924 resultados para Chromatographic fingerprint


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors have studied the chromatographic behavior of parenteral preparations for pediatric use containing inorganic cations. After separation and identification by thin-layer chromatography, Mn2+, Zn2+, and Cu2+ were analyzed by a method based on reaction with an appropriate reagent and extraction with an organic solvent which yielded elution and preconcentration, resulting in an appropriate solution for colorimetric quantitation. Cr3+ cation was determined by atomic absorption spectrophotometry after appropriate chromatographic separation, using microcrystalline cellulose (adsorbent) and an acetone:water:hydrochloric acid mixture (80:5:8) as the mobile phase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cyclic voltammetric behavior of acetaldehyde and the derivatized product with 2,4-dinitrophenylhydrazine (DNPHi) has been studied at a glassy carbon electrode. This study was used to optimize the best experimental conditions for its determination by high-performance liquid chromatographic (HPLC) separation coupled with electrochemical detection. The acetaldehyde-2,4-dinitrophenyl.hydrazone (ADNPH) was eluted and separated by a reversed-phase column, C-18, under isocratic conditions with the mobile phase containing a binary mixture of methanol/LiCl(aq) at a concentration of 1.0 x 10(-3) M (80:20 v/v) and a flow rate of 1.0 mL min(-1). The optimum condition for the electrochemical detection of ADNPH was +1.0 V vs. Ag/AgCl as a reference electrode. The proposed method was simple, rapid (analysis time 7 min) and sensitive (detection limit 3.80 mu g L-1) at a signal-to-noise ratio of 3:1. It was also highly selective and reproducible [standard deviation 8.2% +/- 0.36 (n = 5)]. The analytical curve of ADNPH was linear over the range of 3-300 mg L-1 per injection (20 mu L), and the analytical recovery was > 99%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The best solvent for paprika oleoresin extraction was determined by comparison with a commercial oleoresin. Pigment composition was determined by HPLC. The solvent system hexane/acetone/isopropilic alcohol (3:2:1) shown to be the best for extraction of the oleoresin, giving the best yield and colour value and a chromatographic pattern identical to that of the commercial oleoresin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Silica gel surface was chemically modified with beta-diketoamine groups by reacting the silanol from the silica surface with 3-aminopropyl-triethoxysilane and 3-bromopentanedione, With this material, copper ions were adsorbed from aqueous solutions, the chemical analysis of the silica-gel-immobilized acetylacetone provided a quantity of 0.67 mmol g(-1) of organic groups attached to the support and 0.63 mmol g(-1) of copper, This material was used as a stationary phase in IMAC (immobilized metal affinity chromatography), to separate alpha-lactoalbumin from bovine milk whey, the results showed an efficient separation in the chromatographic column, the possibility of reutilization of the stationary phase was also investigated. (C) 1997 Academic Press

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Turnera diffusa Willd. var. afrodisiaca (Ward) Urb. (syn. T. aphrodisiaca) belongs to the family of Turneraceae and is an aromatic plant growing wild in the subtropical regions of America and Africa. It is widely used in the traditional medicine as e.g. anti-cough, diuretic, and aphrodisiac agent. This work presents a 3 min chromatographic analysis using low-pressure (LP) gas chromatography (GC)-ion-trap (IT) mass spectrometry (MS). The combination of a deactivated 0.6 m x 0.10 mm i.d., restrictor with a wide-bore CP-Wax 52 capillary column (10 m x 0.53 mm i.d., 1 mum) reduces the analysis time by a factor of 3-7 in comparison to the use of a conventional narrow bore column. Chromatographic conditions have been optimized to achieve the fastest separation with the highest signal/noise ratio in MS detection. These results allow fast and reliable quality control of the essential oil to be achieved. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Buffalo erythrocytes contain one isozyme of hexokinase that apparently lacks microheterogeneity as shown by chromatographic properties. A single protein band was detected by means of Western blotting using an antibody raised in rabbits against homogeneous rat brain hexokinase I. The native protein has a molecular weight of 200,000 +/- 2880 by gel filtration. Partial purification of erythrocyte hexokinase by a combination of several procedures, including affinity chromatography, which was previously applied successfully to the purifica tion of other mammalian type I hexokinases, produced a partially purified enzyme that showed several contami nants after SDS-polyacrylamide gel electrophoresis. The affinity of buffalo erythrocyte hexokinase for glucose (K-m = 0.012 +/- 0.001 mM) is lower than most other mammal hexokinases type I. It phosphorylates other sugars, with considerably higher K-m values. This isozyme is able to use MgATP but does not use MgGTP, MgCTP or MgUTP. We used inhibition patterns, obtained with products to elucidate enzyme sequential mechanisms. Our results are clearly in agreement with a random sequential mechanism and in disagreement with an ordered sequential mechanism with either glucose or ATP as the obligatory first substrates. The ADP inhibition was of mixed type with both ATP and glucose as substrates. (C) 1997 Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and efficient method for the simultaneous gas chromatographic determination of ten organochlorine pesticides (alpha-HCH, beta-HCH, gamma-HCH, p,p'-DDT, o,p'-DDT, p,p'-DDD, p,p'-DDE, aldrin, endrin, and dieldrin) and six congeners of PCBs (PCB 28, 52, 118, 138, 153, and 180) in municipal solid waste compost is described. The procedure involves a solid-phase dispersion matrix using celite as dispersant sorbent, alumina as clean up sorbent and hexane-dichloromethane (7:3, v/v) mixture as eluting solvent. An additional purification step with copper was necessary to eliminate sulphur. Analysis of the sample was performed by GC-ECD. The method was validated with fortified samples at two concentration levels (0.025 and 0.05 mg kg(-1)). Average recovery ranged from 77 to 121% with relative standard deviation between 1 and 18%. The detection limits, which ranged from 0.003 to 0.01 mg kg-1, were lower than those established by the Baden-Wurttemberg directive (0.033 mg kg(-1)).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Suspended particles and dissolved substances in water provide reactive surfaces, influence metabolic activity and contribute to the net sediment deposition. It therefore plays an important part in the ecology and quality of the water mass. The water quality in reservoirs is crucial and it is naturally maintained by flushing and sedimentation, which continuously remove phosphorus from the water. In some reservoirs, however, these removal processes are countered by recycling of ions which could play a key role to start and/or maintain the eutrophic state. The combination of macro-, trace- and microanalysis techniques can be useful to trace pollution sources through a chemical fingerprint, whether be during an acute environmental disaster or a long-term release of pollutants. The water quality and total metal content of reservoir sediments were assessed in a reservoir, situated in the capital of the Parana State, in the South-Eastern part of Brazil. The goal of this paper was to determine the metal presence in the sediment and metal and ionic speciation in the Green River reservoir water. Water and bed sediment samples, collected from various sites during 2008 and 2009, were investigated using XRF, ICP-OES, ICP-MS, XRD and zeta potential measurements. Based on the results, the heavy metal concentration and chemical composition of the suspended matter in the water samples, as well as the sediment's chemical composition will be discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)