995 resultados para ALL-CERAMIC RESTORATIONS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Filtration is a widely used unit operation in chemical engineering. The huge variation in the properties of materials to be ltered makes the study of ltration a challenging task. One of the objectives of this thesis was to show that conventional ltration theories are di cult to use when the system to be modelled contains all of the stages and features that are present in a complete solid/liquid separation process. Furthermore, most of the ltration theories require experimental work to be performed in order to obtain critical parameters required by the theoretical models. Creating a good overall understanding of how the variables a ect the nal product in ltration is somewhat impossible on a purely theoretical basis. The complexity of solid/liquid separation processes require experimental work and when tests are needed, it is advisable to use experimental design techniques so that the goals can be achieved. The statistical design of experiments provides the necessary tools for recognising the e ects of variables. It also helps to perform experimental work more economically. Design of experiments is a prerequisite for creating empirical models that can describe how the measured response is related to the changes in the values of the variable. A software package was developed that provides a ltration practitioner with experimental designs and calculates the parameters for linear regression models, along with the graphical representation of the responses. The developed software consists of two software modules. These modules are LTDoE and LTRead. The LTDoE module is used to create experimental designs for di erent lter types. The lter types considered in the software are automatic vertical pressure lter, double-sided vertical pressure lter, horizontal membrane lter press, vacuum belt lter and ceramic capillary action disc lter. It is also possible to create experimental designs for those cases where the variables are totally user de ned, say for a customized ltration cycle or di erent piece of equipment. The LTRead-module is used to read the experimental data gathered from the experiments, to analyse the data and to create models for each of the measured responses. Introducing the structure of the software more in detail and showing some of the practical applications is the main part of this thesis. This approach to the study of cake ltration processes, as presented in this thesis, has been shown to have good practical value when making ltration tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dewatering of iron ore concentrates requires large capacity in addition to producing a cake with low moisture content. Such large processes are commonly energy intensive and means to lower the specific energy consumption are needed. Ceramic capillary action disc filters incorporate a novel filter medium enabling the harnessing of capillary action, which results in decreased energy consumption in comparison to traditional filtration technologies. As another benefit, the filter medium is mechanically and chemically more durable than, for example, filter cloths and can, thus, withstand harsh operating conditions and possible regeneration better than other types of filter media. In iron ore dewatering, the regeneration of the filter medium is done through a combination of several techniques: (1) backwashing, (2) ultrasonic cleaning, and (3) acid regeneration. Although it is commonly acknowledged that the filter medium is affected by slurry particles and extraneous compounds, published research, especially in the field of dewatering of mineral concentrates, is scarce. Whereas the regenerative effect of backwashing and ultrasound are more or less mechanical, regeneration with acids is based on chemistry. The chemistry behind the acid regeneration is, naturally, dissolution. The dissolution of iron oxide particles has been extensively studied over several decades but those studies may not necessarily be directly applicable in the regeneration of the filter medium which has undergone interactions with the slurry components. The aim of this thesis was to investigate if free particle dissolution indeed correlates with the regeneration of the filter medium. For this purpose, both free particle dissolution and dissolution of surface adhered particles were studied. The focus was on acidic dissolution of iron oxide particles and on the study of the ceramic filter medium used in the dewatering of iron ore concentrates. The free particle dissolution experiments show that the solubility of synthetic fine grained iron oxide particles in oxalic acid could be explained through linear models accounting for the effects of temperature and acid concentration, whereas the dissolution of a natural magnetite is not so easily explained by such models. In addition, the kinetic experiments performed both support and contradict the work of previous authors: the suitable kinetic model here supports previous research suggesting solid state reduction to be the reaction mechanism of hematite dissolution but the formation of a stable iron oxalate is not supported by the results of this research. Several other dissolution mechanisms have also been suggested for iron oxide dissolution in oxalic acid, indicating that the details of oxalate promoted reductive dissolution are not yet agreed and, in this respect, this research offers added value to the community. The results of the regeneration experiments with the ceramic filter media show that oxalic acid is highly effective in removing iron oxide particles from the surface of the filter medium. The dissolution of those particles did not, however, exhibit the expected behaviour, i.e. complete dissolution. The results of this thesis show that although the regeneration of the ceramic filter medium with acids incorporates the dissolution of slurry particles from the surface of the filter medium, the regeneration cannot be assessed purely based upon free particle dissolution. A steady state, dependent on temperature and on the acid concentration, was observed in the dissolution of particles from the surface even though the limit of solubility of free iron oxide particles had not been reached. Both the regeneration capacity and efficiency, with regards to the removal of iron oxide particles, was found to be temperature dependent, but was not affected by the acid concentration. This observation further suggests that the removal of the surface adhered particles does not follow the dissolution of free particles, which do exhibit a dependency on the acid concentration. In addition, changes in the permeability and in the pore structure of the filter medium were still observed after the bulk concentration of dissolved iron had reached a steady state. Consequently, the regeneration of the filter medium continued after the dissolution of particles from the surface had ceased. This observation suggests that internal changes take place at the final stages of regeneration. The regeneration process could, in theory, be divided into two, possibly overlapping, stages: (1) dissolution of surface-adhered particles, and (2) dissolution of extraneous compounds from within the pore structure. In addition to the fundamental knowledge generated during this thesis, tools to assess the effects of parameters on the regeneration of the ceramic filter medium are needed. It has become clear that the same tools used to estimate the dissolution of free particles cannot be used to estimate the regeneration of a filter medium unless only a robust characterisation of the order of regeneration efficiency is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 13 x 21 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 13 x 21 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 10 x 14 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 11 x 14 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the results of sacrospinous colpopexy surgery associated with anterior colporrhaphy for the treatment of women with post-hysterectomy vaginal vault prolapse. Methods This prospective study included 20women with vault prolapse, PelvicOrgan Prolapse Quantification System (POP-Q) stage≥2, treated between January 2003 and February 2006, and evaluated in a follow-up review (more than one year later). Genital prolapse was evaluated qualitatively in stages and quantitatively in centimeters. Prolapse stage < 2 was considered to be the cure criterion. Statistical analysis was performed using the Wilcoxon test (paired samples) to compare the points and stages of prolapse before and after surgery. Results Evaluation of the vaginal vault after one year revealed that 95% of subjects were in stage zero and that 5% were in stage 1. For cystocele, 50% were in stage 1, 10% were in stage 0 (cured) and 40% were in stage 2. For rectocele, three women were in stage 1 (15%), one was in stage 2 (5%) and 16 had no further prolapse. The most frequent complication was pain in the right buttock, with remission of symptoms in all three cases three months after surgery. Conclusions In this retrospective study, the surgical correction of vault prolapse using a sacrospinous ligament fixation technique associatedwith anterior colporrhaphy proved effective in resolving genital prolapse. Despite the low complication rates, there was a high rate of cystocele, which may be caused by posterior vaginal shifting due to either the technique or an overvaluation by the POP-Q system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 11 x 14 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 11 x 14 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 11 x 14 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 11 x 14 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työssä selvitettiin uudenaikaisten polymeerikalvojen soveltuvuutta maidon sekä heran mikrosuodatukseen. Kirjallisessa osassa perehdyttiin maidon ja heran koostumuksiin, mikrobikantoihin sekä erilaisiin maidon sekä heran rasvanpoisto- ja puhdistusmenetelmiin. Tämän lisäksi käsiteltiin mikrosuodatusmenetelmiä sekä niiden käyttöä heran ja maidon käsittelyssä meijeriteollisuudessa. Kokeellisessa osassa verrattiin kahdella eri suodatuslaitteistolla keraami- ja polymeerikalvojen suodatusominaisuuksia separoidun raakamaidon sekä heran poikkivirtausmikrosuodatuksessa. Tavoitteena oli erottaa suodatettavista liuoksista mikrobit sekä jäännösrasva ja tuottaa puhdasta, proteiinipitoista maitoa / heraa. Koeajoissa otetuista näytteistä analysoitiin ainesosakoostumus sekä mikrobipitoisuudet. Tuloksista määritettiin retentioarvot ja näiden perusteella vertailtiin polymeeri- ja keraamikalvojen erotustehokkuutta. Lisäksi kalvojen toimivuutta arvioitiin vuoarvojen avulla. Raakamaidon suodatuksissa polymeerikalvot pidättivät täydellisesti tai lähes täydellisesti jäännösrasvan ja mikrobit, mutta myös kaseiiniproteiinin. Tästä syystä yksikään polymeerikalvoista ei sovellu puhtaan maidon suodatukseen. Keraamikalvot soveltuvat tähän selkeästi paremmin ja yksikään toinen testatuista kalvoista ei päässyt samalle tasolle meijeriteollisuudessa jo käytössä olevan Membralox 1,4 μm -keraamikalvon kanssa. Heran suodatuksissa polymeerikalvot pidättivät täydellisesti tai lähes täydellisesti rasvan ja mikrobit, mutta keraamikalvo päästi huomattavasti enemmän haluttuja proteiineja permeaattiin. Membralox 0,8 μm -keraamikalvo pidätti täydellisesti mikrobit, mutta päästi jonkin verran jäännösrasvaa permeaattiin. Näin ollen kalvovalinta on kompromissi permeaatin puhtauden ja proteiinin saannon välillä. Keraamikalvojen vuohäviöt olivat merkittävästi pienemmät kuin polymeerikalvoilla molempien syöttöliuosten kanssa. Lisäksi keraamikalvojen puhdistus oli huomattavasti nopeampaa ja helpompaa. Tästä syystä keraamiset kalvot soveltuvat polymeerisiä paremmin maidon ja heran mikrosuodatukseen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presentation at Open Repositories 2013, DSpace User Group, on 12.7.2013 in Charlottetown, PEI, Canada