955 resultados para Anatomía patológica


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mechanical response of the cornea subjected to a non-contact air-jet tonometry diagnostic test represents an interplay between its geometry, the corneal material behavior and the loading. The objective is to study this interplay to better understand and interpret the results obtained with a non-contact tonometry test. A patient-specific finite element model of a healthy eye, accounting for the load free configuration, was used. The corneal tissue was modeled as an anisotropic hyperelastic material with two preferential directions. Three different sets of parameters within the human experimental range obtained from inflation tests were considered. The influence of the IOP was studied by considering four pressure levels (10–28 mmHg) whereas the influence of corneal thickness was studied by inducing a uniform variation (300–600 microns). A Computer Fluid Dynamics (CFD) air-jet simulation determined pressure loading exerted on the anterior corneal surface. The maximum apex displacement showed a linear variation with IOP for all materials examined. On the contrary, the maximum apex displacement followed a cubic relation with corneal thickness. In addition, a significant sensitivity of the apical displacement to the corneal stiffness was also obtained. Explanation to this behavior was found in the fact that the cornea experiences bending when subjected to an air-puff loading, causing the anterior surface to work in compression whereas the posterior surface works in tension. Hence, collagen fibers located at the anterior surface do not contribute to load bearing. Non-contact tonometry devices give useful information that could be misleading since the corneal deformation is the result of the interaction between the mechanical properties, IOP, and geometry. Therefore, a non-contact tonometry test is not sufficient to evaluate their individual contribution and a complete in-vivo characterization would require more than one test to independently determine the membrane and bending corneal behavior.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we present a novel image processing algorithm providing good preliminary capabilities for in vitro detection of malaria. The proposed concept is based upon analysis of the temporal variation of each pixel. Changes in dark pixels mean that inter cellular activity happened, indicating the presence of the malaria parasite inside the cell. Preliminary experimental results involving analysis of red blood cells being either healthy or infected with malaria parasites, validated the potential benefit of the proposed numerical approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La diferencia de alineación de los ejes visuales en la Disparidad de Fijación en la gran mayoría de situaciones se produce como un efecto fisiológico no produciendo sintomatología al paciente. Sin embargo, existen ciertas situaciones en las que la Disparidad de Fijación sí que produce sintomatología al paciente, produciéndose como consecuencia del estrés de los sistemas de vergencia y acomodativo con el objetivo de mantener la visión binocular. Existen además evidencias científicas de que determinados hábitos de lectura, patologías como las migrañas y pacientes disléxicos con problemas de lectura y de aprendizaje pueden observar un incremento significativo de la Disparidad de Fijación, estando asociados a Disparidades de Fijación anormales. Debido a la información que proporciona la medida de la Disparidad de Fijación resulta de especial interés la cuantificación de la misma en la práctica clínica, existiendo en la actualidad diferentes tests y dispositivos clínicos que se utilizan comúnmente para la medida de la Disparidad de Fijación, como la Curva de Vergencias Forzadas, el Disparómetro de Sheedy, la Unidad de Mallet y la Carta de Wesson entre otros.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated the diffraction behavior of plasmonic Bessel beams propagating in metal-dielectric stratified materials and wire media. Our results reveal various regimes in which polarization singularities are selectively maintained. This polarization-pass effect can be controlled by appropriately setting the filling factor of the metallic inclusions and its internal periodic distribution. These results may have implications in the development of devices at the nanoscale level for manipulation of polarization and angular momentum of cylindrical vector beams.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For suitable illumination and observation conditions, sparkles may be observed in metallic coatings. The visibility of these sparkles depends critically on their intensity, and on the paint medium surrounding the metallic flakes. Based on previous perception studies from other disciplines, we derive equations for the threshold for sparkles to be visible. The resulting equations show how the visibility of sparkles varies with the luminosity and distance of the light source, the diameter of the metallic flakes, and the reflection properties of the paint medium. The predictions are confirmed by common observations on metallic sparkle. For example, under appropriate conditions even metallic flakes as small as 1 μm diameter may be visible as sparkle, whereas under intense spot light the finer grades of metallic coatings do not show sparkle. We show that in direct sunlight, dark coarse metallic coatings show sparkles that are brighter than the brightest stars and planets in the night sky. Finally, we give equations to predict the number of visually distinguishable flake intensities, depending on local conditions. These equations are confirmed by previous results. Several practical examples for applying the equations derived in this article are provided.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Retinal neurodegenerative diseases like age-related macular degeneration, glaucoma, diabetic retinopathy and retinitis pigmentosa each have a different etiology and pathogenesis. However, at the cellular and molecular level, the response to retinal injury is similar in all of them, and results in morphological and functional impairment of retinal cells. This retinal degeneration may be triggered by gene defects, increased intraocular pressure, high levels of blood glucose, other types of stress or aging, but they all frequently induce a set of cell signals that lead to well-established and similar morphological and functional changes, including controlled cell death and retinal remodeling. Interestingly, an inflammatory response, oxidative stress and activation of apoptotic pathways are common features in all these diseases. Furthermore, it is important to note the relevant role of glial cells, including astrocytes, Müller cells and microglia, because their response to injury is decisive for maintaining the health of the retina or its degeneration. Several therapeutic approaches have been developed to preserve retinal function or restore eyesight in pathological conditions. In this context, neuroprotective compounds, gene therapy, cell transplantation or artificial devices should be applied at the appropriate stage of retinal degeneration to obtain successful results. This review provides an overview of the common and distinctive features of retinal neurodegenerative diseases, including the molecular, anatomical and functional changes caused by the cellular response to damage, in order to establish appropriate treatments for these pathologies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optic neuritis is an inflammation of the optic nerve and may be related to different systemic conditions. The clinical presentation of this pathology usually includes sudden loss of visual acuity (VA) which may be unilateral or bilateral, visual field restriction, pain with eye movements, dyschromatopsia, a relative afferent pupillary defect and optic disk swelling. Optic neuritis in children has specific clinical features and a better prognosis than in adulthood. Although usually appears an underlying viral disease, the main concern for practitioners is the relationship of optic neuritis with multiple sclerosis. In addition to the classical techniques as magnetic resonance imaging (MRI), current tendencies of diagnosis for eye practitioners include new imaging devices as optical coherence tomography (OCT), useful to show a thinning of the retinal fibers layer (RFL) after the inflammatory episode. Regarding the management of these patients, short-term intravenous steroid dosages seem to be the best option to treat acute attacks characterized by a very poor bilateral VA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare anterior and posterior corneal curvatures between eyes with primary open-angle glaucoma (POAG) and healthy eyes. Methods: This is a prospective, cross-sectional, observer-masked study. A total of 138 white subjects (one eye per patient) were consecutively recruited; 69 eyes had POAG (study group), and the other 69 comprised a group of healthy control eyes matched for age and central corneal pachymetry with the study ones. Exclusion criteria included any corneal or ocular inflammatory disease, previous ocular surgery, or treatment with carbonic anhydrase inhibitors. The same masked observer performed Goldmann applanation tonometry, ultrasound pachymetry, and Orbscan II topography in all cases. Central corneal thickness, intraocular pressure, and anterior and posterior topographic elevation maps were analyzed and compared between both groups. Results: Patients with POAG had greater forward shifting of the posterior corneal surface than that in healthy control eyes (p < 0.01). Significant differences in anterior corneal elevation between controls and POAG eyes were also found (p < 0.01). Conclusions: Primary open-angle glaucoma eyes have a higher elevation of the posterior corneal surface than that in central corneal thickness–matched nonglaucomatous eyes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biomechanics is often defined as ‘mechanics applied to biology’. Due to the variety and complexity of the behaviour of biological structures and materials, biomechanics is better defined as the development, extension and application of mechanics for a better understanding of physiology and physiopathology and consequently for a better diagnosis and treatment of disease and injury. Different methods for the characterisation of corneal biomechanics are reviewed in detail, including those that are currently commercially available (Ocular Response Analyzer and CorVis ST). The clinical applicability of the parameters provided by these devices are discussed, especially in the fields of glaucoma, detection of ectatic disorders and orthokeratology. Likewise, other methods are also reviewed, such as Brillouin microscopy or dynamic optical coherence tomography and others with potential application to clinical practice but not validated for in vivo measurements, such as ultrasonic elastography. Advantages and disadvantages of all these techniques are described. Finally, the concept of biomechanical modelling is revised as well as the requirements for developing biomechanical models, with special emphasis on finite element modelling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the possible associations between corneal biomechanical parameters, optic disc morphology, and retinal nerve fiber layer (RNFL) thickness in healthy white Spanish children. Methods: This cross-sectional study included 100 myopic children and 99 emmetropic children as a control group, ranging in age from 6 to 17 years. The Ocular Response Analyzer was used to measure corneal hysteresis (CH) and corneal resistance factor. The optic disc morphology and RNFL thickness were assessed using posterior segment optical coherence tomography (Cirrus HD-OCT). The axial length was measured using an IOLMaster, whereas the central corneal thickness was measured by anterior segment optical coherence tomography (Visante OCT). Results: The mean (±SD) age and spherical equivalent were 12.11 (±2.76) years and −3.32 (±2.32) diopters for the myopic group and 11.88 (±2.97) years and +0.34 (±0.41) diopters for the emmetropic group. In a multivariable mixed-model analysis in myopic children, the average RNFL thickness and rim area correlated positively with CH (p = 0.007 and p = 0.001, respectively), whereas the average cup-to-disc area ratio correlated negatively with CH (p = 0.01). We did not observe correlation between RNFL thickness and axial length (p = 0.05). Corneal resistance factor was only positively correlated with the rim area (p = 0.001). The central corneal thickness did not correlate with the optic nerve parameters or with RNFL thickness. These associations were not found in the emmetropic group (p > 0.05 for all). Conclusions: The corneal biomechanics characterized with the Ocular Response Analyzer system are correlated with the optic disc profile and RNFL thickness in myopic children. Low CH values may indicate a reduction in the viscous dampening properties of the cornea and the sclera, especially in myopic children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the relationship between different ocular and corneal biomechanical parameters in emmetropic and ametropic healthy white children. Methods: This study included 293 eyes of 293 healthy Spanish children (135 boys and 158 girls), ranging in age from 6 to 17 years. Subjects were divided according to the refractive error: control (emmetropia, 99 children), myopia (100 children), and hyperopia (94 children) groups. In all cases, corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer system. Axial length (AL) and mean corneal power were also measured by partial coherence interferometry (IOLMaster), and central corneal thickness (CCT) and anterior chamber depth were measured by anterior segment optical coherence tomography (Visante). Results: Mean (±SD) CH and CRF were 12.12 (±1.71) and 12.30 (±1.89) mm Hg, respectively. Mean (±SD) CCT was 542.68 (±37.20) μm and mean (±SD) spherical equivalent was +0.14 (±3.41) diopters. A positive correlation was found between CH and CRF (p < 0.001), and both correlated as well with CCT (p < 0.0001). Corneal resistance factor was found to decrease with increasing age (p = 0.01). Lower levels of CH were associated with longer AL and more myopia (p < 0.001 and p = 0.001, respectively). Higher values of CH were associated with increasing hyperopia. Significant differences in CH were found between emmetropic and myopic groups (p < 0.001) and between myopic and hyperopic groups (p = 0.011). There were also significant differences in CRF between emmetropic and myopic groups (p = 0.02). Multiple linear regression analysis showed that lower CH and CRF significantly associated with thinner CCT, longer AL, and flatter corneal curvature. Conclusions: The Ocular Response Analyzer corneal biomechanical properties seem to be compromised in myopia from an early age, especially in high myopia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the case of an eight-year-old girl with complaints of headaches and blurred vision (uncorrected visual acuity: 0.1 decimal) that showed on examination miotic pupils, pseudomyopia, no ocular motility restrictions, and no associated neurological disease. After initial treatment with cyclopentolate for two months, pseudomyopia persisted with an intermittent and variable esotropia. Spectacles of +1 both eyes and atropine 1% one drop daily were then prescribed. The situation improved and remained stable for several weeks, with pseudomyopia and esotropia reappearing later. Finally, botulinum toxin (2.5 iu Botox®) was injected in the medial rectus muscle on two occasions and a visual therapy program based on the stimulation of fusional divergence, diplopia, and stereopsis consciousness was recommended. This prescription was combined with the use of atropine during the first few weeks. Orthotropia and corrected distance visual acuity of 1.0 were found three months after treatment. The evolution and clinical results of this case report suggest that botulinum toxin in combination with other therapeutic alternatives may be useful in the treatment of spasm of the near reflex.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate and compare the visual, refractive, contrast sensitivity, and aberrometric outcomes with a diffractive bifocal and trifocal intraocular lens (IOL) of the same material and haptic design. METHODS: Sixty eyes of 30 patients undergoing bilateral cataract surgery were enrolled and randomly assigned to one of two groups: the bifocal group, including 30 eyes implanted with the bifocal diffractive IOL AT LISA 801 (Carl Zeiss Meditec, Jena, Germany), and the trifocal group, including eyes implanted with the trifocal diffractive IOL AT LISA tri 839 MP (Carl Zeiss Meditec). Analysis of visual and refractive outcomes, contrast sensitivity, ocular aberrations (OPD-Scan III; Nidek, Inc., Gagamori, Japan), and defocus curve were performed during a 3-month follow-up period. RESULTS: No statistically significant differences between groups were found in 3-month postoperative uncorrected and corrected distance visual acuity (P > .21). However, uncorrected, corrected, and distance-corrected near and intermediate visual acuities were significantly better in the trifocal group (P < .01). No significant differences between groups were found in postoperative spherical equivalent (P = .22). In the binocular defocus curve, the visual acuity was significantly better for defocus of -0.50 to -1.50 diopters in the trifocal group (P < .04) and -3.50 to -4.00 diopters in the bifocal group (P < .03). No statistically significant differences were found between groups in most of the postoperative corneal, internal, and ocular aberrations (P > .31), and in contrast sensitivity for most frequencies analyzed (P > .15). CONCLUSIONS: Trifocal diffractive IOLs provide significantly better intermediate vision over bifocal IOLs, with equivalent postoperative levels of visual and ocular optical quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabajo de revisión analiza toda la bibliografía encontrada en MEDLINE a través de PubMed y Ovid sobre lentes de contacto híbridas. En él se presenta la evolución de este tipo de lentes hasta los últimos estudios sobre las lentes SynergEyes. Se dan unas pautas de adaptación para alguno de estos tipos de lentes y se analizan sus diferentes usos. Se estudia la adaptación de lentes en casos de queratocono y otras ectasias corneales, comparando los distintos tipos de lentes utilizados así como los resultados que ofrecen las lentes de contacto híbridas en estos casos. Se comenta la función de este tipo de lentes en casos de córnea irregular poscirugía refractiva, así como en casos de posqueratoplastia. Por último, se analizan brevemente los nuevos avances realizados por los laboratorios especializados en este tipo de lentes de contacto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper illustrates how to design a visual experiment to measure color differences in gonioapparent materials and how to assess the merits of different advanced color-difference formulas trying to predict the results of such experiment. Successful color-difference formulas are necessary for industrial quality control and artificial color-vision applications. A color- difference formula must be accurate under a wide variety of experimental conditions including the use of challenging materials like, for example, gonioapparent samples. Improving the experimental design in a previous paper [Melgosaet al., Optics Express 22, 3458-3467 (2014)], we have tested 11 advanced color-difference formulas from visual assessments performed by a panel of 11 observers with normal colorvision using a set of 56 nearly achromatic colorpairs of automotive gonioapparent samples. Best predictions of our experimental results were found for the AUDI2000 color-difference formula, followed by color-difference formulas based on the color appearance model CIECAM02. Parameters in the original weighting function for lightness in the AUDI2000 formula were optimized obtaining small improvements. However, a power function from results provided by the AUDI2000 formula considerably improved results, producing values close to the inter-observer variability in our visual experiment. Additional research is required to obtain a modified AUDI2000 color-difference formula significantly better than the current one.