909 resultados para Bias correction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Several conversion tables and formulas have been suggested to correct applanation intraocular pressure (IOP) for central corneal thickness (CCT). CCT is also thought to represent an independent glaucoma risk factor. In an attempt to integrate IOP and CCT into a unified risk factor and avoid uncertain correction for tonometric inaccuracy, a new pressure-to-cornea index (PCI) is proposed. METHODS: PCI (IOP/CCT(3)) was defined as the ratio between untreated IOP and CCT(3) in mm (ultrasound pachymetry). PCI distribution in 220 normal controls, 53 patients with normal-tension glaucoma (NTG), 76 with ocular hypertension (OHT), and 89 with primary open-angle glaucoma (POAG) was investigated. PCI's ability to discriminate between glaucoma (NTG+POAG) and non-glaucoma (controls+OHT) was compared with that of three published formulae for correcting IOP for CCT. Receiver operating characteristic (ROC) curves were built. RESULTS: Mean PCI values were: Controls 92.0 (SD 24.8), NTG 129.1 (SD 25.8), OHT 134.0 (SD 26.5), POAG 173.6 (SD 40.9). To minimise IOP bias, eyes within the same 2 mm Hg range between 16 and 29 mm Hg (16-17, 18-19, etc) were separately compared: control and NTG eyes as well as OHT and POAG eyes differed significantly. PCI demonstrated a larger area under the ROC curve (AUC) and significantly higher sensitivity at fixed 80% and 90% specificities compared with each of the correction formulas; optimum PCI cut-off value 133.8. CONCLUSIONS: A PCI range of 120-140 is proposed as the upper limit of "normality", 120 being the cut-off value for eyes with untreated pressures or=22 mm Hg. PCI may reflect individual susceptibility to a given IOP level, and thus represent a glaucoma risk factor. Longitudinal studies are needed to prove its prognostic value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to assess the performance of a new motion correction algorithm. Twenty-five dynamic MR mammography (MRM) data sets and 25 contrast-enhanced three-dimensional peripheral MR angiographic (MRA) data sets which were affected by patient motion of varying severeness were selected retrospectively from routine examinations. Anonymized data were registered by a new experimental elastic motion correction algorithm. The algorithm works by computing a similarity measure for the two volumes that takes into account expected signal changes due to the presence of a contrast agent while penalizing other signal changes caused by patient motion. A conjugate gradient method is used to find the best possible set of motion parameters that maximizes the similarity measures across the entire volume. Images before and after correction were visually evaluated and scored by experienced radiologists with respect to reduction of motion, improvement of image quality, disappearance of existing lesions or creation of artifactual lesions. It was found that the correction improves image quality (76% for MRM and 96% for MRA) and diagnosability (60% for MRM and 96% for MRA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To examine whether the association of inadequate or unclear allocation concealment and lack of blinding with biased estimates of intervention effects varies with the nature of the intervention or outcome. DESIGN: Combined analysis of data from three meta-epidemiological studies based on collections of meta-analyses. DATA SOURCES: 146 meta-analyses including 1346 trials examining a wide range of interventions and outcomes. MAIN OUTCOME MEASURES: Ratios of odds ratios quantifying the degree of bias associated with inadequate or unclear allocation concealment, and lack of blinding, for trials with different types of intervention and outcome. A ratio of odds ratios <1 implies that inadequately concealed or non-blinded trials exaggerate intervention effect estimates. RESULTS: In trials with subjective outcomes effect estimates were exaggerated when there was inadequate or unclear allocation concealment (ratio of odds ratios 0.69 (95% CI 0.59 to 0.82)) or lack of blinding (0.75 (0.61 to 0.93)). In contrast, there was little evidence of bias in trials with objective outcomes: ratios of odds ratios 0.91 (0.80 to 1.03) for inadequate or unclear allocation concealment and 1.01 (0.92 to 1.10) for lack of blinding. There was little evidence for a difference between trials of drug and non-drug interventions. Except for trials with all cause mortality as the outcome, the magnitude of bias varied between meta-analyses. CONCLUSIONS: The average bias associated with defects in the conduct of randomised trials varies with the type of outcome. Systematic reviewers should routinely assess the risk of bias in the results of trials, and should report meta-analyses restricted to trials at low risk of bias either as the primary analysis or in conjunction with less restrictive analyses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Suburethral slings are commonly used for the surgical treatment of female stress incontinence; occasionally they can cause erosion and dyspareunia. OBJECTIVES: The primary aim of this study is to determine the outcome after reclosure of the vaginal epithelium for suburethral sling erosion. Sexual function was assessed before and after intervention using the Female Sexual Function Index (FSFI) questionnaire. DESIGN, SETTING, AND PARTICIPANTS: This was a prospective case-controlled study in which, between December 2005 and December 2007, we included patients who were referred to the Department of Urogynaecology because of vaginal erosion after suburethral sling insertion for urinary stress incontinence. For evaluation of sexual function, all patients filled in an FSFI questionnaire before intervention and at follow-up. All patients underwent gynaecological examination including colposcopy, and the site and size of the defect were noted. INTERVENTION: The edge of the vaginal epithelium was trimmed, mobilized, and closed with interrupted vertical Vicryl mattress sutures in a single layer. MEASUREMENTS: FSFI questionnaire and clinical findings. RESULTS AND LIMITATIONS: Twenty-one patients were included in the study. Eighteen patients with larger defects were operated on, and three defects healed after topical application of estrogen cream. In 16 patients, the defect had healed at follow-up; two patients with persisting defects were brought back to surgery and the procedure was repeated, paying particular attention to tension-free adaptation of vaginal tissue. In one patient, partial sling removal was performed after the second failed intervention. The domains of desire (p<0.0001), arousal (p<0.0003), lubrication (p<0.0001), satisfaction (p<0.0130), and pain (p<0.0001) improved significantly. Orgasm remained unchanged (p=0.4130; all two-tailed t-test). CONCLUSION: Suburethral erosion can be treated effectively by resuturing. Sexual function is improved in regard to desire, arousal, lubrication, satisfaction, and pain, but not orgasm. In septic patients and patients with a history of radiation, grossly infected tissue, or severe pain, excision of the mesh needs to be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The increased use of meta-analysis in systematic reviews of healthcare interventions has highlighted several types of bias that can arise during the completion of a randomised controlled trial. Study publication bias has been recognised as a potential threat to the validity of meta-analysis and can make the readily available evidence unreliable for decision making. Until recently, outcome reporting bias has received less attention. METHODOLOGY/PRINCIPAL FINDINGS: We review and summarise the evidence from a series of cohort studies that have assessed study publication bias and outcome reporting bias in randomised controlled trials. Sixteen studies were eligible of which only two followed the cohort all the way through from protocol approval to information regarding publication of outcomes. Eleven of the studies investigated study publication bias and five investigated outcome reporting bias. Three studies have found that statistically significant outcomes had a higher odds of being fully reported compared to non-significant outcomes (range of odds ratios: 2.2 to 4.7). In comparing trial publications to protocols, we found that 40-62% of studies had at least one primary outcome that was changed, introduced, or omitted. We decided not to undertake meta-analysis due to the differences between studies. CONCLUSIONS: Recent work provides direct empirical evidence for the existence of study publication bias and outcome reporting bias. There is strong evidence of an association between significant results and publication; studies that report positive or significant results are more likely to be published and outcomes that are statistically significant have higher odds of being fully reported. Publications have been found to be inconsistent with their protocols. Researchers need to be aware of the problems of both types of bias and efforts should be concentrated on improving the reporting of trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Switching mode power supplies (SMPS) are subject to low power factor and high harmonic distortions. Active power-factor correction (APFC) is a technique to improve the power factor and to reduce the harmonic distortion of SMPSs. However, this technique results in double frequency output voltage variation which can be reduced by using a large output capacitance. Using large capacitors increases the cost and size of the converter. Furthermore, the capacitors are subject to frequent failures mainly caused by evaporation of the electrolytic solution which reduce the converter reliability. This thesis presents an optimal control method for the input current of a boost converter to reduce the size of the output capacitor. The optimum current waveform as a function of weighing factor is found by using the Euler Lagrange equation. A set of simulations are performed to determine the ideal weighing which gives the lowest possible output voltage variation as the converter still meets the IEC-61000-3-2 class-A harmonics requirements with a power factor of 0.8 or higher. The proposed method is verified by the experimental work. A boost converter is designed and it is run for different power levels, 100 W, 200 W and 400 W. The desired output voltage ripple is 10 V peak to peak for the output voltage of 200 Vdc. This ripple value corresponds to a ± 2.5% output voltage ripple. The experimental and the simulation results are found to be quite matching. A significant reduction in capacitor size, as high as 50%, is accomplished by using the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simulations of forest stand dynamics in a modelling framework including Forest Vegetation Simulator (FVS) are diameter driven, thus the diameter or basal area increment model needs a special attention. This dissertation critically evaluates diameter or basal area increment models and modelling approaches in the context of the Great Lakes region of the United States and Canada. A set of related studies are presented that critically evaluate the sub-model for change in individual tree basal diameter used in the Forest Vegetation Simulator (FVS), a dominant forestry model in the Great Lakes region. Various historical implementations of the STEMS (Stand and Tree Evaluation and Modeling System) family of diameter increment models, including the current public release of the Lake States variant of FVS (LS-FVS), were tested for the 30 most common tree species using data from the Michigan Forest Inventory and Analysis (FIA) program. The results showed that current public release of the LS-FVS diameter increment model over-predicts 10-year diameter increment by 17% on average. Also the study affirms that a simple adjustment factor as a function of a single predictor, dbh (diameter at breast height) used in the past versions, provides an inadequate correction of model prediction bias. In order to re-engineer the basal diameter increment model, the historical, conceptual and philosophical differences among the individual tree increment model families and their modelling approaches were analyzed and discussed. Two underlying conceptual approaches toward diameter or basal area increment modelling have been often used: the potential-modifier (POTMOD) and composite (COMP) approaches, which are exemplified by the STEMS/TWIGS and Prognosis models, respectively. It is argued that both approaches essentially use a similar base function and neither is conceptually different from a biological perspective, even though they look different in their model forms. No matter what modelling approach is used, the base function is the foundation of an increment model. Two base functions – gamma and Box-Lucas – were identified as candidate base functions for forestry applications. The results of a comparative analysis of empirical fits showed that quality of fit is essentially similar, and both are sufficiently detailed and flexible for forestry applications. The choice of either base function in order to model diameter or basal area increment is dependent upon personal preference; however, the gamma base function may be preferred over the Box-Lucas, as it fits the periodic increment data in both a linear and nonlinear composite model form. Finally, the utility of site index as a predictor variable has been criticized, as it has been widely used in models for complex, mixed species forest stands though not well suited for this purpose. An alternative to site index in an increment model was explored, using site index and a combination of climate variables and Forest Ecosystem Classification (FEC) ecosites and data from the Province of Ontario, Canada. The results showed that a combination of climate and FEC ecosites variables can replace site index in the diameter increment model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The STAndards for Reporting studies of Diagnostic accuracy (STARD) for investigators and editors and the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) for reviewers and readers offer guidelines for the quality and reporting of test accuracy studies. These guidelines address and propose some solutions to two major threats to validity: spectrum bias and test review bias. STUDY DESIGN AND SETTING: Using a clinical example, we demonstrate that these solutions fail and propose an alternative solution that concomitantly addresses both sources of bias. We also derive formulas that prove the generality of our arguments. RESULTS: A logical extension of our ideas is to extend STARD item 23 by adding a requirement for multivariable statistical adjustment using information collected in QUADAS items 1, 2, and 12 and STARD items 3-5, 11, 15, and 18. CONCLUSION: We recommend reporting not only variation of diagnostic accuracy across subgroups (STARD item 23) but also the effects of the multivariable adjustments on test performance. We also suggest that the QUADAS be supplemented by an item addressing the appropriateness of statistical methods, in particular whether multivariable adjustments have been included in the analysis.