978 resultados para Aortic rupture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The cause precipitating intracranial aneurysm rupture remains unknown in many cases. It has been observed that aneurysm ruptures are clustered in time, but the trigger mechanism remains obscure. Because solar activity has been associated with cardiovascular mortality and morbidity, we decided to study its association to aneurysm rupture in the Swiss population. METHODS Patient data were extracted from the Swiss SOS database, at time of analysis covering 918 consecutive patients with angiography-proven aneurysmal subarachnoid hemorrhage treated at 7 Swiss neurovascular centers between January 1, 2009, and December 31, 2011. The daily rupture frequency (RF) was correlated to the absolute amount and the change in various parameters of interest representing continuous measurements of solar activity (radioflux [F10.7 index], solar proton flux, solar flare occurrence, planetary K-index/planetary A-index, Space Environment Services Center [SESC] sunspot number and sunspot area) using Poisson regression analysis. RESULTS During the period of interest, there were 517 days without recorded aneurysm rupture. There were 398, 139, 27, 12, 1, and 1 days with 1, 2, 3, 4, 5, and 6 ruptures per day. Poisson regression analysis demonstrated a significant correlation of F10.7 index and RF (incidence rate ratio [IRR] = 1.006303; standard error (SE) 0.0013201; 95% confidence interval (CI) 1.003719-1.008894; P < 0.001), according to which every 1-unit increase of the F10.7 index increased the count for an aneurysm to rupture by 0.63%. A likewise statistically significant relationship of both the SESC sunspot number (IRR 1.003413; SE 0.0007913; 95% CI 1.001864-1.004965; P < 0.001) and the sunspot area (IRR 1.000419; SE 0.0000866; 95% CI 1.000249-1.000589; P < 0.001) emerged. All other variables analyzed showed no significant correlation with RF. CONCLUSIONS We found greater radioflux, SESC sunspot number, and sunspot area to be associated with an increased count of aneurysm rupture. The clinical meaningfulness of this statistical association must be interpreted carefully and future studies are warranted to rule out a type-1 error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: A number of intrinsic and extrinsic risk factors for the rupture of intracranial aneurysms have been identified. Still, the cause precipitating aneurysm rupture remains unknown in many cases. In addition, it has been observed that aneurysm ruptures are clustered in time but the trigger mechanism remains obscure. As solar activity has been associated with cardiovascular mortality and morbidity we decided to study ist association to aneurysm rupture in the Swiss population. Method: Patient data was extracted from the Swiss SOS database, at time of analysis covering 918 patients with angiography-proven aSAH treated at seven Swiss neurovascular centers between 01/01/2009 – 12/31/2011. The number of aneurysm rupture per day, week, month (Daily/Weekly/Monthly Rupture Frequency = RF) was measured and correlated to the absolute amount and the change in various parameters of interest representing continuous measurements of solar activity (radioflux (F10.7 index), solar proton flux, solar flare occurrence, planetary K-index/planetary A-index) using Poisson regression analysis. Results: Of a consecutive series of 918 cases of SAH, precise determination of the date of symptom onset was possible in 816 (88.9%). During the period of interest there were 517 days without recorded aneurysm rupture. There were 398, 139, 27 and 12 days with 1, 2, 3, and 4 ruptures per day. Five or 6 ruptures were only noted on a single day each. Poisson regression analysis demonstrated a significant correlation of F10.7 index and aneurysm rupture (incidence rate ratio (IRR) = 1.006303; standard error (SE) 0.0013201; 95% confidence interval (CI) 1.003719 – 1.008894; p<0.001), according to which every 1-unit increase of the F10.7 index increased the count for an aneurysm to rupture by 0.63%. As the F10.7 index is known to correlate well with the Space Environment Services Center (SESC) sunspot number, we performed additional analyses on SESC sunspot number and sunspot area. Here, a likewise statistically significant relationship of both the SESC sunspot number (IRR 1.003413; SE 0.0007913; 95%CI 1.001864 – 1.004965; p<0.001) and the sunspot area (IRR 1.000419; SE 0.0000866; 95%CI 1.000249 – 1.000589; p<0.001) emerged. All other variables analyzed showed no correlation with RF. Conclusions: Using valid methods, we found higher radioflux, sunspot number and sunspot area to be associated with an increased count of aneurysm rupture. Since we were using rupture frequencies rather than incidences and because we cannot explain the physiological basis of this statistical association, the clinical meaningfulness of this statistical association must be interpreted carefully. Future studies are warranted to rule out a type-1 error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. Background Recently, the Symetis Acurate TA revalving system has been introduced for TA-TAVI. The Symetis Acurate TA aortic bioprosthesis is self-expanding and is deployed by a specific two-step implantation technique. Whether this novel method increases the load of intraprocedural emboli, detected by transcranial Doppler ultrasound (TCD) as HITS, or not is not clear. Methods Twenty-two patients (n = 11 in each study arm, median logistic EuroScore 20%, median STS score 7%) displayed continuous TCD signals of good quality throughout the entire TA-TAVI procedure and were included in the final analysis. Data are presented as median with interquartile ranges. Results No significant differences were detected in total procedural or interval-related HITS load (SA: 303 [200; 594], ES: 499 [285; 941]; p = 0.16). With both devices, HITS peaked during prosthesis deployment (PD), whereas significantly fewer HITS occurred during instrumentation (SA: p = 0.002; ES: <0.001) or post-implantation PI (SA: p = 0.007; ES: <0.001). PD-associated HITS amounted to almost half of the total HITS load. One patient suffered new disabling stroke at 30 days. Thirty-day mortality amounted to 13.6% (3 of 22 patients). Conclusions Simplified transapical delivery using the self-expanding SA device does not increase HITS, despite of a two-step deployment technique with more interactions with the native aortic valve, when compared to the balloon-expandable ES valve. The similarity in HITS count, frequency and pattern with the two systems suggests a common mechanism for the release of cerebral microemboli.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS In this work, we provide novel insight into the morphology of dissecting abdominal aortic aneurysms in angiotensin II-infused mice. We demonstrate why they exhibit a large variation in shape and, unlike their human counterparts, are located suprarenally rather than infrarenally. METHODS AND RESULTS We combined synchrotron-based, ultra-high resolution ex vivo imaging (phase contrast X-Ray tomographic microscopy) with in vivo imaging (high-frequency ultrasound and contrast-enhanced micro-CT) and image-guided histology. In all mice, we observed a tear in the tunica media of the abdominal aorta near the ostium of the celiac artery. Independently we found that, unlike the gradual luminal expansion typical for human aneurysms, the outer diameter increase of angiotensin II-induced dissecting aneurysms in mice was related to one or several intramural haematomas. These were caused by ruptures of the tunica media near the ostium of small suprarenal side branches, which had never been detected by the established small animal imaging techniques. The tear near the celiac artery led to apparent luminal dilatation, while the intramural haematoma led to a dissection of the tunica adventitia on the left suprarenal side of the aorta. The number of ruptured branches was higher in those aneurysms that extended into the thoracic aorta, which explained the observed variability in aneurysm shape. CONCLUSION Our results are the first to describe apparent luminal dilatation, suprarenal branch ruptures, and intramural haematoma formation in dissecting abdominal aortic aneurysms in mice. Moreover, we validate and demonstrate the vast potential of phase contrast X-ray tomographic microscopy in cardiovascular small animal applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To develop a method for computing and visualizing pressure differences derived from time-resolved velocity-encoded three-dimensional phase-contrast magnetic resonance imaging (4D flow MRI) and to compare pressure difference maps of patients with unrepaired and repaired aortic coarctation to young healthy volunteers. METHODS 4D flow MRI data of four patients with aortic coarctation either before or after repair (mean age 17 years, age range 3-28, one female, three males) and four young healthy volunteers without history of cardiovascular disease (mean age 24 years, age range 20-27, one female, three males) was acquired using a 1.5-T clinical MR scanner. Image analysis was performed with in-house developed image processing software. Relative pressures were computed based on the Navier-Stokes equation. RESULTS A standardized method for intuitive visualization of pressure difference maps was developed and successfully applied to all included patients and volunteers. Young healthy volunteers exhibited smooth and regular distribution of relative pressures in the thoracic aorta at mid systole with very similar distribution in all analyzed volunteers. Patients demonstrated disturbed pressures compared to volunteers. Changes included a pressure drop at the aortic isthmus in all patients, increased relative pressures in the aortic arch in patients with residual narrowing after repair, and increased relative pressures in the descending aorta in a patient after patch aortoplasty. CONCLUSIONS Pressure difference maps derived from 4D flow MRI can depict alterations of spatial pressure distribution in patients with repaired and unrepaired aortic coarctation. The technique might allow identifying pathophysiological conditions underlying complications after aortic coarctation repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Native-MR angiography (N-MRA) is considered an imaging alternative to contrast enhanced MR angiography (CE-MRA) for patients with renal insufficiency. Lower intraluminal contrast in N-MRA often leads to failure of the segmentation process in commercial algorithms. This study introduces an in-house 3D model-based segmentation approach used to compare both sequences by automatic 3D lumen segmentation, allowing for evaluation of differences of aortic lumen diameters as well as differences in length comparing both acquisition techniques at every possible location. METHODS AND MATERIALS Sixteen healthy volunteers underwent 1.5-T-MR Angiography (MRA). For each volunteer, two different MR sequences were performed, CE-MRA: gradient echo Turbo FLASH sequence and N-MRA: respiratory-and-cardiac-gated, T2-weighted 3D SSFP. Datasets were segmented using a 3D model-based ellipse-fitting approach with a single seed point placed manually above the celiac trunk. The segmented volumes were manually cropped from left subclavian artery to celiac trunk to avoid error due to side branches. Diameters, volumes and centerline length were computed for intraindividual comparison. For statistical analysis the Wilcoxon-Signed-Ranked-Test was used. RESULTS Average centerline length obtained based on N-MRA was 239.0±23.4 mm compared to 238.6±23.5 mm for CE-MRA without significant difference (P=0.877). Average maximum diameter obtained based on N-MRA was 25.7±3.3 mm compared to 24.1±3.2 mm for CE-MRA (P<0.001). In agreement with the difference in diameters, volumes obtained based on N-MRA (100.1±35.4 cm(3)) were consistently and significantly larger compared to CE-MRA (89.2±30.0 cm(3)) (P<0.001). CONCLUSIONS 3D morphometry shows highly similar centerline lengths for N-MRA and CE-MRA, but systematically higher diameters and volumes for N-MRA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose In this study, we show the use of three-dimensional printing models for preoperative planning of surgery for patients with complex aortic arch anomalies. Description A 70-year-old man with an extensively arteriosclerotic aneurysm reaching from the ascending aorta to the descending aorta was referred to our center for complete aortic arch replacement. We visualized and reconstructed computed tomography data of the patient and fabricated a flexible three-dimensional model of the aortic arch including the aneurysm. Evaluation This model was very helpful for the preoperative decision making and planning of the frozen elephant trunk procedure owing to the exact and lifelike illustration of the native aortic arch. Conclusions Three-dimensional models are helpful in preoperative planning and postoperative evaluation of frozen elephant trunk procedures in patients with complex aortic anatomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerous designs of bioprosthetic valves exist. The sutureless surgical valve is a newer design concept which combines elements of the transcatheter valve technology with surgical valves. This design aims at shorter and easier implantation. It was the aim of this study to perform hemodynamic and kinematic measurements for this type of valves to serve as a baseline for following studies which investigate the effect of the aortic root on the valve performance. To this end, the Edwards Intuity aortic valve was investigated in a new in vitro flow loop mimicking the left heart. The valve was implanted in a transparent, compliant aortic root model, and the valve kinematics was investigated using a high speed camera together with synchronized hemodynamic measurements of pressures and flows. The valve closure was asynchronous (one by one leaflet), and the valve started to close before the deceleration of the fluid. The aortic root model showed a dilation of the sinuses which was different to the ascending aorta, and the annulus was found to move towards the left ventricle during diastole and towards the aorta during systole.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To evaluate possible differences in periodontal inflammatory, microbiological and clinical parameters between women with preterm premature rupture of membranes (PPROM) and controls with uncomplicated pregnancies. MATERIALS AND METHODS Fifty-six women (32 test (PPROM) and 24 controls (uncomplicated pregnancies)) were examined at three time-points (T1: gestational weeks 20-35, T2: within 48 h after parturition, T3: 4-6 weeks after parturition). The examinations included assessment of the Periodontal Screening Index, collection of gingival crevicular fluid (GCF) and subgingival as well as vaginal bacterial sampling. RESULTS Periodontal inflammation was found to be higher in the test compared with the control group (p < 0.05) and decreased over time in both groups (p < 0.05). Microbiological outcomes showed no intergroup differences (p > 0.05) in prevalence of bacteria, but a decrease in subgingival periodontopathogens from T1 to T2 in the test group (p < 0.05) was observed. Interleukin (IL)-1β levels in GCF at T2 were not different between groups (p > 0.05). In women with PPROM, GCF levels of IL-8 (p < 0.05) and C-reactive protein (p < 0.05) were lower and IL-10 levels higher (p < 0.05) compared with controls. CONCLUSIONS Periodontal inflammation is elevated during pregnancy and seems to be more pronounced in women with PPROM. CLINICAL RELEVANCE The findings of the present study revealed an association between periodontal inflammation and PPROM, thus emphasizing the importance of optimizing self-performed oral hygiene in pregnant women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Purpose Aortic stenosis (AS) is the most common valvular abnormality in the elderly population. For inoperable patients or those at high-risk for surgery, transcatheter aortic valve implantation (TAVI) has become an alternative therapeutic option. The aim of the “Comprehensive geriatric assessment for transcatheter aortic valve implantation” (CGA-TAVI) registry is to evaluate the effectiveness of TAVI from the perspective of the geriatrician and to identify patient characteristics and indicators related to complications and clinical benefits for patients with symptomatic severe calcified degenerative AS undergoing TAVI. Materials and methods The CGA-TAVI registry is an international, multi-center, prospective, observational registry across Europe with consecutive patient enrolment. The registry will enrol up to 200 patients with AS undergoing TAVI, starting August 2013. CGA-TAVI has two co-primary objectives: (1) Establish predictive value of Comprehensive geriatric assessment (CGA) for mortality and/or hospitalization in TAVI patients. (2) Demonstrate CGA changes within 3 months after TAVI. Secondary objectives are: (1) Establish predictive value of CGA in TAVI patients for all-cause hospitalization, TAVI-related hospitalization, and nursing home admission. (2) Develop a comprehensive score for the assessment of TAVI patient prognosis. Conclusions The data obtained from the CGA-TAVI registry will supplement previous results to document the potential value of the effectiveness of TAVI from the perspective of geriatricians and will allow the assessment of the predictive value of CGA for mortality and/or hospitalization in elderly TAVI patients. Keywords Aortic stenosis; Transcatheter aortic valve implantation (TAVI); Comprehensive geriatric assessment (CGA); Registry; Predictor