878 resultados para Condition Monitoring, Asset Management, Maintenance, Low Speed Machinery, Diagnostics


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis presents a low cost non-intrusive home energy monitor built on top of Non-Intrusive Load Monitoring (NILM) concepts and techniques. NILM solutions are already considered low cost alternatives to the big majority of existing commercial energy monitors but the goal here is to make its cost even lower by using a mini netbook as a whole in one solution. The mini netbook is installed in the homes main circuit breaker and computes power consumption by reading current and voltage from the built-in sound card. At the same time, feedback to the users is provided using the 11’’ LCD screen as well as other built-in I/O modules. Our meter is also capable of detecting changes in power and tries to find out which appliance lead to that change and it is being used as part of an eco-feedback platform that was build to study the long terms of energy eco-feedback in individuals. In this thesis the steps that were taken to come up with such a system are presented, from the basics of AC power measurements to the implementation of an event detector and classifier that was used to disaggregate the power load. In the last chapter results from some validation tests that have been performed are presented in order to validate the experiment. It is believed that such a system will not only be important as an energy monitor, but also as an open system than can be easily changed to accommodate and test new or existing nonintrusive load monitoring techniques.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Apesar da importância na dinâmica dos ecossistemas aquáticos, as macrófitas podem formar densas e extensas colonizações em corpos hídricos cujos equilíbrios ecológicos foram rompidos. Nessas condições, essas plantas promovem uma série de problemas que as tornam alvos de controle. Para elaboração de planos adequados de manejo dessa vegetação, é fundamental o conhecimento das dinâmicas relativas das populações que a compõem. O objetivo deste trabalho foi realizar levantamentos mensais da composição específica da comunidade de macrófitas que coloniza o reservatório de Santana, localizado no município de Piraí/RJ, monitorando 97 pontos georreferenciados, abrangendo toda a lâmina d'água. Foram identificadas 41 espécies, inseridas em 21 famílias botânicas. As famílias Poaceae, Pontederiaceae e Cyperacae foram as que apresentaram os maiores números de espécies ao longo do ano. Salvinia herzogii e Egeria densa apresentaram as maiores notas anuais de colonização do reservatório. As populações de Eichhornia azurea, Brachiaria arrecta e Paspalum repens completaram o grupo das espécies numericamente mais relevantes. As plantas de hábito flutuante tenderam a apresentar populações com padrão de distribuição geográfica casualizado, enquanto as espécies fixadas no sedimento e as submersas apresentaram populações com padrão agregado. Não houve expressivas variações mensais dos valores dos índices de diversidade (H') e de equitabilidade (E') das comunidades de macrófitas aquáticas ao longo do ano. O dendrograma construído com o coeficiente de Odum mostrou uma seqüência lógica dos meses, evidenciando uma definida sucessão de populações divididas em dois grupos de similaridade separados pelo mês de junho. Nessa época, o nível de água do reservatório foi reduzido e o sedimento ficou exposto, favorecendo as espécies de hábito emergente.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Este artigo apresenta os principais resultados e o detalhamento da metodologia e equações de controle de um retificador monofásico pré-regulador de 150kW para sistema trólebus. A estrutura proposta possibilita a Correção ativa do Fator de Potência (CFP) com baixos níveis de Distorção Harmônica Total (DHT) na corrente, em conformidade com a norma internacional IEC 61000-3-4. Fruto de um projeto de Pesquisa, Desenvolvimento e Inovação (P) junto à empresa AES Eletropaulo Metropolitana de São Paulo, em parceria com a empresa de transporte Himalaia S.A., o projeto possui como principais objetivos estimular o interesse para a expansão das linhas de trólebus a partir de uma plataforma de alimentação de menor custo de instalação e manutenção, sem a necessidade de subestações retificadoras, e, com vistas a promover a melhoria da qualidade de vida nos grandes centros urbanos. Nessa nova modalidade proposta para o sistema de alimentação, o trólebus pode ser alimentado tanto pelas redes convencionais em corrente contínua (CC) quanto pelas redes de distribuição em corrente alternada (CA), mantendo-se a disposição a dois fios dos sistemas CC, sendo as mudanças de rede de alimentação (CC ou CA) monitoradas e controladas digitalmente. Todo o sistema de gerenciamento e controle do conversor é realizado digitalmente por FPGA XC3S200. Na evolução do sistema proposto, os autores pretendem inclusive eliminar as linhas aéreas de alimentação, através da utilização de postos de alimentação em CA, especialmente desenvolvidos para os pontos de embarque/desembarque de passageiros para este veículo de transporte coletivo, eliminando-se os aspectos visuais negativos das redes de alimentação deste modal, e, reduzindo-se as falhas de operação do sistema.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Bolted joints are a form of mechanical coupling largely used in machinery due to their reliability and low cost. Failure of bolted joints can lead to catastrophic events, such as leaking, train derailments, aircraft crashes, etc. Most of these failures occur due to the reduction of the pre-load, induced by mechanical vibration or human errors in the assembly or maintenance process. This article investigates the application of shape memory alloy (SMA) washers as an actuator to increase the pre-load on loosened bolted joints. The application of SMA washer follows a structural health monitoring procedure to identify a damage (reduction in pre-load) occurrence. In this article, a thermo-mechanical model is presented to predict the final pre-load achieved using this kind of actuator, based on the heat input and SMA washer dimension. This model extends and improves on the previous model of Ghorashi and Inman [2004, "Shape Memory Alloy in Tension and Compression and its Application as Clamping Force Actuator in a Bolted Joint: Part 2 - Modeling," J. Intell. Mater. Syst. Struct., 15:589-600], by eliminating the pre-load term related to nut turning making the system more practical. This complete model is a powerful but complex tool to be used by designers. A novel modeling approach for self-healing bolted joints based on curve fitting of experimental data is presented. The article concludes with an experimental application that leads to a change in joint assembly to increase the system reliability, by removing the ceramic washer component. Further research topics are also suggested.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We compared the fish assemblage structure from streams with different intensities of physical habitat degradation and chemical water pollution by domestic sewage in southeastern Brazil. Eight streams (R1-R8) showing less disturbed or more disturbed conditions of chemical water quality and of physical habitat quality were selected. Cumulative abundance and biomass, combined in ABC plots, revealed (i) biomass curves above the abundance curves, represented by the streams R1-R2 (water and habitat less disturbed) and R5-R6 (water more disturbed and habitat less disturbed), and (ii) biomass curves below the abundance curves, represented by the streams R3-R4 (water less disturbed and habitat more disturbed) and R7-R8 (water and habitat more disturbed). The quantitative structure of the ichthyofauna showed significant correspondence with physical habitat condition but not with chemical water quality. The most significant species to cause the dissimilarity between less disturbed and more disturbed physical habitats was the exotic Poecilia reticulata. Such results indicate that in the focused region-with little influence of industrial pollution, noncritical domestic sewage discharge, and soil predominantly used for pasture-streams with high physical habitat integrity possess a differently structured ichthyofauna than streams with relatively low physical habitat integrity, reinforcing the importance of the physical habitat quality and riparian conservation along these water courses, warranting the conservation of these systems. Indeed, our results also reinforce the importance of including biotic descriptors, particularly of the ichthyo-fauna, in water-monitoring programs designed to reveal signs of human interference.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Quartz Crystal Microbalance (QCM) was used to monitor the mass changes on a quartz crystal surface containing immobilized lectins that interacted with carbohydrates. The strategy for lectin immobilization was developed on the basis of a multilayer system composed of Au-cystamine-glutaraldehyde-lectin. Each step of the immobilization procedure was confirmed by FTIR analysis. The system was used to study the interactions of Concanavalin A (ConA) with maltose and Jacalin with Fetuin. The real-time binding of different concentrations of carbohydrate to the immobilized lectin was monitored by means of QCM measurements and the data obtained allowed for the construction of Langmuir isotherm curves. The association constants determined for the specific interactions analyzed here were (6.4 +/- 0.2) X 10(4) M-1 for Jacalin-Fetuin and (4.5 +/- 0.1) x 10(2) M-1 for ConA-maltose. These results indicate that the QCM constitutes a suitable method for the analysis of lectin-carbohydrate interactions, even when assaying low molecular mass ligands such as disaccharides. Published by Elsevier B.V.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJETIVO: investigar a pré-fragilidade e os fatores associados a essa condição, considerando as medidas de velocidade da marcha dos idosos. MÉTODO: a seleção dos participantes ocorreu por meio de critérios de inclusão/exclusão e teste de rastreamento cognitivo. A amostra foi calculada com base na estimativa da proporção populacional e constituída por 195 idosos, usuários de uma Unidade Básica de Saúde de Curitiba, PR. Os dados foram coletados mediante questionário sociodemográfico/clínico e teste de velocidade da marcha. RESULTADOS: a pré-fragilidade para velocidade da marcha possui moderada prevalência (27,3%) e associou-se à faixa etária entre 60 e 69 anos, baixa escolaridade, não se sentir solitário, utilizar anti-hipertensivo, apresentar doença cardiovascular e sobrepeso. CONCLUSÃO: considera-se relevante identificar os idosos na condição de pré-fragilidade, pois, dessa maneira, existe a possibilidade de intervenção imediata com a finalidade de estacionamento do quadro. É significativo o déficit de estudos sobre a síndrome da fragilidade em idosos brasileiros, principalmente aqueles que se referem a um componente isolado. Visto que a enfermagem gerontológica se encontra nos primeiros passos referentes à temática, entende-se que a identificação da prevalência deve ser o ponto primordial das pesquisas sobre o tema.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Ferralsols have high structural stability, although structural degradation has been observed to result from forest to tillage or pasture conversion. An experimental series of forest skidder passes in an east Amazonian natural forest was performed for testing the effects of mechanical stress during selective logging operations on a clay-rich Ferralsol under both dry and wet soil conditions. Distinct ruts formed up to 25 cm depth only under wet conditions. After nine passes the initially very low surface bulk density of between 0.69 and 0.80 g cm(-3) increased to 1.05 g cm(-3) in the wet soil and 0.92 g cm(-3) in the dry soil. Saturated hydraulic conductivities, initially > 250 mm h(-1), declined to a minimum of around 10 mm h(-1) in the wet soil after the first pass, and in the dry soil more gradually after nine passes. The contrasting response of bulk density and saturated hydraulic conductivity is explained by exposure of subsoil material at the base of the ruts where macrostructure rapidly deteriorated under wet conditions. We attribute the resultant moderately high hydraulic conductivities to the formation of stable microaggregates with fine sand to coarse silt textures. We conclude that the topsoil macrostructure of Ferralsols is subject to similar deterioration to that of Luvisols in temperate zones. The stable microstructure prevents marked compaction and decrease in hydraulic conductivity under wetter and more plastic soil conditions. However, typical tropical storms may regularly exceed the infiltration capacity of the deformed soils. In the deeper ruts water may concentrate and cause surface run-off, even in gently sloping areas. To avoid soil erosion, logging operations in sloping areas should therefore be restricted to dry soil conditions when rut formation is minimal.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a study on the influence of milling condition on workpiece surface integrity focusing on hardness and roughness. The experimental work was carried out on a CNC machining center considering roughing and finishing operations. A 25 mm diameter endmill with two cemented carbide inserts coated with TiN layer were used for end milling operation. Low carbon alloyed steel Cr-Mo forged at 1200 degrees C was used as workpiece on the tests. Two kinds of workpiece conditions were considered, i.e. cur cooled after hot forging and normalized at 950 degrees C for 2 h. The results showed that finishing operation was able to significantly decrease the roughness by at least 46% without changing the hardness. on the other hand, roughing operation caused an increase in hardness statistically significant by about 6%. The machined surface presented deformed regions within feed marks, which directly affected the roughness. Surface finish behavior seems to correlate to the chip ratio given the decrease of 25% for roughing condition, which damaged the chip formation. The material removal rate for finishing operation 41% greater than roughing condition demonstrated to be favorable to the heat dissipation and minimized the effect on material hardness.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The computational program called GIS_EM (Geographic Information System for Environmental Monitoring), a software devised to manage geographic information for monitoring soil, surface, and ground water, developed for use in the Health, Safety, and Environment Division of Paulinia Refinery is presented. This program enables registering and management of alphanumeric information pertaining to specific themes such as drilling performed for sample collection and for installation of monitoring wells, geophysical and other tests, results of chemical analyses of soil, surface, and groundwater, as well as reference values providing orientation for soil and water quality, such as EPA, Dutch List, etc. Management of such themes is performed by means of alphanumeric search tools, with specific filters and, in the case of spatial search, through the selection of spatial elements (themes) in map view. Documents existing in digital form, such as reports, photos, maps, may be registered and managed in the network environment. As the system centralizes information generated upon environmental investigations, it expedites access to and search of documents produced and stored in the network environment, minimizing search time and the need to file printed documents. This is an abstract of a paper presented at the AIChE Annual Meeting and Fall Showcase (Cincinnati, OH 10/30/2005-11/4/2005).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paperwork presents a Pulse Width Modulation (PWM) speed controller for an electric mini-baja-type car. A battery-fed 1-kW three-phase induction motor provides the electric vehicle traction. The open-loop speed control is implemented with an equal voltage/frequency ratio, in order to maintain a constant amount of torque on all velocities. The PWM is implemented by a low-cost 8-bit microcontroller provided with optimized ROM charts for distinct speed value implementations, synchronized transition between different charts and reduced odd harmonics generation. This technique was implemented using a single passenger mini-baja vehicle, and the essays have shown that its application resulted on reduced current consumption, besides eliminating mechanical parts. Copyright © 2007 by ABCM.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper is based on the analysis and implementation of a new drive system applied to refrigeration systems, complying with the restrictions imposed by the IEC standards (Harmonic/Flicker/EMI-Electromagnetic Interference restrictions), in order to obtain high efficiency, high power factor, reduced harmonic distortion in the input current and reduced electromagnetic interference, with excellent performance in temperature control of a refrigeration prototype system (automatic control, precision and high dynamic response). The proposal is replace the single-phase motor by a three-phase motor, in the conventional refrigeration system. In this way, a proper control technique can be applied, using a closed-loop (feedback control), that will allow an accurate adjustment of the desirable temperature. The proposed refrigeration prototype uses a 0.5Hp three-phase motor and an open (Belt-Drive) Bitzer IY type compressor. The input rectifier stage's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output three-phase inverter stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at the refrigerator prototype. ©2008 IEEE.