831 resultados para Artificial eye
Resumo:
One objective of the feeder reconfiguration problem in distribution systems is to minimize the power losses for a specific load. For this problem, mathematical modeling is a nonlinear mixed integer problem that is generally hard to solve. This paper proposes an algorithm based on artificial neural network theory. In this context, clustering techniques to determine the best training set for a single neural network with generalization ability are also presented. The proposed methodology was employed for solving two electrical systems and presented good results. Moreover, the methodology can be employed for large-scale systems in real-time environment.
Resumo:
In this paper an artificial neural network (ANN) based methodology is proposed for (a) solving the basic load flow, (b) solving the load flow considering the reactive power limits of generation (PV) buses, (c) determining a good quality load flow starting point for ill-conditioned systems, and (d) computing static external equivalent circuits. An analysis of the input data required as well as the ANN architecture is presented. A multilayer perceptron trained with the Levenberg-Marquardt second order method is used. The proposed methodology was tested with the IEEE 30- and 57-bus, and an ill-conditioned 11-bus system. Normal operating conditions (base case) and several contingency situations including different load and generation scenarios have been considered. Simulation results show the excellent performance of the ANN for solving problems (a)-(d). (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Este artigo é uma tentativa de delinear as principais características da pesquisa numa nova área de estudos a chamada Inteligência Artificial (AI). Os itens 1 e 2 constituem um rápido histórico da AI e seus pressupostos básicos. O item 3 trata da teoria de resolução de problemas, desenvolvida por A. Newell e H. Simon. O item 4 procura mostrar a relevância da AI para a Filosofia, em especial para a filosofia da Mente e para a Teoria do Conhecimento.
Resumo:
O artigo aborda problemas filosóficos relativos à natureza da intencionalidade e da representação mental. A primeira parte apresenta um breve histórico dos problemas, percorrendo rapidamente alguns episódios da filosofia clássica e da filosofia contemporânea. A segunda parte examina o Chinese Room Argument (Argumento do Quarto do Chinês) formulado por J. Searle. A terceira parte desenvolve alguns argumentos visando mostrar a inadequação do modelo funcionalista de mente na construção de robots. A conclusão (quarta parte) aponta algumas alternativas ao modelo funcionalista tradicional, como, por exemplo, o conexionismo.
Resumo:
JUSTIFICATIVA E OBJETIVOS: em pacientes sob intubação traqueal ou traqueostomia, a umidificação e o aquecimento do gás inalado são necessários para a prevenção de lesões no sistema respiratório, conseqüentes ao contato do gás frio e seco com as vias aéreas. O objetivo da pesquisa foi avaliar o efeito do sistema respiratório circular com absorvedor de dióxido de carbono do aparelho de anestesia Cícero da Dräger, quanto à capacidade de aquecimento e umidificação dos gases inalados, utilizando-se fluxo baixo (1 L.min-1) ou mínimo (0,5 L.min-1) de gases frescos. MÉTODO: O estudo aleatório foi realizado em 24 pacientes, estado físico ASA I, com idades entre 18 e 65 anos, submetidos à anestesia geral, utilizando-se a Estação de Trabalho Cícero da Dräger (Alemanha), para realização de cirurgias abdominais, os quais foram distribuídos aleatoriamente em dois grupos: grupo de Baixo Fluxo (BF), no qual foi administrado 0,5 L.min-1 de oxigênio e 0,5 L.min-1 de óxido nitroso e fluxo mínimo (FM), administrando-se somente oxigênio a 0,5 L.min-1. Os atributos estudados foram temperatura, umidade relativa e absoluta da sala de operação e do gás no sistema inspiratório. RESULTADOS: Os valores da temperatura, umidade relativa e umidade absoluta no sistema inspiratório na saída do aparelho de anestesia e junto ao tubo traqueal não apresentaram diferença significante entre os grupos, mas aumentaram ao longo do tempo nos dois grupos (BF e FM), havendo influência da temperatura da sala de operação sobre a temperatura do gás inalado, nos dois grupos estudados. Níveis de umidade e temperatura próximos dos ideais foram alcançados, nos dois grupos, a partir de 90 minutos. CONCLUSÕES: Não há diferença significante da umidade e temperatura do gás inalado utilizando-se baixo fluxo e fluxo mínimo de gases frescos.
Resumo:
Foram eviscerados os globos oculares esquerdos de 32 ratos, linhagem Wistar, divididos em quatro grupos (A, B, C, D) constituídos, cada um, de cinco testemunhas e três controles. Nos animais-testemunha introduziu-se, dentro da capa córneo-escleral, uma esfera de resina acrílica (metilmetacrilato), previamente confeccionada e esterilizada por autoclavagem, ao passo que nos controles a cavidade eviscerada foi mantida sem prótese. Os ratos dos grupos A, B, C e D foram sacrificados respectivamente aos 7, 15, 30 e 90 dias de pós-operatório, quando os conteúdos orbitários esquerdos foram exenterados e preparados para o exame histopatológico. Observou-se que os animais-testemunha tiveram resposta inflamatória do tipo tecido de granulação ao redor da prótese de cavidade, com edema inflamatório da córnea especialmente nos grupos A e B, quando se iniciou a regressão da inflamação aguda. A cavidade orbitária manteve o tamanho em todos os grupos nos animais-testemunha e houve contração significativa nos animais-controle. Com estas observações, foi possível concluir que a esfera de resina acrílica é uma opção, de baixo custo e fácil confecção, para correção de defeito estético causado pela perda do globo ocular.
Resumo:
The fundamental senses of the human body are: vision, hearing, touch, taste and smell. These senses are the functions that provide our relationship with the environment. The vision serves as a sensory receptor responsible for obtaining information from the outside world that will be sent to the brain. The gaze reflects its attention, intention and interest. Therefore, the estimation of gaze direction, using computer tools, provides a promising alternative to improve the capacity of human-computer interaction, mainly with respect to those people who suffer from motor deficiencies. Thus, the objective of this work is to present a non-intrusive system that basically uses a personal computer and a low cost webcam, combined with the use of digital image processing techniques, Wavelets transforms and pattern recognition, such as artificial neural network models, resulting in a complete system that performs since the image acquisition (including face detection and eye tracking) to the estimation of gaze direction. The obtained results show the feasibility of the proposed system, as well as several feature advantages.
Resumo:
The present study evaluated the effect of artificial oocyte activation (AOA) with calcium ionophore A23187 oil intracytoplasmic sperm injection (ICSI) cycles using spermatozoa from different sources. The 314 cycles evaluated were divided into three groups according to sperm origin, the ejaculated group (n = 92), the epididymal group (n = 82). and the testicular roup (n = 140). Each group was further split into experimental subgroups, depending oil whether or no AOA was performed. In additions the cycles of women younger than 36 years were evaluated separately. For each experimental group, ICSI outcomes were compared between subgroups. No significant difference was observed between subgroups for all sperm origin groups. When evaluating only the cycles of women younger than 36 years of age, AOA increased the percentage of high-quality embryos (74.5 versus 53.0%. P = 0.011) and the implantation rate (19.3 versus 10.5%, P = 0.0025) when it was used with ejaculated spermatozoa, and the percentage of high-quality embryos (64.4 versus 50.3%, P = 0.006) when epididymal spermatozoa were used. These results may suggest that both sperm maturity and oocyte quality play a role in oocyte activation. However. this study is to be continued to confirm these findings.
Resumo:
Objective: To evaluate the effect of artificial oocyte activation (AOA) on intracytoplasmic sperm injection (ICSI) cycles using surgically retrieved sperm.Design: Laboratory study.Setting: Fertility/assisted fertilization center.Patient(s): Couples undergoing surgical sperm retrieval for ICSI (n = 204).Intervention(s): Application of calcium ionophore A23187 for AOA.Main Outcome Measure(s): Cycles were divided into experimental groups according to the origin of the sperm used for injection and the type of azoospermia: [1] testicular sperm aspiration in nonobstructive-azoospermic patients (TESA-NOA group, n = 58), [2] TESA in obstructive-azoospermic patients (TESA-OA group, n = 48), [3] and percutaneous epididymal sperm aspiration in obstructive-azoospermic patients (PESA-OA, n = 98). For each experimental group, cycles where AOA was applied (subgroup: activation) were compared with cycles in which AOA was not applied (Subgroup: control). The fertilization, high-quality embryo, implantation, and pregnancy rates were compared among the subgroups.Result(s): For patients undergoing TESA, AOA did not improve ICSI outcomes for either type of azoospermia. However, for cases in which the injected sperm were retrieved from the epididymis, a statistically significantly increased rate of high-quality embryos was observed with AOA.Conclusion(s): Artificial oocyte activation may improve ICSI outcomes in azoospermic patients when epididymal, but not testicular spermatozoa, are injected. (Fertil Steril (R) 2009;92:131-6. (C)2009 by American Society for Reproductive Medicine.)
Resumo:
Purpose: To investigate the dynamics of ocular eyelid movements in newborn infants and preschool-age children.Methods: Fifty newborn infants and 200 preschool children aged 4-6 years were examined. Images of each child, with his or her eyes in the primary eye position looking at an object placed at the child's height, were recorded with a digital videocamera for 3 mins. Complete and incomplete blink rates, opening, closing and complete blink times were calculated.Results: Newborn infants presented a lower number of incomplete movements than preschool children. The complete blink rate was lower in newborn infants (6.2 blinks/min) than in preschool children (8.0 blinks/minute). Eyelid closing, opening and compete blink times were longer in newborn infants than in preschool children at all observation times.Conclusions: Newborn infants had a different pattern of eyelid movement compared with preschool children. Specific characteristics that are found in this group of children particularly, such as immaturity of the neural system and more resistant tear film, may explain these findings in part.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To determine the most common approach to repair the anophthalmic socket in Brazil, and to compare the data with the trends in other countries.Methods: Exploratory study using electronic questionnaire sent by Internet to ophthalmologists members of the Brazilian Orbit and Oculoplastic Society (SBCPO). The received answers were analyzed by adhesion analysis, using Chi-square test.Results: We received 75 answered questionnaires. Fifty-three per cent of the respondents frequently treat anophthalmic socket and use the 18 mm diameter polymethylmethacrylate sphere in the majority of the surgeries, mainly covered by sclera (92%). Only seven interviewees had used integrated implants with pegging procedure. Eighty-two per cent of the ophthalmologists use the dermolipid graft to reconstruct the anophthalmic socket. They also follow the patients bi annually.Conclusions: The treatment of anophthalmic socket in Brazil generally involve polymethylmethacrylate sphere with 18 mm diameter. Pegging procedure is uncommon between us.