899 resultados para CALCIUM FLUORIDE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to histopathologically examine the reaction of the connective tissue of rats to 2 calcium hydroxide-based sealers, Acroseal and Sealapex. Dentin tubes containing the materials and empty control tubes were implanted into the dorsal connective tissue of 36 Wistar albino rats. The animals were killed after 7 or 30 days, and the specimens were prepared for histologic analysis with hematoxylin and eosin, Von Kossa technique, and polarized light. Results were statistically analyzed using Kruskal-Wallis test. Both materials caused mild or moderate inflammatory reactions on the 7th day, but these reactions decreased by the 30th day with no significant difference at any time (P > .05). Mineralization of the subcutaneous tissue of the rats was observed only with Sealapex.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose was to evaluate the cytotoxicity of two novel formulations (alpha and beta) of calcium phosphate cements. Positive control, represented by a commercial hydroxyapatite cement, and negative control were included for comparative purposes. A continuous lineage of fibroblastic cells was used, and the effect of the tested materials on both cell proliferation and viability was assessed by counting cell number on hemocytometer and by the trypan blue exclusion test, respectively. Study design attempted to simulate clinical use by allowing direct and indirect contact of cells and cements. Results were analyzed by the Kruskal-Wallis test and indicated that the beta formulation was extremely cytotoxic (P < 0.001), because this material induced the greatest reduction on cell proliferation and viability. The alpha formulation behaved similarly to the positive control regarding its effect on cell proliferation and viability. Thus, it is concluded that alpha formulation has promise for further evaluation of its behavior in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: the purpose of the present study was to evaluate the histologic results of bone cavities that were surgically created in the mandibles of Cebus apella monkeys and filled with autogenous bone, PerioGlas, FillerBone, or Bone Source. Materials and Methods: Surgical cavities 5 mm in diameter were prepared through both mandibular cortices in the mandibular angle region. The cavities were randomly filled, and the animals were divided into groups according to the material employed: Group 1 cavities were filled with autogenous corticocancellous bone; group 2 cavities were filled with calcium phosphate cement (BoneSource); and group 3 and group 4 cavities were filled with bioactive glass (FillerBone and PerioGlas, respectively). After 180 days the animals were sacrificed, and specimens were prepared following routine laboratory procedures for hematoxylin/eosin staining and histologic evaluation. Results: the histologic analysis showed that autogenous bone allowed total repair of the bone defects; bioactive glasses (FillerBone and PerioGlas) allowed total repair of the defects with intimate contact of the remaining granules and newly formed bone; and the cavities filled with calcium phosphate cement (BoneSource) were generally filled by connective fibrous tissue, and the material was almost totally resorbed. Discussion: the autogenous bone, FillerBone, and PerioGlas provided results similar to those in the current literature, showing that autogenous bone is the best Choice for filling critical-size defects. Synthetic implanted materials demonstrated biocompatibility, but the bioglasses demonstrated osteoconductive activity that did not occur with calcium phosphate (BoneSource). Conclusion: According to the methodology used in this study, it can be concluded that the utilization of autogenous bone and bioactive glasses permitted the repair of surgically created critical-size defects by newly formed bone; the synthetic implanted materials demonstrated biocompatibility, and the bioactive glasses demonstrated osteoconductive activity. The PerioGlas was mostly resorbed and replaced by bone and the remaining granules were in close contact with bone; the FillerBone showed many granules in contact with the newly formed bone; BoneSource did not permit repair of the critical-size defects, and the defects were generally filled by connective fibrous tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Prosthetic rehabilitation of the posterior maxilla with dental implants is often difficult because of proximity to the maxillary sinus and insufficient bone height. Maxillary sinus floor augmentation procedures aim to obtain enough bone with an association between biomaterials and autogenous bone.Purpose: the purpose of this study was to evaluate histomorphometrically two grafting materials (calcium phosphate and Ricinus communis polymer) used in maxillary sinus floor augmentation associated with autogenous bone.Materials and Methods: Biopsies were taken from 10 consecutive subjects (mean age 45 years) 10 months after maxillary sinus floor augmentation. The sinus lift was performed with a mixture of autogenous bone and R. communis polymer or calcium phosphate in a 1:2 proportion. Routine histologic processing and staining with hernatoxylin and eosin were performed.Results: the histomorphometric analysis indicated satisfactory regenerative results in both groups for a mean of bone tissue in the grafted area (44.24 +/- 13.79% for the calcium phosphate group and 38.77 +/- 12.85% for the polymer group). Histologic evaluation revealed the presence of an inflammatory infiltrate of mononuclear prevalence that, on average, was nonsignificant. The histologic sections depicted mature bone with compact and cancellous areas in both groups.Conclusion: the results indicated that both graft materials associated with the autogenous bone were biocompatible, although both were still present after 10 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanostructured calcium phosphate (CaP) has been histologically and biomechanically proven to enhance osseointegration of implants; however, conventional techniques were not sufficiently sensitive to capture its biological effects fully. Here, we compared the conventional removal torque (RTQ) evaluation and gene expression in tissues around nanostructured CaP-coated implants, using real-time RT-PCR, with those of uncoated implants, in a rabbit model. At 2 wks, RTQ values were significantly higher, alkaline phosphatase (ALP) expression was significantly higher, and runt-related transcription factor 2 and tumor necrosis factor-alpha expressions were significantly lower in the coated than in the uncoated implants. This indicates that inflammatory responses were suppressed and osteoprogenitor activity increased around the CaP-coated surface. At 4 wks, although RTQ values did not significantly differ between the 2 groups, ALP and osteocalcin (OCN) were significantly up-regulated in the coated group, indicating progressive mineralization of the bone around the implant. Moreover, an osteoclast marker, adenosine triphosphatase, which indicates acidification of the resorption lacunae, was significantly higher for the coated implants, suggesting gradual resorption of the CaP coating. This study reveals detailed genetic responses to nanostructured CaP-coated implants and provides evidence that the effect of nanotopography is significant during the osseointegration cascade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanostructures on implant surfaces have been shown to enhance osseointegration; however, commonly used evaluation techniques are probably not sufficiently sensitive to fully determine the effects of this process. This study aimed to observe the osseointegration properties of nanostructured calcium phosphate (CaP)-coated implants, by using a combination of three-dimensional imaging and conventional histology. Titanium implants were coated with stable CaP nanoparticles using an immersion technique followed by heat treatment. Uncoated implants were used as the control. After topographical and chemical characterizations, implants were inserted into the rabbit femur. After 2 and 4 weeks, the samples were retrieved for micro-computed tomography and histomorphometric evaluation. Scanning electron microscopy evaluation indicated that the implant surface was modified at the nanoscale by CaP to obtain surface textured with rod-shaped structures. Relative to the control, the bone-to-implant contact for the CaP-coated implant was significantly higher at 4 weeks after the implant surgery. Further, corresponding 3-D images showed active bone formation surrounding the implant. 3-D quantification and 2-D histology demonstrated statistical correlation; moreover, 3-D quantification indicated a statistical decrease in bone density in the non-coated control implant group between 2 and 4 weeks after the surgery. The application of 3-D evaluation further clarified the temporal characteristics and biological reaction of implants in bone. (C) 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To evaluate the radiopacity of calcium hydroxide-based root canal sealers (Acroseal, Sealapex and Sealer 26), a glass-ionomer-based sealer (Activ GP Sealer) and a zinc oxide and eugenol-based sealer (Intrafill).Methodology Five disc-shaped specimens (10 x 1 mm) were fabricated from each material, according to the International Organization for Standardization (ISO) 6876/2001 standard. After setting of the materials, radiographs were taken using occlusal films and a graduated aluminum step-wedge varying from 2 to 16 mm in thickness. The dental X-ray unit (GE1000) was set at 50 Kvp, 10 mA, 18 pulses s(-1) and distance of 33.5 cm. The radiographs were digitized and the radiopacity compared with that of the aluminum step-wedge, using WIXWIN-2000 software (Gendex). Data (mm Al) were submitted to ANOVA and Tukey test.Results Intrafill was the most radiopaque material (7.67 mm Al) followed by Sealer 26 (6.33 mm Al), Sealapex (6.05 mm Al) and Acroseal (4.03 mm Al). Activ GP was the least radiopaque material (1.95 mm Al, P < 0.05).Conclusions The sealers evaluated in this study had different radiopacities. However, except for the glass-ionomer-based sealer, all materials had radiopacity values above the minimum recommended by the ISO standard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calcium channels mediate the actions of many drugs. The present work investigated whether diltiazem, an L-type calcium channel blocker, alters the inhibition of sodium appetite induced by noradrenaline and the alpha(2)-adrenoceptor agonist clonidine. Adult male Holtzman rats (N=4-8) with cannula implanted into the third cerebral ventricle were submitted to sodium depletion {furosemide sc+24-h removal of ambiente sodium). Sodium depleted control animals that received 0.9% NaCl as vehicle injected intracerebroventricularly (i.c.v) ingested 13.0+/-1.5 ml/120 min of 1.8% NaCl. Intracerebroventricular injection of either noradrenaline (80 nmol) or clonidine (20 nmol) inhibited 1.8% NaCl intake from 70 to 90%. Prior i.c.v. injection of diltiazem (6-48 nmol) inhibited from 50 to 100% the effect of noradrenaline and clonidine in a dose-response manner. Diltiazem alone at 100 nmol inhibited, but at 50 nmol had no effect on, sodium appetite. The results suggest: (1) common ionic mechanisms involving calcium channels for the inhibition that noradrenaline and clonidine exert on sodium appetite and (2) a dual role for the benzothiazepine site of L-type calcium channels in the control of sodium appetite. (C) 2002 Elsevier B.V. B V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calcium ions are widely accepted as critically important in responses of neurons to a stimulus. We have show previously the central involvement of angiotensin II (ANGII) in water intake. This study determined whether voltage-dependent calcium channels are involved in ANGII-induced behavioral drinking implicating nitrergic mechanism. The antidipsogenic actions of L-type calcium channel antagonists nifedipine, on ANGII-induced drinking behavior were studied when it is injected into the median preoptic nucleus (MnPO). The influence of nitric oxide (NO) on nifedipine antidipsogenic action was also studied by utilizing the N-W-nitro-L-arginine methyl ester (L-NAME) a constitutive nitric oxide synthase inhibitor constitutive (cNOSI) and 7-nitroindazol (7-NIT) a specific neuronal nitric oxide synthase inhibitor (nNOSI) and L-arginine a NO donor. Rats 200-250 g, with cannulae implanted into MnPO, pre-treated into MnPO with either nifedipine, followed by ANGII, drank significantly less water than controls during the first 15 min after injection. However, L-NAME potentiated the dipsogenic effect of ANGII that is blocked by prior injection of nifedipine and L-arginine. 7-NIT injected prior to ANGII into MnPO also potentiated the dipsogenic effect of ANGII but with a less intensity than L-NAME that it is also blocked by prior injection of nifedipine. The results described in this paper provide evidence that calcium channels play important roles in the ANGII-induced behavioral water intake. The structures containing NO in the brain such as MnPO include both endothelial cells and neurons might be responsible for the influence of nifedipine on dipsogenic effect of ANGII. These data shows the correlation between L-type calcium channel and a free radical gas NO produced endogenously from amino acids L-arginine by endothelial and neuronal NO synthase in the control of ANGII-dipsogenic effect. This suggests that an L-type calcium channel participates in both short- and longer-term neuronal actions of ANGII by nitrergic way. (c) 2006 Elsevier B.V. All rights reserved.