914 resultados para Biomechanical parameters
Resumo:
An experiment was carried out to establish mean bone quality values of the tibiae and femora of ostriches and to evaluate these bones. The right leg bones of 10 males and 10 female African Black ostriches were evaluated. Birds were radiographed immediately after slaughter (during bleeding), with the aid of a portable X-ray apparatus. The obtained radiographs were scanned and bone mineral density means were obtained using software. Bone strength, Seedor index, and dry matter percentage were evaluated and correlated to weight gain during the finishing period (3-13 months of age). Mean values of the evaluated bone quality traits, not previously found in literature, were established. There were no significant differences between males and females in performance or bone quality parameters. It was concluded that male and female ostriches present similar performance and bone quality at slaughter age.
Resumo:
Two experiments evaluated milk production, serum progesterone and insulin, and reproductive performance of lactating Holstein cows receiving or not receiving Ca salts of polyunsaturated fatty acids (PUFA), or receiving Ca salts of PUFA at different daily frequencies. In experiment 1, 1,125 cows randomly distributed in 10 freestall barns were enrolled. Barns were assigned randomly to receive a high-concentrate diet containing (PI?) or not containing (control, CON) 1.1% (dry matter basis) Ca salts of PUPA. Diets were offered 6 times daily, whereas the Ca salts of PUFA were included in the PF treatment in the first feeding of the day. In experiment 2, 1,572 cows were randomly distributed in 10 freestall barns, which were assigned randomly to receive a diet similar to PF, but with Ca salts of PUFA included only in the first feeding of the day (PF1X), or equally distributed across all 6 feedings (PF6X). During both experiments, cows were artificially inseminated 12 h after the onset of estrus. Once per month, cows that did not conceive to artificial insemination were assigned to a fixed-time embryo transfer protocol. Pregnancy was determined via transrectal ultrasonography 28 and 60 d after expected ovulation. Pregnancy loss was considered in cows that were pregnant on d 28 but nonpregnant on d 60. During both experiments, feed intake, milk yield, and milk protein and fat content were recorded weekly. Blood samples were collected concurrently with embryo transfer. During experiment 1, feed intake was similar between treatments. Compared with CON, PF cows had greater milk yield (37.8 vs. 35.3 kg/d), and reduced milk fat content (3.41 vs. 3.55%). However, PF cows had reduced pregnancy losses per service compared with CON (12.6 vs. 18.3%). Serum progesterone was greater and serum insulin tended to be greater in primiparous cows receiving PF compared with CON cohorts (4.50 vs. 3.67 ng of progesterone/mL, and 10.4 vs. 7.5 mu UI of insulin/mL). During experiment 2, no treatment effects were detected for feed intake, milk yield, or milk fat, whereas PF1X cows tended to have reduced pregnancy losses per service compared with PF6X (14.4 vs. 18.4%). In summary, feeding Ca salts of PUFA to dairy cows increased milk production, did not alter feed intake, and reduced pregnancy losses per service. Further, the total daily amount of Ca salts of RITA should be fed during the first feeding of the day to optimize its benefits on pregnancy maintenance of dairy cows.
Resumo:
Three semen samples were collected at 48 It intervals from 20 mature research dogs previously conditioned to manual semen collection. Vasectomy was performed in all dogs, and 15 days after surgery, another three ejaculates were similarly collected. The semen was evaluated, and centrifuged to obtain seminal plasma for measurement of pH, and concentrations of total proteins (TP), total chlorides (Cl), calcium (Ca), potassium (K), and sodium (Na). The seminal plasma protein profile was evaluated by SDS-PAGE; molecular weights and the integrated optical density (IOD) of each band were estimated. There was a negative correlation between K concentration and progressive motility (r = -0.49, P = 0.027), sperm vigor (r = -0.60, P = 0.0053), and plasma integrity, evaluated by both the hypo-osmotic swelling test (r = -0.50, P = 0.026) and a fluorescent stain (r = -0.45, P = 0.046). Positive correlations between Na and K pre- and post-vasectomy (r = 0.88, P < 0.001; r = 0.56, P < 0.01, respectively) were verified. There were a total of 37 bands pre-vasectomy and 35 post-vasectomy (range, 100.6-3.6 kDa). Bands B9 and B13 (42.6 and 29.2 kDa) were not present post-vasectomy. The IOD of band B3 (73.5 kDa) was higher (P 0.03) pre-vasectomy, compared to post-vasectomy; conversely, the IODs of bands B29 and B37 (7.8 and 3.6 kDa) increased (P 0.026 and 0.047). Pre-vasectomy, there was a positive correlation (r = 0.49, P = 0.029) between band B37 band (3.6 kDa) and the Na:K ratio. In conclusion, K appeared to be involved in sperm motility in dogs and could be a tool to evaluate sperm function. The prostate contributed several elements to canine seminal plasma. Vasectomy changed Ca concentrations and the protein profile of the seminal plasma. Further studies must be performed to clarify the function of these elements on the in vivo fertility of dogs. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Combining the data from conventional semen analysis with oocyte penetration assays should improve the assessment of the fertilizing ability of a semen sample. Thus, the objective of the present study was to evaluate the prognostic value of various semen parameters on the in vitro interactions between frozen-thawed canine sperm and homologous oocytes. Ten ejaculates from five stud dogs (two ejaculates/dog) were collected by digital manipulation. Semen samples were evaluated, extended in Tris-egg yolk-glycerol, frozen and stored in liquid nitrogen, and thawed several weeks later. Samples were evaluated for motility and sperm populations by computer-aided semen analysis (CASA), plasma membrane integrity (carboxy-fluorescein diacetate and propidium iodide), and sperm morphology (Bengal Rose). Thawed spermatozoa were also incubated with homologous oocytes for 18 h in an atmosphere of 5% CO2 and 95% air at 38 degrees C and sperm-oocyte interactions were evaluated. Simple linear regression models were calculated, with sperm parameters as independent variables and sperm-oocyte interactions as the dependent variable. There were significant associations between: percentage of oocytes bound to spermatozoa and beat cross frequency (BCF; R-2 = 63%); percentage of oocytes that interacted with spermatozoa and BCF (R-2 = 73%); and number of penetrated spermatozoa and velocity average pathway (VAP; R-2 = 64%) and velocity straight line (VSL; R-2 = 64%). Although plasma membrane integrity and sperm morphology had little prognostic value for in vitro interactions between canine frozen-thawed sperm and homologous oocytes, some motility patterns (evaluated by CASA) were predictive of in vitro sperm-oocyte interactions. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Surface and biomechanical analysis of titanium implant surfaces modified by laser beam with and without hydroxyapatite. Titanium implants with 3 different surfaces were inserted into the tibias of 30 rabbits: group I (GI) machined surface (control group), group II irradiated with laser (GII), and group III irradiated with laser and hydroxyapatite coating applied-biomimetic method (GIII). Topographical analysis with scanning electron microscopy was made before surgery in the tibia. These rabbits were distributed into 2 periods of observation: 4 and 8 weeks postsurgery, after which biomechanical analysis (removal torque) was conducted. Statistical analysis used the Student-Newman-Keuls method. Surface showed roughness in GII and GIII. Biomechanical analysis demonstrated values with significant differences in GII and GIII. Titanium implants modified by laser irradiation can increase osseointegration during the initial phase.
Resumo:
This study evaluated periapical tissue healing and orthodontic root resorption of endodontically treated teeth sealed with calcium hydroxide in dogs. The sample consisted of three contralateral pairs of maxillary incisors and two contralateral pairs of mandibular incisors in each of two dogs using a split mouth design. After biomechanical preparation of the teeth in the first group (n = 10), a Ca(OH)(2) dressing was placed for 14 days before root canal filling with Ca(OH)(2)-based sealer (Sealapex) and gutta-percha points. In the second group (n = 10), root canals were obturated immediately after the mechanical preparation with gutta-percha points and zinc oxide and eugenol (ZOE)-based sealer (Endofill). After completion of endodontic treatment, the teeth were moved with an orthodontic appliance with a calibrated force of 200 g, reactivated every 21 days. After 105 days, the animals were killed and the teeth were removed upon completion of active treatment, without a period of recovery, and prepared for histomorphological analysis. All sections of each tooth were graded subjectively on a scale from one to four to obtain the average of the 16 histomorphological parameters analysed. Evaluation of the differences between the two treatment protocols was made with Mann-Whitney U-test. It was observed that the teeth treated with Ca(OH)(2)-based materials provided better outcomes (P = 5%), with complete repair of all root resorption areas, high rate of biological closure of the main canal and apical accessory canals by newly formed cementum, less intense and extensive chronic inflammatory infiltrate, and better organization of the periodontal ligament. Under the tested conditions, Ca(OH)(2)-based materials had a favourable action on periapical tissue healing and repair of orthodontic root resorption in endodontically treated dogs' teeth.
Resumo:
Purpose: The aim of this in vitro study was to assess the biomechanical stability of 9 different osteosynthesis methods after sagittal split ramus osteotomy by simulating the masticatory forces and using a 3-point biomechanical test method.Materials and Methods: Forty-five polyurethane hemimandibles with bone-like consistency were randomly assigned to 9 groups (n = 5) and subjected to sagittal split ramus osteotomy. After 4-mm advancement of the distal segment, the bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplate/screw systems: group A, one 4-hole conventional straight miniplate; group B, one 4-hole locking straight miniplate; group C, one 4-hole conventional miniplate and one bicortical screw; group D, one 4-hole locking miniplate and 1 bicortical screw; group E, one 6-hole conventional straight miniplate; group F, one 6-hole locking straight miniplate; group (3: two 4-hole conventional straight miniplates; group H. two 4-hole locking straight miniplates; and group 1, 3 bicortical screws in an inverted-L. pattern. All models were mounted on a base especially constructed for this purpose. Using a 3-point biomechanical test model, the hemimandibles were loaded in compressive strength in an Instron machine (Norwood, MA) until a 3-mm displacement occurred between segments vertically or horizontally. Data were analyzed by analysis of variance and Tukey test (alpha = 1%).Results: The multiparametric comparison of the groups showed a statistically significant difference (P<.01) between groups that used 2 miniplates (groups G and H), 1 miniplate and 1 bicortical screw (groups C and D), and only bicortical screws (group D compared with groups that used only 1 miniplate with 2 screws per segment (groups A and B) and 3 screws per segment (groups E and F).Conclusion: The placement of 2.0-mm-diameter bicortical screws in the retromolar region, associated or not with conventional and locking miniplates with monocortical screws, promoted a better stabilization of bone segments. Locking miniplates presented a better performance in bone fixation in all groups. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:724-730, 2010
Resumo:
Purpose: The objective of this study was to evaluate, using three-dimensional finite element analysis (3D FEA), the stress distribution in peri-implant bone tissue, implants, and prosthetic components of implant-supported single crowns with the use of the platform-switching concept. Materials and Methods: Three 3D finite element models were created to replicate an external-hexagonal implant system with peri-implant bone tissue in which three different implant-abutment configurations were represented. In the regular platform (RP) group, a regular 4.1-mm-diameter abutment (UCLA) was connected to regular 4.1-mm-diameter implant. The platform-switching (PS) group was simulated by the connection of a wide implant (5.0 mm diameter) to a regular 4.1-mm-diameter UCLA abutment. In the wide-platform (WP) group, a 5.0-mm-diameter UCLA abutment was connected to a 5.0-mm-diameter implant. An occlusal load of 100 N was applied either axially or obliquely on the models using ANSYS software. Results: Both the increase in implant diameter and the use of platform switching played roles in stress reduction. The PS group presented lower stress values than the RP and WP groups for bone and implant. In the peri-implant area, cortical bone exhibited a higher stress concentration than the trabecular bone in all models and both loading situations. Under oblique loading, higher intensity and greater distribution of stress were observed than under axial loading. Platform switching reduced von Mises (17.5% and 9.3% for axial and oblique loads, respectively), minimum (compressive) (19.4% for axial load and 21.9% for oblique load), and maximum (tensile) principal stress values (46.6% for axial load and 26.7% for oblique load) in the peri-implant bone tissue. Conclusion: Platform switching led to improved biomechanical stress distribution in peri-implant bone tissue. Oblique loads resulted in higher stress concentrations than axial loads for all models. Wide-diameter implants had a large influence in reducing stress values in the implant system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:482-491
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In implant therapy, a peri-implant bone resorption has been noticed mainly in the first year after prosthesis insertion. This bone remodeling can sometimes jeopardize the outcome of the treatment, especially in areas in which short implants are used and also in aesthetic cases. To avoid this occurrence, the use of platform switching (PS) has been used. This study aimed to evaluate the biomechanical concept of PS with relation to stress distribution using two-dimensional finite element analysis. A regular matching diameter connection of abutment-implant (regular platform group [RPG]) and a PS connection (PS group [PSG]) were simulated by 2 two-dimensional finite element models that reproduced a 2-piece implant system with peri-implant bone tissue. A regular implant (prosthetic platform of 4.1 mm) and a wide implant (prosthetic platform of 5.0 mm) were used to represent the RPG and PSG, respectively, in which a regular prosthetic component of 4.1 mm was connected to represent the crown. A load of 100 N was applied on the models using ANSYS software. The RPG spreads the stress over a wider area in the peri-implant bone tissue (159 MPa) and the implant (1610 MPa), whereas the PSG seems to diminish the stress distribution on bone tissue (34 MPa) and implant (649 MPa). Within the limitation of the study, the PS presented better biomechanical behavior in relation to stress distribution on the implant but especially in the bone tissue (80% less). However, in the crown and retention screw, an increase in stress concentration was observed.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Purpose: To evaluate the biomechanical fixation, bone-to-implant contact (BIC), and bone morphology of screw-type root-form implants with healing chambers with as-machined or dual acid-etched (DAE) surfaces in a canine model. Materials and Methods: The animal model included the placement of machined (n = 24) and DAE (n = 24) implants along the proximal tibiae of six mongrel dogs, which remained in place for 2 or 4 weeks. Following euthanasia, half of the specimens were subjected to biomechanical testing (torque to interface failure) and the other half were processed for histomorphologic and histomorphometric (%BIC) assessments. Statistical analyses were performed by one-way analysis of variance at the 95% confidence level and the Tukey post hoc test for multiple comparisons. Results: At 4 weeks, the DAE surface presented significantly higher mean values for torque to interface failure overall. A significant increase in %BIC values occurred for both groups over time. For both groups, bone formation through the classic appositional healing pathway was observed in regions where intimate contact between the implant and the osteotomy walls occurred immediately after implantation. Where contact-free spaces existed after implantation (healing chambers), an intramembranous-like healing mode with newly formed woven bone prevailed. Conclusions: In the present short-term evaluation, no differences were observed in BIC between groups; however, an increase in biomechanical fixation was seen from 2 to 4 weeks with the DAE surface. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:75-82