996 resultados para Colorimetric sensor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ocean Virtual Laboratory is an ESA-funded project to prototype the concept of a single point of access for all satellite remote-sensing data with ancillary model output and in situ measurements for a given region. The idea is to provide easy access for the non-specialist to both data and state-of-the-art processing techniques and enable their easy analysis and display. The project, led by OceanDataLab, is being trialled in the region of the Agulhas Current, as it contains signals of strong contrast (due to very energetic upper ocean dynamics) and special SAR data acquisitions have been recorded there. The project also encourages the take up of Earth Observation data by developing training material to help those not in large scientific or governmental organizations make the best use of what data are available. The website for access is: http://ovl-project.oceandatalab.com/

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermocouples are one of the most popular devices for temperature measurement due to their robustness, ease of manufacture and installation, and low cost. However, when used in certain harsh environments, for example, in combustion systems and engine exhausts, large wire diameters are required, and consequently the measurement bandwidth is reduced. This article discusses a software compensation technique to address the loss of high frequency fluctuations based on measurements from two thermocouples. In particular, a difference equation sDEd approach is proposed and compared with existing methods both in simulation and on experimental test rig data with constant flow velocity. It is found that the DE algorithm, combined with the use of generalized total least squares for parameter identification, provides better performance in terms of time constant estimation without any a priori assumption on the time constant ratios of the thermocouples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is standard clinical practice to use a combination of two or more antimicrobial agents to treat an infection caused by Pseudonionas aeruginosa. The antibiotic combinations are usually selected empirically with methods to determine the antimicrobial effect of the combination such as the time-kill assay rarely used as they are time-consuming and labour intensive to perforin. Here, we report a modified time-kill assay, based on the reduction of the tetrazolium salt, 2,3-bis[2-methyloxy-4-nitro-5-sulfopheny1]-2H-tetrazolium-5-carboxanilide (XTT), that allows simple, inexpensive and more rapid determination of the in vitro activity of antibiotic combinations against P aeruginosa. The assay was used to determine the in vitro activity of ceftazidime and tobramycin in combination against P. aertiginosa isolates from cystic fibrosis patients and the results obtained compared with those from conventional viable count time-kill assays. There was good agreement in interpretation of results obtained by the XTT and conventional viable count assays, with similar growth curves apparent and the most effective concentration combinations determined by both methods identical for all isolates tested. The XTT assay clearly indicated whether an antibiotic combination had a synergistic, indifferent or antagonistic effect and could, therefore, provide a useful method for rapidly determining the activity of a large number of antibiotic combinations against clinical isolates. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermocouples are one of the most popular devices for temperature measurement due to their robustness, ease of manufacture and installation, and low cost. However, when used in the harsh environment found in combustion systems and automotive engine exhausts, large wire diameters are required and consequently the measurement bandwidth is reduced. This paper describes two new algorithmic compensation techniques based on blind deconvolution to address this loss of high-frequency signal components using the measurements from two thermocouples. In particular, a continuous-time approach is proposed, combined with a cross-relation blind deconvolution for parameter estimation. A feature of this approach is that no a priori assumption is made about the time constant ratio of the two thermocouples. The advantages, including small estimation variance and limitations of the method, are highlighted using results from simulation and test rig studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characterization of thermocouple sensors for temperature measurement in varying-flow environments is a challenging problem. Recently, the authors introduced novel difference-equation-based algorithms that allow in situ characterization of temperature measurement probes consisting of two-thermocouple sensors with differing time constants. In particular, a linear least squares (LS) lambda formulation of the characterization problem, which yields unbiased estimates when identified using generalized total LS, was introduced. These algorithms assume that time constants do not change during operation and are, therefore, appropriate for temperature measurement in homogenous constant-velocity liquid or gas flows. This paper develops an alternative ß-formulation of the characterization problem that has the major advantage of allowing exploitation of a priori knowledge of the ratio of the sensor time constants, thereby facilitating the implementation of computationally efficient algorithms that are less sensitive to measurement noise. A number of variants of the ß-formulation are developed, and appropriate unbiased estimators are identified. Monte Carlo simulation results are used to support the analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mach-Zehnder and Michelson interferometers using core-offset attenuators were demonstrated. As the relative offset direction of the two attenuators in the Mach-Zehnder interferometer can significantly affect the extinction ratio of the interference pattern, single core-offset attenuator-based sensors appear more robust and repeatable. A novel fiber Michelson interferometer refractive index (RI) sensor was subsequently realized by a single core-offset attenuator and a layer of ~ 500-nm gold coating. The device had a minimum insertion loss of 0.01 dB and maximum extinction ratio over 9 dB. The sensitivity (0.333 nm) of the new sensor to its surrounding RI change (0.01) was found to be comparable to that (0.252 nm) of an identical long period gratings pair Mach-Zehnder interferometric sensor, and its ease of fabrication makes it a low-cost alternative to existing sensing applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Key pre-distribution schemes have been proposed as means to overcome Wireless Sensor Networks constraints such as limited communication and processing power. Two sensor nodes can establish a secure link with some probability based on the information stored in their memories though it is not always possible that two sensor nodes may set up a secure link. In this paper, we propose a new approach that elects trusted common nodes called ”Proxies” which reside on an existing secure path linking two sensor nodes. These sensor nodes are used to send the generated key which will be divided into parts (nuggets) according to the number of elected proxies. Our approach has been assessed against previously developed algorithms and the results show that our algorithm discovers proxies more quickly which are closer to both end nodes, thus producing shorter path lengths. We have also assessed the impact of our algorithm on the average time to establish a secure link when the transmitter and receiver of the sensor nodes are ”ON”. The results show the superiority of our algorithm in this regard. Overall, the proposed algorithm is well suited for Wireless Sensor Networks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new generation of water soluble tetrazolium salts have recently become available and in this study we compared a colorimetric assay developed using one of these salts, 2-(2-methoxy-4-nitrophenyl)-3-(4-nitrophenyl)-5-(2, 4-disulfophenyl)-2H-tetrazolium, monosodium salt (WST-8), with a previously developed 2,3-bis[2-methyloxy-4-nitro-5-sulfophenyl]-2H-tetrazolium-5-carboxanilide(XTT) colorimetric assay to determine which agent is most suitable for use as a colorimetric indicator in susceptibility testing. The MICs of 6 antibiotics were determined for 33 staphylococci using both colorimetric assays and compared with those obtained using the British Society for Antimicrobial Chemotherapy reference broth microdilution method. Absolute categorical agreement between the reference and test methods ranged from 79% (cefuroxime) to 100% (vancomycin) for both assays. No minor or major errors occurred using either assay with very major errors ranging from zero (vancomycin) to seven (cefuroxime). Analysis of the distribution of differences in the 1092 dilution MIC results revealed overall agreement, within the accuracy limits of the standard test ( 1 1092 dilution), using the XTT and WST-8 assays of 98% and 88%, respectively. Further studies on 31 ESBL-producing isolates were performed using the XTT method with absolute categorical agreement ranging from 87% (nitrofurantoin) to 100% (ofloxacin and meropenem). No errors were noted for either ofloxacin or meropenem with overall agreement of 91%. The data suggests that XTT is more reliable and accurate than WST-8 for use in a rapid antimicrobial susceptibility test. (c) 2007 Elsevier B.V. All rights reserved.