956 resultados para Complete denture - Disinfection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the change in masticatory efficiency and quality of life of patients treated with mandibular Kennedy class I removable partial dentures (RPDs) and maxillary complete dentures at the Department of Dentistry of the Federal University of Rio Grande do Norte. A total of 33 Kennedy class I patients were rehabilitated with maxillary complete dentures, and mandibular RPDs were selected for this non-randomized prospective intervention study. The patients had a mean age of 59.1 years. Masticatory efficiency was evaluated by colorimetric assay using fuchsin capsules. The measurements were conducted at baseline and 2 and 6 months after prosthesis insertion. Quality of life was evaluated using the Oral Health Impact Profile (OHIP-14) at baseline and 6 months after denture insertion. The Kolmogorov-Smirnov normality test was applied. Masticatory efficiency was evaluated by repeated measures ANOVA. Oral health-related quality of life was compared using the paired t test. There was no statistically significant difference in masticatory efficiency after denture insertion (p = 0.101). Significant differences were found (p = 0.010) for oral health-related quality of life. A significant improvement in psychological discomfort (p < 0.01) and psychological disability (p < 0.01) was observed. Mean difference value (95 % confidence interval) was 6.8 (3.8 to 9.7) points, reflecting a low impact of oral health on quality of life, considering the 0-56 range of variation of the OHIP-14 and a Cohen's d of 1.13. According to the results of the present study, rehabilitation with Kennedy class I RPDs and complete dentures did not influence masticatory efficiency but improved oral health-related quality of life. The association between the patient's quality of life and the masticatory efficiency is important for treatment predictability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To re-evaluate the safety of hormonal contraceptives (HC) after uterine evacuation of complete hydatidiform mole (CHM). Historical database review. Charing Cross Hospital Gestational Trophoblastic Disease Centre, London, United Kingdom. Two thousand four hundred and twenty-three women with CHM of whom 154 commenced HC while their human chorionic gonadotropin (hCG) was still elevated, followed between 2003 and 2012. We compared time to hCG remission between HC users and nonusers. The relationship between HC use and gestational trophoblastic neoplasia (GTN) development was assessed. The relationship between HC use and a high International Federation of Gynecology and Obstetrics (FIGO) risk score was determined. Time to hCG remission, risk of developing postmolar GTN and proportion of women with high FIGO risk score. No relationship was observed between HC use with mean time to hCG remission (HC users versus non-users: 12 weeks in both, P = 0.19), GTN development (HC users versus non-users: 20.1 and 16.7%, P = 0.26) or high-risk FIGO score (HC users versus nonusers: 0% and 8%, P = 0.15). Moreover, no association between HC and GTN development was found, even when an age-adjusted model was used (OR = 1.37, 95% CI 0.91-2.08, P = 0.13). The use of current HC is not associated with development of postmolar GTN or delayed time to hCG remission. Therefore, HC can be safely used to prevent a new conception following CHM regardless of hCG level. Non-concurrent cohort study to re-evaluate the safety of low dose HCs after uterine evacuation of CHM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the bond strength between two types of acrylic resin teeth and a microwave denture base resin after immersion in disinfectant solutions for 180 days. Eighty specimens made of acrylic resin teeth (Biotone and Biotone IPN) attached to a microwave polymerized denture base resin (Nature-Cryl MC) were divided into eight groups (n = 10) according to the treatment (distilled water-control, 2% chlorhexidine digluconate, 1% sodium hypochlorite and sodium perborate solution-Corega Tabs). The shear strength tests (MPa) were carried out using a universal testing machine with a 0.5 mm/min speed. Data analysis was performed using ANOVA and multiple comparison Student-Newman-Keuls post hoc test (α = 0.05). Biotone IPN showed similar results among the groups (distilled water, 8.25 ± 1.81 MPa; chlorhexidine, 7.81 ± 3.34 MPa; hypochlorite, 7.75 ± 3.72 MPa; and Corega Tabs, 7.58 ± 2.27 MPa, whereas Biotone showed significantly lower shear bond strength values for the groups immersed in Corega Tabs (5.25 ± 3.27 MPa) and chlorhexidine (6.08 ± 2.35 MPa). Soaking the dentures in 1% sodium hypochlorite could be recommended as a disinfectant solution for dentures fabricated with conventional acrylic resin denture teeth and microwave denture base resin. For dentures fabricated with IPN teeth and microwave denture base resin, all the soaking solutions evaluated in this study could be suggested to denture wearers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alveolar wall fenestrations are common during implant placement. The aim of this paper is to report a case where a peri-implant bone fenestration was reconstructed immediately after implant placement by an autogenous mandibular bone block. A male patient was referred to the Department of Surgical and Integrated Clinics to substitute his Kennedy´s Class IV removable partial denture for an implantsupported fixed prosthesis. A peri-implant bone fenestration at the buccal wall was seen at the region of 12, being reconstructed by a mandibular bone block secured by a bicortical screw. Six months later the surgical procedures, an implant-supported complete fixed partial prosthesis was developed. The autogenous bone block harvested from the mandibular ramus was a safe alternative to reconstruct the peri-implant bone defect such as fenestration types.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Risk of mechanical injuries contraindicate brushing and elect chemical agents as appropriate for daily cleaning of dentures relined with resilient materials. It was evaluated the effect of denture cleansers on the wettability of denture relining material (Dentusoft, Dental Medrano). We used 20 discs of acrylic resin thermoactivated VipiCril ® with 30mm diameter and 4mm thick, covered by 2mm Dentusoft ®. Divided into 4grupos were stored in artificial saliva at 37 +1 º C for 30 days, immersed daily for 15minutes in distilled water (GI), Corega ® Tabs (GII), a solution of sodium bicarbonate (GIII) or solution of sodium hypochlorite (GIV) after which, on the soft liner were poured 2 ml of type IV gypsum (Durone IV, Dentsply). Reached the final setting of the gypsum specimens were sectioned vertically and medially, settled water with sandpaper No. 400 and mounted on suitable device for reading (in the right and left) of the contact angle Carl Zeiss microscope (precision, 001). The results were submitted to analysis, showed non-normal distribution, opting for non-parametric test. Kruskal Wallis test performed at 5% significance, there was statistical difference between the groups with lower average contact angle for GII. It was concluded that the chemical cleaning Corega Tabs ® allowed a better adaptation of relining the gypsum studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dissatisfaction of the treatment with mandibular complete dentures in edentulous patients has been a constant problem in Dentistry. Often, the absence of stability and retention, resultants of a physiologic condition and alveolar ridge resorption, bring reduction of chewing force, speech problems and social life interference. In these cases, the rehabilitation over osseointegrated implants can be an effective and safe alternative of treatment. When it is not possible to put implants in appropriate number and disposition, it is necessary to make a simple and low costing prosthetic planning, which makes resurge the overdentures. Various implant supported attachment systems for overdentures have been developed in the dental market. Thus, intending to facilitate the professional choice, this study review the literature about attachment systems O’ring and bar- clip in its following aspect: retention level, stress distribution, hygiene complications and patient satisfaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The population’s life expectancy is growing every year. This fact highlights the importance of the elderly for the dentistry. The oral cavity quality has great influence on quality of life at both the biological and the psychological and social factors by maintaining a self-esteem, self-expression, communication and satisfactory facial aesthetics. Unfortunately, the number of edentulous elderly population is also high, which may create problems to their social life. Therefore, the objective of this study was to demonstrate and evaluate the difficulties of treating edentulous patients, comparing data prior to treatment to post data after treatment by complete dentures made to the patients undergoing oral rehabilitation in the Dental Clinic of the Faculty of Dentistry of Adamantina – FAI. For this study, questionnaires were filled in the form of answers developed alternative focused on the degree of patient satisfaction, the current situation of occlusion, and outcome of treatment. The results showed that 96% of patients were satisfied with the results obtained in the treatment, all of whom believed that the prosthesis helped them feel better aesthetically and improved self-esteem. By this methodology, it was concluded that the degree of satisfaction was high, but the services provided must be constantly reevaluated, once the elderly population presents a wide labor market for dental professionals and demand level services will certainly increase each year.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: In order to assist in the selection of artificial teeth for complete dentures, this study aimed to assess the relationship between horizontal and vertical measurements of the face and the morphology of the maxillary central incisor. Materials and Methods: This was a study of 50 plaster casts and 100 teleradiographs - 50 in lateral norm and 50 in frontal norm, belonging to 50 individuals, Caucasian, with a naturally optimal occlusion, matching at least four of the six keys of Andrews. Images of the upper central incisors were obtained by scanning the plaster casts (three-dimensional) and subjectively classified by three examiners as oval, triangular or quadrangular. Facial measures (vertical and horizontal) were defined by means of teleradiographs. In order to check inter-examiner agreement on the classification of central incisor, the Kappa test was used. To verify whether data had normal distribution, the Kolmogorov-Smirnov test was used ( P > 0.2) was used. One-way analysis of variance was employed to assess the association between variables (P > 0.05). Results: When vertical measurements were compared with the three incisor shapes, there was no statistically significant difference (P > 0.05): Triangular (0.54), oval (0.63) and quadrangular (0.51). Similarly, no difference (P > 0.05) was found for facial width (139.08, 143.37, 141.65), maxillary width (76.68, 78.99, 76.91) and mandibular width (103.47, 105.50, 103.11). Conclusions: The majority of cases showed that horizontal and vertical measurements of the face cannot be used as a reference for determining the morphology of the maxillary central incisor crown. It is relevant to analyze and compare other morphological structures to improve the oral health-related quality of life for the conventional denture wearer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The failure of facial prostheses is caused by limitations in the properties of existing materials, especially flexibility and durability. Therefore, this study evaluated the marginal deterioration of a silicone used for fabrication of facial prostheses (Silastic MDX4-4210, Dow Corning Corporation, Midland, MI, USA) according to the influence of artificial aging, daily disinfection, and 2 types of pigmentation. Thirty specimens were fabricated and subdivided in 6 groups: without pigmentation, pigmented with make-up powder and iron oxide, and evaluated with and without the action of the disinfectant. Analysis of marginal deterioration was performed on a scanning electron microscope (magnification, ×5000) immediately 6 months and 1 year after fabrication of specimens, following the guidelines of ASTM International. After visual analysis of the photomicrographs, it was noticed that all groups presented marginal deterioration and alterations in surface texture with time. The use of disinfection did not contribute to the marginal deterioration of polymer (silicone), regardless of the pigmentation and artificial aging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Considering the limited qualitative and quantitative bone in the posterior arch, this modality of prosthetic treatment could provide a positive emotional factor reestablished by immovability of the anterior fixed implant-supported segment. Objective: This clinical report demonstrates the possibility of achieving positive results with a removable partial denture connected to an implant-supported fixed prosthesis associated to an extra resilient attachment. Clinical significance: In cases of posterior mandibular and maxilla atrophy added to the patients desire against the bone graft, this kind of prosthetic treatment has an important place as an alternative.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The alveolar ridge shape plays an important role in predicting the demand on the support tooth and alveolar bone in the removable partial denture (RPD) treatment. However, these data are unclear when the RPD is associated with implants. This study evaluated the influence of the alveolar ridge shape on the stress distribution of a free-end saddle RPD partially supported by implant using 2-dimensioanl finite element analysis (FEA). Four mathematical models (M) of a mandibular hemiarch simulating various alveolar ridge shapes (1-distal desceding, 2- concave, 3-horizontal and 4-distal ascending) were built. Tooth 33 was placed as the abutment. Two RPDs, one supported by tooth and fibromucosa (MB) and other one supported by tooth and implant (MC) were simulated. MA was the control (no RPD). The load (50N) were applied simultaneously on each cusp. Appropriate boundary conditions were assigned on the border of alveolar bone. Ansys 10.0 software was used to calculate the stress fields and the von Mises equivalent stress criteria (σvM) was applied to analyze the results. The distal ascending shape showed the highest σvM for cortical and medullar bone. The alveolar ridge shape had little effect on changing the σvM based on the same prosthesis, mainly around the abutment tooth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Let (R,m) be a local complete intersection, that is, a local ring whose m-adic completion is the quotient of a complete regular local ring by a regular sequence. Let M and N be finitely generated R-modules. This dissertation concerns the vanishing of Tor(M, N) and Ext(M, N). In this context, M satisfies Serre's condition (S_{n}) if and only if M is an nth syzygy. The complexity of M is the least nonnegative integer r such that the nth Betti number of M is bounded by a polynomial of degree r-1 for all sufficiently large n. We use this notion of Serre's condition and complexity to study the vanishing of Tor_{i}(M, N). In particular, building on results of C. Huneke, D. Jorgensen and R. Wiegand [32], and H. Dao [21], we obtain new results showing that good depth properties on the R-modules M, N and MtensorN force the vanishing of Tor_{i}(M, N) for all i>0. We give examples showing that our results are sharp. We also show that if R is a one-dimensional domain and M and MtensorHom(M,R) are torsion-free, then M is free if and only if M has complexity at most one. If R is a hypersurface and Ext^{i}(M, N) has finite length for all i>>0, then the Herbrand difference [18] is defined as length(Ext^{2n}(M, N))-(Ext^{2n-1}(M, N)) for some (equivalently, every) sufficiently large integer n. In joint work with Hailong Dao, we generalize and study the Herbrand difference. Using the Grothendieck group of finitely generated R-modules, we also examined the number of consecutive vanishing of Ext^{i}(M, N) needed to ensure that Ext^{i}(M, N) = 0 for all i>>0. Our results recover and improve on most of the known bounds in the literature, especially when R has dimension two.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fogging of ReJeX-iT7 TP-40 offers a very efficient method for the control and dispersal of nuisance birds from many diverse areas. The amount of the repellent is greatly reduced over any other control method. The method is direct and is independent of the activity of the birds. The applications with any fogger, thermal or mechanical, that can deliver droplets of less than 20 microns, can be manually or fully automated and pose only minimal risks to operators or animals. All birds that became a nuisance and safety problem in the hangars of TWA and AA at LaGuardia, and TWA warehouse at Newark Airport were successfully driven out by fogging ReJeX-iT7 TP-40 with a Curtis Dyna-Fog AGolden Eagle@ thermal fogger.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this prospective study was to verify the changes in the preoperative and postoperative complete blood counts of patients with surgically treated facial fractures. Fifty consecutive patients with a mean age of 34 years who presented facial fractures and underwent surgical treatment were included. A complete blood count was performed, comprising the red and white blood cell count (cells/mu L), hemoglobin (g/dL), and hematocrit (%) levels. These data were obtained preoperatively and postoperatively during a 6-week period. Statistical analyses were performed using the Kruskal-Wallis and Mann-Whitney tests to identify the possible differences among the groups and among the periods of observation using the Friedman and Wilcoxon matched-pairs signed-ranks tests. The most common location of the fractures was the mandible (42.3%), followed by the zygomatic-orbital (36.5%) and associated locations (21.2%). Leukocytosis was associated with neutrophilia in the immediate postoperative period in all of the groups. There were no values below the reference limits of the values of hemoglobin, hematocrit, and erythrocytes, and no values above the reference limits for the remaining white blood cells, although significant differences among periods were observed in most cells, depending on the type of fracture. The primary findings were leukocytosis associated with neutrophilia, verified in the immediate postoperative period in all of the groups, and the influence of the type of fracture on the significant alterations observed among studied periods on the values of hemoglobin, hematocrit, erythrocytes, leukocytes, neutrophils, and lymphocytes.