837 resultados para ARTHROPLASTY, REPLACEMENT, KNEE
Resumo:
Glycogen storage disease type II is a rare multi-systemic disorder characterised by an intracellular accumulation of glycogen due a mutation in the acid alpha glucosidase (GAA) gene. The level of residual enzyme activity, the genotype and other yet unknown factors account for the broad variation of the clinical phenotype. The classical infantile form is characterised by severe muscle hypotonia and cardiomyopathy leading to early death. The late-onset form presents as a limb girdle myopathy with or without pulmonary dysfunction. Enzyme replacement therapy (ERT) with recombinant human GAA (rhGAA) in infants is life saving. In contrast, therapeutic efficacy of rhGAA in the late-onset form is modest. High expenses of rhGAA, on-going infusions and poor pharmacokinetic efficacy raised a discussion of the cost effectiveness of ERT in late-onset Pompe disease in Switzerland. This discussion was triggered by a Swiss federal court ruling which confirmed the reluctance of a health care insurer not to reimburse treatment costs in a 67-year-old female suffering from Pompe disease. As a consequence of this judgement ERT was stopped by all insurance companies in late-onset Pompe patients in Switzerland regardless of their clinical condition. Subsequent negotiations lead to the release of a national guideline of the management of late-onset Pompe disease. Initiation and limitation of ERT is outlined in a national Pompe registry. Reimbursement criteria are defined and individual efficacy of ERT with rhGAA is continuously monitored.
Resumo:
Chronic osteoarthritis of the metacarpophalangeal joint is predominantly observed in working dogs. Surgical intervention is often required to maintain a functional limb. Excision arthroplasty represents a simple, relatively quick and cosmetically esthetic alternative to arthrodesis, endoprosthesis or amputation. In the present study, the technique of excision arthroplasty is described and discussed as a treatment method for chronic osteoarthritis of the metacarpophalangeal joint.
Resumo:
OBJECTIVES: Proteomics approaches to cardiovascular biology and disease hold the promise of identifying specific proteins and peptides or modification thereof to assist in the identification of novel biomarkers. METHOD: By using surface-enhanced laser desorption and ionization time of flight mass spectroscopy (SELDI-TOF-MS) serum peptide and protein patterns were detected enabling to discriminate between postmenopausal women with and without hormone replacement therapy (HRT). RESULTS: Serum of 13 HRT and 27 control subjects was analyzed and 42 peptides and proteins could be tentatively identified based on their molecular weight and binding characteristics on the chip surface. By using decision tree-based Biomarker Patternstrade mark Software classification and regression analysis a discriminatory function was developed allowing to distinguish between HRT women and controls correctly and, thus, yielding a sensitivity of 100% and a specificity of 100%. The results show that peptide and protein patterns have the potential to deliver novel biomarkers as well as pinpointing targets for improved treatment. The biomarkers obtained represent a promising tool to discriminate between HRT users and non-users. CONCLUSION: According to a tentative identification of the markers by their molecular weight and binding characteristics, most of them appear to be part of the inflammation induced acute-phase response
Resumo:
BACKGROUND Osteoarthritis is the most common form of joint disease and the leading cause of pain and physical disability in older people. Opioids may be a viable treatment option if people have severe pain or if other analgesics are contraindicated. However, the evidence about their effectiveness and safety is contradictory. This is an update of a Cochrane review first published in 2009. OBJECTIVES To determine the effects on pain, function, safety, and addiction of oral or transdermal opioids compared with placebo or no intervention in people with knee or hip osteoarthritis. SEARCH METHODS We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE and CINAHL (up to 28 July 2008, with an update performed on 15 August 2012), checked conference proceedings, reference lists, and contacted authors. SELECTION CRITERIA We included randomised or quasi-randomised controlled trials that compared oral or transdermal opioids with placebo or no treatment in people with knee or hip osteoarthritis. We excluded studies of tramadol. We applied no language restrictions. DATA COLLECTION AND ANALYSIS We extracted data in duplicate. We calculated standardised mean differences (SMDs) and 95% confidence intervals (CI) for pain and function, and risk ratios for safety outcomes. We combined trials using an inverse-variance random-effects meta-analysis. MAIN RESULTS We identified 12 additional trials and included 22 trials with 8275 participants in this update. Oral oxycodone was studied in 10 trials, transdermal buprenorphine and oral tapentadol in four, oral codeine in three, oral morphine and oral oxymorphone in two, and transdermal fentanyl and oral hydromorphone in one trial each. All trials were described as double-blind, but the risk of bias for other domains was unclear in several trials due to incomplete reporting. Opioids were more beneficial in pain reduction than control interventions (SMD -0.28, 95% CI -0.35 to -0.20), which corresponds to a difference in pain scores of 0.7 cm on a 10-cm visual analogue scale (VAS) between opioids and placebo. This corresponds to a difference in improvement of 12% (95% CI 9% to 15%) between opioids (41% mean improvement from baseline) and placebo (29% mean improvement from baseline), which translates into a number needed to treat (NNTB) to cause one additional treatment response on pain of 10 (95% CI 8 to 14). Improvement of function was larger in opioid-treated participants compared with control groups (SMD -0.26, 95% CI -0.35 to -0.17), which corresponds to a difference in function scores of 0.6 units between opioids and placebo on a standardised Western Ontario and McMaster Universities Arthritis Index (WOMAC) disability scale ranging from 0 to 10. This corresponds to a difference in improvement of 11% (95% CI 7% to 14%) between opioids (32% mean improvement from baseline) and placebo (21% mean improvement from baseline), which translates into an NNTB to cause one additional treatment response on function of 11 (95% CI 7 to 14). We did not find substantial differences in effects according to type of opioid, analgesic potency, route of administration, daily dose, methodological quality of trials, and type of funding. Trials with treatment durations of four weeks or less showed larger pain relief than trials with longer treatment duration (P value for interaction = 0.001) and there was evidence for funnel plot asymmetry (P value = 0.054 for pain and P value = 0.011 for function). Adverse events were more frequent in participants receiving opioids compared with control. The pooled risk ratio was 1.49 (95% CI 1.35 to 1.63) for any adverse event (9 trials; 22% of participants in opioid and 15% of participants in control treatment experienced side effects), 3.76 (95% CI 2.93 to 4.82) for drop-outs due to adverse events (19 trials; 6.4% of participants in opioid and 1.7% of participants in control treatment dropped out due to adverse events), and 3.35 (95% CI 0.83 to 13.56) for serious adverse events (2 trials; 1.3% of participants in opioid and 0.4% of participants in control treatment experienced serious adverse events). Withdrawal symptoms occurred more often in opioid compared with control treatment (odds ratio (OR) 2.76, 95% CI 2.02 to 3.77; 3 trials; 2.4% of participants in opioid and 0.9% of participants control treatment experienced withdrawal symptoms). AUTHORS' CONCLUSIONS The small mean benefit of non-tramadol opioids are contrasted by significant increases in the risk of adverse events. For the pain outcome in particular, observed effects were of questionable clinical relevance since the 95% CI did not include the minimal clinically important difference of 0.37 SMDs, which corresponds to 0.9 cm on a 10-cm VAS.
Resumo:
BACKGROUND Knee pain is associated with radiographic knee osteoarthritis, but the relationships between physical examination, pain and radiographic features are unclear. OBJECTIVE To examine whether deficits in knee extension or flexion were associated with radiographic severity and pain during clinical examination in persons with knee pain or radiographic features of osteoarthritis. DESIGN Cross-sectional data of the Somerset and Avon Survey of Health (SASH) cohort study. METHODS Participants with knee pain or radiographic features of osteoarthritis were included. We assessed the range of passive knee flexion and extension, pain on movement and Kellgren and Lawrence (K/L) grades. Odds ratios were calculated for the association between range of motion and pain as well as radiographic severity. RESULTS/FINDINGS Of 1117 participants with a clinical assessment, 805 participants and 1530 knees had complete data and were used for this analysis. Pain and radiographic changes were associated with limited range of motion. In knees with pain on passive movement, extension and flexion were reduced per one grade of K/L by -1.4° (95% CI -2.2 to -0.5) and -1.6° (95% CI -2.8 to -0.4), while in knees without pain the reduction was -0.3° (95% CI -0.6 to -0.1) (extension) and -1.1° (-1.8 to -0.3) (flexion). The interaction of pain with K/L was significant (p = 0.021) for extension but not for flexion (p = 0.333). CONCLUSIONS Pain during passive movement, which may be an indicator of reversible soft-tissue changes, e.g., reversible through physical therapy, is independently associated with reduced flexion and extension of the knee.
Resumo:
Aims: We sought to analyse local distribution of aortic annulus and left ventricular outflow tract (LVOT) calcification in patients undergoing transcatheter aortic valve replacement (TAVR) and its impact on aortic regurgitation (AR) immediately after device placement. Methods and results: A group of 177 patients with severe aortic stenosis undergoing multislice computed tomography of the aortic root followed by TAVR were enrolled in this single-centre study. Annular and LVOT calcifications were assessed per cusp using a semi-quantitative grading system (0: none; 1 [mild]: small, non-protruding calcifications; 2 [moderate]: protruding [>1 mm] or extensive [>50% of cusp sector] calcifications; 3 [severe]: protruding and extensive calcifications). Any calcification of the annulus or LVOT was present in 107 (61%) and 63 (36%) patients, respectively. Prevalence of annulus/LVOT calcifications in the left coronary cusp was 42% and 25%, respectively, in the non-coronary cusp 28% and 13%, in the right coronary cusp 13% and 5%. AR grade 2 to 4 assessed by the method of Sellers immediately after TAVR device implantation was observed in 55 patients (31%). Multivariate regression analysis revealed that the overall annulus calcification (OR [95% CI] 1.48 [1.10-2.00]; p=0.0106), the overall LVOT calcification (1.93 [1.26-2.96]; p=0.0026), any moderate or severe LVOT calcification (5.37 [1.52-18.99]; p=0.0092), and asymmetric LVOT calcification were independent predictors of AR. Conclusions: Calcifications of the aortic annulus and LVOT are frequent in patients undergoing TAVR, and both the distribution and the severity of calcifications appear to be independent predictors of aortic regurgitation after device implantation. - See more at: http://www.pcronline.com/eurointervention/77th_issue/126/#sthash.Hzodgju5.dpuf
Resumo:
BACKGROUND Limited information exists describing the results of transcatheter aortic valve (TAV) replacement in patients with bicuspid aortic valve (BAV) disease (TAV-in-BAV). OBJECTIVES This study sought to evaluate clinical outcomes of a large cohort of patients undergoing TAV-in-BAV. METHODS We retrospectively collected baseline characteristics, procedural data, and clinical follow-up findings from 12 centers in Europe and Canada that had performed TAV-in-BAV. RESULTS A total of 139 patients underwent TAV-in-BAV with the balloon-expandable transcatheter heart valve (THV) (n = 48) or self-expandable THV (n = 91) systems. Patient mean age and Society of Thoracic Surgeons predicted risk of mortality scores were 78.0 ± 8.9 years and 4.9 ± 3.4%, respectively. BAV stenosis occurred in 65.5%, regurgitation in 0.7%, and mixed disease in 33.8% of patients. Incidence of type 0 BAV was 26.7%; type 1 BAV was 68.3%; and type 2 BAV was 5.0%. Multislice computed tomography (MSCT)-based TAV sizing was used in 63.5% of patients (77.1% balloon-expandable THV vs. 56.0% self-expandable THV, p = 0.02). Procedural mortality was 3.6%, with TAV embolization in 2.2% and conversion to surgery in 2.2%. The mean aortic gradient decreased from 48.7 ± 16.5 mm Hg to 11.4 ± 9.9 mm Hg (p < 0.0001). Post-implantation aortic regurgitation (AR) grade ≥2 occurred in 28.4% (19.6% balloon-expandable THV vs. 32.2% self-expandable THV, p = 0.11) but was prevalent in only 17.4% when MSCT-based TAV sizing was performed (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio [OR]: 0.19, 95% confidence intervals [CI]: 0.08 to 0.45; p < 0.0001). Thirty-day device safety, success, and efficacy were noted in 79.1%, 89.9%, and 84.9% of patients, respectively. One-year mortality was 17.5%. Major vascular complications were associated with increased 1-year mortality (OR: 5.66, 95% CI: 1.21 to 26.43; p = 0.03). CONCLUSIONS TAV-in-BAV is feasible with encouraging short- and intermediate-term clinical outcomes. Importantly, a high incidence of post-implantation AR is observed, which appears to be mitigated by MSCT-based TAV sizing. Given the suboptimal echocardiographic results, further study is required to evaluate long-term efficacy.
Resumo:
Background Concurrent cardiac diseases are frequent among elderly patients and invite simultaneous treatment to ensure an overall favourable patient outcome. Aim To investigate the feasibility of combined single-session percutaneous cardiac interventions in the era of transcatheter aortic valve implantation (TAVI). Methods This prospective, case–control study included 10 consecutive patients treated with TAVI, left atrial appendage occlusion and percutaneous coronary interventions. Some in addition had patent foramen ovale or atrial septal defect closure in the same session. The patients were matched in a 1:10 manner with TAVI-only cases treated within the same time period at the same institution regarding their baseline factors. The outcome was validated according to the Valve Academic Research Consortium (VARC) criteria. Results Procedural time (126±42 vs 83±40 min, p=0.0016), radiation time (34±8 vs 22±12 min, p=0.0001) and contrast dye (397±89 vs 250±105 mL, p<0.0001) were higher in the combined intervention group than in the TAVI-only group. Despite these drawbacks, no difference in the VARC endpoints was evident during the in-hospital period and after 30 days (VARC combined safety endpoint 32% for TAVI only and 20% for combined intervention, p=1.0). Conclusions Transcatheter treatment of combined cardiac diseases is feasible even in a single session in a high-volume centre with experienced operators.
Resumo:
BACKGROUND: Despite its limitations, citation analysis remains one of the best currently available tools for quantifying the impact of articles. Bibliometric studies list the "best-sellers" in a single location, and they have been published frequently in many fields during recent years. The purpose of the present study was to report the qualities and characteristics of citation classics in orthopaedic knee research. METHODS: The database of the Institute for Scientific Information (ISI) was utilized for identification of articles published from 1945 to March 2014. All knee articles that had been published in sixty-five orthopaedic and twenty-nine rheumatology journals and that had been cited at least 200 times were identified. The top 100 were selected for further analysis of authorship, source journal, number of citations, citation rate (both since publication and in 2013), geographic origin, article type, and level of evidence. RESULTS: The publication dates of the 100 most-cited articles ranged from 1948 to 2007, with the greatest number of articles published in the 1980s. Citations per article ranged from 2640 to 287. All articles were published in eleven of the ninety-four journals. The leading countries of origin were the U.S. followed by the U.K. and Sweden. The two main focus areas were sports traumatology and degenerative disease. The number of citations per article was also greatest for articles published in the 1980s. Basic research articles were cited more quickly, but not more often, than clinical articles. Most articles represented Level-IV evidence, followed by Levels II, III, and I. CONCLUSIONS: This bibliometric study is likely to include a list of intellectual milestones in orthopaedic knee research. It is apparent that a high level of evidence is not mandatory for an article to gain a large number of citations. Bibliometric reports provide a reflection of the quality of cited research published in a specific field and should therefore provoke thinking within the scientific community.
Resumo:
PURPOSE Fixation of anterior cruciate ligament (ACL) substitutes with non-physiological anteroposterior translation (APT) worsens outcome. The aim was to present a technique for physiological APT adjustment of the transplant in ACL reconstruction and its outcome at midterm. METHODS In a consecutive series of 28 patients (age 32 ± 11 years, 24 male), chronic ACL deficiency was treated by bone-patella-tendon-bone reconstruction. Transplant APT was adjusted to that of the contralateral uninjured ACL, measured 3, 6, and 12 months postoperatively using the Rolimeter. At a median follow-up of 5.3 years (3-8 years), 82% of the patients were re-evaluated with APT measurement and using IKDC-, Tegner-, Lysholm-Scores, conventional radiographs and MRI. RESULTS No differences in APT (mean ± SD) between uninjured and reconstructed knees were observed after adjustment (6 ± 1 versus 6 ± 1 mm, n.s.). Three months postoperatively, a statistically significant increase in APT (7 ± 1 mm) and a further increase at midterm (9 ± 2 mm) were observed. Patients scored "normal" or "nearly normal", respectively, in 79% (IKDC) and 4 (3-9) points (Tegner; median, range) or 89 ± 9 points (Lysholm; mean ± SD). Radiological evaluation showed no, minimal or moderate joint degeneration in 5, 20 and 75% of patients, respectively. MRI confirmed intact ACL transplants in all patients. CONCLUSION ACL reconstruction using the presented technique was considered successful, as patients did not suffer from subjective instability, radiographic analysis did not provide evidence for graft rupture at midterm. However, APT increase and occurrence of degenerative changes in reconstructed knees at the midterm might not be prevented even by restoration of a physiological APT in ACL reconstruction. The Rolimeter can be used for quick and easy intraoperative indirect control of the applied tension to the ACL transplant by measuring the APT to obtain physiological tensioning resulting in a satisfying outcome at midterm. LEVEL OF EVIDENCE IV.
Resumo:
OBJECTIVES To report the mid-term results of aortic root replacement using a self-assembled biological composite graft, consisting of a vascular tube graft and a stented tissue valve. METHODS Between January 2005 and December 2011, 201 consecutive patients [median age 66 (interquartile range, IQR, 55-77) years, 31 female patients (15.4%), median logistic EuroSCORE 10 (IQR 6.8-23.2)] underwent aortic root replacement using a stented tissue valve for the following indications: annulo-aortic ectasia or ascending aortic aneurysm with aortic valve disease in 162 (76.8%) patients, active infective endocarditis in 18 (9.0%) and acute aortic dissection Stanford type A in 21 (10.4%). All patients underwent clinical and echocardiographic follow-up. We analysed survival and valve-related events. RESULTS The overall in-hospital mortality rate was 4.5%. One- and 5-year cardiac-related mortality rates were 3 and 6%, and overall survival was 95 ± 1.5 and 75 ± 3.6%, respectively. The rate of freedom from structural valve failure was 99% and 97 ± 0.4% at the 1- and 5-year follow-up, respectively. The incidence rates of prosthetic valve endocarditis were 3 and 4%, respectively. During a median follow-up of 28 (IQR 14-51) months, only 2 (1%) patients required valve-related redo surgery due to prosthetic valvular endocarditis and none suffered from thromboembolic events. One percent of patients showed structural valve deterioration without any clinical symptoms; none of the patients suffered greater than mild aortic regurgitation. CONCLUSIONS Aortic root replacement using a self-assembled biological composite graft is an interesting option. Haemodynamic results are excellent, with freedom from structured valve failure. Need for reoperation is extremely low, but long-term results are necessary to prove the durability of this concept.
Resumo:
OBJECTIVES Valve-sparing root replacement (VSRR) is thought to reduce the rate of thromboembolic and bleeding events compared with aortic root replacement using a mechanical aortic root replacement (MRR) with a composite graft by avoiding oral anticoagulation. But as VSRR carries a certain risk for subsequent reinterventions, decision-making in the individual patient can be challenging. METHODS Of 100 Marfan syndrome (MFS) patients who underwent 169 aortic surgeries and were followed at our institution since 1995, 59 consecutive patients without a history of dissection or prior aortic surgery underwent elective VSRR or MRR and were retrospectively analysed. RESULTS VSRR was performed in 29 (David n = 24, Yacoub n = 5) and MRR in 30 patients. The mean age was 33 ± 15 years. The mean follow-up after VSRR was 6.5 ± 4 years (180 patient-years) compared with 8.8 ± 9 years (274 patient-years) after MRR. Reoperation rates after root remodelling (Yacoub) were significantly higher than after the reimplantation (David) procedure (60 vs 4.2%, P = 0.01). The need for reinterventions after the reimplantation procedure (0.8% per patient-year) was not significantly higher than after MRR (P = 0.44) but follow-up after VSRR was significantly shorter (P = 0.03). There was neither significant morbidity nor mortality associated with root reoperations. There were no neurological events after VSRR compared with four stroke/intracranial bleeding events in the MRR group (log-rank, P = 0.11), translating into an event rate of 1.46% per patient-year following MRR. CONCLUSION The calculated annual failure rate after VSRR using the reimplantation technique was lower than the annual risk for thromboembolic or bleeding events. Since the perioperative risk of reinterventions following VSRR is low, patients might benefit from VSRR even if redo surgery may become necessary during follow-up.
Resumo:
PURPOSE OF REVIEW There is controversy regarding the optimal choice of prosthetic valves in patients less than 65 years of age requiring mitral valve replacement (MVR). Recently, trends for valve replacement are moving towards biological prosthesis also in younger patients, which is justified by the fact that a later valve-in-valve procedure is feasible in the case of degeneration of the tissue valve. This strategy is increasingly recommended in aortic valve surgery but is questionable for MVR. The purpose of this review is to evaluate current guidelines and analyse evidence for biological MVR in patients under 65 years. RECENT FINDINGS There are differences between guidelines of the American Heart Association and those of the European Society of Cardiology concerning the choice of prostheses in patients undergoing MVR. Although the European Society of Cardiology recommends a mechanical mitral valve in patients under 65 years of age, the American Heart Association does not provide detailed advice for these patients. Mitral valve replacement with biological valves in patients under 65 years is associated with higher rates of reoperation due to structural valve deterioration. In addition, several studies showed a decreased survival after biological MVR. SUMMARY Evidence for biological MVR in patients less than 65 years without comorbidities or contraindication for oral anticoagulation does not exist. Recommendations for patients less than 65 years of age should not be blurred by current 'en-vogue' methods for promising but not yet proven valve-in-valve strategies.