997 resultados para pressure equipment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the clinical outcome of patients who received a Baerveldt implant for refractory glaucoma and to identify factors which may influence the outcome. METHODS: Retrospective study including 51 eyes of 51 patients with medically uncontrolled glaucoma who underwent Baerveldt implant surgery between June 1994 and December 1998. Criteria for success were intraocular pressure (IOP) < or = 21 mmHg and > 6 mmHg, necessity of further antiglaucoma medications, absence of additional glaucoma surgery and no loss of light perception. RESULTS: Over a mean follow-up of 37.6 (SD: +/-18.8) months, the mean intraocular pressure decreased from 34.8 (+/-12.5) mmHg to 14.0 (+/-4.3) mmHg at month 60. Qualified success rate, achieved when IOP was below 21 mmHg and higher than 6 mmHg with medications was 25/48 (52%), complete success rate (same IOP limits without medication) was 14/48 (29%). Seven eyes had major complications or lost light perception. Postoperative visual acuity improved or remained within one Snellen line of the preoperative visual acuity in 35 patients (73%). Factors associated with a better prognosis were a preoperative visual acuity better than 20/400 and etiology of glaucoma. CONCLUSION: The Baerveldt implant is effective in lowering intraocular pressure in most patients with refractory glaucoma. Long-term results are promising with satisfactory IOP control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to compare foot plantar pressure distribution while jogging and running in highly trained adolescent runners. Eleven participants performed two constant-velocity running trials either at jogging (11.2 ± 0.9 km/h) or running (17.8 ± 1.4 km/h) pace on a treadmill. Contact area (CA in cm(2)), maximum force (F(max) in N), peak pressure (PP in kPa), contact time (CT in ms), and relative load (force time integral in each individual region divided by the force time integral for the total plantar foot surface, in %) were measured in nine regions of the right foot using an in-shoe plantar pressure device. Under the whole foot, CA, F(max) and PP were lower in jogging than in running (-1.2% [p<0.05], -12.3% [p<0.001] and -15.1% [p<0.01] respectively) whereas CT was higher (+20.1%; p<0.001). Interestingly, we found an increase in relative load under the medial and central forefoot regions while jogging (+6.7% and +3.7%, respectively; [p<0.05]), while the relative load under the lesser toes (-8.4%; p<0.05) was reduced. In order to prevent overloading of the metatarsals in adolescent runners, excessive mileage at jogging pace should be avoided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työn tavoitteena oli tutkia hyvän asiakasreferenssin ominaisuuksia suodatinvalmistaja Laroxin myynnin ja huollon sekä yrityksen asiakkaiden näkökulmasta. Larox voi käyttää saatua tietoa referenssien tehokkaampaan valintaan ja hyödyntämiseen. Kaksi internet-kyselyä toteutettiin, välineenä Webropol. Alustava kysely sunnattiin Laroxin myynnille ja huollolle. Kysely koostui viidestä kategoriasta asiakasreferenssejä, joiden tärkeyttä arvioitiin, sekä vapaista vastauksista. Tunnistettuja hyvän asiakasreferenssin ominaisuuksia ovat hyvä suhde referenssiasiakkaaseen, positiiviset jarehelliset suosittelut asiakkaalta, referenssilaitteen hyvä toimintakyky ja asiakas joka ymmärtää huollon tärkeyden. Pääkysely suunnattiin Laroxin asiakkaille. Tilastollisilla analyyseilla tutkittiin koetun riskin mallinmuuttujien välisiä yhteyksiä. Analyysit eivät paljastaneet merkittäviä riippuvuuksia asiakasreferenssin ominaisuuksien tärkeydessä eritaustaisten vastaajien tai tilannetekijöiden välillä, mutta asiakasreferenssin ominaisuuksien faktorit tukevat mallia. Referenssilaitteiden toimintakyky vaikuttaa tärkeimmältä ja huollon tärkeys on myös merkittävä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Self-measurement of blood pressure at home is increasingly used in the diagnostic and therapeutic approach of hypertension. This technique allows multiple measurements of blood pressure away from the clinical setting, making it possible to improve the evaluation of cardiovascular risk. Recently new guidelines on the use of self-measured blood pressure have been made available by the European Society of Hypertension, as summarized in the present paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this thesis is to reveal how the laser cutting parameters influence lasercutting of particleboard, HDF and MDF. The literature review introduces the basic principle of CO2 laser, CO2 laser equipment and its usage in cutting of wood-based materials. The experimental part focuses on the discussion and analysis ofthe test data and attempts to draw conclusions on the influence of various parameters, including laser power, focal length of the lens and cutting gas, on the cutting speed and kerf quality. The tested materials include various thicknesses of particleboard, HDF and MDF samples. A TRUMPF TLF2700 HQ laser equipment was used for the experiments. To obtain valid data, the test samples must be completely cut through without any bonding of wood fibre. The maximum cutting speed is linear dependent on the laser power in thecondition that the other parameters are constant. For each thickness of a specific material type, there is a minimum laser power for cutting. Normally, the topand bottom kerf widths increase with the enhancement of laser power. There may be a critical laser power which can generate the minimum cross-sectional kerf width. Lens of larger focal length may achieve higher cutting speed. As the focal length becomes larger, the top kerf width tends to increase while the bottom andcross-sectional kerf widths to the opposite. Of all cutting gases, oxygen can help achieve higher cutting speed. The gas pressure of nitrogen does not seem to have strong influence on the cutting result. Generally, 2 bar air is more preferable for higher cutting speed. For particleboard and MDF samples of larger thickness than 12 mm, 2 bar argon can be used to reach remarkably higher cutting speed than the 5 bar. Generally, the 190.5 mm lens can produce smallest total kerf width. The kerf sides of thicker samples are darker than the thinner ones. The sample darkness tends to be lower as laser power increased. 63.5 mm lens seemed tocause more darkness than other lens. 5 bar cutting gases can produce less dark side kerfs than 2 bar ones. Oxygen normally causes darker kerfs than other gases. No distinct differences were found between nitrogen and argon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paperikoneinvestointi toteutetaan projekteina, joista muodostuvaa ketjua kutsutaan projektien elinkaareksi. Toteutusketjun viimeinen lenkki on käynnistykseen huipentuva käyttöönotto. Hyvä käyttöönotto palvelee investointia. Käyttöönotoissa koetaan erilaisia ongelmatilanteita, joista osa on satunnaisesti tai usein toistuvia. Investoinnin onnistumisen ja aikataulun asettama paine luo tilanteiden selvittämiseen erityishaasteita. Aina ei selvitä ilman takaiskuja. Tutkimustavoitteena oli kartoittaa käyttöönoton yleiset ongelmat ja niiden yhteydet projektihistoriaan, sekä ne projektinhallinnan osa-alueet, joita parantamalla varmistetaan käyttöönoton ja investoinnin onnistuminen. Tutkimus pohjautuu erilaisistainvestointiprojekteista ja käyttöönotoista saatuihin kokemuksiin, haastatteluihin (3 kpl) ja kyselypalautteeseen (42 kpl). Investoinnin onnistumisedellytykset luodaan projektihistoriassa, käyttöönotossa ne viimeistellään. Onnistuminen mitataan tuotto-odotusten saavuttamisena aikataulussa, johon vaikuttavia tekijöitä ovat tuotannon hallinta, käyttövarmuus ja markkinat. Käyttöönoton onnistumista tulee arvioida käyttöönottotehtävistäsuoriutumisen pohjalta, ei pelkästään investoinnille asetettujen aikataulu- ja tuotantotavoitteiden (laatu, määrä, hallinta) saavuttamisena, kuten usein tapahtuu. Tulosten perusteella käyttöönoton merkittävimmät ongelmat ovat tiedonkulun puutteet, ohjelmallisten korjausten suuri määrä ja palautumisajan riittämättömyys. Tärkeimmät painotukset ovat laiterikkojen estäminen, ohjelmavirheiden korjaaminen ja henkilöstön osaamisen varmentaminen. Konelinjan vaikeimmin hallittava osa on radan päänvienti. Osapuolten poikkeavat näkökulmat sekä työn laadun merkitys testauksissa, koulutuksissa ja kenttätoiminnoissa nousee tuloksista myös vahvasti esiin. Tutkimus on selvittänyt sille asetetut tavoitteet. Käyttöönoton merkittävimmät ongelmat syntyvät sen lähihistoriassa: testauksissa, koulutuksessa ja kenttätoiminnoissa. Käyttöönoton onnistumiseksi tulee painotusprojektinhallinnassa keskittää käynnistysvaiheen suunnitteluun sekä kenttätoimintojen hallintaan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Container Handling Equipment Monitoring System (CHEMS) is a system developed by Savcor One Oy. CHEMS measures important information for container ports performance and produces performance indicators. The aim of this thesis was to clarify performance measurement contents to Savcor and to develop, as an example, performance measures to Steveco Oy's container operations. The theoretical part of the thesis clarifies performance measurement and which of its components are important to container port. Performance measurement and measures are presented from the operational level's point of view, in which CHEMS is planned to aim. The theory of development process of performance measures is introduced at the end of the theoretical part. To make sure that performance measures are efficiently used, Steveco Oy's performance measures are developed in cooperation with the users. The measurement in operational level is continuous and the results must be reacted asquickly as possible. CHEMS is very suitable to continuous measurement and to produce real time-measures of container operations which are hard to get any otherway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To document the prevalence of asynchrony events during noninvasive ventilation in pressure support in infants and in children and to compare the results with neurally adjusted ventilatory assist. DESIGN: Prospective randomized cross-over study in children undergoing noninvasive ventilation. SETTING: The study was performed in a PICU. PATIENTS: From 4 weeks to 5 years. INTERVENTIONS: Two consecutive ventilation periods (pressure support and neurally adjusted ventilatory assist) were applied in random order. During pressure support (PS), three levels of expiratory trigger (ETS) setting were compared: initial ETS (PSinit), and ETS value decreased and increased by 15%. Of the three sessions, the period allowing for the lowest number of asynchrony events was defined as PSbest. Neurally adjusted ventilator assist level was adjusted to match the maximum airway pressure during PSinit. Positive end-expiratory pressure was the same during pressure support and neurally adjusted ventilator assist. Asynchrony events, trigger delay, and cycling-off delay were quantified for each period. RESULTS: Six infants and children were studied. Trigger delay was lower with neurally adjusted ventilator assist versus PSinit and PSbest (61 ms [56-79] vs 149 ms [134-180] and 146 ms [101-162]; p = 0.001 and 0.02, respectively). Inspiratory time in excess showed a trend to be shorter during pressure support versus neurally adjusted ventilator assist. Main asynchrony events during PSinit were autotriggering (4.8/min [1.7-12]), ineffective efforts (9.9/min [1.7-18]), and premature cycling (6.3/min [3.2-18.7]). Premature cycling (3.4/min [1.1-7.7]) was less frequent during PSbest versus PSinit (p = 0.059). The asynchrony index was significantly lower during PSbest versus PSinit (40% [28-65] vs 65.5% [42-76], p < 0.001). With neurally adjusted ventilator assist, all types of asynchronies except double triggering were reduced. The asynchrony index was lower with neurally adjusted ventilator assist (2.3% [0.7-5] vs PSinit and PSbest, p < 0.05 for both comparisons). CONCLUSION: Asynchrony events are frequent during noninvasive ventilation with pressure support in infants and in children despite adjusting the cycling-off criterion. Compared with pressure support, neurally adjusted ventilator assist allows improving patient-ventilator synchrony by reducing trigger delay and the number of asynchrony events. Further studies should determine the clinical impact of these findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Every medical practitioner is confronted on a daily basis with emergencies. Among these, life-threatening emergencies can have disastrous consequences in term of morbidity and mortality; 22 cardiac arrests and 10 deaths were reported among the 1,650 Swiss practices during a 5 year period. The occurrence of life-threatening emergencies at the office necessitates, according to the type and place of the practice, the skills of the practitioner and the organization of his practice, the implementation of procedures, equipments (for example room equipped with a defibrillator, respiratory nebulizer, splints, emergency drugs) and specific continuous education programs that should be encouraged and made available to the whole medical corporation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Short-term exposure to ambient particulate matter with aerodynamic diameters<10 µm were found to be positively associated with blood pressure. Yet, little information exists regarding the association between particles and circadian rhythm of blood pressure. Hence, we analyzed the association of exposure to particulate matter with aerodynamic diameters<10 µm on the day of examination and ≤7 days before with ambulatory blood pressure and with sodium excretion in 359 adults from the general population using multiple linear regression. After controlling for potential confounders, a 10-µg/m3 increase in particulate matter with aerodynamic diameters<10 µm levels was associated with nighttime systolic blood pressure (β=1.32 mm Hg 95% CI, 0.06-2.58 mm Hg at lag 0; P=0.04), nighttime diastolic blood pressure (0.72 mm Hg 95% CI, 0.03-1.42 mm Hg at lag 2; P=0.04), nocturnal systolic blood pressure dipping (-0.96 mm Hg 95% CI, -1.89 to -0.03 mm Hg at lag 0; P=0.044), and daytime urinary sodium excretion (-0.05 log-mmol/min 95% CI, -0.10 to -0.01 log-mmol/min at lag 0; P=0.027) but not with nighttime sodium excretion. The associations with blood pressure rapidly diminished with increasing lag days, and the associations with daytime sodium excretion were maximal with particulate matter with aerodynamic diameters<10 µm in exposures 2 to 5 days before. The associations of short-term increases in particulate matter with aerodynamic diameters<10 µm with higher nighttime blood pressure and blunted systolic blood pressure dipping were preceded by associations with reduced ability of the kidney to excrete sodium during daytime. The underlying mechanism linking air pollution to increased cardiovascular risk may include disturbed circadian rhythms of renal sodium handling and blood pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tutkimuksen tavoitteena on löytää CO2:lle puhdistus- ja inertointikohteita öljynjalostusympäristöstä. CO2:na käytettäisiin Porvoon vetylaitokselta sivutuotteena tulevaa CO2:a. Vetylaitokselta saatava CO2-virta ei ole riittävän puhdasta käytettäväksi suoraan pesuissa ja inertoinnissa. CO2:n eri olomuotoja voidaan käyttää puhdistuksessa. Tutkimuksen lähtökohtana olleen ylikriittisen CO2:n tehokkuus perustuu sen liuottavuuteen. Huonosti liukenevien aineiden liukoisuus ylikriittiseen CO2:in paranee lisäaineiden ja pinta-aktiivisten aineiden käytöllä. Kiinteä CO2 jäädyttää ja poistaa epäpuhtauden sublimoitumisesta aiheutuvan paineaallon voimasta. Kuivajääpuhdistus soveltuu parhaiten tasaisten pintojen puhdistamiseen. Ylikriittisellä CO2:lla onnistuu nykyisellä teknologialla vain pienien kappaleiden puhdistaminen. Kuivajääpuhdistuksen toimivuutta kokeiltiin käytännössä Neste Oilin Porvoon jalostamolla hyvin tuloksin. Tasaisilta pinnoilta saatiin poistetuksi bitumia ja rasvakerros. Käyttökustannusvertailussa osoittautui ylikriittistä CO2:a käyttävä laitteisto halvemmaksi ja kuivajääpuhallus kalliimmaksi kuin konventionaaliset menetelmät. Säiliöiden paineistamiseen ja inertointiin käytetään yleisesti N2:ä. N2:llä inertoitavia kohteita voitaisiin korvata CO2:lla. CO2:n käyttöä rajoittavia seikkoja on hinta ja sen reaktiivisuus alkalimetallien kanssa. Vertailtaessa näiden kahden liukoisuuksia hiilivetyihin osoittautui CO2 monin kerroin liukoisemmaksi. Tämän ominaisuuden ansiosta CO2 voisi olla hyvä väliaine laitteiden hiilivetyvapaaksi saattamisessa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työn kirjallisuusosassa esitellään paperi- ja kartonkikoneiden kiertovoitelujärjestelmien rakennetta ja voitelussa käytettyjen öljyjen ominaisuuksia. Lisäksi on selvitetty voiteluöljyn kunnossapidon kannalta keskeisten epäpuhtauksien kuten veden, hiukkasten ja ilmakuplien analysointia. Suurissa voitelujärjestelmissä öljyn suuri ilmapitoisuus on usein ongelma, mihin ei ole ollut selkeää ratkaisua. Työn tavoitteena oli tutkia ilmakuplien poistamista voiteluöljystä alipainekäsittelyn avulla. Alipaineen vaikusta eri öljyille ja lämpötiloilla tutkittiin laboratoriossa standarditestillä ja määritettiin sopiva alipaine tehdaskokeisiin. Testeissä havaittiin odotutetusti viskositeetin eli käytännössä lämpötilan olevan ratkaiseva tekijä ilman poistumisnopeuteen. Tehdasmittakaavan kokeissa mitattiin rakenteeltaan yksinkertaisen ja vähän energiaa kuluttavan ilmanpoistolaitteen toimintaa. Laitteisto sijoitetaan paluuöljyputkistoon ja sen ei tarvitse olla kiertovoitelukeskuksen yhteydessä. Täysimittainen laitteisto rakennettiin kartonkikoneen ja paperikoneen kiertovoitelujärjestelmiin. Laitteen avulla voidaan käsitellä koko voitelujärjestelmän öljy. Tuloksien mukaan laite toimii odotetulla tavalla ja vähentää merkittävästi ilmapitoisuutta. Järjestelmä on heikoimmillaan tilanteessa, jossa lämpötilat on pidettävä alhaisina ja ilmakuplia on runsaasti.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Painelajittelussa sellusta poistetaan epäpuhtauksia. Painelajittimien suunnittelussa on tärkeää ymmärtää lajittimessa tapahtuvia ilmiöitä. Työn tavoitteena oli kehittää kuvaamiseen perustuva mittausjärjestelmä kuitujen liikkeiden mittaamista varten. Mittauksen kohteena ovat sellusulpun kuitujen ja epäpuhtauksien nopeudet. Kuvaamisessa käytetyllä kaksoisvalotuksella pystytään mittaamaan kuitujen ja roskien nopeuksia. Nopeuksien mittaamiseen kuvista kehitettiin järjestelmä ja tutkittiin mahdollisuutta automatisoida mittaaminen. Yksittäisten kuitujen havaitsemiseen sellumassasta käytettiin optisella kirkasteella kirkastettuja kuituja ja UV-valoa. Kuituja värjättiin myös mustiksi ja kuvattiin näkyvällä valolla. Kaksoisvalotukseen käytettiin kahta stroboskooppia. Prosessin kuvaamisessa käytettiin ulkoisella herätteellä ohjattavaa kameraa. Kuvan tuomiseen kameralle ja kohteen valaistukseen käytettiin boroskooppia. Saatujen kuvien käsittelyä ja nopeuksien mittausta varten tehtiin tietokoneohjelma. Käytetyn boroskoopin valovoima ei ollut riittävä kuvausten suorittamiseen, mutta muilta osin laitteisto havaittiin toimivaksi. Kuitujen ja roskien nopeuksia pystyttiin laskemaan ohjelmalla kuvista, joita otettiin ilman boroskooppia. Mittaustiedon hankinnan automatisointi näyttää mahdolliselta tekemällä muutoksia kuvauslaitteistoon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The antihypertensive effects of the beta-blocking agent betaxolol and the calcium entry blocker verapamil were compared in a crossover single-blind trial. Seventeen patients with uncomplicated essential hypertension took either betaxolol or a slow-release formulation of verapamil for two consecutive 6-week periods. The sequence of treatment phases was randomly allocated and a 2-week washout period preceded each treatment. The antihypertensive effect of the test drugs was assessed both at the physician's office and during everyday activities using a portable blood pressure recorder. The crossover design of the trial made it possible to evaluate the antihypertensive efficacy of betaxolol and verapamil both in the group as a whole and in the individual patient. The individual patient response to one of these agents was not a reliable indicator of the same patient's response to the alternative agent. Betaxolol brought both office and ambulatory recorded blood pressures under control in a larger fraction of patients than verapamil, although the magnitude of the blood pressure fall in the responders was equal for each drug. These observations stress the need for an individualized approach to the evaluation of antihypertensive therapy. The present results also demonstrate that optimal antihypertensive therapy is still a matter of trial and error. The precise methodology that ought to characterize crossover trials may make it possible to improve the therapeutic approach to hypertensive patients.