991 resultados para Active Oxygen


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose/Objective: Tuberculosis (TB) is the second worldwide leading cause of death from an infectious disease after HIV infection. Protective immunity to Mycobacterium tuberculosis (Mtb) remains poorly understood and the role of Mtb-specific CD8 T-cells is controversial. We performed comprehensive functional and phenotypic characterizations of Mtb-specific CD8 T-cell responses in 273 subjects with either latent Mtb infection (LTBI) or active TB disease (TB) to assess their profile and relevance in TB. Materials and methods: Using multi-parametric flow cytometry, we assessed Mtb-specific CD8 T-cell functional (production of IFNgamma, IL-2 and TNF-alpha; proliferation capacity and cytotoxicity) and phenotypic (T-cell differentiation and exhaustion) profiles in cells isolated from peripheral blood and correlated these profiles with distinct clinical presentations. Results: Mtb-specific CD8 T-cells were detected in most TB patients and few LTBI subjects (65% and 15%, respectively; P < 0.00001) and were of similar magnitude with a comparable cytokines profile (IFNg+TNFa+IL2-) in both groups. Mtb-specific CD8 T-cells were mostly TEMRA (CD45RA+ CCR7-) co-expressing 2B4 and CD160 in LTBI subjects and mostly TEM (CD45RA-CCR7-) lacking PD-1/ CD160/2B4 in TB patients. Furthermore, Mtb-specific CD8 T-cells mostly expressed very little perforin and granulysin but contained granzymes A and B or lacked all these cytotoxic markers in TB and LTBI subjects, respectively. However, in vitro expanded Mtb-specific CD8 T-cells acquired perforin, granulysin and granzymes. Finally, Mtb-specific CD8 T-cell responses were more robust and prone to proliferate in patients with extrapulmonary compared to pulmonary TB. Conclusions: The clinical status and TB presentation are associated to specific profiles of Mtb-specific CD8 T-cell responses, thus indicating distinct dynamics between the mycobacteria, the CD8 T-cell response and the clinical outcome. Our data shed light on the controversial reached by studies performed in human and animal models, thus advancing the current knowledge on the complex dynamic of TB immunity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Depth profiles were sampled at different locations throughout Lake Geneva on a monthly and seasonal basis over the course of 2 years and analysed for their stable hydrogen and oxygen isotope compositions. The isotopic compositions indicate an isotopic stratification in the metalimnion during summer and fall. This is related to mixing of Rhône River water, which in summer is dominated by snow and glacier melt waters, and lake water, with the latter having a homogenous isotopic composition. The observed interflow layer is 7-15 m thick and can be traced by the distinct stable isotope composition of the water for about 55 km throughout the lake as well as into shallow bay regions. Depth of the interflow layer close to the Rhône River mouth is similar to those previously described based on echo-soundings and turbidity profiles of sediment dispersion. In contrast to previous descriptions of the interflow within Lake Geneva, the stable isotope compositions allow for direct, natural tracing of the Rhône River water even in cases where the turbidity and conductivity measurements do not indicate such an interflow. In addition, the method allows for a quantification of the Rhône River and lake water in the interflow with the fraction of Rhône River water within the interflow estimated to be up to 37% in summer. The isotopic composition further indicates different vertical mixing processes within the two lake basins of Lake Geneva, related to the density gradients and local stability within the water column. The method may be applicable to other lakes in catchments with large differences in the topography as water that originates from high altitudes or glaciers has a distinct oxygen and hydrogen isotope composition compared to other sources of water originating at lower altitudes and/or from direct precipitation over the lake. Stable isotope measurements thus improve the understanding of the circulation of water within the lake, which is fundamental for an evaluation of the water residence times, dissolved pollutant and nutrient transport as well as oxygenation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Nucleoside reverse transcriptase inhibitors (NRTIs) are often administered in salvage therapy even if genotypic resistance tests (GRTs) indicate high-level resistance, but little is known about the benefit of these additional NRTIs. METHODS: The effect of <2 compared with 2 NRTIs on viral suppression (HIV-1 RNA < 50 copies/mL) at week 24 was studied in salvage patients receiving raltegravir. Intent-to-treat and per-protocol analyses were performed; last observation carried forward imputation was used to deal with missing information. Logistic regressions were weighted to create a pseudopopulation in which the probability of receiving <2 and 2 NRTIs was unrelated to baseline factors predicting treatment response. RESULTS: One-hundred thirty patients were included, of whom 58.5% (n = 76) received <2 NRTIs. NRTIs were often replaced by other drug classes. Patients with 2 NRTIs received less additional drug classes compared with patients with <2 NRTIs [median (IQR): 1 (1-2) compared with 2 (1-2), P Wilcoxon < 0.001]. The activity of non-NRTI treatment components was lower in the 2 NRTIs group compared with the <2 NRTIs group [median (IQR) genotypic sensitivity score: 2 (1.5-2.5) compared with 2.5 (2-3), P Wilcoxon < 0.001]. The administration of <2 NRTIs was associated with a worse viral suppression rate at week 24. The odds ratios were 0.34 (95% confidence interval: 0.13 to 0.89, P = 0.027) and 0.19 (95% confidence interval: 0.05 to 0.79, P = 0.023) when performing the last observation carried forward and the per-protocol approach, respectively. CONCLUSIONS: Our findings showed that partially active or inactive NRTIs contribute to treatment response, and thus the use of 2 NRTIs in salvage regimens that include raltegravir seems warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A preparation of organic working standards for the online measurement of C-13/C-12 and O-18/O-16 ratios in biological material is presented. The organic working standards are simple and inexpensive C-3 and C-4 carbohydrates ( sugars or cellulose) from distinct geographic origin, including white sugar, toilet and XEROX papers from Switzerland, maize from Ivory Coast, cane sugar from Brazil, papyrus from Egypt, and the core of the stem of a Cyperus papyrus plant from Kenya. These photosynthetic products were compared with International Atomic Energy standards CH-3 and CH-6 and other calibration materials. The presented working standards cover a 15 parts per thousand range of C-13/C-12 ratios and 9 parts per thousand for O-18/O-16, with a precision < +/- 0.2 parts per thousand for n > 10.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Active personal dosemeters (APD) have been found to be very efficient tools to reduce occupational doses in many applications of ionizing radiation. In order to be used in interventional radiology and cardiology (IR/IC), APDs should be able to measure low energy photons and pulsed radiation with relatively high instantaneous personal dose equivalent rates. A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Program. In particular, eight commercial APDs were tested in continuous and pulsed X-ray fields delivered by calibration laboratories in order to evaluate their performances. Most of APDs provide a response in pulsed mode more or less affected by the personal dose equivalent rate, which means they could be used in routine monitoring provided that correction factors are introduced. These results emphasize the importance of adding tests in pulsed mode in type-test procedures for APDs. Some general recommendations are proposed in the end of this paper for the selection and use of APDs at IR/IC workplaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new and original variational framework for atlas-based segmentation. The proposed framework integrates both the active contour framework, and the dense deformation fields of optical flow framework. This framework is quite general and encompasses many of the state-of-the-art atlas-based segmentation methods. It also allows to perform the registration of atlas and target images based on only selected structures of interest. The versatility and potentiality of the proposed framework are demonstrated by presenting three diverse applications: In the first application, we show how the proposed framework can be used to simulate the growth of inconsistent structures like a tumor in an atlas. In the second application, we estimate the position of nonvisible brain structures based on the surrounding structures and validate the results by comparing with other methods. In the final application, we present the segmentation of lymph nodes in the Head and Neck CT images, and demonstrate how multiple registration forces can be used in this framework in an hierarchical manner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, zinc indium tin oxide layers with different compositions are used as the active layer of thin film transistors. This multicomponent transparent conductive oxide is gaining great interest due to its reduced content of the scarce indium element. Experimental data indicate that the incorporation of zinc promotes the creation of oxygen vacancies. In thin-film transistors this effect leads to a higher threshold voltage values. The field-effect mobility is also strongly degraded, probably due to coulomb scattering by ionized defects. A post deposition annealing in air reduces the density of oxygen vacancies and improves the fieldeffect mobility by orders of magnitude. Finally, the electrical characteristics of the fabricated thin-film transistors have been analyzed to estimate the density of states in the gap of the active layers. These measurements reveal a clear peak located at 0.3 eV from the conduction band edge that could be attributed to oxygen vacancies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed at determining the dissolved oxygen consumption rate of Litopenaeus vannamei juveniles maintained in a microbial biofloc raceway system at high density with no aeration. Three 4 L bottles were filled for each treatment, sealed hermetically, and placed in an enclosed greenhouse raceway system. Four shrimp (13.2±1.42 g) were assigned to two sets of the bottles, which underwent the following treatments: light conditions with no shrimp; dark conditions with no shrimp; light conditions with shrimp; and dark conditions with shrimp. Dissolved oxygen content was measured every 10 min for 30 min. A quadratic behavior was observed in dissolved oxygen concentration over time. Significant differences for oxigen consumption were observed only at 10 and 20 min between shrimp maintained in the dark and those under light conditions. At 10 min, a higher value was observed in shrimp maintained under light, and at 20 min, in the dark. Significant differences between 10 and 20 min and between 10 and 30 min were observed when oxygen consumption was analyzed over time in the presence of light. Under dark conditions there were significant differences only between 20 and 30 min. Lethal oxygen concentration (0.65 mg L-1) would be reached in less than one hour either under light or dark conditions with no aeration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We tested the performance of transcutaneous oxygen monitoring (TcPO2) and pulse oximetry (tcSaO2) in detecting hypoxia in critically ill neonatal and pediatric patients. In 54 patients (178 data sets) with a mean age of 2.4 years (range 1 to 19 years), arterial saturation (SaO2) ranged from 9.5 to 100%, and arterial oxygen tension (PaO2) from 16.4 to 128 mmHg. Linear correlation analysis of pulse oximetry vs measured SaO2 revealed an r value of 0.95 (p less than 0.001) with an equation of y = 21.1 + 0.749x, while PaO2 vs tcPO2 showed a correlation coefficient of r = 0.95 (p less than 0.001) with an equation of y = -1.04 + 0.876x. The mean difference between measured SaO2 and tcSaO2 was -2.74 +/- 7.69% (range +14 to - 29%) and the mean difference between PaO2 and tcPO2 was +7.43 +/- 8.57 mmHg (range -14 to +49 mmHg). Pulse oximetry was reliable at values above 65%, but was inaccurate and overestimated the arterial SaO2 at lower values. TcPO2 tended to underestimate the arterial value with increasing PaO2. Pulse oximetry had the best sensitivity to specificity ratio for hypoxia between 65 and 90% SaO2; for tcPO2 the best results were obtained between 35 and 55 mmHg PaO2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is known that post-movement beta synchronization (PMBS) is involved both in active inhibition and in sensory reafferences processes. The aim of this study was examine the temporal and spatial dynamics of the PMBS involved during multi-limb coordination task. We investigated post-switching beta synchronization (assigned PMBS) using time-frequency and source estimations analyzes. Participants (n = 17) initiated an auditory-paced bimanual tapping. After a 1500 ms preparatory period, an imperative stimulus required to either selectively stop the left while maintaining the right unimanual tapping (Switch condition: SWIT) or to continue the bimanual tapping (Continue condition: CONT). PMBS significantly increased in SWIT compared to CONT with maximal difference within right central region in broad-band 14âeuro"30 Hz and within left central region in restricted-band 22âeuro"26 Hz. Source estimations localized these effects within right pre-frontal cortex and left parietal cortex, respectively. A negative correlation showed that participants with a low percentage of errors in SWIT had a large PMBS amplitude within right parietal and frontal cortices. This study shows for the first time simultaneous PMBS with distinct functions in different brain regions and frequency ranges. The left parietal PMBS restricted to 22âeuro"26 Hz could reflect the sensory reafferences of the right hand tapping disrupted by the switching. In contrast, the right pre-frontal PMBS in a broad-band 14âeuro"30 Hz is likely reflecting the active inhibition of the left hand stopped. Finally, correlations between behavioral performance and the magnitude of the PMBS suggest that beta oscillations can be viewed as a marker of successful active inhibition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to compare oxygen uptake (  V˙O2), hormone and plasma metabolite responses during the 30 min after submaximal incremental exercise (Incr) performed at the same relative/absolute exercise intensity and duration in lean (L) and obese (O) men. Eight L and 8 O men (BMI: 22.9±0.4; 37.2±1.8 kg · m(-2)) completed Incr and were then seated for 30 min.   V˙O2 was monitored during the first 10 min and from the 25-30(th) minutes of recovery. Blood samples were drawn for the determination of hormone (catecholamines, insulin) and plasma metabolite (NEFA, glycerol) concentrations. Excess post-exercise oxygen consumption (EPOC) magnitude during the first 10 min was similar in O and in L (3.5±0.4; 3.4±0.3 liters, respectively, p=0.86). When normalized to percent change (  V˙O2END=100%), %   V˙O2END during recovery was significantly higher from 90-120 s in O than in L (p≤0.04). There were no significant differences in catecholamines (p≥0.24), whereas insulin was significantly higher in O than in L during recovery (p=0.01). The time-course of glycerol was similar from 10-30 min of recovery (-42% for L; -41% for O, p=0.85), whereas significantly different patterns of NEFA were found from 10-30 min of recovery between groups (-18% for L; +8% for O, p=0.03). Despite similar EPOC, a difference in   V˙O2 modulation between groups was observed, likely due to faster initial rates of   V˙O2 decline in L than in O. The different patterns of NEFA between groups may suggest a lower NEFA reesterification during recovery in O, which was not involved in the rapid EPOC component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

White adipose tissue (WAT) produces lactate in significant amount from circulating glucose, especially in obesity;Under normoxia, 3T3L1 cells secrete large quantities of lactate to the medium, again at the expense of glucose and proportionally to its levels. Most of the glucose was converted to lactate with only part of it being used to synthesize fat. Cultured adipocytes were largely anaerobic, but this was not a Warburg-like process. It is speculated that the massive production of lactate, is a process of defense of the adipocyte, used to dispose of excess glucose. This way, the adipocyte exports glucose carbon (and reduces the problem of excess substrate availability) to the liver, but the process may be also a mechanism of short-term control of hyperglycemia. The in vivo data obtained from adipose tissue of male rats agree with this interpretation.