839 resultados para titanium derivative


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A proper cast is essential for a successful rehabilitation with implant prostheses, in order to produce better structures and induce less strain on the implants. The aim of this study was to evaluate the precision of four different mold filling techniques and verify an accurate methodology to evaluate these techniques. A total of 40 casts were obtained from a metallic matrix simulating three unit implant-retained prostheses. The molds were filled using four different techniques in four groups (n = 10): Group 1 - Single-portion filling technique; Group 2 - Two-step filling technique; Group 3 - Latex cylinder technique; Group 4 - Joining the implant analogs previously to the mold filling. A titanium framework was obtained and used as a reference to evaluate the marginal misfit and tension forces in each cast. Vertical misfit was measured with an optical microscope with an increase of 120 times following the single-screw test protocol. Strain was quantified using strain gauges. Data were analyzed using one-way ANOVA (Tukey's test) (α =0.05). The correlation between strain and vertical misfit was evaluated by Pearson test. The misfit values did not present statistical difference (P = 0.979), while the strain results showed statistical difference between Groups 3 and 4 (P = 0.027). The splinting technique was considered to be as efficient as the conventional technique. The strain gauge methodology was accurate for strain measurements and cast distortion evaluation. There was no correlation between strain and marginal misfit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Friction coefficient (FC) was quantified between titanium-titanium (Ti-Ti) and titanium-zirconia (Ti-Zr), materials commonly used as abutment and implants, in the presence of a multispecies biofilm (Bf) or salivary pellicle (Pel). Furthermore, FC was used as a parameter to evaluate the biomechanical behavior of a single implant-supported restoration. Interface between Ti-Ti and Ti-Zr without Pel or Bf was used as control (Ctrl). FC was recorded using tribometer and analyzed by two-way Anova and Tukey test (p<0.05). Data were transposed to a finite element model of a dental implant-supported restoration. Models were obtained varying abutment material (Ti and Zr) and FCs recorded (Bf, Pel, and Ctrl). Maximum and shear stress were calculated for bone and equivalent von Misses for prosthetic components. Data were analyzed using two-way ANOVA (p<0.05) and percentage of contribution for each condition (material and FC) was calculated. FC significant differences were observed between Ti-Ti and Ti-Zr for Ctrl and Bf groups, with lower values for Ti-Zr (p<0.05). Within each material group, Ti-Ti differed between all treatments (p<0.05) and for Ti-Zr, only Pel showed higher values compared with Ctrl and Bf (p<0.05). FC contributed to 89.83% (p<0.05) of the stress in the screw, decreasing the stress when the FC was lower. FC resulted in an increase of 59.78% of maximum stress in cortical bone (p=0.05). It can be concluded that the shift of the FC due to the presence of Pel or Bf is able to jeopardize the biomechanical behavior of a single implant-supported restoration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The establishment of the most stable structures of eight membered rings is a challenging task to the field of conformational analysis. In this work, a series of 2-halocyclooctanones were synthesized (including fluorine, chlorine, bromine and iodine derivatives) and submitted to conformational studies using a combination of theoretical calculation and infrared spectroscopy. For each compound, four conformations were identified as the most important ones. These conformations are derived from the chair-boat conformation of cyclooctanone. The pseudo-equatorial (with respect to the halogen) conformer is preferred in vacuum and in low polarity solvents for chlorine, bromine and iodine derivatives. For 2-fluorocyclooctanone, the preferred conformation in vacuum is pseudo-axial. In acetonitrile, the pseudo-axial conformer becomes the most stable for the chlorine derivative. According to NBO calculations, the conformational preference is not dictated by electron delocalization, but by classical electrostatic repulsions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There has been a considerable interest in coordination complexes of molecular nitrogen (N2), partly due to a possible relationship between such complexes and the nitrogen activation process in nature. The present paper describes the synthesis and infrared spectroscopic characterization of an iron-nitrogen derivative with ethylenediamine-N,N,N',N'-tetraacetate (edta) as an experiment for an undergraduate course. The topics covered here include synthesis, reactivity and spectroscopy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The copolymer poly (L-co-D,L lactic acid), PLDLA, has gained prominence in the field of temporary prostheses due to the fact that their time of degradation is quite compatible with the requirement in the case of osseous fracture. In this work the in vivo degradation of devices from copolymer, as a system of plates and screws, used in fixation of the tibia of rabbits was studied. The devices were implanted in 15 adult rabbits, albinos, New Zealand race, and they were used as control devices of alloys of titanium (Ti-6Al-4V/ V grade). The use of copolymers, synthesized in the laboratory, was tested in the repair of fracture in rabbits'tibias, being assessed in the following times: 2 weeks, 2 months and 3 months. Morphological analysis of tissue surrounding the plate and screw system, for 2 weeks of implantation, showed the presence of osteoblasts, indicating a pre bone formation. After 2 months there was new bone formation in the region in contact with the polymer. This bone growth occurred simultaneously with the process of PLDLA degradation, invading the region where there was polymer and after 3 months there was an intense degradation of the copolymer and hence greater tissue invasion compared to 2 months which characterized bone formation in a region where the polymer degraded. The in vivo degradation study of the devices for PLDLA by means of histological evaluations during the period of consolidation of the fracture showed the efficiency of plate and screw system, and it was possible to check formation of bone tissue at the implantation site, without the presence of inflammatory reaction

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure titanium. The misfit was analyzed with a comparator microscope after 20 Ncm torque. The highest value of misfit observed per abutment was used. The torque required to loose the screw was evaluated using a digital torque meter. The torque loss values, measured by the torque meter, were assumed as percentage of initial torque (100%) given to abutment screws. Pearson's correlation (α=0.05) between the misfit values (29.08 ± 8.78 µm) and the percentage of detorque (50.71 ± 11.37%) showed no statistically significant correlation (p=0.295). Within the limitations of this study, it may be concluded that great vertical misfits dot not necessarily implies in higher detorque values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cleaning capacity of Hero 642 nickel-titanium files, complemented by the Hero Apical instruments in flattened roots, was determined by histological analysis, considering the area of action of the instruments on the coronal walls and the presence of remaining debris. Twenty-four single-canal, human mandibular incisors were divided into three groups and prepared as follows: GI, instrumented with Hero 642 NiTi files 30/.06, 25/.06, 20/.06, 25/.06, and 30/.06; GII, instrumented as GI followed by Hero Apical size 30/.06; GIII, instrumented as GI followed by Hero Apical sizes 30/.06 and 30/.08, then returning to 30/.06 with pendulum movements. The apical thirds were prepared for histological processing, analyzed at 40× magnification and the images were examined morphometrically. Statistical analysis showed that GIII presented the best results for removing debris (5.22% ± 4.13), with more contact between the instruments and the root canal walls (19.31% ± 0.15). This differed statistically from GI (14.04% ± 4.96 debris removal, with 42.96% ± 7.11 instrument contact) and GII (12.62% ± 5.76 debris removal, with 35.01% ± 0.15 instrument contact). Root canal preparation with Hero 642, complemented by Hero Apical instruments (30/.06 and 30/.08, then re-instrumented with Hero Apical 30/.06 using pendulum movements), was more efficient for debris removal and allowed more contact of the instruments with the root canal walls. GII presented the worst results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to verify whether screw abutment lubrication can generate higher preload values compared to non-lubricated screws, a titanium abutment was screwed onto an implant analog and scanned with the Procera System to generate 20 zirconia abutments. MKIII Brånemark implants were clamped to a precision torque device, and the abutments were distributed in dry and wet groups with 10 specimens each. In the wet groups, the inner threads of the implants were filled with artificial saliva. All abutments were fastened with a Torqtite screw under 32 Ncm. Ten detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean detorque values were calculated and compared by a Student's t test (?=0.05). The wet condition presented significantly higher mean detorque than the dry condition (31.5 ± 1.2 versus 27.5 ± 1.5 Ncm, respectively; p=0.0000024). In conclusion, there was always a loss in the initial torque values when the removal torque was measured under both conditions. The wet condition presented higher mean torque than the dry condition. Better preload values were established in the wet group, suggesting that the abutment screw must be lubricated in saliva to avoid further loosening.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

FUNDAMENTO: A ressuscitação de parada cardíaca pode apresentar disfunção miocárdica determinada pelo tempo da isquemia, e a inibição da enzima conversora de angiotensina (ECA) pode reduzir a disfunção cardíaca durante a reperfusão. OBJETIVO: Investigar os efeitos da angiotensina-I e diferentes períodos de isquemia na recuperação funcional em corações de ratos isolados. MÉTODOS: Os corações isolados de ratos Wistar (n = 45; 250-300 g) foram submetidos a diferentes períodos de isquemia global (20, 25 ou 30 min) e reperfundidos (30 min) com o tampão Krebs-Henseleit, ou com a adição de 400 nmol/L de angiotensina-I, ou com 400 nmol/L de angiotensina-I + 100 µmol/L de captopril durante o período de reperfusão. RESULTADOS: A derivada positiva máxima de pressão (+dP/dt max) e o produto frequência-pressão foram reduzidos nos corações expostos à isquemia de 25 min (~ 73%) e à isquemia de 30 min (~ 80%) vs. isquemia de 20 min. A pressão diastólica final do ventrículo esquerdo (PDFVE) e a pressão de perfusão (PP) foram aumentadas nos corações expostos à isquemia de 25 min (5,5 e 1,08 vezes, respectivamente) e à isquemia de 30 min (6 e 1,10 vezes, respectivamente) vs. isquemia de 20 min. A angiotensina-I ocasionou uma diminuição no +dP/dt max e no produto frequência-pressão (~ 85-94%) em todos os períodos de isquemia e um aumento na PDFVE e na PP (6,9 e 1,25 vezes, respectivamente) apenas na isquemia de 20 min. O captopril foi capaz de reverter parcial ou completamente os efeitos da angiotensina-I na recuperação funcional nas isquemias de 20 e 25 min CONCLUSÃO: Os dados sugerem que a angiotensina-II participa direta ou indiretamente no dano pós-isquêmico e que a capacidade de um inibidor da ECA atenuar esse dano depende do tempo de isquemia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the in vitro susceptibility of C. albicans, C. dubliniensis, C. tropicalis and C. krusei to photodynamic therapy (PDT) induced by Photogem® and light emitting diode (LED). Suspensions of each Candida strain were treated with three photosensitizer (PS) concentrations (10, 25 and 50 mg/L) and exposed to 18.0, 25.5 and 37.5 J/cm² LED light fluences (λ ~ 455 nm). Control suspensions were treated only with PS concentrations, only exposed to the LED light fluences or not exposed to LED light or PS. Sixteen experimental conditions were obtained and each condition was repeated three times. From each sample, serial dilutions were obtained and aliquots were plated on Sabouraud Dextrose Agar. After incubation of plates (37 ºC for 48 hours), colonies were counted (cfu/mL) and the data were statistically analyzed by ANOVA and the Tukey test (α=0.05). Complete killing of C. albicans was observed after 18.0 J/cm² in association with 50 mg/L of PS. C. dubliniensis were inactivated after 18.0 J/cm² using 25 mg/L of PS. The inactivation of C. tropicalis was observed after photosensitization with 25 mg/L and subsequent illumination at 25.5 J/cm². For C. krusei, none of the associations between PS and light resulted in complete killing of this species. PDT proved to be effective for the inactivation of C. albicans, C. dubliniensis and C. tropicalis. In addition, reduction in the viability of C. krusei was achieved with some of the PS and light associations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The heterometal alkoxide [FeCl{Ti2(OPr i)9}] (1) was employed as a single source precursor for the preparation of Fe/Ti oxides under inert atmosphere. Three different synthetic procedures were adopted in the processing of 1, either employing aqueous HNO3 or HCl solutions, or in the absence of mineral acids. Products were characterised by powder X-ray diffractometry, scanning electron microscopy combined with energy dispersive X-ray spectroscopy (SEM/EDS) and Raman, electron paramagnetic resonance (EPR) and Mössbauer spectroscopies. Oxide products contained titanium(IV) and either iron(III) or iron(II), depending on reaction conditions and thermal treatment temperatures. An interesting iron(III)→iron(II) reduction was observed at 1000 ºC in the HNO3-containing system, leading to the detection of ilmenite (FeTiO3). SEM/EDS studies revealed a highly heterogeneous metal distribution in all products, possibly related to the presence of a significant content of carbon and of structural defects (oxygen vacancies) in the solids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The determination of acetic acid in vinegar adulterated sample using simultaneous potentiometric and condutometric titrations was used as an example of integrated experiment in instrumental analysis. An Excel® spreadsheet, which allows the entry of simultaneous data and the construction of the superimposed experimental curves (condutometric, potentiometric, first and second derivative potentiometric curve and, distribution diagrama of the acetic species as function of pH), was used as powerful tool to discuss the fundamental concepts involved in each technique and choose the best of them to quantify, without mutual interference, H3CCOOH and HCl in vinegar adulterated sample.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work revisits the fruits of Iryanthera juruensis and Virola pavonis and the leaves from V. michelii, as well as describing a study of the fruits of V. mollissima. In I. juruensis aryltetraline neolignan (1) and tetrahydrofuran neolignan (2), were found while from V. pavonis neolignans of benzofuran type (6-9), the tetrahydrofuran type (2, 11-13, 17) and the biphenyl type (10), in addition to diastereoisomers of the 8.O.4'-oxyneolignan type (14 and 15) and others were isolated. The V. mollissima accumulates the aryltetralone neolignan 4 and its seco derivative (5). The lignoids 1 and 2 obtained from I. juruensis arils possess antileishmanial activity against the promastigote form of Leishmania amazonensis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dez amostras de cálculos renais foram estudadas por Análise Elementar de CHN (EA), Espectroscopia de Absorção no Infravermelho (IV) e Difração de raios X pelo método de Pó (XRD). O comportamento térmico das amostras foi estudado por Termogravimetria/Termogravimetria Derivada (TG/DTG) e por Calorimetria Exploratória Diferencial (DSC). Os resultados de EA, Espectroscopia de Absorção IV e XRD mostraram a presença de estruvita [NH4Mg(PO4).6H2O], apatita, oxalato de cálcio monohidratado e oxalato de cálcio dihidratado. As curvas TG e DSC permitiram classificar as amostras em dois grupos diferentes: Grupo I mostrando comportamento térmico típico de estruvita e Grupo II apresentando um perfil termoanalítico característico de mistura de oxalatos.