible shortening of self-expandable devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the utility of inversion recovery with on-resonant water suppression (IRON) in combination with injection of the long-circulating monocrystalline iron oxide nanoparticle (MION)-47 for contrast material-enhanced magnetic resonance (MR) angiography. MATERIALS AND METhods: Experiments were approved by the institutional animal care committee. Eleven rabbits were imaged at baseline before injection of a contrast agent and then serially 5-30 minutes, 2 hours, 1 day, and 3 days after a single intravenous bolus injection of 80 micromol of MION-47 per kilogram of body weight (n = 6) or 250 micromol/kg MION-47 (n = 5). Conventional T1-weighted MR angiography and IRON MR angiography were performed on a clinical 3.0-T imager. Signal-to-noise and contrast-to-noise ratios were measured in the aorta of rabbits in vivo. Venous blood was obtained from the rabbits before and after MION-47 injection for use in phantom studies. RESULTS: In vitro blood that contained MION-47 appeared signal attenuated on T1-weighted angiograms, while characteristic signal-enhanced dipolar fields were observed on IRON angiograms. In vivo, the vessel lumen was signal attenuated on T1-weighted MR angiograms after MION-47 injection, while IRON supported high intravascular contrast by simultaneously providing positive signal within the vessels and suppressing background tissue (mean contrast-to-noise ratio, 61.9 +/- 12.4 [standard deviation] after injection vs 1.1 +/- 0.4 at baseline, P < .001). Contrast-to-noise ratio was higher on IRON MR angiograms than on conventional T1-weighted MR angiograms (9.0 +/- 2.5, P < .001 vs IRON MR angiography) and persisted up to 24 hours after MION-47 injection (76.2 +/- 15.9, P < .001 vs baseline). CONCLUSION: IRON MR angiography in conjunction with superparamagnetic nanoparticle administration provides high intravascular contrast over a long time and without the need for image subtraction.