913 resultados para ASSISTED RESECTION
Resumo:
BACKGROUND: Theodor Kocher, surgeon and Nobel laureate, has influenced thyroid surgery all over the world: his treatment for multinodular goiter-subtotal thyroidectomy-has been the "Gold Standard" for more than a century. However, based on a new understanding of molecular growth mechanisms in goitrogenesis, we set out to evaluate if a more extended resection yields better results. METHODS: Four thousand three hundred and ninety-four thyroid gland operations with 5,785 "nerves at risk" were prospectively analyzed between 1972 and 2002. From 1972 to 1990, the limited Kocher resections were performed, and from 1991 to 2002 a more radical resection involving at least a hemithyroidectomy was performed. RESULTS: The incidence of postoperative nerve palsy was 3.6%; in the first study period and 0.9%; in the second (P < 0.001, Fisher's exact). Postoperative hypoparathyroidism decreased from 3.2%; in the first period to 0.64%; in the second (P < 0.01). The rate of reoperation for recurrent disease was 11.1%; from 1972 to 1990 and 8.5%; from 1991 to 2002 (P < 0.01). CONCLUSIONS: Extended resection for multinodular goiter not only significantly reduced morbidity, but also decreased the incidence of operations for recurrent disease. Our findings in a large cohort corroborate the suggestions that Kocher's approach should be replaced by a more radical resection, which actually was his original intention more than 130 years ago.
Resumo:
A novel computer-assisted injection device for the delivery of highly viscous bone cements in vertebroplasty is presented. It addresses the shortcomings of manual injection systems ranging from low-pressure and poor level of control to device failure. The presented instrument is capable of generating a maximum pressure of 5000 kPa in traditional 6-ml syringes and provides an advanced control interface for precise cement delivery from outside radiation fields emitted by intraoperative imaging systems. The integrated real-time monitoring of injection parameters, such as flow-rate, volume, pressure, and viscosity, simplifies consistent documentation of interventions and establishes a basis for the identification of safe injection protocols on the longer term. Control algorithms prevent device failure due to overloading and provide means to immediately stop cement flow to avoid leakage into adjacent tissues.
Resumo:
OBJECTIVES: Residual airspace following thoracic resections is a common clinical problem. Persistent air leak, prolonged drainage time, and reduced hemostasis extend hospital stay and morbidity. We report a trial of pharmacologic-induced diaphragmatic paralysis through continuous paraphrenic injection of lidocaine to reduced residual airspace. The objectives were confirmation of diaphragmatic paralysis and possible procedure related complications. METHODS: Six eligible patients undergoing resectional surgery (lobectomy or bilobectomy) were included. Inclusion criteria consisted of: postoperative predicted FEV1 greater than 1300 ml, right-sided resection, absence of parenchymal lung disease, no class III antiarrhythmic therapy, absence of hypersensitivity reactions to lidocaine, no signs of infection, and informed consent. Upon completion of resection an epidural catheter was attached in the periphrenic tissue on the proximal pericardial surface, externalized through a separate parasternal incision, and connected to a perfusing system injecting lidocaine 1% at a rate of 3 ml/h (30 mg/h). Postoperative ICU surveillance for 24h and daily measurement of vital signs, drainage output, and bedside spirometry were performed. Within 48 h fluoroscopic confirmation of diaphragmatic paralysis was obtained. The catheter removal coincided with the chest tube removal when no procedural related complications occurred. RESULTS: None of the patients reported respiratory impairment. Diaphragmatic paralysis was documented in all patients. Upon removal of catheter or discontinuation of lidocaine prompt return of diaphragmatic motility was noticed. Two patients showed postoperative hemodynamic irrelevant atrial fibrillation. CONCLUSION: Postoperative paraphrenic catheter administration of lidocaine to ensure reversible diaphragmatic paralysis is safe and reproducible. Further studies have to assess a benefit in terms of reduction in morbidity, drainage time, and hospital stay, and determine the patients who will profit.
Resumo:
The aim of this study was to determine the influence of comorbidity on outcome after pulmonary resection in patients over 75 years old. Three hundred and thirty-three patients with non-small-cell lung cancer operated on between 1998 and 2002 were divided into 3 age groups: < 60 years (group 1), 60-75 years (group 2), > 75 years (group 3). Overall operative mortality was 0.3%; 30-day mortality was 1%. There were more major complications with re-operation in groups 1 and 2, but minor complications occurred significantly more frequently in group 3 (36% vs 16%). Overall mean hospital stay was 12 days, with no significant difference among groups. Three-year survival rates were: 80%, 70%, and 65% in groups 1, 2, and 3, respectively, with no significant difference among groups. Age or the presence of comorbidity should not be considered contraindications for lung resection. With proper patient selection and careful preoperative evaluation, many major complications after pneumonectomy are avoidable.
Resumo:
Postoperative infections and cardiac events are the major morbidity factors after thoracic surgery and dominating causes of death. Therefore, a sensitive blood marker is needed for an early diagnosis of complications. Twenty-two patients admitted with lung cancer were enrolled in this study. Procalcitonin, brain natriuretic peptide, C-reactive peptide and interleukin-6 levels were recorded preoperatively and postoperatively on days 1-5. Laboratory values of patients with cardiac or infectious complications were compared to patients without complications. During postoperative course procalcitonin and brain natriuretic peptide levels elevated in all patients, but both had higher peak levels in patients with infectious or cardiac complication than without these complications. Interleukin-6 levels were increased on day one and showed a slower decrease in case of complications than without complications. In general, brain natriuretic peptide and procalcitonin levels are increased in the postoperative course after major pulmonary resection, but cardiac and infectious complications are associated with higher levels and a slower decrease than without complications. Interleukin-6 levels showed a slower decrease in patients with complications in the postoperative course than without complications. So the combination of procalcitonin, brain natriuretic peptide, and interleukin-6 seems to be useful for an optimized postoperative monitoring.
Resumo:
HLA-G is a non-classical MHC class Ib molecule predominantly expressed in cytotrophoblasts and under pathological conditions also in chronically inflamed and in malignant tissues. Recently an increased expression of HLA-G was found in ulcerative colitis (UC), but not in Crohn's disease (CD). The HLA-G gene is located in IBD3, a linkage region for inflammatory bowel disease (IBD). A 14-bp deletion polymorphism (Del+/Del-) within exon 8 of the HLA-G gene might influence transcription activity and is therefore of potential functional relevance. To investigate whether the 14-bp deletion polymorphism is associated with IBD, 371 patients with CD, 257 patients with UC and 739 controls were genotyped. The heterozygous genotype (P = 0.031) and the Del+ phenotype (P = 0.038) were significantly increased, whereas the homozygous Del- phenotype (P = 0.038) was significantly decreased in UC when compared with CD. Thus, the 14-bp deletion polymorphism within the HLA-G gene displayed significant differences between UC and CD. Moreover, a significant increase of the Del+ allele (P = 0.002) and the Del+/Del+ genotype (P = 0.013) and a consecutive decrease of the Del-/- genotype (P = 0.024) were observed in those CD cases positive for ileocecal resection. Thus, a potential effect of the HLA-G gene in IBD may affect both UC and CD. Other polymorphisms linked to the 14-bp deletion polymorphism might also contribute to immunopathogenesis. As there are several partly functional polymorphisms within the promoter region potentially influencing HLA-G expression, further studies in IBD are necessary in the context of differential expression of HLA-G between UC and CD.
Resumo:
BACKGROUND AND PURPOSE: Computer-assisted navigation is increasingly used in functional endoscopic sinus surgery (FESS) to prevent injury to vital structures, necessitating preparative CT and, thus, radiation exposure. The purpose of our study was to investigate currently used radiation doses for CT in computer-assisted navigation in sinus surgery (CAS-CT) and to assess minimal doses required. MATERIALS AND METHODS: A questionnaire inquiring about dose parameters used for CAS-CT was sent to 30 radiologic institutions. The feasibility of low-dose registration was tested with a phantom. The influence of CAS-CT dose on technical accuracy and on the practical performance of 5 ear, nose, and throat (ENT) surgeons was evaluated with cadaver heads. RESULTS: The questionnaire response rate was 63%. Variation between minimal and maximal dose used for CAS-CT was 18-fold. Phantom registration was possible with doses as low as 1.1 mGy. No dose dependence on technical accuracy was found. ENT surgeons were able to identify anatomic landmarks on scans with a dose as low as 3.1 mGy. CONCLUSIONS: The vast dose difference between institutions mirrors different attitudes toward image quality and radiation-protection issues rather than being technically founded, and many patients undergo CAS-CT at higher doses than necessary. The only limit for dose reduction in CT for computer-assisted endoscopic sinus surgery is the ENT surgeon's ability to cope with impaired image quality, whereas there is no technically justified lower dose limit. We recommend, generally, doses used for the typical diagnostic low-dose sinus CT (120 kV/20-50 mAs). When no diagnostic image quality is needed, even a reduction down to a third is possible.
Resumo:
New designs of user input systems have resulted from the developing technologies and specialized user demands. Conventional keyboard and mouse input devices still dominate the input speed, but other input mechanisms are demanded in special application scenarios. Touch screen and stylus input methods have been widely adopted by PDAs and smartphones. Reduced keypads are necessary for mobile phones. A new design trend is exploring the design space in applications requiring single-handed input, even with eyes-free on small mobile devices. This requires as few keys on the input device to make it feasible to operate. But representing many characters with fewer keys can make the input ambiguous. Accelerometers embedded in mobile devices provide opportunities to combine device movements with keys for input signal disambiguation. Recent research has explored its design space for text input. In this dissertation an accelerometer assisted single key positioning input system is developed. It utilizes input device tilt directions as input signals and maps their sequences to output characters and functions. A generic positioning model is developed as guidelines for designing positioning input systems. A calculator prototype and a text input prototype on the 4+1 (5 positions) positioning input system and the 8+1 (9 positions) positioning input system are implemented using accelerometer readings on a smartphone. Users use one physical key to operate and feedbacks are audible. Controlled experiments are conducted to evaluate the feasibility, learnability, and design space of the accelerometer assisted single key positioning input system. This research can provide inspiration and innovational references for researchers and practitioners in the positioning user input designs, applications of accelerometer readings, and new development of standard machine readable sign languages.
Resumo:
OBJECTIVE: The purpose of this study was to evaluate, in relation to intraoperative estimated blood loss (EBL), the effectiveness of preoperative transcatheter arterial embolization of hypervascular osseous metastatic lesions before orthopedic resection and stabilization. MATERIALS AND METHODS: Between June 1987 and November 2007, 22 patients underwent transcatheter arterial embolization of tumors of the long bone, hip, or vertebrae before resection and stabilization. Osseous metastatic lesions from renal cell carcinoma, malignant melanoma, leiomyosarcoma, and prostate cancer were embolized. All patients were treated with a coaxial catheter technique with polyvinyl alcohol (PVA) particles alone or a combination of PVA particles and coils. After embolization, each tumor was angiographically graded according to devascularization (grades 1-3) based on tumor blush after contrast injection into the main tumor-feeding arteries. RESULTS: In patients with complete devascularization (grade 1), mean EBL was calculated to be 1,119 mL, whereas in patients with partial embolization (grades 2 and 3) EBL was 1,788 mL and 2,500 mL. With respect to intraoperative EBL, no significant difference between devascularization grades was found (p > 0.05). Moderate correlation (r = 0.51, p = 0.019) was observed between intraoperative EBL and tumor size before embolization. Only low correlation (r = 0.44, p = 0.046) was found between intraoperative EBL and operating time. Major complications included transient palsy of the sciatic nerve and gluteal abscess in one patient. CONCLUSION: The results of this study support the concept that there is no statistically significant difference among amounts of intraoperative EBL with varying degrees of embolization.
Resumo:
LiFePO4 is a Co-free battery material. Its advantages of low cost, non-toxic and flat discharge plateau show promising for vehicle propulsion applications. A major problem associated with this material is its low electrical conductivity. Use of nanosized LiFePO4 coated with carbon is considered a solution because the nanosized particles have much shorter path for L+ ions to travel from the LiFePO4 crystal lattice to electrolytes. As other nano material powders, however, nano LiFePO4 could have processing and health issues. In order to achieve high electrical conductivity while maintaining a satisfactory manufacturability, the particles should possess both of the nano- and the microcharacteristics correspondingly. These two contradictory requirements could only be fulfilled if the LiFePO4 powders have a hierarchical structure: micron-sized parent particles assembled by nanosized crystallites with appropriate electrolyte communication channels. This study addressed the issue by study of the formation and development mechanisms of the LiFePO4 crystallites and their microstructures. Microwaveassisted wet chemical (MAWC) synthesis approach was employed in order to facilitate the evolvement of the nanostructures. The results reveal that the LiFePO4 crystallites were directly nucleated from amorphous precursors by competition against other low temperature phases, Li3PO4 and Fe3(PO4)2•8H2O. Growth of the crystalline LiFePO4 particles went through oriented attachment first, followed by revised Ostwald ripening and then recrystallization. While recrystallization played the role in growth of well crystallized particles, oriented attachment and revised Ostwald ripening were responsible for formation of the straight edge and plate-like shaped LiFePO4 particles comprised of nanoscale substructure. Oriented attachment and revised Ostwald ripening seemed to be also responsible for clustering the plate-like LiFePO4 particles into a high-level aggregated structure. The finding from this study indicates a hope for obtaining the hierarchical structure of LiFePO4 particles that could exhibit the both micro- and nano- scale characteristics. Future study is proposed to further advance the understanding of the structural development mechanisms, so that they can be manipulated for new LiFePO4 structures ideal for battery application.
Resumo:
Fastener grade steels with varying alloy contents and heat treatments were employed to measure changes in resistance to hydrogen assisted cracking. The testing procedure compared notched tension specimens fractured in air to threshold stress values obtained during hydrogen charging, utilizing a rising step load procedure. Bainitic structures improved resistance by 10-20% compared to tempered martensite structures. Dual phase steels with a tempered martensite matrix and 20% ferrite were more susceptible and notch sensitive. High strength, fully pearlitic structures showed an improvement in resistance. Carbon content, per se, had no effect on the resistance of steel to hydrogen assisted cracking. Chromium caused a deleterious effect but all other alloying elements studied did not cause much change in hydrogen assisted cracking susceptibility.