950 resultados para vortex loop


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To compare the effectiveness between the see-and-treat (S&T) approach and the conventional one (with prior biopsy) for squamous intraepithelial lesions of uterine cervix. METHODS: A cross-sectional study was conducted with 900 nonpregnant women with cytology suggestive of high grade squamous intraepithelial lesions in the city of Rio de Janeiro, Southeastern Brazil, between 1998 and 2004. The S&T approach consists of a large loop excision of the transformation zone procedure and is recommended when cytology is suggestive of high grade squamous intraepithelial lesion, satisfactory colposcopy with abnormalities compatible with the suspected cytological results, and the lesion is limited to the ectocervix or extends up to one centimeter of the endocervical canal. A subgroup of 336 patients whose colposcopy was considered satisfactory was analyzed, and they were divided into two groups for comparison: patients treated without prior biopsy (n = 288) and patients treated after a biopsy showing high grade squamous intraepithelial lesions (n = 48). Patients who were not treated or only treated more than a year later after recruitment at the colposcopy unit were considered dropouts. RESULTS: Of patients recruited during the study period, 71 were not treated or were only treated for at least a year. The overall dropout rate was 7.9% (95% CI: 6.1;9.7). Mean time elapsed between patient recruitment and treatment was 17.5 days in the S&T group and 102.5 days in the prior biopsy group. Dropout rates were 1.4% (95% CI: 0.04;2.7) and 5.% (95% CI: 0;12.3), respectively (p=0.07). The proportion of overtreated cases (negative histology) in the S&T group was 2.0% (95% CI: 0.4;3.6). CONCLUSIONS: The difference in the mean time elapsed between patient recruitment and treatment indicates that S&T is a time-saving approach The proportion of negative cases from using the S&T approach can be regarded as low.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The most general Two Higgs Doublet Model potential without explicit CP violation depends on 10 real independent parameters. Excluding spontaneous CP violation results in two 7 parameter models. Although both models give rise to 5 scalar particles and 2 mixing angles, the resulting phenomenology of the scalar sectors is different. If flavour changing neutral currents at tree level are to be avoided, one has, in both cases, four alternative ways of introducing the fermion couplings. In one of these models the mixing angle of the CP even sector can be chosen in such a way that the fermion couplings to the lightest scalar Higgs boson vanishes. At the same time it is possible to suppress the fermion couplings to the charged and pseudo-scalar Higgs bosons by appropriately choosing the mixing angle of the CP odd sector. We investigate the phenomenology of both models in the fermiophobic limit and present the different branching ratios for the decays of the scalar particles. We use the present experimental results from the LEP collider to constrain the models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho de pesquisa e desenvolvimento tem como fundamento principal o Conceito de Controlo por Lógica Difusa. Utilizando as ferramentas do software Matlab, foi possível desenvolver um controlador com base na inferência difusa que permitisse controlar qualquer tipo de sistema físico real, independentemente das suas características. O Controlo Lógico Difuso, do inglês “Fuzzy Control”, é um tipo de controlo muito particular, pois permite o uso simultâneo de dados numéricos com variáveis linguísticas que tem por base o conhecimento heurístico dos sistemas a controlar. Desta forma, consegue-se quantificar, por exemplo, se um copo está “meio cheio” ou “meio vazio”, se uma pessoa é “alta” ou “baixa”, se está “frio” ou “muito frio”. O controlo PID é, sem dúvida alguma, o controlador mais amplamente utilizado no controlo de sistemas. Devido à sua simplicidade de construção, aos reduzidos custos de aplicação e manutenção e aos resultados que se obtêm, este controlador torna-se a primeira opção quando se pretende implementar uma malha de controlo num determinado sistema. Caracterizado por três parâmetros de ajuste, a saber componente proporcional, integral e derivativa, as três em conjunto permitem uma sintonia eficaz de qualquer tipo de sistema. De forma a automatizar o processo de sintonia de controladores e, aproveitando o que melhor oferece o Controlo Difuso e o Controlo PID, agrupou-se os dois controladores, onde em conjunto, como poderemos constatar mais adiante, foram obtidos resultados que vão de encontro com os objectivos traçados. Com o auxílio do simulink do Matlab, foi desenvolvido o diagrama de blocos do sistema de controlo, onde o controlador difuso tem a tarefa de supervisionar a resposta do controlador PID, corrigindo-a ao longo do tempo de simulação. O controlador desenvolvido é denominado por Controlador FuzzyPID. Durante o desenvolvimento prático do trabalho, foi simulada a resposta de diversos sistemas à entrada em degrau unitário. Os sistemas estudados são na sua maioria sistemas físicos reais, que representam sistemas mecânicos, térmicos, pneumáticos, eléctricos, etc., e que podem ser facilmente descritos por funções de transferência de primeira, segunda e de ordem superior, com e sem atraso.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

QuEChERS method was evaluated for extraction of 16 PAHs from fish samples. For a selective measurement of the compounds, extracts were analysed by LC with fluorescence detection. The overall analytical procedure was validated by systematic recovery experiments at three levels and by using the standard reference material SRM 2977 (mussel tissue). The targeted contaminants, except naphthalene and acenaphthene, were successfully extracted from SRM 2977 with recoveries ranging from 63.5–110.0% with variation coefficients not exceeding 8%. The optimum QuEChERS conditions were the following: 5 g of homogenised fish sample, 10 mL of ACN, agitation performed by vortex during 3 min. Quantification limits ranging from 0.12– 1.90 ng/g wet weight (0.30–4.70 µg/L) were obtained. The optimized methodology was applied to assess the safety concerning PAHs contents of horse mackerel (Trachurus trachurus), chub mackerel (Scomber japonicus), sardine (Sardina pilchardus) and farmed seabass (Dicentrarchus labrax). Although benzo(a)pyrene, the marker used for evaluating the carcinogenic risk of PAHs in food, was not detected in the analysed samples (89 individuals corresponding to 27 homogenized samples), the overall mean concentration ranged from 2.52 l 1.20 ng/g in horse mackerel to 14.6 ± 2.8 ng/ g in farmed seabass. Significant differences were found between the mean PAHs concentrations of the four groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre Em Engenharia Química e Biológica Ramo de processos Químicos

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports on the analysis of tidal breathing patterns measured during noninvasive forced oscillation lung function tests in six individual groups. The three adult groups were healthy, with prediagnosed chronic obstructive pulmonary disease, and with prediagnosed kyphoscoliosis, respectively. The three children groups were healthy, with prediagnosed asthma, and with prediagnosed cystic fibrosis, respectively. The analysis is applied to the pressure–volume curves and the pseudophaseplane loop by means of the box-counting method, which gives a measure of the area within each loop. The objective was to verify if there exists a link between the area of the loops, power-law patterns, and alterations in the respiratory structure with disease. We obtained statistically significant variations between the data sets corresponding to the six groups of patients, showing also the existence of power-law patterns. Our findings support the idea that the respiratory system changes with disease in terms of airway geometry and tissue parameters, leading, in turn, to variations in the fractal dimension of the respiratory tree and its dynamics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper investigates the use of multidimensional scaling in the evaluation of fractional system. Several algorithms are analysed based on the time response of the closed loop system under the action of a reference step input signal. Two alternative performance indices, based on the time and frequency domains, are tested. The numerical experiments demonstrate the feasibility of the proposed visualization method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Kinematic redundancy occurs when a manipulator possesses more degrees of freedom than those required to execute a given task. Several kinematic techniques for redundant manipulators control the gripper through the pseudo-inverse of the Jacobian, but lead to a kind of chaotic inner motion with unpredictable arm configurations. Such algorithms are not easy to adapt to optimization schemes and, moreover, often there are multiple optimization objectives that can conflict between them. Unlike single optimization, where one attempts to find the best solution, in multi-objective optimization there is no single solution that is optimum with respect to all indices. Therefore, trajectory planning of redundant robots remains an important area of research and more efficient optimization algorithms are needed. This paper presents a new technique to solve the inverse kinematics of redundant manipulators, using a multi-objective genetic algorithm. This scheme combines the closed-loop pseudo-inverse method with a multi-objective genetic algorithm to control the joint positions. Simulations for manipulators with three or four rotational joints, considering the optimization of two objectives in a workspace without and with obstacles are developed. The results reveal that it is possible to choose several solutions from the Pareto optimal front according to the importance of each individual objective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Journal of Biological Chemistry Vol. 278, No. 19, Issue of May 9, pp. 17455–17465, 2003

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The availability of small inexpensive sensor elements enables the employment of large wired or wireless sensor networks for feeding control systems. Unfortunately, the need to transmit a large number of sensor measurements over a network negatively affects the timing parameters of the control loop. This paper presents a solution to this problem by representing sensor measurements with an approximate representation-an interpolation of sensor measurements as a function of space coordinates. A priority-based medium access control (MAC) protocol is used to select the sensor messages with high information content. Thus, the information from a large number of sensor measurements is conveyed within a few messages. This approach greatly reduces the time for obtaining a snapshot of the environment state and therefore supports the real-time requirements of feedback control loops.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper addresses the use of multidimensional scaling in the evaluation of controller performance. Several nonlinear systems are analyzed based on the closed loop time response under the action of a reference step input signal. Three alternative performance indices, based on the time response, Fourier analysis, and mutual information, are tested. The numerical experiments demonstrate the feasibility of the proposed methodology and motivate its extension for other performance measures and new classes of nonlinearities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A noncoherent vector delay/frequency-locked loop (VDFLL) architecture for GNSS receivers is proposed. A bank of code and frequency discriminators feeds a central extended Kalman filter that estimates the receiver's position and velocity, besides the clock error. The VDFLL architecture performance is compared with the one of the classic scalar receiver, both for scintillation and multipath scenarios, in terms of position errors. We show that the proposed solution is superior to the conventional scalar receivers, which tend to lose lock rapidly, due to the sudden drops of the received signal power.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We analyze the advantages and drawbacks of a vector delay/frequency-locked loop (VDFLL) architecture regarding the conventional scalar and the vector delay-locked loop (VDLL) architectures for GNSS receivers in harsh scenarios that include ionospheric scintillation, multipath, and high dynamics motion. The VDFLL is constituted by a bank of code and frequency discriminators feeding a central extended Kaiman filter (EKF) that estimates the receiver's position, velocity, and clock bias. Both code and frequency loops are closed vectorially through the EKF. The VDLL closes the code loop vectorially and the phase loops through individual PLLs while the scalar receiver closes both loops by means of individual independent PLLs and DLLs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The advantageous use of fractional calculus (FC) in the modeling and control of many dynamical systems has been recognized. In this paper, we study the control of a heat diffusion system based on the application of the FC concepts. Several algorithms are investigated and compared, when integrated within a Smith predictor control structure. Simulations are presented assessing the performance of the proposed fractional algorithms.