999 resultados para 7140-208


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present new Nd isotope records from Walvis Ridge Ocean Drilling Program (ODP) sites 1262-1264 (southeastern Atlantic) spanning the past 24 Ma to investigate the Neogene evolution of Atlantic thermohaline circulation. The new data indicate that deepwater epsilon-Nd(t) values from ODP Site 1262 decrease from -11.0 at 10.6 Ma to -12.5 by 7.3 Ma. This decrease parallels the Nd isotope trends contained in Fe-Mn crust records from the northwestern Atlantic; however, the shift at ODP Site 1262 (4755 m water depth) occurred up to ~6 Ma earlier than the corresponding changes in crust records from the Atlantic and earlier than any Atlantic site shallower than 2700 m paleowater depth. Recent interpretations of the rapid decrease in Fe-Mn crust Nd epsilon-Nd(t)ss values invoke changes in weathering inputs to the Labrador Sea region rather than a fundamental change in deepwater convection in the Labrador Sea. However, the new evidence for significant depth stratification of the Nd isotope signal in the southeastern Atlantic between 10.6 and 7.3 Ma suggests that the onset of deepwater convection in the Labrador Sea may have played a role in the deepwater decrease in Nd isotopic composition. Climatic conditions during the middle to late Miocene likely favored an increase in the importance of glacially induced mechanical weathering, while at the same time promoting deep convection in the Labrador Sea.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the great challenges of the scientific community on theories of genetic information, genetic communication and genetic coding is to determine a mathematical structure related to DNA sequences. In this paper we propose a model of an intra-cellular transmission system of genetic information similar to a model of a power and bandwidth efficient digital communication system in order to identify a mathematical structure in DNA sequences where such sequences are biologically relevant. The model of a transmission system of genetic information is concerned with the identification, reproduction and mathematical classification of the nucleotide sequence of single stranded DNA by the genetic encoder. Hence, a genetic encoder is devised where labelings and cyclic codes are established. The establishment of the algebraic structure of the corresponding codes alphabets, mappings, labelings, primitive polynomials (p(x)) and code generator polynomials (g(x)) are quite important in characterizing error-correcting codes subclasses of G-linear codes. These latter codes are useful for the identification, reproduction and mathematical classification of DNA sequences. The characterization of this model may contribute to the development of a methodology that can be applied in mutational analysis and polymorphisms, production of new drugs and genetic improvement, among other things, resulting in the reduction of time and laboratory costs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Current literature has elucidated a new phenotype, metabolically healthy obese (MHO), with risks of cardiovascular disease similar to that of normal weight individuals. Few studies have examined the MHO phenotype in an aging population, especially in association with subclinical CVD. This cross sectional study population consisted of 208 octogenarians and older. Anthropometrics, biochemical, and radiological parameters were measured to assess obesity, metabolic health (assessed by the National Cholesterol Education Program -Adult Treatment Panel (NCEP-ATP III) criteria), and subclinical measures of CVD. The prevalence of MHO was 13.5% (N = 28). No significant association with MHO was noted for age, coronary artery calcium score, cIMT, or hs-CRP > 3 mg/dl (p = NS). Our results suggest that the MHO phenotype exists in the elderly; however, subclinical CVD measures were not different in sub-group analysis suggesting traditional metabolic risk factor algorithms may not be accurate in the very elderly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although low-density lipoprotein cholesterol (LDL-C) has been consistently demonstrated a predictor of atherosclerotic disease in a large spectrum of clinical settings, among individuals aged of 80 years or older this concept is uncertain. This study was evaluated in a carefully selected population if the association between LDL-C and coronary atherosclerotic burden remains significant in the very elderly. Individuals aged of 80 years or older (n = 208) who spontaneously sought primary prevention care and have never manifested cardiovascular disease, malnutrition, neoplastic or consumptive disease were enrolled for a cross-sectional analysis. Medical evaluation, anthropometric measurements, blood tests and cardiac computed tomography were obtained. In analyses adjusted for age, gender, diabetes, systolic and diastolic blood pressure, smoking and statin therapy, no association was found between coronary calcium score (CCS) and LDL-C [1.79 (0.75-4.29)]. There was no association between triglycerides and CCS. The association between high-density lipoprotein cholesterol (HDL-C) and CCS was significant and robust in unadjusted [0.32 (0.15-0.67)] as well as in the fully adjusted analysis [0.34 (0.15-0.75)]. The present study confirms in a healthy cohort of individuals aged of 80 years or more that while the association between LDL-C and coronary atherosclerosis weakens with aging, the opposite occurs with the levels of HDL-C.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrochemical properties of methylene blue immobilized on cellulose/TiO2 and mixed oxide SiO2/TiO2 matrices were investigated by means of cyclic voltammetry. The electron mediator property of the methylene blue was optimized using a factorial design, consisting of four factors in two levels. The experimental observations and data analyses on the system indicate that the lowest peak separation occurs for Sil/TiOAM, 1.0 mol L-1 KCl solution and 20 mV s-1 scan rate, while values of current ratio closest to unity were found for Cel/TiOAM independent of electrolyte concentration, 0.2 or 1.0 mol L-1, and scan rate, 20 mV s-1 or 60 mV s-1.