889 resultados para spiral computer assisted tomography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FMVZ

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Aquicultura - FCAV

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper considers a study of the anatomical features of the cardiac system and a three-dimensional model of the different tunics that comprise the heart wall, for processing and quality control of radiological images. The structures are built by the layer overlapping method, where a layer can be understood as a slice of the three-dimensional object. The pericardium, myocardium and endocardium were represented with three-dimensional cylinders and hexagons. The spatial arrangement of the cardiac system is determined by an background image of a real model, which values are defined according to the shape of the region and on the anatomical patients characteristics. The results are significant, considering the anatomical structures details, as well as the representation of the thicknesses of the regions of the heart wall. The validation of the anatomical model was accomplished through comparisons with dimensions obtained from a real model and allows verifying that the model is appropriate. The degree of representation will allow the verification of the influence of radiological parameters, morphometric peculiarities and stage of the diseases on the quality of the images, as well as on the performance of the Computer-Aided Diagnosis (CAD).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over the last years, the new technologies have changed the way we relate to information and communicate with other people, which has brought on impact to foreign language teaching and learning, and, consequently, to the area of foreign language teacher education. The abbreviation CALL (Computer Assisted Language Learning) has been used to designate the processes of language teaching and learning with the use of computers, and language teacher education in CALL to name teacher education for and with the use of new technologies, since a number of authors point to the interdependence of both processes. We intend in this article to present an overview of the literature of the area of language teacher education in CALL nowadays and discuss issues related to the use of new technologies concerning its integration to teacher education and the functional and institutional roles to be taken. We also present two proposals of teacher education with the use of new technologies which are being implemented and at the same time studied in Brazil, which we believe have essential elements for the development of language teachers for and with the use of new technologies currently.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of digitization parameters on periapical radiographic image quality, with regard to anatomic landmarks. Digitized images (n = 160) were obtained using a flatbed scanner with resolutions of 300, 600 and 2400 dpi. The radiographs of 2400 dpi were decreased to 300 and 600 dpi before storage. Digitizations were performed with and without black masking using 8-bit and 16-bit grayscale and saved in TIFF format. Four anatomic landmarks were classified by two observers (very good, good, moderate, regular, poor), in two random sessions. Intraobserver and interobserver agreements were evaluated by Kappa statistics. Inter and intraobserver agreements ranged according to the anatomic landmarks and resolution used. The results obtained demonstrated that the cement enamel junction was the anatomic landmark that presented the poorest concordance. The use of black masking provided better results in the digitized image. The use of a mask to cover radiographs during digitization is necessary. Therefore, the concordance ranged from regular to moderate for the intraobserver evaluation and concordance ranged from regular to poor for interobserver evaluation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Considering that downregulation of HLA expression could represent a potential mechanism for breast carcinogenesis and metastasis, the aim of the present study was to use immunohistochemical methods to analyze the expression of HLA-Ia, HLA-DR, HLA-DQ, HLA-E, and HLA-G in invasive ductal carcinoma (IDC) of the breast and to relate this HLA profile to anatomopathological parameters. Fifty-two IDC from breast biopsies were stratified according to histological differentiation (well, moderately, and poorly differentiated) and to the presence of metastases in axillary lymph nodes. The expression of HLA molecules was assessed by immunohistochemistry, using a computer-assisted system. Overall, 31 (59.6%) out of the 52 IDC breast biopsies exhibited high expression of HLA-G, but only 14 (26.9%) showed high expression of HLA-E. A large number (41, 78.8%) of the biopsies showed low expression of HLA-Ia, while 45 (86.5%) showed high expression of HLA-DQ and 36 (69.2%) underexpressed HLA-DR. Moreover, 24 (41.2%) of 52 biopsies had both low HLA-Ia expression and high HLA-G expression, while 11 (21.2%) had low HLA-Ia expression and high HLA-E expression. These results suggest that, by different mechanisms, the downregulation of HLA-Ia, HLA-E, and HLA-DR and the upregulation of HLA-G and HLA-DQ are associated with immune response evasion and breast cancer aggressiveness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of technologies called computedassisted, such as CAD - (Computed Aided Design), CAM - (Computed Aided Manufacturing) and CNC - (Computed Numerical Control), increasingly demanded by the market, are needed in the teaching of subjects technical drawing and design courses for engineering and design. However its use findl barriers in the more conservative wing of the academy, who advocate the use of traditional drawing, for the settling of the concepts and the development of spatial reasoning. This study aimed to show the results obtained with the design and production of an apparatus for measuring a three-dimensional computer-aided milling machine, interaction, integration and consolidation of concepts, fully demonstrating that the learning of computer-assisted technology is possible, and its use is most appropriate, meaningful and productive, than the use of instruments in the classic design.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of computer-assisted technologies such as CAD - Computed Aided Design, CAM - Computed Aided Manufacturing, CAE - Computed Aided Engineering and CNC - Computed Numerical Control, are priorities in engineering and product designers. However, the dimensional measurement between the virtual and the real product design requires research, and dissemination procedures among its users. This work aims to use these technologies, through analysis and measurement of a CNC milling machine, designed and assembled in the university. Through the use of 3D scanning, and analyzing images of the machined samples, and its original virtual files, it was possible to compare the sizes of these samples in counterposition to the original virtual dimensions, we can state that the distortions between the real and virtual, are within acceptable limits for this type of equipment. As a secondary objective, this work seeks to disseminate and make more accessible the use of these technologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Centrifugal countercurrent distribution (CCCD) in an aqueous two-phase system (TPS) is a resolute technique revealing sperm heterogeneity and for the estimation of the fertilizing potential of a given semen sample. However, separated sperm subpopulations have never been tested for their fertilizing ability yet. Here, we have compared sperm quality parameters and the fertilizing ability of sperm subpopulations separated by the CCCD process from ram semen samples maintained at 20 degrees C or cooled down to 5 degrees C. Total and progressive sperm motility was evaluated by computer-assisted analysis using a CASA system and membrane integrity was evaluated by flow cytometry by staining with CFDA/Pl. The capacitation state, staining with chlortetracycline, and apoptosis-related markers, such as phosphatidylserine (PS) translocation detected with Annexin V. and DNA damage detected by the TUNEL assay, were determined by fluorescence microscopy. Additionally, the fertilizing ability of the fractionated subpopulations was comparative assessed by zona binding assay (ZBA). CCCD analysis revealed that the number of spermatozoa displaying membrane and DNA alterations was higher in samples chilled at 5 degrees C than at 20 degrees C. which can be reflected in the displacement to the left of the CCCD profiles. The spermatozoa located in the central and right chambers (more hydrophobic) presented higher values (P<0.01) of membrane integrity, lower PS translocation (P<0.05) and DNA damage (P<0.001) than those in the left part of the profile, where apoptotic markers were significantly increased and the proportion of viable non-capacitated sperm was reduced. We have developed a new protocol to recover spermatozoa from the CCCD fractions and we proved that these differences were related with the fertilizing ability determined by ZBA, because we found that the number of spermatozoa attached per oocyte was significantly higher for spermatozoa recovered from the central and right chambers, in both types of samples. This is the first time, to our knowledge that sperm recovered from a two-phase partition procedure are used for fertilization assays. These results open up new possibilities for using specific subpopulations of sperm for artificial insemination or in vitro fertilization, not only regarding better sperm quality but also certain characteristics such as subpopulations enriched in spermatozoa bearing X or Y chromosome that we have already isolated or any other feature. (C) 2011 Elsevier B.V. All rights reserved.