815 resultados para Alternative Therapies
Resumo:
The present work, studied the effect of 0, 1,000, 1,500 and 2,000 mg of garlic powder/kg dry ration for Piaractus mesopotamicus (Osteichthyes Characidae), weighting 73.6+/-39.4 9 and measuring 15.0+/-2.7 cm, fed for a period of 15, 30 and 45 days. Fifteen days after treatment with 1,000 and 2,000 Prig of garlic/kg dry ration, significant reduction of Anacanthorus penilabiatus (Monogenea: Dactylogyridae) in the gills was related. Nevertheless, the addition of garlic to the ration caused significant increase in the erythrocyte number and in the thrombocyte percentage in the circulating blood. However, a decrease in the lymphocyte percentage was also observed. After 45 days, fish fed with garlic showed significant increase in the erythrocyte number, leucocyte, haemoglobin rate, hematocrit and thrombocyte.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A new methodology for tree seedling production (Aquaforest system) based on a continuous floating subirrigation system was developed and tested using creeks with different nutrient levels. Eucalyptus grandis seedlings were produced in water from polluted and clean creeks, and compared to conventional tree nursery production. The growth variables analyzed in the seedling phase were: survival, height, diameter, shoot and root dry weight, leaf area, and root/shoot ratio. Water and substrate were analyzed, as well as leaf nutritional status. Plant survival was 100% in all treatments. Height and diameter were greater in the higher nutrient water treatment. Leaf area and dry weight of plants produced in the higher nutrient water treatment were similar to those of the control. The results showed that polluted water can represent a good nutrient source. The preliminary results show that the Aquaforest system can be a viable alternative for tree seedling production. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
O uso de fontes não convencionais para fornecimento de K às plantas tem sido amplamente estudado, mas os efeitos de materiais alternativos na qualidade fisiológica das sementes não são conhecidos. Este estudo teve como objetivo avaliar a qualidade fisiológica de sementes de soja e trigo em função da aplicação fontes de potássio em uma sucessão de culturas. O delineamento experimental foi o de blocos ao acaso com quatro repetições. Os tratamentos constaram de três fontes de K (KCl, rocha alcalina e fonolito moído, com 58%, 11% e 8.42% de K2O, respectivamente) aplicados em quatro doses (0, 25, 50 e 100 kg K2O ha-1). As doses de potássio foram aplicadas na soja e seu efeito residual foi avaliado na cultura do trigo, cultivado em sucessão. Logo após a colheita, as sementes de soja e trigo foram avaliadas pelos testes de teor de água, massa de sementes, germinação, primeira contagem, condutividade elétrica, comprimento de plântulas e massa da matéria seca de plântulas. Plantas de soja adubadas com fontes alternativas para fornecimento de K produzem sementes com maior massa e menor permeabilidade de membranas comparado às com KCl; maior qualidade fisiológica de sementes de soja e massa de sementes de trigo são obtidas com maiores doses de K2O independente da fonte.
Resumo:
Os ensaios de largura de trabalho e uniformidade de distribuição são de difícil execução para o agricultor por exigirem equipamentos, recursos e métodos complexos. Portanto, este trabalho teve como objetivo avaliar coletores alternativos para tornar mais acessível a regulagem e a avaliação de distribuidores de fertilizantes sólidos a lanço. Foram utilizados quatro diferentes conjuntos de coletores: i) coletores construídos segundo a norma ISO 5690/1; ii) coletores de polietileno (bandejas plásticas) com tela de sombreamento para evitar o ricochete de material; iii) coletores formados por caixas de leite longa vida, e iv) coletores formados por vasos de polietileno (número 3,5). Também foram utilizados três diferentes distribuidores para as avaliações. Os coletores alternativos apresentaram maior retenção de partículas que os coletores normatizados. A largura efetiva de trabalho obtida para os coeficientes de variação de 12,5; 15; 17,5 e 20% variou entre os coletores nos diferentes percursos. O coletor que mais se assemelhou à norma foram os vasos de polietileno. Constatou-se que a altura dos coletores foi mais importante para sua eficiência do que a sua área de coleta.
Resumo:
The ionospheric effect is one of the major errors in GPS data processing over long baselines. As a dispersive medium, it is possible to compute its influence on the GPS signal with the ionosphere-free linear combination of L1 and L2 observables, requiring dual-frequency receivers. In the case of single-frequency receivers, ionospheric effects are either neglected or reduced by using a model. In this paper, an alternative for single-frequency users is proposed. It involves multiresolution analysis (MRA) using a wavelet analysis of the double-difference observations to remove the short- and medium-scale ionosphere variations and disturbances, as well as some minor tropospheric effects. Experiments were carried out over three baseline lengths from 50 to 450 km, and the results provided by the proposed method were better than those from dual-frequency receivers. The horizontal root mean square was of about 0.28 m (1 sigma).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The determination of leukocyte alkaline phosphatasd (LAP) is used as an aid to diagnose many diseases in the laboratory. For example, it can be used to distinguish chronic myeloid leukemia (CML) from other myeloproliferative disorders (particularly myelofibrosis and polycythemia) and leukemoid reactions (LR). Traditionally, this test is performed with the use of subjective cytochemical assays that assign a score to the level of LAP. Here we present a nonsubjective, quantitative, sensitive, and inexpensive chemiluminescent technique that determines LAP based on the commercial reagent Immulite (R) (AMPPD). To validate this methodology, intact leukocytes obtained from 32 healthy subjects, nine CML patients, and nine LR patients were submitted to the optimized protocol. By measuring the light emission elicited by four concentrations of neutrophils, we were able to estimate the activity of LAP per cell (the slope of the curve obtained by linear regression). A high linear correlation was found between the chemiluminescent result (slope) and the cytochemical score. The slope for healthy individuals ranged between 0.61 and 8.49 (10(-5) mV.s/cell), with a median of 2.04 (10(-5) mV.s/cell). These results were statistically different from those of CML patients (range = 0.07-1.75, median = 0.79) and LR patients (range = 3.84-47.24, median 9.58; P < 0.05).
Resumo:
Importance of the field: The use of topical agents poses unique and challenging hurdles for drug delivery. Topical steroids effectively control ocular inflammation, but are associated with the well-recognized dilemma of patient compliance. Although administration of topical antimicrobials as prophylaxis is acceptable among ophthalmologists, this common practice has no sound evidence base Developing a new antimicrobial agent or delivery strategy with enhanced penetration by considering the anatomical and physiological constraints exerted by the barriers of the eye is not a commonly perceived strategy. Exploiting the permeability of the sclera, subconjunctival routes may offer a promising alternative for enhanced drug delivery and tissue targeting.Area covered in this review: Ocular drug delivery strategies were reviewed for ocular inflammation and infections clinically adopted for newer class of antimicrobials, which use a multipronged approach to limit risks of endophthalmitis.What the reader will gain: The analysis substantiates a new transscleral drug delivery therapeutic approach for cataract surgery.Take home message: A new anti-inflammatory and anti-infective paradigm that frees the patient from the nuisance of topical therapeutics is introduced, opening a large investigative avenue for future improved therapies.
Resumo:
Owing to their massive use, Staphylococcus epidermidis has recently developed significant resistance to several antibiotics, and became one of the leading causes of hospital-acquired infections. Current antibiotics are typically ineffective in the eradication of bacteria in biofilm-associated persistent infections. Accordingly, the paucity of effective treatment against cells in this mode of growth is a key factor that potentiates the need for new agents active in the prevention or eradication of biofilms. Daptomycin and linezolid belong to the novel antibiotic therapies that are active against gram-positive cocci. on the other hand, rifampicin has been shown to be one of the most potent, prevalent antibiotics against S. epidermidis biofilms. Therefore, the main aim of this study was to study the susceptibility of S. epidermidis biofilm cells to the two newer antimicrobial agents previously mentioned, and compare the results obtained with the antimicrobial effect of rifampicin, widely used in the prevention/treatment of indwelling medical device infections. To this end the in vitro activities of daptomycin, linezolid, and rifampicin on S. epidermidis biofilms were accessed, using these antibiotics at MIC and peak serum concentrations. The results demonstrated that at MIC concentration, rifampicin was the most effective antibiotic tested. At peak serum concentration, both strains demonstrated similar susceptibility to rifampicin and daptomycin, with colony-forming units (CFUs) reductions of approximately 3-4 log(10), with a slightly lower response to linezolid, which was also more strain dependent. However, considering all the parameters studied, daptomycin was considered the most effective antibiotic tested, demonstrating an excellent in vitro activity against S. epidermidis biofilm cells. In conclusion, this antibiotic can be strongly considered as an acceptable therapeutic option for S. epidermidis biofilm-associated infections and can represent a potential alternative to rifampicin in serious infections where rifampicin resistance becomes prevalent.
Resumo:
Reusing scrap tires has become a worldwide challenge, especially due to the great difficulty in finding ecologically and economically feasible ways to dispose of them. This has led to the creation of specific programs and legislation for reusing scrap tires. Research has shown that a certain percentage of scrap tire rubber can be added to asphalt compositions, and this has become a worldwide practice. This paper describes the properties of four asphalt compositions modified with scrap tire rubber (STR) prepared in the laboratory. These properties are then compared with those of asphalt modified with styrene butadiene styrene (SBS), a synthetic polymer and one of the most common modifiers, to verify the feasibility of using scrap tire rubber as a substitute for SBS. The scope of this study does not include an analysis of how STR affects end-of-life asphalt. The main findings indicate that STR is a potential substitute of SBS in paving material, and although it does not meet some of the standard specifications when compared with SBS, these issues can be overcome by proper care during storage and transportation. The substitution of SBS by STR also showed the potential for about 10% in expenditure savings. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
This article presents a cooling system for cutting tool in turning based in a toolholder with cooling fluid flowing inside its body being that this fluid must necessarily be able to phase change due to heat generated from machining processes. In this way, the fluid evaporates just under the cutting tool allowing a heat transfer more efficient than if were used a fluid without phase change once the latent heat of evaporation is beneficial for removal heat. Following, the cooling fluid evaporated passes through a condenser located out of the toolholder where it is condensated and returns to the toolholder again and a new cycle is started. In this study, the R-123, a hydrochlorofluorocarbon (HCFC) fluid, was selected for the turning of a Cr-Ni-Nb-Mn-N austenitic steel of hard machinability. The machining tests were carried out under three different machining conditions: dry machining, external cutting fluid (conventional method), and with the toolholder proposed. As result, the developed system allows a surface roughness up to 10% better than dry machining and a tool life close to the conventional method, but 32% superior to dry machining; moreover, there are environmental and economics advantages once the cooling fluid is maintained in a loop circuit.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)