994 resultados para soft-commutation technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reduction of radar cross -section of dihedral corner reflectors using simulated corrugated surface (.SCS) is reported. This technique is found lo be more effective in the reduction of RCS or corner reflectors for normal incidence . A typical reduction of 40-50 dB is achieved using this method

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mathematical formulation of empirically developed formulas Jirr the calculation of the resonant frequency of a thick-substrate (h s 0.08151 A,,) microstrip antenna has been analyzed. With the use qt' tunnel-based artificial neural networks (ANNs), the resonant frequency of antennas with h satisfying the thick-substrate condition are calculated and compared with the existing experimental results and also with the simulation results obtained with the use of an IE3D software package. The artificial neural network results are in very good agreement with the experimental results

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reduction of radar cross -section of dihedral corner reflectors using simulated corrugated surface (SCS) is reported. The technique is found to be more effective in the reduction of RCS or corner reflectors for normal incidence . A typical reduction of 40-50 dB is achieved using this method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dual beam mode-matched thermal lens method has been employed to measure the heat diffusion in nanofluid of silver with various volumes of rhodamine 6G, both dispersed in water. The important observation is an indication of temperature dependent diffusivity and that the overall heat diffusion is slower in the chemically prepared Ag sol compared to that of water. The experimental results can be explained assuming that Brownian motion is the main mechanism of heat transfer under the present experimental conditions. Light induced aggregation of the nanoparticles can also result in an anomalous diffusion behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal diffusivity (TD) measurement on commercial K-10 and KSF montmorillonites was carried out by photoacoustic technique. The TD of the montmorillonites after methylene blue adsorption changed with the dye concentration. The repeatedly adsorbed samples showed a lesser TD than the single adsorbed samples. After methylene blue adsorption the acid leached K-10 samples showed well defined changes in TD when compared to the ordered KSF samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An open photoacoustic cell operating in the low range of chopping frequency has been employed to evaluate the thermal diffusivity values of intrinsic InP and InP doped with S, Sn and Fe. The experimental set-up is calibrated by the evaluation of thermal diffusivity value of pure Si and GaAs. The present investigation shows that doped samples show a reduced value for thermal diffusivity compared to intrinsic sample. From the analysis of data it is also seen that nature of dopant clearly influences the thermal diffusivity value of semiconductors. The results are explained in terms of phonon assisted heat transfer mechanism in semiconductors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An open photoacoustic cell operating in the low range of chopping frequency has been employed to evaluate the thermal diffusivity values of intrinsic InP and InP doped with S, Sn and Fe. The experimental set-up is calibrated by the evaluation of thermal diffusivity value of pure Si and GaAs. The present investigation shows that doped samples show a reduced value for thermal diffusivity compared to intrinsic sample. From the analysis of data it is also seen that nature of dopant clearly influences the thermal diffusivity value of semiconductors. The results are explained in terms of phonon assisted heat transfer mechanism in semiconductors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An open photoacoustic cell operating in the low range of chopping frequency has been employed to evaluate the thermal diffusivity values of intrinsic InP and InP doped with S, Sn and Fe. The experimental set-up is calibrated by the evaluation of thermal diffusivity value of pure Si and GaAs. The present investigation shows that doped samples show a reduced value for thermal diffusivity compared to intrinsic sample. From the analysis of data it is also seen that nature of dopant clearly influences the thermal diffusivity value of semiconductors. The results are explained in terms of phonon assisted heat transfer mechanism in semiconductors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trawling, though an efficient method of fishing, is known to be one of the most non-selective methods of fish capture. The bulk of the wild caught penaeid shrimps landed in India are caught by trawling.In addition to shrimps, the trawler fleet also catches considerable amount of non-shrimp resources. The term bycatch means that portion of the catch other than target species caught while fishing, which are either retained or discarded. Bycatch discards is a serious problem leading to the depletion of the resources and negative impacts on biodiversity. In order to minimize this problem, trawling has to be made more selective by incorporating Bycatch Reduction Devices (BRDs). There are several advantages in using BRDs in shrimp trawling. BRDs reduce the negative impacts of shrimp trawling on marine community. Fishers could benefit economically from higher catch value due to improved catch quality, shorter sorting time, lower fuel costs, and longer tow duration. Adoption of BRDs by fishers would forestall criticism by conservation groups against trawling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photoplethysmography (PPG) is a simple and inexpensive optical technique that can be used to detect blood volume changes in the microvascular bed of tissues. There has been a resurgence of interest in the technique in recent years, driven by the demand for low cost, simple and portable technology for the primary care and community based clinical settings and the wide availability of low cost and small semiconductor components, and the advancement of computer-based pulse wave analysis techniques. The present research work deals with the design of a PPG sensor for recording the blood volume pulse signals and carry out selected cardiovascular studies based on these signals. The interaction of light with tissue, early and recent history of PPG, instrumentation, measurement protocol and pulse wave analysis are also discussed in this study. The effect of aging, mild cold exposure, and variation in the body posture on the PPG signal have been experimentally studied.